{"id":310106,"date":"2024-10-04T15:39:28","date_gmt":"2024-10-04T13:39:28","guid":{"rendered":""},"modified":"2026-01-13T16:45:07","modified_gmt":"2026-01-13T14:45:07","slug":"codis-errors-connexio","status":"publish","type":"page","link":"https:\/\/v2charge.com\/ca\/area-de-suport\/control-de-potencia\/control-dinamic-de-potencia\/codis-errors-connexio\/","title":{"rendered":"C\u00f2digs d&#8217;errors de connexi\u00f3 i la seva soluci\u00f3"},"content":{"rendered":"\n<div class=\"wp-block-uagb-container uagb-block-9d828d1c alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><div class=\"yoast-breadcrumbs\"><span><span><a href=\"https:\/\/v2charge.com\/ca\/\">V2C<\/a><\/span> \u00bb <span><a href=\"https:\/\/v2charge.com\/ca\/support\/power-control\/dynamic\/\">Din\u00e1mico<\/a><\/span> \u00bb <span class=\"breadcrumb_last\" aria-current=\"page\">C\u00f2digs d&#8217;errors de connexi\u00f3 i la seva soluci\u00f3<\/span><\/span><\/div>\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-be8360a4\"><h1 class=\"uagb-heading-text\">Codis d&#8217;errors de connexi\u00f3 i la seva soluci\u00f3<\/h1><\/div>\n\n<p>Si en activar el control din\u00e0mic de pot\u00e8ncia en el carregador Trydan o Trydan Pro hi ha un error, al display del carregador apareixer\u00e0 un <strong>codi corresponent a l&#8217;error<\/strong>.<br><br>Les solucions als errors establerts a continuaci\u00f3 corresponen a la <strong>versi\u00f3 1.6.18 o superiors<\/strong>. En cas de tenir una versi\u00f3 inferior, <a href=\"https:\/\/v2charge.com\/ca\/area-de-suport\/suport-pole-pro\/actualizar-la-darrera-versio-pole-pro\/\"><strong>actualitza el carregador Trydan<\/strong><\/a> i comprova de nou la seg\u00fcent llista.<\/p><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-f83ba0fb alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-9d537ef2\">\n<div class=\"wp-block-uagb-container uagb-block-1021f2c1\">\n<div class=\"wp-block-uagb-image aligncenter uagb-block-f5b78000 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-center\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png ,https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png 780w, https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png\" alt=\"\" class=\"uag-image-125013\" width=\"50\" height=\"50\" title=\"\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-a8351972\"><div class=\"wp-block-uagb-advanced-heading uagb-block-fdcb9def\"><p class=\"uagb-heading-text\"><strong>NOTA IMPORTANTE:<\/strong> aquests errors deriven d&#8217;una fallada de comunicaci\u00f3 entre Trydan i l&#8217;inversor o mesurador i limiten la c\u00e0rrega del seu vehicle al m\u00ednim. Alguns poden produir-se quan la integraci\u00f3 \u00e9s directa amb l&#8217;inversor, ja sigui mitjan\u00e7ant comunicaci\u00f3 Modbus o RS485.<br><strong>\u00c9s imprescindible consultar la soluci\u00f3 a l&#8217;error que apareix a la pantalla. <\/strong>En cas de persistir l&#8217;error, comunica-ho al nostre departament de Suport T\u00e8cnic i desactiva el control din\u00e0mic de c\u00e0rrega per poder carregar a la intensitat fixa establerta.<\/p><\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-separator uagb-block-b0f92113\"><div class=\"wp-block-uagb-separator__inner\" style=\"--my-background-image:\"><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-4d0c1e2a\">\n<div class=\"wp-block-uagb-container uagb-block-195968cb\"><table style=\"border:none;\">\n    <tr style=\"border:none;\">\n        <th style=\"border:none;\">ERROR<\/th>\n        <th style=\"border:none;\"><u>00<\/u><\/th>\n        <th style=\"border:none;\"><u>000<\/u><\/th>\n    <\/tr>\n    <tr style=\"border:none;\">\n        <td style=\"border:none;\"><\/td>\n        <td style=\"border:none;\"><center>A<\/center><\/td>\n        <td style=\"border:none;\"><center>B<\/center><\/td>\n    <\/tr>\n<\/table><\/div>\n<\/div>\n\n\n<p>Les <strong>dues primeres xifres<\/strong> indiquen el comptador o inversor que estem utilitzant. \u00c9s important seleccionar el correcte quan es configura el control din\u00e0mic de pot\u00e8ncia i revisar que sigui correcte en cas d&#8217;error.<\/p>\n\n\n<div class=\"wp-block-uagb-container uagb-block-8616beaf\">\n<div class=\"wp-block-uagb-container uagb-block-9f8097ef\"><p><strong>Errors &#8211; A<\/strong><\/p><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-4816f3c8\"><p><strong>00<\/strong>  Mesurador Shelly<br><strong>01<\/strong>  V2C ControlBox<br><strong>02<\/strong>  Mesurador V2C 1.0<br><strong>03<\/strong>  Connexi\u00f3 a inversor Huawei<br><strong>04<\/strong>  Connexi\u00f3 a inversor Solax<br><strong>05<\/strong>  Connexi\u00f3 a inversor Kostal<br><strong>06<\/strong>  Connexi\u00f3 a inversor Fronius<br><strong>07<\/strong>  Connexi\u00f3 a inversor Ingeteam<br><strong>08  <\/strong>Connexi\u00f3 a mesurador Wibeee<br><strong>09<\/strong>  Connexi\u00f3 a mesurador Victron<br><strong>10<\/strong>  Connexi\u00f3 a inversor SolarEdge<br><strong>11<\/strong>  \u00das del protocol\u00b7lo MQTT<\/p><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-8ef7ba8e\"><p><strong>12<\/strong> Connexi\u00f3 a inversor Goodwe<br><strong>13<\/strong> Connexi\u00f3 a inversor SAJ \/ GreenHeiss<br><strong>14<\/strong> Connexi\u00f3 a inversor Solis<br><strong>15<\/strong> Connexi\u00f3 a mesurador Chint DDSU666<br><strong>16<\/strong> Connexi\u00f3 a mesurador Eastron<br><strong>17<\/strong> Connexi\u00f3 a mesurador Phoneix Contact<br><strong>18<\/strong> Connexi\u00f3 a mesurador Carlo Gavazzi<br><strong>19<\/strong> Connexi\u00f3 a mesurador SMA<br><strong>20<\/strong> Connexi\u00f3 a inversor Deye \/ Turbo Energy<br><strong>21<\/strong> Connexi\u00f3 a inversor ENPHASE<br><strong>22<\/strong> Connexi\u00f3 a mesurador WiFi P1 Meter<br><strong>23 <\/strong>Connexi\u00f3 per Modbus<br><strong>25<\/strong> Connexi\u00f3 a mesurador Shelly Pro<br><strong>26<\/strong> Connexi\u00f3 a inversor Growatt<br><strong>27<\/strong> Connexi\u00f3 a inversor Sungrow<br><strong>28 <\/strong>Connexi\u00f3 a mesurador LINKY LORA<br><strong>94<\/strong> Fora de rang mesura Car<br><strong>95<\/strong> Fora de rang mesura Grid<br><strong>96<\/strong> Fora de rang mesura House<br><strong>97<\/strong> Fora de rang mesura Battery<br><strong>98 <\/strong>Fora de rang mesura FV<br><strong>99 <\/strong>Connexi\u00f3 entre dos carregadors Trydan en mode de&nbsp;balanceig de c\u00e0rrega<\/p><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-separator uagb-block-b634b355\"><div class=\"wp-block-uagb-separator__inner\" style=\"--my-background-image:\"><\/div><\/div>\n\n\n<p><strong>Errors &#8211; B<\/strong><\/p>\n\n\n<div class=\"wp-block-uagb-container uagb-block-842d9744\">\n<div class=\"wp-block-uagb-container uagb-block-f682e240\"><p><strong>000<\/strong>&nbsp;Mesures fora de rang.<br><strong><strong>Comprovar<\/strong><\/strong>:<br>&#8211; Si el carregador disposa d&#8217;un mesurador intern. Comprovar la marca, si \u00e9s monof\u00e0sic o trif\u00e0sic, i configurar-ho al carregador des de la botonera, o b\u00e9 contactar amb suport per configurar-ho de manera remota si el carregador est\u00e0 en l\u00ednia.<br>&#8211; Connexi\u00f3 f\u00edsica correcta del mesurador amb la placa de pot\u00e8ncia.<br><br><strong><strong>001<\/strong> <\/strong>Per a equips Goodwe amb protocol UDP<strong><br><strong>Comprovar<\/strong><\/strong>:<br>&#8211; Tant l&#8217;inversor com el carregador estan connectats a internet.<br> &#8211; La IP de l&#8217;inversor est\u00e0 assignada incorrectament al e-Charger.<br><br><strong>002<\/strong> Per a mesurador V2C 1.0 i 2.0: les trames arriben corruptes.<br><strong>Comprovar<\/strong>:<br>&#8211; Crimpatge correcte del connector RJ-45 en ambd\u00f3s extrems.<br>&#8211; Configuraci\u00f3 correcta del control din\u00e0mic amb el mesurador seleccionat corresponent a la instal\u00b7laci\u00f3.<br><br><strong>003<\/strong> Possible soroll en el senyal V2C ControlBox.<br><strong>Comprovar:<br><\/strong>&#8211; Crimpatge correcte del connector RJ-45 en ambd\u00f3s extrems.<br>&#8211; Configuraci\u00f3 correcta del control din\u00e0mic amb el mesurador seleccionat corresponent a la instal\u00b7laci\u00f3.<br><br><strong>004<\/strong> Trydan est\u00e0 desconnectat del WiFi i intentant reconnectar i el mesurador WiFi utilitza aquesta tecnologia WiFi per connectar-se.<br><strong>Comprovar<\/strong>:<br>&#8211; Connexi\u00f3 correcta dels dos dispositius a la mateixa WiFi del client (no al carregador)<br>&#8211; Que la intensitat del senyal sigui \u00f2ptima o millorar mitjan\u00e7ant un repetidor la connexi\u00f3 WiFi a la qual ambd\u00f3s estiguin connectats.<br><br><strong>005<\/strong> El V2C ControlBox connectat mitjan\u00e7ant RJ-45 no respon.<br><strong>Comprovar<\/strong>:<br>&#8211; Crimpatge correcte del connector RJ-45 en ambd\u00f3s extrems.<br><br><strong>006<\/strong> Es fa una petici\u00f3 HTTP i d\u00f3na fallada de connexi\u00f3 (Shelly, Solax, Kostal Piko, Enphase, P1 Meter, SAJ [Dades Solares], Wibeee). Fallada en intentar connectar al servidor Modbus TCP (Huawei, Kostal Plenticore, Fronius, Ingeteam, SMA Sunny, SolarEdge, Victron).<br><strong>Comprovar<\/strong>:<br>&#8211; Connexi\u00f3 correcta dels dos dispositius a la mateixa WiFi del client (no al carregador).<br>&#8211; La IP de l&#8217;inversor est\u00e0 assignada incorrectament al e-Charger.<br>&#8211; Que la intensitat del senyal sigui \u00f2ptima o millorar mitjan\u00e7ant un repetidor la connexi\u00f3 WiFi a la qual ambd\u00f3s estiguin connectats.<br>&#8211; Configuraci\u00f3 correcta de l&#8217;inversor respecte dels par\u00e0metres de la comunicaci\u00f3 amb Trydan.<\/p><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-71147356\"><p><strong>007<\/strong> La cerca autom\u00e0tica de Shelly no va trobar cap dispositiu.<br><strong>Comprovar<\/strong>:<br>&#8211; Canvi a IP fixa del Shelly al carregador Trydan.<br>&#8211; Connexi\u00f3 correcta dels dos dispositius a la mateixa WiFi del client (no al carregador).<br><br><strong>008<\/strong> S&#8217;ha seleccionat un mesurador amb tecnologia WiFi i Trydan mai es va connectar a la xarxa WiFi configurada.<br><strong>Comprovar<\/strong>:<br>&#8211; Connexi\u00f3 correcta dels dos dispositius a la mateixa WiFi del client amb senyal suficient (no al carregador).<br><br><strong>009 <\/strong>Es rep un Timeout de la petici\u00f3 al mesurador.<br><strong>Comprovar<\/strong>:<br>&#8211; Correcte crimpatge del connector RJ-45 en ambd\u00f3s extrems.<br>&#8211; Configuraci\u00f3 correcta de l&#8217;inversor pel que fa als par\u00e0metres de comunicaci\u00f3 amb Trydan.<br>&#8211; En el cas d&#8217;un inversor o mesurador WiFi, la connexi\u00f3 correcta dels dos dispositius a la mateixa WiFi del client amb senyal suficient (no al carregador).<br>&#8211; La IP de l&#8217;inversor i configurar-la correctament en el control din\u00e0mic de pot\u00e8ncia de Trydan.<br>&#8211; Inversor Solax: Versi\u00f3 correcta del Pocket WiFi V2.033.20 (enlla\u00e7 de desc\u00e0rrega incl\u00f2s al manual).<br><br><strong>010<\/strong> Es rep dada de pin\u00e7a no connectada en un canal que \u00e9s necessari<br>(Mono + FV pin\u00e7a 1 o 4, Trif\u00e0sic pinces 1, 2 o 3)<br><strong>Comprovar<\/strong>:<br>&#8211; Col\u00b7locaci\u00f3 correcta de les pinces en les fases indicades en l&#8217;esquema correcte d&#8217;instal\u00b7laci\u00f3 en cada cas.<\/p><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-00168f44\">\n<div class=\"wp-block-uagb-container uagb-block-c837e147\">\n<div class=\"wp-block-uagb-image aligncenter uagb-block-ded0ddba wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-center\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png ,https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png 780w, https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png\" alt=\"\" class=\"uag-image-125013\" width=\"50\" height=\"50\" title=\"\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-421a53a1\"><div class=\"wp-block-uagb-advanced-heading uagb-block-ab21f8f7\"><p class=\"uagb-heading-text\"><strong>NOTA IMPORTANT:<\/strong> Si el <strong>codi d&#8217;error \u00e9s superior a 011<\/strong>, s\u00f3n <strong>errors tipificats en el protocol MODBUS RTU o TCP. Nom\u00e9s per a personal especialitzat.<\/strong> Pots generar una sol\u00b7licitud al Centre de Suport T\u00e8cnic i ens posarem en contacte tan aviat com sigui possible.<\/p><\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-a889f73f\">\n<div class=\"wp-block-uagb-container uagb-block-3ced5973\"><p><strong>021 <\/strong> FUNCIO_IL\u00b7LEGAL<br><strong>022<\/strong> ADRE\u00c7A_DE_DADES_IL\u00b7LEGAL<br><strong>023<\/strong> VALOR_DE_DADES_IL\u00b7LEGAL<br><strong>024<\/strong> FALLIDA_DEL_DISPOSITIU_DEL_SERVIDOR<br><strong>025<\/strong> RECON\u00c8IXER<br><strong>026<\/strong> DISPOSITIU_DEL_SERVIDOR_OCUPAT<br><strong>027<\/strong> RECON\u00c8IXER_NEGATIU<br><strong>028<\/strong> ERROR_DE_PARITAT_DE_MEM\u00d2RIA<br><strong>030<\/strong> CAM\u00cd_DEL_GUARDI\u00c0_NO_DISPONIBLE<br><strong>031<\/strong> OBJECTIU_DEL_GUARDI\u00c0_SENSE_RESPONDER<br><strong>032<\/strong> RTU_DEL_SERVIDOR_INACTIU<br><strong>244<\/strong> TEMPS_EXHAURIT<br><strong>245<\/strong> SERVIDOR_INV\u00c0LID<br><strong>246<\/strong> ERROR_DE_CRC<br><strong>247<\/strong> DESCOORDINACI\u00d3_DE_FC<br><strong>248<\/strong> DESCOORDINACI\u00d3_DE_ID_DEL_SERVIDOR<br><strong>249<\/strong> ERROR_DE_LLONGITUD_DE_PAQUET<\/p><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-70caf82a\"><p><strong>250<\/strong>  ERROR_DE_COMPTADOR_DE_PAR\u00c0METRES<br><strong>251<\/strong>  ERROR_DE_L\u00cdMIT_DE_PAR\u00c0METRES<br><strong>252<\/strong>  QUEUE_DE_SOL\u00b7LICITUD_COMPLETA<br><strong>253<\/strong>  IP_O_PORT_IL\u00b7LEGAL<br><strong>254<\/strong>  FALLIDA_DE_CONEXI\u00d3_IP<br><strong>255<\/strong>  DESCOORDINACI\u00d3_TCP<br><strong>256<\/strong>  MISSATGE_BU<br><strong>275 <\/strong> ERROR_NO_DEFINIT<\/p><\/div>\n<\/div>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-c6f38013 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><div class=\"wp-block-uagb-advanced-heading uagb-block-6963d70c\"><h2 class=\"uagb-heading-text\"><strong>Necessites suport t\u00e8cnic?<\/strong><\/h2><\/div>\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-408243eb\"><p class=\"uagb-heading-text\">Resol el teu incident al moment a trav\u00e9s del nostre xat amb IA. Si no es resol, genera una sol\u00b7licitud al Centre de Suport T\u00e8cnic i ens posarem en contacte amb tu tan aviat com sigui possible per oferir-te la millor soluci\u00f3.<\/p><\/div>\n\n<div class=\"wp-block-uagb-info-box uagb-block-12e3cf1c uagb-infobox__content-wrap  uagb-infobox-icon-left uagb-infobox-left uagb-infobox-image-valign-top wp-block-uagb-info-box--has-margin ai-chatbot-button\"><div class=\"uagb-infobox-margin-wrapper\"><div class=\"uagb-ifb-image-content\"><img decoding=\"async\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2026\/01\/support-ai-chatbot.png\" alt=\"\" width=\"20\" height=\"19\" loading=\"lazy\"\/><\/div><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><\/div><div class=\"uagb-ifb-button-wrapper wp-block-button\"><a href=\"https:\/\/v2charge.com\/ca\/area-de-suport\/suport-trydan\/\" class=\"uagb-infobox-cta-link wp-block-button__link\" target=\"_blank\" rel=\"noopener noreferrer\" onclick=\"return true;\"><span class=\"uagb-inline-editing\">Pregunta al nostre xat amb IA<\/span><\/a><\/div><\/div><\/div><\/div>\n\n\n<div class=\"wp-block-uagb-buttons uagb-buttons__outer-wrap uagb-btn__default-btn uagb-btn-tablet__default-btn uagb-btn-mobile__default-btn uagb-block-ba1e67d1\"><div class=\"uagb-buttons__wrap uagb-buttons-layout-wrap \"><div class=\"wp-block-uagb-buttons-child uagb-buttons__outer-wrap uagb-block-23cfb623 wp-block-button\"><div class=\"uagb-button__wrapper\"><a class=\"uagb-buttons-repeater wp-block-button__link\" aria-label=\"\" href=\"https:\/\/v2charge.atlassian.net\/servicedesk\/customer\/portal\/3\" rel=\"follow noopener\" target=\"_blank\" role=\"button\"><div class=\"uagb-button__link\">Contacta amb Suport T\u00e8cnic<\/div><\/a><\/div><\/div><\/div><\/div>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Codis d&#8217;errors de connexi\u00f3 i la seva soluci\u00f3 Si en activar el control din\u00e0mic de pot\u00e8ncia en el carregador Trydan o Trydan Pro hi ha un error, al display del carregador apareixer\u00e0 un codi corresponent a l&#8217;error. Les solucions als errors establerts a continuaci\u00f3 corresponen a la versi\u00f3 1.6.18 o superiors. En cas de tenir &#8230; <a title=\"C\u00f2digs d&#8217;errors de connexi\u00f3 i la seva soluci\u00f3\" class=\"read-more\" href=\"https:\/\/v2charge.com\/ca\/area-de-suport\/control-de-potencia\/control-dinamic-de-potencia\/codis-errors-connexio\/\" aria-label=\"Read more about C\u00f2digs d&#8217;errors de connexi\u00f3 i la seva soluci\u00f3\">Read more<\/a><\/p>\n","protected":false},"author":400,"featured_media":170354,"parent":309971,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_eb_attr":"","content-type":"","_uag_custom_page_level_css":"","footnotes":""},"class_list":["post-310106","page","type-page","status-publish","has-post-thumbnail"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.3.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>C\u00f2digs d&#039;errors de connexi\u00f3 i la seva soluci\u00f3 - Trydan<\/title>\n<meta name=\"description\" content=\"Apareix un error de connexi\u00f3 a la pantalla de Trydan? Coneix el significat de l&#039;error i la seva soluci\u00f3 | \u00c0rea de Suport\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/v2charge.com\/ca\/area-de-suport\/control-de-potencia\/control-dinamic-de-potencia\/codis-errors-connexio\/\" \/>\n<meta property=\"og:locale\" content=\"ca_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"C\u00f2digs d&#039;errors de connexi\u00f3 i la seva soluci\u00f3 - Trydan\" \/>\n<meta property=\"og:description\" content=\"Apareix un error de connexi\u00f3 a la pantalla de Trydan? Coneix el significat de l&#039;error i la seva soluci\u00f3 | \u00c0rea de Suport\" \/>\n<meta property=\"og:url\" content=\"https:\/\/v2charge.com\/ca\/area-de-suport\/control-de-potencia\/control-dinamic-de-potencia\/codis-errors-connexio\/\" \/>\n<meta property=\"og:site_name\" content=\"V2C\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/V2C.Charge\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-13T14:45:07+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"675\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@V2C_Charge\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 minuts\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/v2charge.com\/ca\/area-de-suport\/control-de-potencia\/control-dinamic-de-potencia\/codis-errors-connexio\/\",\"url\":\"https:\/\/v2charge.com\/ca\/area-de-suport\/control-de-potencia\/control-dinamic-de-potencia\/codis-errors-connexio\/\",\"name\":\"C\u00f2digs d'errors de connexi\u00f3 i la seva soluci\u00f3 - Trydan\",\"isPartOf\":{\"@id\":\"https:\/\/v2charge.com\/ca\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/v2charge.com\/ca\/area-de-suport\/control-de-potencia\/control-dinamic-de-potencia\/codis-errors-connexio\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/v2charge.com\/ca\/area-de-suport\/control-de-potencia\/control-dinamic-de-potencia\/codis-errors-connexio\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg\",\"datePublished\":\"2024-10-04T13:39:28+00:00\",\"dateModified\":\"2026-01-13T14:45:07+00:00\",\"description\":\"Apareix un error de connexi\u00f3 a la pantalla de Trydan? Coneix el significat de l'error i la seva soluci\u00f3 | \u00c0rea de Suport\",\"breadcrumb\":{\"@id\":\"https:\/\/v2charge.com\/ca\/area-de-suport\/control-de-potencia\/control-dinamic-de-potencia\/codis-errors-connexio\/#breadcrumb\"},\"inLanguage\":\"ca\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/v2charge.com\/ca\/area-de-suport\/control-de-potencia\/control-dinamic-de-potencia\/codis-errors-connexio\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ca\",\"@id\":\"https:\/\/v2charge.com\/ca\/area-de-suport\/control-de-potencia\/control-dinamic-de-potencia\/codis-errors-connexio\/#primaryimage\",\"url\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg\",\"contentUrl\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg\",\"width\":1200,\"height\":675,\"caption\":\"V2C Electric Chargers\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/v2charge.com\/ca\/area-de-suport\/control-de-potencia\/control-dinamic-de-potencia\/codis-errors-connexio\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"V2C\",\"item\":\"https:\/\/v2charge.com\/ca\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Din\u00e1mico\",\"item\":\"https:\/\/v2charge.com\/ca\/support\/power-control\/dynamic\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"C\u00f2digs d&#8217;errors de connexi\u00f3 i la seva soluci\u00f3\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/v2charge.com\/ca\/#website\",\"url\":\"https:\/\/v2charge.com\/ca\/\",\"name\":\"V2C\",\"description\":\"#CargandoElMa\u00f1ana\",\"publisher\":{\"@id\":\"https:\/\/v2charge.com\/ca\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/v2charge.com\/ca\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ca\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/v2charge.com\/ca\/#organization\",\"name\":\"V2C\",\"url\":\"https:\/\/v2charge.com\/ca\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ca\",\"@id\":\"https:\/\/v2charge.com\/ca\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png\",\"contentUrl\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png\",\"width\":984,\"height\":431,\"caption\":\"V2C\"},\"image\":{\"@id\":\"https:\/\/v2charge.com\/ca\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/V2C.Charge\",\"https:\/\/x.com\/V2C_Charge\",\"https:\/\/www.instagram.com\/v2c.charge\/\",\"https:\/\/www.youtube.com\/@V2C\",\"https:\/\/www.linkedin.com\/company\/v2c-chargers\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"C\u00f2digs d'errors de connexi\u00f3 i la seva soluci\u00f3 - Trydan","description":"Apareix un error de connexi\u00f3 a la pantalla de Trydan? Coneix el significat de l'error i la seva soluci\u00f3 | \u00c0rea de Suport","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/v2charge.com\/ca\/area-de-suport\/control-de-potencia\/control-dinamic-de-potencia\/codis-errors-connexio\/","og_locale":"ca_ES","og_type":"article","og_title":"C\u00f2digs d'errors de connexi\u00f3 i la seva soluci\u00f3 - Trydan","og_description":"Apareix un error de connexi\u00f3 a la pantalla de Trydan? Coneix el significat de l'error i la seva soluci\u00f3 | \u00c0rea de Suport","og_url":"https:\/\/v2charge.com\/ca\/area-de-suport\/control-de-potencia\/control-dinamic-de-potencia\/codis-errors-connexio\/","og_site_name":"V2C","article_publisher":"https:\/\/www.facebook.com\/V2C.Charge","article_modified_time":"2026-01-13T14:45:07+00:00","og_image":[{"width":1200,"height":675,"url":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@V2C_Charge","twitter_misc":{"Est. reading time":"6 minuts"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/v2charge.com\/ca\/area-de-suport\/control-de-potencia\/control-dinamic-de-potencia\/codis-errors-connexio\/","url":"https:\/\/v2charge.com\/ca\/area-de-suport\/control-de-potencia\/control-dinamic-de-potencia\/codis-errors-connexio\/","name":"C\u00f2digs d'errors de connexi\u00f3 i la seva soluci\u00f3 - Trydan","isPartOf":{"@id":"https:\/\/v2charge.com\/ca\/#website"},"primaryImageOfPage":{"@id":"https:\/\/v2charge.com\/ca\/area-de-suport\/control-de-potencia\/control-dinamic-de-potencia\/codis-errors-connexio\/#primaryimage"},"image":{"@id":"https:\/\/v2charge.com\/ca\/area-de-suport\/control-de-potencia\/control-dinamic-de-potencia\/codis-errors-connexio\/#primaryimage"},"thumbnailUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","datePublished":"2024-10-04T13:39:28+00:00","dateModified":"2026-01-13T14:45:07+00:00","description":"Apareix un error de connexi\u00f3 a la pantalla de Trydan? Coneix el significat de l'error i la seva soluci\u00f3 | \u00c0rea de Suport","breadcrumb":{"@id":"https:\/\/v2charge.com\/ca\/area-de-suport\/control-de-potencia\/control-dinamic-de-potencia\/codis-errors-connexio\/#breadcrumb"},"inLanguage":"ca","potentialAction":[{"@type":"ReadAction","target":["https:\/\/v2charge.com\/ca\/area-de-suport\/control-de-potencia\/control-dinamic-de-potencia\/codis-errors-connexio\/"]}]},{"@type":"ImageObject","inLanguage":"ca","@id":"https:\/\/v2charge.com\/ca\/area-de-suport\/control-de-potencia\/control-dinamic-de-potencia\/codis-errors-connexio\/#primaryimage","url":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","contentUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","width":1200,"height":675,"caption":"V2C Electric Chargers"},{"@type":"BreadcrumbList","@id":"https:\/\/v2charge.com\/ca\/area-de-suport\/control-de-potencia\/control-dinamic-de-potencia\/codis-errors-connexio\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"V2C","item":"https:\/\/v2charge.com\/ca\/"},{"@type":"ListItem","position":2,"name":"Din\u00e1mico","item":"https:\/\/v2charge.com\/ca\/support\/power-control\/dynamic\/"},{"@type":"ListItem","position":3,"name":"C\u00f2digs d&#8217;errors de connexi\u00f3 i la seva soluci\u00f3"}]},{"@type":"WebSite","@id":"https:\/\/v2charge.com\/ca\/#website","url":"https:\/\/v2charge.com\/ca\/","name":"V2C","description":"#CargandoElMa\u00f1ana","publisher":{"@id":"https:\/\/v2charge.com\/ca\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/v2charge.com\/ca\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ca"},{"@type":"Organization","@id":"https:\/\/v2charge.com\/ca\/#organization","name":"V2C","url":"https:\/\/v2charge.com\/ca\/","logo":{"@type":"ImageObject","inLanguage":"ca","@id":"https:\/\/v2charge.com\/ca\/#\/schema\/logo\/image\/","url":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png","contentUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png","width":984,"height":431,"caption":"V2C"},"image":{"@id":"https:\/\/v2charge.com\/ca\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/V2C.Charge","https:\/\/x.com\/V2C_Charge","https:\/\/www.instagram.com\/v2c.charge\/","https:\/\/www.youtube.com\/@V2C","https:\/\/www.linkedin.com\/company\/v2c-chargers\/"]}]}},"uagb_featured_image_src":{"full":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"thumbnail":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-150x150.jpg",150,150,true],"medium":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-300x169.jpg",300,169,true],"medium_large":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-768x432.jpg",768,432,true],"large":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-1024x576.jpg",1024,576,true],"gs-tiny":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",50,28,false],"xl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxxxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxxxxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"1536x1536":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"2048x2048":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false]},"uagb_author_info":{"display_name":"V2C","author_link":"https:\/\/v2charge.com\/ca\/author\/marketing\/"},"uagb_comment_info":0,"uagb_excerpt":"Codis d&#8217;errors de connexi\u00f3 i la seva soluci\u00f3 Si en activar el control din\u00e0mic de pot\u00e8ncia en el carregador Trydan o Trydan Pro hi ha un error, al display del carregador apareixer\u00e0 un codi corresponent a l&#8217;error. Les solucions als errors establerts a continuaci\u00f3 corresponen a la versi\u00f3 1.6.18 o superiors. En cas de tenir&hellip;","_links":{"self":[{"href":"https:\/\/v2charge.com\/ca\/wp-json\/wp\/v2\/pages\/310106","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/v2charge.com\/ca\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/v2charge.com\/ca\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/v2charge.com\/ca\/wp-json\/wp\/v2\/users\/400"}],"replies":[{"embeddable":true,"href":"https:\/\/v2charge.com\/ca\/wp-json\/wp\/v2\/comments?post=310106"}],"version-history":[{"count":0,"href":"https:\/\/v2charge.com\/ca\/wp-json\/wp\/v2\/pages\/310106\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/v2charge.com\/ca\/wp-json\/wp\/v2\/pages\/309971"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/v2charge.com\/ca\/wp-json\/wp\/v2\/media\/170354"}],"wp:attachment":[{"href":"https:\/\/v2charge.com\/ca\/wp-json\/wp\/v2\/media?parent=310106"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}