{"id":367561,"date":"2026-06-29T07:30:01","date_gmt":"2026-06-29T07:30:01","guid":{"rendered":""},"modified":"2026-10-19T09:23:43","modified_gmt":"2026-10-19T09:23:43","slug":"medidor-mid","status":"publish","type":"page","link":"https:\/\/v2charge.com\/be-fr\/zone-de-support\/support-trydan\/medidor-mid\/","title":{"rendered":"Comment connecter et configurer le compteur MID sur Trydan\/Trydan Pro"},"content":{"rendered":"\n<div class=\"wp-block-uagb-container uagb-block-4e29f302 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><div class=\"yoast-breadcrumbs\"><span><span><a href=\"https:\/\/v2charge.com\/be-fr\/\">V2C<\/a><\/span> \u00bb <span><a href=\"https:\/\/v2charge.com\/be-fr\/support\/\">Zone de Support<\/a><\/span> \u00bb <span><a href=\"https:\/\/v2charge.com\/be-fr\/support\/trydan\/\">Support Trydan<\/a><\/span> \u00bb <span class=\"breadcrumb_last\" aria-current=\"page\">Comment connecter et configurer le compteur MID sur Trydan\/Trydan Pro<\/span><\/span><\/div>\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-eb8d37cd\"><h1 class=\"uagb-heading-text\">Comment connecter et configurer le compteur MID sur Trydan\/Trydan Pro<\/h1><\/div>\n\n<p class=\"wp-block-paragraph\">Le <strong>compteur MID<\/strong> est un <strong>dispositif de mesure<\/strong> \u00e9lectrique qui respecte les exigences \u00e9tablies par la Directive Europ\u00e9enne 2014\/32\/UE, connue sous le nom de Directive MID (Measuring Instruments Directive).<\/p>\n\n<p class=\"wp-block-paragraph\">Les compteurs MID permettent de <strong>enregistrer avec pr\u00e9cision l&rsquo;\u00e9nergie consomm\u00e9e<\/strong> lors des recharges de v\u00e9hicules \u00e9lectriques, notamment lorsqu&rsquo;une mesure certifi\u00e9e est requise \u00e0 des fins de facturation. Gr\u00e2ce \u00e0 leur certification MID, ces compteurs permettent aux op\u00e9rateurs, entreprises et particuliers d&rsquo;assurer la transparence dans la facturation de la consommation \u00e9lectrique.<\/p>\n\n<p class=\"wp-block-paragraph\">En plus de leur utilisation dans les chargeurs de v\u00e9hicules \u00e9lectriques, les compteurs MID sont utilis\u00e9s dans des <strong>installations industrielles, commerciales et r\u00e9sidentielles<\/strong> o\u00f9 la pr\u00e9cision et la tra\u00e7abilit\u00e9 des donn\u00e9es \u00e9nerg\u00e9tiques sont cruciales.<\/p>\n\n<h3 class=\"wp-block-heading\">Compteurs compatibles<\/h3>\n\n\n<ul class=\"wp-block-list\"><li><strong>Monophas\u00e9 :<\/strong> CHINT DDSU666. Dans certains documents, il appara\u00eet comme DSSU666 ; v\u00e9rifiez la r\u00e9f\u00e9rence sur l&rsquo;\u00e9tiquette de votre compteur.<\/li>\n\n<li><strong>Trifas\u00e9 :<\/strong> CHINT DTSU666.<\/li>\n\n<li><strong>Autres mod\u00e8les :<\/strong> consultez la fiche technique du fabricant pour identifier les bornes \u00e9quivalentes \u00e0 celles indiqu\u00e9es dans ce guide.<\/li><\/ul>\n\n\n<h3 class=\"wp-block-heading\">Chargeurs compatibles<\/h3>\n\n\n<ul class=\"wp-block-list\"><li>Trydan<\/li>\n\n<li>Trydan Pro<\/li><\/ul>\n\n\n<p class=\"wp-block-paragraph\"><strong>&#x26a0;&#xfe0f; Attention :<\/strong> la tension du r\u00e9seau est dangereuse. Avant de toucher \u00e0 un c\u00e2ble, d\u00e9connectez le disjoncteur qui alimente le chargeur et v\u00e9rifiez qu&rsquo;il n&rsquo;y a pas de tension. L&rsquo;installation doit \u00eatre effectu\u00e9e par un <strong>\u00e9lectricien qualifi\u00e9<\/strong> et respecter la r\u00e9glementation locale.<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>Concernant les num\u00e9ros de borne :<\/strong> les num\u00e9ros de ce guide sont ceux qui sont g\u00e9n\u00e9ralement imprim\u00e9s sur ces compteurs. Avant de serrer un c\u00e2ble, comparez-les toujours avec les marques de votre compteur et avec le sch\u00e9ma de son \u00e9tiquette lat\u00e9rale.<\/p>\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<\/div><\/div>\n\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-d7353680\"><h2 class=\"uagb-heading-text\">1. Connexion \u00e9lectrique du compteur<strong> MID<\/strong><\/h2><\/div>\n\n<p class=\"wp-block-paragraph\">Le compteur MID s&rsquo;installe <strong>en s\u00e9rie avec la ligne qui alimente le chargeur<\/strong> et mesure l&rsquo;\u00e9nergie qui est fournie au chargeur. Tout le courant qui va au chargeur doit passer par le compteur.<\/p>\n\n<h3 class=\"wp-block-heading\">Compteur monophas\u00e9 (DDSU666)<\/h3>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Borne<\/th><th>Connexion<\/th><\/tr><\/thead><tbody><tr><td><strong>1<\/strong><\/td><td>Entr\u00e9e de phase (L), depuis le disjoncteur<\/td><\/tr><tr><td><strong>2<\/strong><\/td><td>Sortie de phase (L), vers le chargeur<\/td><\/tr><tr><td><strong>3<\/strong><\/td><td>Entr\u00e9e de neutre (N), depuis le r\u00e9seau<\/td><\/tr><tr><td><strong>4<\/strong><\/td><td>Sortie de neutre (N), vers le chargeur<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<ol class=\"wp-block-list\"><li>D\u00e9branchez le disjoncteur qui alimente le chargeur.<\/li>\n\n<li>Connectez la phase qui vient de l&rsquo;interrupteur au <strong>borne 1<\/strong>.<\/li>\n\n<li>Connectez un c\u00e2ble de phase depuis le <strong>borne 2<\/strong> jusqu&rsquo;au borne L du chargeur.<\/li>\n\n<li>Connectez le neutre qui vient du r\u00e9seau au <strong>borne 3<\/strong>.<\/li>\n\n<li>Connectez un c\u00e2ble de neutre depuis le <strong>borne 4<\/strong> jusqu&rsquo;au borne N du chargeur.<\/li>\n\n<li>Le c\u00e2ble de terre (PE) <strong>ne passe pas par le compteur<\/strong> : connectez-le directement depuis le r\u00e9seau au chargeur.<\/li>\n\n<li>Serrez bien toutes les vis et v\u00e9rifiez qu&rsquo;aucun cuivre nu ne d\u00e9passe des bornes.<\/li><\/ol>\n\n\n<h3 class=\"wp-block-heading\">Compteur triphas\u00e9 (DTSU666), connexion directe \u00e0 4 fils<\/h3>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Borne<\/th><th>Connexion<\/th><\/tr><\/thead><tbody><tr><td><strong>1<\/strong><\/td><td>Entr\u00e9e de phase L1, depuis le disjoncteur<\/td><\/tr><tr><td><strong>2<\/strong><\/td><td>Sortie de phase L1, vers le chargeur<\/td><\/tr><tr><td><strong>3<\/strong><\/td><td>Entr\u00e9e de phase L2, depuis le disjoncteur<\/td><\/tr><tr><td><strong>4<\/strong><\/td><td>Sortie de phase L2, vers le chargeur<\/td><\/tr><tr><td><strong>5<\/strong><\/td><td>Entr\u00e9e de phase L3, depuis le disjoncteur<\/td><\/tr><tr><td><strong>6<\/strong><\/td><td>Sortie de phase L3, vers le chargeur<\/td><\/tr><tr><td><strong>7<\/strong><\/td><td>Neutre (N), depuis le r\u00e9seau<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<ol class=\"wp-block-list\"><li>D\u00e9branchez le disjoncteur qui alimente le chargeur.<\/li>\n\n<li>Connectez L1, L2 et L3 depuis l&rsquo;interrupteur aux <strong>bornes 1, 3 et 5<\/strong>.<\/li>\n\n<li>Connectez les <strong>bornes 2, 4 et 6<\/strong> aux bornes L1, L2 et L3 du chargeur.<\/li>\n\n<li>Connectez le neutre au <strong>bornier 7<\/strong> et amenez \u00e9galement le neutre au bornier N du chargeur.<\/li>\n\n<li>Connectez le c\u00e2ble de terre (PE) directement depuis le r\u00e9seau au chargeur, sans passer par le compteur.<\/li>\n\n<li>Serrez toutes les vis et v\u00e9rifiez l&rsquo;ordre des phases ainsi que le serrage des c\u00e2bles.<\/li><\/ol>\n\n\n<p class=\"wp-block-paragraph\"><strong>Important :<\/strong> respectez les c\u00f4t\u00e9s d&rsquo;entr\u00e9e et de sortie et maintenez le m\u00eame ordre de phases (L1, L2, L3) dans le compteur et dans le chargeur. Si une entr\u00e9e et une sortie sont \u00e9chang\u00e9es, le compteur enregistrera une \u00e9nergie n\u00e9gative (inverse).<\/p>\n\n<p class=\"wp-block-paragraph\">Si vous utilisez un compteur triphas\u00e9 dans une installation monophas\u00e9e, connectez la phase \u00e0 L1 (<strong>bornes 1 et 2<\/strong>) et le neutre au <strong>borne 7<\/strong>. Ensuite, s\u00e9lectionnez dans le chargeur le type de compteur que vous avez install\u00e9 (voir section 4).<\/p>\n\n<h3 class=\"wp-block-heading\">Chargeurs avec compteur MID int\u00e9gr\u00e9 d&rsquo;usine<\/h3>\n\n<p class=\"wp-block-paragraph\">Si le compteur MID est install\u00e9 \u00e0 l&rsquo;int\u00e9rieur du chargeur, il est aliment\u00e9 <strong>par la phase qui sort du bloc de protections<\/strong>. Comme on le voit sur l&rsquo;image, le neutre (c\u00e2ble bleu) entre et sort par les connecteurs du haut du compteur, et la phase L1 entre et sort par les connecteurs du bas. La communication va au connecteur <strong>CON6 (A et B)<\/strong> de la carte de puissance.<\/p>\n\n\n<div class=\"wp-block-uagb-container uagb-block-a856e430 alignwide uagb-is-root-container\">\n<div class=\"wp-block-uagb-container uagb-block-1c381015\">\n<div class=\"wp-block-uagb-image uagb-block-88976d01 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-zoomin wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/v2charge.com\/wp-content\/uploads\/2025\/08\/medidor-mid.jpg ,https:\/\/v2charge.com\/wp-content\/uploads\/2025\/08\/medidor-mid.jpg 780w, https:\/\/v2charge.com\/wp-content\/uploads\/2025\/08\/medidor-mid.jpg 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2025\/08\/medidor-mid.jpg\" alt=\"\" class=\"uag-image-240966\" width=\"842\" height=\"610\" title=\"medidor-mid\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container margen-acordeon uagb-block-02f02898\"><div class=\"wp-block-uagb-info-box uagb-block-b2701ecb uagb-infobox__content-wrap  uagb-infobox-icon-left uagb-infobox-left uagb-infobox-stacked-tablet uagb-infobox-image-valign-top\"><div class=\"uagb-ifb-image-content\"><img decoding=\"async\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/numero-uno.png\" alt=\"\" width=\"25\" height=\"25\" loading=\"lazy\"\/><\/div><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><\/div><p class=\"uagb-ifb-desc\">Installation monophas\u00e9e<\/p><\/div><\/div>\n\n<div class=\"wp-block-uagb-info-box uagb-block-84c1f95e uagb-infobox__content-wrap  uagb-infobox-icon-left uagb-infobox-left uagb-infobox-stacked-tablet uagb-infobox-image-valign-top\"><div class=\"uagb-ifb-image-content\"><img decoding=\"async\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/numero-dos.png\" alt=\"\" width=\"25\" height=\"25\" loading=\"lazy\"\/><\/div><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><\/div><p class=\"uagb-ifb-desc\">Compteur MID<\/p><\/div><\/div>\n\n<div class=\"wp-block-uagb-info-box uagb-block-d2b382d2 uagb-infobox__content-wrap  uagb-infobox-icon-left uagb-infobox-left uagb-infobox-stacked-tablet uagb-infobox-image-valign-top\"><div class=\"uagb-ifb-image-content\"><img decoding=\"async\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/numero-tres.png\" alt=\"\" width=\"25\" height=\"25\" loading=\"lazy\"\/><\/div><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><\/div><p class=\"uagb-ifb-desc\">Plaque de puissance<\/p><\/div><\/div>\n\n<div class=\"wp-block-uagb-info-box uagb-block-510c4db1 uagb-infobox__content-wrap  uagb-infobox-icon-left uagb-infobox-left uagb-infobox-stacked-tablet uagb-infobox-image-valign-top\"><div class=\"uagb-ifb-image-content\"><img decoding=\"async\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/numero-cuatro.png\" alt=\"\" width=\"25\" height=\"25\" loading=\"lazy\"\/><\/div><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><\/div><p class=\"uagb-ifb-desc\">CON6 (A et B)<\/p><\/div><\/div>\n\n<div class=\"wp-block-uagb-info-box uagb-block-1b65eb79 uagb-infobox__content-wrap  uagb-infobox-icon-left uagb-infobox-left uagb-infobox-stacked-tablet uagb-infobox-image-valign-top\"><div class=\"uagb-ifb-image-content\"><img decoding=\"async\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/numero-cinco.png\" alt=\"\" width=\"25\" height=\"25\" loading=\"lazy\"\/><\/div><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><\/div><p class=\"uagb-ifb-desc\">C\u00e2ble de charge<\/p><\/div><\/div>\n\n<div class=\"wp-block-uagb-info-box uagb-block-617adc4f uagb-infobox__content-wrap  uagb-infobox-icon-left uagb-infobox-left uagb-infobox-stacked-tablet uagb-infobox-image-valign-top\"><div class=\"uagb-ifb-image-content\"><img decoding=\"async\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/12\/numero-seis.png\" alt=\"\" width=\"25\" height=\"25\" loading=\"lazy\"\/><\/div><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><\/div><p class=\"uagb-ifb-desc\">Bo\u00eetier e-Charger<\/p><\/div><\/div><\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-c360059f\"><h2 class=\"uagb-heading-text\">2. Connexion de donn\u00e9es Modbus<strong> (RS485)<\/strong><\/h2><\/div>\n\n<p class=\"wp-block-paragraph\">Le compteur communique avec le chargeur via un bus <strong>Modbus RS485<\/strong>. Utilisez un c\u00e2ble \u00e0 paires torsad\u00e9es blind\u00e9 (par exemple, 2 x 0,5 mm\u00b2 ou similaire) et maintenez-le \u00e9loign\u00e9 des c\u00e2bles de puissance.<\/p>\n\n<h3 class=\"wp-block-heading\">C\u00f4t\u00e9 du compteur<\/h3>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Compteur<\/th><th>RS485 A (+)<\/th><th>RS485 B (\u2212)<\/th><\/tr><\/thead><tbody><tr><td><strong>Monophas\u00e9 (DDSU666)<\/strong><\/td><td>Borne 5<\/td><td>Borne 6<\/td><\/tr><tr><td><strong>Triphas\u00e9 (DTSU666)<\/strong><\/td><td>Borne 24<\/td><td>Borne 25<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 class=\"wp-block-heading\">C\u00f4t\u00e9 du chargeur (Trydan et Trydan Pro)<\/h3>\n\n<p class=\"wp-block-paragraph\">Dans le chargeur, connectez le compteur au bornier RS485 destin\u00e9 au compteur MID \/ Modbus. Les bornes du chargeur sont marqu\u00e9es comme <strong>A\/B<\/strong> :<\/p>\n\n\n<ul class=\"wp-block-list\"><li>A (+) du compteur au bornier <strong>A (+)<\/strong> du chargeur.<\/li>\n\n<li>B (\u2212) du compteur au bornier <strong>B (\u2212)<\/strong> du chargeur.<\/li><\/ul>\n\n\n<p class=\"wp-block-paragraph\">Comme alternative aux bornes A\/B, vous pouvez utiliser un connecteur RJ45 avec un sertissage personnalis\u00e9. Consultez les d\u00e9tails sur <a href=\"https:\/\/v2charge.com\/be-fr\/conexion-modbus-rtu-punto-de-recarga-trydan-para-medidor-como-esclavo\/\">Connexion Modbus RTU du Trydan avec un compteur comme esclave<\/a>.<\/p>\n\n<h3 class=\"wp-block-heading\">Recommandations pour le c\u00e2ble Modbus<\/h3>\n\n\n<ul class=\"wp-block-list\"><li>Connectez toujours A avec A et B avec B.<\/li>\n\n<li>Si plus tard le compteur ne r\u00e9pond pas, essayez d&rsquo;\u00e9changer A et B : c&rsquo;est la cause la plus courante de <strong>manque de communication<\/strong>.<\/li>\n\n<li>Utilisez une seule paire torsad\u00e9e pour A et B : un seul conducteur en cuivre pour la ligne A et un autre pour la ligne B. Ne reliez pas deux c\u00e2bles pour augmenter la section.<\/li>\n\n<li>Rendez le c\u00e2ble aussi court que possible et \u00e9loignez-le des c\u00e2bles r\u00e9seau.<\/li>\n\n<li>R\u00e9tablissez la tension uniquement apr\u00e8s avoir v\u00e9rifi\u00e9 toutes les connexions.<\/li><\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-3e8f3593\"><h2 class=\"uagb-heading-text\">3. Configuration du compteur<strong> MID<\/strong> depuis votre \u00e9cran<\/h2><\/div>\n\n<p class=\"wp-block-paragraph\">Avant que le chargeur puisse lire le compteur, il faut configurer son adresse. <strong>L&rsquo;adresse Modbus du compteur doit \u00eatre 11.<\/strong><\/p>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Param\u00e8tre<\/th><th>Valeur<\/th><\/tr><\/thead><tbody><tr><td><strong>Adresse Modbus (Addr)<\/strong><\/td><td>11 (obligatoire)<\/td><\/tr><tr><td><strong>Vitesse (bAUd)<\/strong><\/td><td>9600 (valeur d&rsquo;usine)<\/td><\/tr><tr><td><strong>Parit\u00e9 \/ format de donn\u00e9es<\/strong><\/td><td>8N1 : sans parit\u00e9, 8 bits de donn\u00e9es, 1 bit d&rsquo;arr\u00eat (valeur d&rsquo;usine)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\">La vitesse et la parit\u00e9 n&rsquo;ont pas besoin d&rsquo;\u00eatre chang\u00e9es : les valeurs d&rsquo;usine (9600 8N1) sont valables. Il est seulement imp\u00e9ratif de changer l&rsquo;adresse \u00e0 11.<\/p>\n\n<h3 class=\"wp-block-heading\">Proc\u00e9dure g\u00e9n\u00e9rale (pour les deux compteurs)<\/h3>\n\n\n<ol class=\"wp-block-list\"><li>Fournit de la tension. Le compteur affiche \u00e0 l&rsquo;\u00e9cran les valeurs qu&rsquo;il mesure.<\/li>\n\n<li>Appuyez sur la touche <strong>ENTER<\/strong> (ou <strong>SET<\/strong>) pour entrer dans le menu de programmation.<\/li>\n\n<li>Le compteur demande un mot de passe. Le <strong>mot de passe par d\u00e9faut est 701<\/strong> : saisissez-le avec les fl\u00e8ches et confirmez avec ENTER.<\/li>\n\n<li>Navigatez avec les fl\u00e8ches jusqu&rsquo;au menu des param\u00e8tres de communication.<\/li>\n\n<li>S\u00e9lectionnez l&rsquo;adresse Modbus (<strong>Addr<\/strong>), changez-la en <strong>11<\/strong> et confirmez avec ENTER.<\/li>\n\n<li>V\u00e9rifiez la vitesse (<strong>bAUd<\/strong>) et la parit\u00e9 et ajustez-les selon le tableau pr\u00e9c\u00e9dent. Confirmez avec ENTER.<\/li>\n\n<li>Appuyez sur <strong>ESC<\/strong> plusieurs fois jusqu&rsquo;\u00e0 revenir \u00e0 l&rsquo;\u00e9cran de mesure. Les r\u00e9glages sont enregistr\u00e9s.<\/li><\/ol>\n\n\n<h3 class=\"wp-block-heading\">Compteur monophase (DDSU666)<\/h3>\n\n<p class=\"wp-block-paragraph\">Suivez la proc\u00e9dure g\u00e9n\u00e9rale. Ce compteur a un menu simple. Apr\u00e8s avoir chang\u00e9 l&rsquo;adresse, l&rsquo;\u00e9cran doit afficher la valeur 11 dans le param\u00e8tre Addr.<\/p>\n\n<h3 class=\"wp-block-heading\">Compteur triphas\u00e9 (DTSU666)<\/h3>\n\n<p class=\"wp-block-paragraph\">Suivez la proc\u00e9dure g\u00e9n\u00e9rale. Ce compteur a plus d&rsquo;options de menu (par exemple, rapport de transformation et type de connexion) :<\/p>\n\n\n<ul class=\"wp-block-list\"><li>Rapport de transformation (CT) : laissez-le \u00e0 <strong>1<\/strong> (compteur de connexion directe).<\/li>\n\n<li>Type de connexion : <strong>triphas\u00e9 \u00e0 4 fils<\/strong>.<\/li>\n\n<li>Adresse : <strong>11<\/strong>.<\/li><\/ul>\n\n\n<h3 class=\"wp-block-heading\">V\u00e9rifiez le compteur<\/h3>\n\n<p class=\"wp-block-paragraph\">Apr\u00e8s avoir modifi\u00e9 les param\u00e8tres, le compteur doit continuer \u00e0 afficher des valeurs de tension, de courant et d&rsquo;\u00e9nergie. Si aucune valeur de tension n&rsquo;appara\u00eet, v\u00e9rifiez la connexion \u00e9lectrique du point 1.<\/p>\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-3a30a855\"><h2 class=\"uagb-heading-text\">4. Configuration du Trydan depuis votre<strong> \u00e9cran<\/strong><\/h2><\/div>\n\n<p class=\"wp-block-paragraph\">Ces \u00e9tapes sont les m\u00eames pour Trydan et Trydan Pro.<\/p>\n\n\n<ol class=\"wp-block-list\"><li>Allumez le chargeur et attendez que l&rsquo;\u00e9cran principal apparaisse.<\/li>\n\n<li>Acc\u00e9dez au menu de configuration en maintenant enfonc\u00e9s les deux boutons lat\u00e9raux. Plus d&rsquo;informations sur <a href=\"https:\/\/v2charge.com\/be-fr\/soporte\/trydan\/botones-navegacion-display\/\">les boutons et la navigation de l&rsquo;\u00e9cran<\/a>.<\/li>\n\n<li>Allez \u00e0 la section <strong>\u00abAdditionnel\u00bb<\/strong>.<\/li>\n\n<li>S\u00e9lectionnez l&rsquo;option <strong>\u00abCompteur MID\u00bb<\/strong>.<\/li>\n\n<li>Choisissez le mod\u00e8le de compteur que vous avez install\u00e9 : <strong>\u00abMonophas\u00e9\u00bb<\/strong> (DDSU666) ou <strong>\u00abTriphas\u00e9\u00bb<\/strong> (DTSU666). S&rsquo;il existe d&rsquo;autres mod\u00e8les compatibles, ils appara\u00eetront \u00e9galement ici.<\/li>\n\n<li>Confirme la s\u00e9lection et revenez \u00e0 l&rsquo;\u00e9cran principal.<\/li><\/ol>\n\n\n<p class=\"wp-block-paragraph\">Si le chargeur n&rsquo;a pas de compteur MID, l&rsquo;option <strong>\u00abNon\u00bb<\/strong> doit \u00eatre s\u00e9lectionn\u00e9e.<\/p>\n\n\n<div class=\"wp-block-uagb-container uagb-block-d7888932 default uagb-is-root-container\">\n<div class=\"wp-block-uagb-container uagb-block-51c979ca\">\n<div class=\"wp-block-uagb-image uagb-block-522c59ec wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/05\/medidor-mid-monofasico.png ,https:\/\/v2charge.com\/wp-content\/uploads\/2024\/05\/medidor-mid-monofasico.png 780w, https:\/\/v2charge.com\/wp-content\/uploads\/2024\/05\/medidor-mid-monofasico.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/05\/medidor-mid-monofasico.png\" alt=\"\" class=\"uag-image-157128\" width=\"685\" height=\"166\" title=\"medidor-mid-monofasico\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-c2a9fa26\">\n<div class=\"wp-block-uagb-image uagb-block-1dd3bb79 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/05\/medidor-mid-no.png ,https:\/\/v2charge.com\/wp-content\/uploads\/2024\/05\/medidor-mid-no.png 780w, https:\/\/v2charge.com\/wp-content\/uploads\/2024\/05\/medidor-mid-no.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/05\/medidor-mid-no.png\" alt=\"\" class=\"uag-image-157138\" width=\"685\" height=\"166\" title=\"medidor-mid-no\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-971804f3\">\n<div class=\"wp-block-uagb-image uagb-block-8e1dc988 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/05\/medidor-mid-trifasico.png ,https:\/\/v2charge.com\/wp-content\/uploads\/2024\/05\/medidor-mid-trifasico.png 780w, https:\/\/v2charge.com\/wp-content\/uploads\/2024\/05\/medidor-mid-trifasico.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/05\/medidor-mid-trifasico.png\" alt=\"\" class=\"uag-image-157148\" width=\"685\" height=\"166\" title=\"medidor-mid-trifasico\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n<\/div>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\">V\u00e9rifiez que le compteur fonctionne<\/h3>\n\n\n<ol class=\"wp-block-list\"><li>Apr\u00e8s quelques secondes, le chargeur doit afficher l&rsquo;\u00e9nergie et la puissance qu&rsquo;il lit du compteur MID.<\/li>\n\n<li>Connectez un v\u00e9hicule (ou une charge connue) et v\u00e9rifiez que la valeur de puissance change. Les valeurs doivent \u00eatre raisonnables et avoir le bon signe (positif lors de la charge).<\/li>\n\n<li>Si les valeurs sont nulles ou si le chargeur affiche une erreur de communication avec le compteur, consultez la section 5.<\/li><\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-23dfb36f\"><h2 class=\"uagb-heading-text\">5. R\u00e9solution de<strong> probl\u00e8mes<\/strong><\/h2><\/div>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Probl\u00e8me<\/th><th>\u00c0 v\u00e9rifier<\/th><\/tr><\/thead><tbody><tr><td><strong>Sans communication ou erreur de communication<\/strong><\/td><td>Que l&rsquo;adresse du compteur soit 11.<br>Que la vitesse et la parit\u00e9 soient celles d&rsquo;origine (9600 8N1).<br>Les c\u00e2bles RS485 A et B : \u00e9changez-les si n\u00e9cessaire (d\u00e9connectez d&rsquo;abord la tension).<br>Que le mod\u00e8le correct (monophas\u00e9 ou triphas\u00e9) soit s\u00e9lectionn\u00e9 sur l&rsquo;\u00e9cran du chargeur.<\/td><\/tr><tr><td><strong>\u00c9nergie ou puissance n\u00e9gative<\/strong><\/td><td>Les c\u00e2bles d&rsquo;entr\u00e9e et de sortie du compteur sont \u00e9chang\u00e9s : corrigez-les.<\/td><\/tr><tr><td><strong>L&rsquo;\u00e9cran du compteur est \u00e9teint<\/strong><\/td><td>Aucune tension n&rsquo;atteint le compteur. V\u00e9rifiez le disjoncteur et les bornes 1 et 3 (monophas\u00e9) ou 1, 3, 5 et 7 (triphas\u00e9).<\/td><\/tr><tr><td><strong>Valeur de puissance incorrecte dans une installation triphas\u00e9e<\/strong><\/td><td>L&rsquo;ordre des phases L1, L2, L3 et que le type de connexion soit triphas\u00e9 \u00e0 4 fils.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer uag-hide-mob\"><\/div>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-c6f38013 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><div class=\"wp-block-uagb-advanced-heading uagb-block-6963d70c\"><h2 class=\"uagb-heading-text\"><strong>Avez-vous besoin d&rsquo;un support technique ?<\/strong><\/h2><\/div>\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-408243eb\"><p class=\"uagb-heading-text\">R\u00e9solvez votre incident instantan\u00e9ment via notre Chat avec IA. Si cela n&rsquo;est pas r\u00e9solu, g\u00e9n\u00e9rez une demande dans le Centre de Support Technique et nous vous contacterons d\u00e8s que possible pour vous offrir la meilleure solution.<\/p><\/div>\n\n<div class=\"wp-block-uagb-info-box uagb-block-12e3cf1c uagb-infobox__content-wrap  uagb-infobox-icon-left uagb-infobox-left uagb-infobox-image-valign-top wp-block-uagb-info-box--has-margin ai-chatbot-button\"><div class=\"uagb-infobox-margin-wrapper\"><div class=\"uagb-ifb-image-content\"><img decoding=\"async\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2026\/01\/support-ai-chatbot.png\" alt=\"\" width=\"20\" height=\"19\" loading=\"lazy\"\/><\/div><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><\/div><div class=\"uagb-ifb-button-wrapper wp-block-button\"><a href=\"https:\/\/v2charge.com\/be-fr\/v2c-support-web\/\" class=\"uagb-infobox-cta-link wp-block-button__link\" target=\"_blank\" rel=\"noopener noreferrer\" onclick=\"return true;\"><span class=\"uagb-inline-editing\">Demandez \u00e0 notre Chat avec IA<\/span><\/a><\/div><\/div><\/div><\/div>\n\n\n<div class=\"wp-block-uagb-buttons uagb-buttons__outer-wrap uagb-btn__default-btn uagb-btn-tablet__default-btn uagb-btn-mobile__default-btn uagb-block-ba1e67d1\"><div class=\"uagb-buttons__wrap uagb-buttons-layout-wrap \"><div class=\"wp-block-uagb-buttons-child uagb-buttons__outer-wrap uagb-block-23cfb623 wp-block-button\"><div class=\"uagb-button__wrapper\"><a class=\"uagb-buttons-repeater wp-block-button__link\" aria-label=\"\" href=\"https:\/\/servicedesk.v2charge.com\" rel=\"follow noopener\" target=\"_blank\" role=\"button\"><div class=\"uagb-button__link\">Contactez le Support Technique<\/div><\/a><\/div><\/div><\/div><\/div>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Comment connecter et configurer le compteur MID sur Trydan\/Trydan Pro Le compteur MID est un dispositif de mesure \u00e9lectrique qui respecte les exigences \u00e9tablies par la Directive Europ\u00e9enne 2014\/32\/UE, connue sous le nom de Directive MID (Measuring Instruments Directive). Les compteurs MID permettent de enregistrer avec pr\u00e9cision l&rsquo;\u00e9nergie consomm\u00e9e lors des recharges de v\u00e9hicules \u00e9lectriques, &#8230; <a title=\"Comment connecter et configurer le compteur MID sur Trydan\/Trydan Pro\" class=\"read-more\" href=\"https:\/\/v2charge.com\/be-fr\/zone-de-support\/support-trydan\/medidor-mid\/\" aria-label=\"Read more about Comment connecter et configurer le compteur MID sur Trydan\/Trydan Pro\">Lire la suite<\/a><\/p>\n","protected":false},"author":400,"featured_media":0,"parent":367316,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_eb_attr":"","content-type":"","_uag_custom_page_level_css":"","footnotes":""},"class_list":["post-367561","page","type-page","status-publish"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Comment connecter et configurer le compteur MID sur Trydan\/Trydan Pro | V2C<\/title>\n<meta name=\"description\" content=\"D\u00e9couvrez comment connecter et configurer le compteur MID sur Trydan\/Trydan Pro pour enregistrer avec pr\u00e9cision l&#039;\u00e9nergie consomm\u00e9e lors des recharges de VE.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/v2charge.com\/be-fr\/zone-de-support\/support-trydan\/medidor-mid\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Comment connecter et configurer le compteur MID sur Trydan\/Trydan Pro | V2C\" \/>\n<meta property=\"og:description\" content=\"D\u00e9couvrez comment connecter et configurer le compteur MID sur Trydan\/Trydan Pro pour enregistrer avec pr\u00e9cision l&#039;\u00e9nergie consomm\u00e9e lors des recharges de VE.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/v2charge.com\/be-fr\/zone-de-support\/support-trydan\/medidor-mid\/\" \/>\n<meta property=\"og:site_name\" content=\"V2C\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/V2C.Charge\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-19T09:23:43+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/v2charge.com\/wp-content\/uploads\/2025\/08\/medidor-mid.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@V2C_Charge\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture est.\" \/>\n\t<meta name=\"twitter:data1\" content=\"8 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/v2charge.com\\\/be-fr\\\/zone-de-support\\\/support-trydan\\\/medidor-mid\\\/\",\"url\":\"https:\\\/\\\/v2charge.com\\\/be-fr\\\/zone-de-support\\\/support-trydan\\\/medidor-mid\\\/\",\"name\":\"Comment connecter et configurer le compteur MID sur Trydan\\\/Trydan Pro | V2C\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/v2charge.com\\\/be-fr\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/v2charge.com\\\/be-fr\\\/zone-de-support\\\/support-trydan\\\/medidor-mid\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/v2charge.com\\\/be-fr\\\/zone-de-support\\\/support-trydan\\\/medidor-mid\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/v2charge.com\\\/wp-content\\\/uploads\\\/2025\\\/08\\\/medidor-mid.jpg\",\"datePublished\":\"2026-06-29T07:30:01+00:00\",\"dateModified\":\"2026-10-19T09:23:43+00:00\",\"description\":\"D\u00e9couvrez comment connecter et configurer le compteur MID sur Trydan\\\/Trydan Pro pour enregistrer avec pr\u00e9cision l'\u00e9nergie consomm\u00e9e lors des recharges de VE.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/v2charge.com\\\/be-fr\\\/zone-de-support\\\/support-trydan\\\/medidor-mid\\\/#breadcrumb\"},\"inLanguage\":\"fr-BE\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/v2charge.com\\\/be-fr\\\/zone-de-support\\\/support-trydan\\\/medidor-mid\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-BE\",\"@id\":\"https:\\\/\\\/v2charge.com\\\/be-fr\\\/zone-de-support\\\/support-trydan\\\/medidor-mid\\\/#primaryimage\",\"url\":\"https:\\\/\\\/v2charge.com\\\/wp-content\\\/uploads\\\/2025\\\/08\\\/medidor-mid.jpg\",\"contentUrl\":\"https:\\\/\\\/v2charge.com\\\/wp-content\\\/uploads\\\/2025\\\/08\\\/medidor-mid.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/v2charge.com\\\/be-fr\\\/zone-de-support\\\/support-trydan\\\/medidor-mid\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"V2C\",\"item\":\"https:\\\/\\\/v2charge.com\\\/be-fr\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Zone de Support\",\"item\":\"https:\\\/\\\/v2charge.com\\\/be-fr\\\/support\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Support Trydan\",\"item\":\"https:\\\/\\\/v2charge.com\\\/be-fr\\\/support\\\/trydan\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Comment connecter et configurer le compteur MID sur Trydan\\\/Trydan Pro\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/v2charge.com\\\/be-fr\\\/#website\",\"url\":\"https:\\\/\\\/v2charge.com\\\/be-fr\\\/\",\"name\":\"V2C\",\"description\":\"#CargandoElMa\u00f1ana\",\"publisher\":{\"@id\":\"https:\\\/\\\/v2charge.com\\\/be-fr\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/v2charge.com\\\/be-fr\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-BE\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/v2charge.com\\\/be-fr\\\/#organization\",\"name\":\"V2C\",\"url\":\"https:\\\/\\\/v2charge.com\\\/be-fr\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-BE\",\"@id\":\"https:\\\/\\\/v2charge.com\\\/be-fr\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/v2charge.com\\\/wp-content\\\/uploads\\\/2024\\\/11\\\/cropped-v2c-charge-logo-menu.png\",\"contentUrl\":\"https:\\\/\\\/v2charge.com\\\/wp-content\\\/uploads\\\/2024\\\/11\\\/cropped-v2c-charge-logo-menu.png\",\"width\":984,\"height\":431,\"caption\":\"V2C\"},\"image\":{\"@id\":\"https:\\\/\\\/v2charge.com\\\/be-fr\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/V2C.Charge\",\"https:\\\/\\\/x.com\\\/V2C_Charge\",\"https:\\\/\\\/www.instagram.com\\\/v2c.charge\\\/\",\"https:\\\/\\\/www.youtube.com\\\/@V2C\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/v2c-chargers\\\/\"],\"contactPoint\":[{\"@type\":\"ContactPoint\",\"contactType\":\"customer support\",\"telephone\":\"+34960654554\",\"email\":\"info@v2charge.com\",\"availableLanguage\":[\"Spanish\",\"English\",\"Portuguese\",\"French\"]},{\"@type\":\"ContactPoint\",\"contactType\":\"sales\",\"telephone\":\"+34960654554\",\"email\":\"info@v2charge.com\",\"availableLanguage\":[\"Spanish\",\"English\"]}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Comment connecter et configurer le compteur MID sur Trydan\/Trydan Pro | V2C","description":"D\u00e9couvrez comment connecter et configurer le compteur MID sur Trydan\/Trydan Pro pour enregistrer avec pr\u00e9cision l'\u00e9nergie consomm\u00e9e lors des recharges de VE.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/v2charge.com\/be-fr\/zone-de-support\/support-trydan\/medidor-mid\/","og_locale":"fr_FR","og_type":"article","og_title":"Comment connecter et configurer le compteur MID sur Trydan\/Trydan Pro | V2C","og_description":"D\u00e9couvrez comment connecter et configurer le compteur MID sur Trydan\/Trydan Pro pour enregistrer avec pr\u00e9cision l'\u00e9nergie consomm\u00e9e lors des recharges de VE.","og_url":"https:\/\/v2charge.com\/be-fr\/zone-de-support\/support-trydan\/medidor-mid\/","og_site_name":"V2C","article_publisher":"https:\/\/www.facebook.com\/V2C.Charge","article_modified_time":"2026-10-19T09:23:43+00:00","og_image":[{"url":"https:\/\/v2charge.com\/wp-content\/uploads\/2025\/08\/medidor-mid.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_site":"@V2C_Charge","twitter_misc":{"Dur\u00e9e de lecture est.":"8 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/v2charge.com\/be-fr\/zone-de-support\/support-trydan\/medidor-mid\/","url":"https:\/\/v2charge.com\/be-fr\/zone-de-support\/support-trydan\/medidor-mid\/","name":"Comment connecter et configurer le compteur MID sur Trydan\/Trydan Pro | V2C","isPartOf":{"@id":"https:\/\/v2charge.com\/be-fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/v2charge.com\/be-fr\/zone-de-support\/support-trydan\/medidor-mid\/#primaryimage"},"image":{"@id":"https:\/\/v2charge.com\/be-fr\/zone-de-support\/support-trydan\/medidor-mid\/#primaryimage"},"thumbnailUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2025\/08\/medidor-mid.jpg","datePublished":"2026-06-29T07:30:01+00:00","dateModified":"2026-10-19T09:23:43+00:00","description":"D\u00e9couvrez comment connecter et configurer le compteur MID sur Trydan\/Trydan Pro pour enregistrer avec pr\u00e9cision l'\u00e9nergie consomm\u00e9e lors des recharges de VE.","breadcrumb":{"@id":"https:\/\/v2charge.com\/be-fr\/zone-de-support\/support-trydan\/medidor-mid\/#breadcrumb"},"inLanguage":"fr-BE","potentialAction":[{"@type":"ReadAction","target":["https:\/\/v2charge.com\/be-fr\/zone-de-support\/support-trydan\/medidor-mid\/"]}]},{"@type":"ImageObject","inLanguage":"fr-BE","@id":"https:\/\/v2charge.com\/be-fr\/zone-de-support\/support-trydan\/medidor-mid\/#primaryimage","url":"https:\/\/v2charge.com\/wp-content\/uploads\/2025\/08\/medidor-mid.jpg","contentUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2025\/08\/medidor-mid.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/v2charge.com\/be-fr\/zone-de-support\/support-trydan\/medidor-mid\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"V2C","item":"https:\/\/v2charge.com\/be-fr\/"},{"@type":"ListItem","position":2,"name":"Zone de Support","item":"https:\/\/v2charge.com\/be-fr\/support\/"},{"@type":"ListItem","position":3,"name":"Support Trydan","item":"https:\/\/v2charge.com\/be-fr\/support\/trydan\/"},{"@type":"ListItem","position":4,"name":"Comment connecter et configurer le compteur MID sur Trydan\/Trydan Pro"}]},{"@type":"WebSite","@id":"https:\/\/v2charge.com\/be-fr\/#website","url":"https:\/\/v2charge.com\/be-fr\/","name":"V2C","description":"#CargandoElMa\u00f1ana","publisher":{"@id":"https:\/\/v2charge.com\/be-fr\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/v2charge.com\/be-fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-BE"},{"@type":"Organization","@id":"https:\/\/v2charge.com\/be-fr\/#organization","name":"V2C","url":"https:\/\/v2charge.com\/be-fr\/","logo":{"@type":"ImageObject","inLanguage":"fr-BE","@id":"https:\/\/v2charge.com\/be-fr\/#\/schema\/logo\/image\/","url":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png","contentUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png","width":984,"height":431,"caption":"V2C"},"image":{"@id":"https:\/\/v2charge.com\/be-fr\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/V2C.Charge","https:\/\/x.com\/V2C_Charge","https:\/\/www.instagram.com\/v2c.charge\/","https:\/\/www.youtube.com\/@V2C","https:\/\/www.linkedin.com\/company\/v2c-chargers\/"],"contactPoint":[{"@type":"ContactPoint","contactType":"customer support","telephone":"+34960654554","email":"info@v2charge.com","availableLanguage":["Spanish","English","Portuguese","French"]},{"@type":"ContactPoint","contactType":"sales","telephone":"+34960654554","email":"info@v2charge.com","availableLanguage":["Spanish","English"]}]}]}},"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"gs-tiny":false,"xl":false,"xxl":false,"xxxl":false,"xxxxl":false,"xxxxxl":false,"1536x1536":false,"2048x2048":false},"uagb_author_info":{"display_name":"V2C","author_link":"https:\/\/v2charge.com\/be-fr\/author\/marketing\/"},"uagb_comment_info":0,"uagb_excerpt":"Comment connecter et configurer le compteur MID sur Trydan\/Trydan Pro Le compteur MID est un dispositif de mesure \u00e9lectrique qui respecte les exigences \u00e9tablies par la Directive Europ\u00e9enne 2014\/32\/UE, connue sous le nom de Directive MID (Measuring Instruments Directive). Les compteurs MID permettent de enregistrer avec pr\u00e9cision l&rsquo;\u00e9nergie consomm\u00e9e lors des recharges de v\u00e9hicules \u00e9lectriques,&hellip;","_links":{"self":[{"href":"https:\/\/v2charge.com\/be-fr\/wp-json\/wp\/v2\/pages\/367561","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/v2charge.com\/be-fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/v2charge.com\/be-fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/v2charge.com\/be-fr\/wp-json\/wp\/v2\/users\/400"}],"replies":[{"embeddable":true,"href":"https:\/\/v2charge.com\/be-fr\/wp-json\/wp\/v2\/comments?post=367561"}],"version-history":[{"count":0,"href":"https:\/\/v2charge.com\/be-fr\/wp-json\/wp\/v2\/pages\/367561\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/v2charge.com\/be-fr\/wp-json\/wp\/v2\/pages\/367316"}],"wp:attachment":[{"href":"https:\/\/v2charge.com\/be-fr\/wp-json\/wp\/v2\/media?parent=367561"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}