{"id":338383,"date":"2024-10-04T15:39:28","date_gmt":"2024-10-04T13:39:28","guid":{"rendered":""},"modified":"2026-01-13T16:45:07","modified_gmt":"2026-01-13T14:45:07","slug":"uhendusveakoodid-ja-nende-lahendamine","status":"publish","type":"page","link":"https:\/\/v2charge.com\/et\/dunaamiline-v-imsuse-juhtimine\/uhendusveakoodid-ja-nende-lahendamine\/","title":{"rendered":"\u00dchendusveakoodid ja nende lahendamine"},"content":{"rendered":"\n<div class=\"wp-block-uagb-container uagb-block-9d828d1c alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><div class=\"yoast-breadcrumbs\"><span><span><a href=\"https:\/\/v2charge.com\/et\/\">V2C<\/a><\/span> \u00bb <span><a href=\"https:\/\/v2charge.com\/et\/dunaamiline-v-imsuse-juhtimine\/\">Din\u00e1mico<\/a><\/span> \u00bb <span class=\"breadcrumb_last\" aria-current=\"page\">\u00dchendusveakoodid ja nende lahendamine<\/span><\/span><\/div>\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-be8360a4\"><h1 class=\"uagb-heading-text\">\u00dchendusveakoodid ja nende lahendamine<\/h1><\/div>\n\n<p class=\"wp-block-paragraph\">Kui Trydan v\u00f5i Trydan Pro laadija d\u00fcnaamilise v\u00f5imsuse juhtimise aktiveerimisel ilmneb viga, kuvatakse laadija ekraanil <strong>veakood<\/strong>.<br><br>Allpool toodud vigade lahendused kehtivad <strong>versioonile 1.6.18 v\u00f5i uuematele<\/strong>. Kui teil on madalam versioon, <a href=\"https:\/\/v2charge.com\/et\/soporte\/trydan\/actualizar-ultima-version\/\"><strong>uuendage Trydan laadijat<\/strong><\/a> ja kontrollige j\u00e4rgmist loendit uuesti.<\/p><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-f83ba0fb alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-9d537ef2\">\n<div class=\"wp-block-uagb-container uagb-block-1021f2c1\">\n<div class=\"wp-block-uagb-image aligncenter uagb-block-f5b78000 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-center\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png ,https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png 780w, https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png\" alt=\"\" class=\"uag-image-125013\" width=\"50\" height=\"50\" title=\"\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-a8351972\"><div class=\"wp-block-uagb-advanced-heading uagb-block-fdcb9def\"><p class=\"uagb-heading-text\"><strong>OLULINE M\u00c4RKUS:<\/strong> need vead tulenevad suhtlusprobleemidest Trydani ja inverteri v\u00f5i m\u00f5\u00f5turi vahel ning piiravad teie s\u00f5iduki laadimist miinimumini. M\u00f5ned v\u00f5ivad tekkida, kui integreerimine toimub otse inverteriga, olgu see siis Modbusi v\u00f5i RS485 suhtluse kaudu.<br><strong>On h\u00e4davajalik tutvuda ekraanil kuvatud vea lahendusega. <\/strong>Kui viga p\u00fcsib, teavitage sellest meie tehnilise toe osakonda ja deaktiveerige d\u00fcnaamiline laadimise juhtimine, et saaksite laadida kindlaksm\u00e4\u00e4ratud fikseeritud intensiivsusega.<\/p><\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-separator uagb-block-b0f92113\"><div class=\"wp-block-uagb-separator__inner\" style=\"--my-background-image:\"><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-4d0c1e2a\">\n<div class=\"wp-block-uagb-container uagb-block-195968cb\"><table style=\"border:none;\">\n    <tr style=\"border:none;\">\n        <th style=\"border:none;\">VIGA<\/th>\n        <th style=\"border:none;\"><u>00<\/u><\/th>\n        <th style=\"border:none;\"><u>000<\/u><\/th>\n    <\/tr>\n    <tr style=\"border:none;\">\n        <td style=\"border:none;\"><\/td>\n        <td style=\"border:none;\"><center>A<\/center><\/td>\n        <td style=\"border:none;\"><center>B<\/center><\/td>\n    <\/tr>\n<\/table><\/div>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Esimene <strong>kaks numbrit<\/strong> n\u00e4itavad m\u00f5\u00f5dikut v\u00f5i inverterit, mida me kasutame. On oluline valida \u00f5ige, kui seadistatakse d\u00fcnaamilist v\u00f5imsuse juhtimist, ja kontrollida, et see oleks \u00f5ige, kui esineb viga.<\/p>\n\n\n<div class=\"wp-block-uagb-container uagb-block-8616beaf\">\n<div class=\"wp-block-uagb-container uagb-block-9f8097ef\"><p class=\"wp-block-paragraph\"><strong>Vead &#8211; A<\/strong><\/p><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-4816f3c8\"><p class=\"wp-block-paragraph\"><strong>00<\/strong>  Shelly m\u00f5\u00f5tur<br><strong>01<\/strong>  V2C ControlBox<br><strong>02<\/strong>  V2C 1.0 m\u00f5\u00f5tur<br><strong>03<\/strong>  \u00dchendus Huawei inverteriga<br><strong>04<\/strong>  \u00dchendus Solax inverteriga<br><strong>05<\/strong>  \u00dchendus Kostal inverteriga<br><strong>06<\/strong>  \u00dchendus Fronius inverteriga<br><strong>07<\/strong>  \u00dchendus Ingeteam inverteriga<br><strong>08  <\/strong>\u00dchendus Wibeee m\u00f5\u00f5turiga<br><strong>09<\/strong>  \u00dchendus Victron m\u00f5\u00f5turiga<br><strong>10<\/strong>  \u00dchendus SolarEdge inverteriga<br><strong>11<\/strong>  MQTT protokolli kasutamine<\/p><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-8ef7ba8e\"><p class=\"wp-block-paragraph\"><strong>12<\/strong> \u00dchendus Goodwe inverteriga<br><strong>13<\/strong> \u00dchendus SAJ \/ GreenHeiss inverteriga<br><strong>14<\/strong> \u00dchendus Solis inverteriga<br><strong>15<\/strong> \u00dchendus Chint DDSU666 m\u00f5\u00f5turiga<br><strong>16<\/strong> \u00dchendus Eastron m\u00f5\u00f5turiga<br><strong>17<\/strong> \u00dchendus Phoneix Contact m\u00f5\u00f5turiga<br><strong>18<\/strong> \u00dchendus Carlo Gavazzi m\u00f5\u00f5turiga<br><strong>19<\/strong> \u00dchendus SMA m\u00f5\u00f5turiga<br><strong>20<\/strong> \u00dchendus Deye \/ Turbo Energy inverteriga<br><strong>21<\/strong> \u00dchendus ENPHASE inverteriga<br><strong>22<\/strong> \u00dchendus WiFi P1 m\u00f5\u00f5turiga<br><strong>23 <\/strong>\u00dchendus Modbus&#8217;i kaudu<br><strong>25<\/strong> \u00dchendus Shelly Pro m\u00f5\u00f5turiga<br><strong>26<\/strong> \u00dchendus Growatt inverteriga<br><strong>27<\/strong> \u00dchendus Sungrow inverteriga<br><strong>28 <\/strong>\u00dchendus LINKY LORA m\u00f5\u00f5turiga<br><strong>94<\/strong> M\u00f5\u00f5t on vahemikust v\u00e4ljas Auto<br><strong>95<\/strong> M\u00f5\u00f5t on vahemikust v\u00e4ljas V\u00f5rk<br><strong>96<\/strong> M\u00f5\u00f5t on vahemikust v\u00e4ljas Maja<br><strong>97<\/strong> M\u00f5\u00f5t on vahemikust v\u00e4ljas Aku<br><strong>98 <\/strong>M\u00f5\u00f5t on vahemikust v\u00e4ljas FV<br><strong>99 <\/strong>\u00dchendus kahe Trydan laadija vahel koormuse tasakaalustamise re\u017eiimis<\/p><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-separator uagb-block-b634b355\"><div class=\"wp-block-uagb-separator__inner\" style=\"--my-background-image:\"><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><strong>Vead &#8211; B<\/strong><\/p>\n\n\n<div class=\"wp-block-uagb-container uagb-block-842d9744\">\n<div class=\"wp-block-uagb-container uagb-block-f682e240\"><p class=\"wp-block-paragraph\"><strong>000<\/strong>&nbsp;M\u00f5\u00f5dud on v\u00e4ljaspool vahemikku.<br><strong><strong>Kontrollige<\/strong><\/strong>:<br>&#8211; Kas laadijal on sisemine m\u00f5\u00f5tur. Kontrollige marki, kas see on \u00fchefaasiline v\u00f5i kolmefaasiline, ja seadistage see laadijal nuppudelt, v\u00f5i v\u00f5tke \u00fchendust toega, et seadistada see kaugjuhtimise teel, kui laadija on online.<br>&#8211; M\u00f5\u00f5turi \u00f5ige f\u00fc\u00fcsiline \u00fchendamine toiteplaadiga.<br><br><strong><strong>001<\/strong> <\/strong>Goodwe seadmete jaoks UDP protokolliga<strong><br><strong>Kontrollige<\/strong><\/strong>:<br>&#8211; Nii inverter kui laadija on \u00fchendatud internetiga.<br>&#8211; Inverteri IP on e-Chargeris valesti m\u00e4\u00e4ratud.<br><br><strong>002<\/strong> V2C 1.0 ja 2.0 m\u00f5\u00f5turi jaoks: andmepaketid j\u00f5uavad rikutud kujul.<br><strong>Kontrollige<\/strong>:<br>&#8211; RJ-45 \u00fchenduse \u00f5ige krimpeerimine m\u00f5lemal pool.<br>&#8211; \u00d5ige d\u00fcnaamilise juhtimise seadistamine valitud m\u00f5\u00f5turiga, mis vastab paigaldamisele.<br><br><strong>003<\/strong> V2C ControlBoxi signaalis v\u00f5ib olla m\u00fcra.<br><strong>Kontrollige:<br><\/strong>&#8211; RJ-45 \u00fchenduse \u00f5ige krimpeerimine m\u00f5lemal pool.<br>&#8211; \u00d5ige d\u00fcnaamilise juhtimise seadistamine valitud m\u00f5\u00f5turiga, mis vastab paigaldamisele.<br><br><strong>004<\/strong> Trydan on WiFi-st lahti \u00fchendatud ja \u00fcritab uuesti \u00fchenduda ning m\u00f5\u00f5tur kasutab selleks WiFi tehnoloogiat.<br><strong>Kontrollige<\/strong>:<br>&#8211; M\u00f5lema seadme \u00f5ige \u00fchendamine kliendi sama WiFi-ga (mitte laadijaga)<br>&#8211; Et signaali intensiivsus oleks optimaalne v\u00f5i parandada \u00fchendust, kasutades kordajat, et m\u00f5lemad oleksid \u00fchendatud.<br><br><strong>005<\/strong> V2C ControlBox, mis on \u00fchendatud RJ-45 kaudu, ei reageeri.<br><strong>Kontrollige<\/strong>:<br>&#8211; RJ-45 \u00fchenduse \u00f5ige krimpeerimine m\u00f5lemal pool.<br><br><strong>006<\/strong> Tehakse HTTP-p\u00e4ring ja \u00fchenduse viga (Shelly, Solax, Kostal Piko, Enphase, P1 Meter, SAJ [P\u00e4ikesedatad], Wibeee). Eba\u00f5nnestub \u00fchenduse loomine Modbus TCP serveriga (Huawei, Kostal Plenticore, Fronius, Ingeteam, SMA Sunny, SolarEdge, Victron).<br><strong>Kontrollige<\/strong>:<br>&#8211; M\u00f5lema seadme \u00f5ige \u00fchendamine kliendi sama WiFi-ga (mitte laadijaga).<br>&#8211; Inverteri IP on e-Chargeris valesti m\u00e4\u00e4ratud.<br>&#8211; Et signaali intensiivsus oleks optimaalne v\u00f5i parandada \u00fchendust, kasutades kordajat, et m\u00f5lemad oleksid \u00fchendatud.<br>&#8211; Inverteri \u00f5ige seadistamine Trydaniga suhtlemise parameetrite osas.<\/p><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-71147356\"><p class=\"wp-block-paragraph\"><strong>007<\/strong> Shelly automaatne otsing ei leidnud \u00fchtegi seadet.<br><strong>Kontrollige<\/strong>:<br>&#8211; Shelly fikseeritud IP muutmine Trydan laadijas.<br>&#8211; M\u00f5lema seadme \u00f5ige \u00fchendamine kliendi sama WiFi-ga (mitte laadijaga).<br><br><strong>008<\/strong> On valitud WiFi tehnoloogiaga m\u00f5\u00f5tja ja Trydan ei ole kunagi \u00fchendatud seadistatud WiFi-v\u00f5rguga.<br><strong>Kontrollige<\/strong>:<br>&#8211; M\u00f5lema seadme \u00f5ige \u00fchendamine kliendi sama WiFi-ga piisava signaaliga (mitte laadijaga).<br><br><strong>009 <\/strong>Saadakse m\u00f5\u00f5tja p\u00e4ringu aegumine.<br><strong>Kontrollige<\/strong>:<br>&#8211; RJ-45 \u00fchenduse \u00f5ige krimpimine m\u00f5lemal pool.<br>&#8211; Inverteri \u00f5ige seadistamine Trydaniga suhtlemise parameetrite osas.<br>&#8211; WiFi inverteri v\u00f5i m\u00f5\u00f5tja puhul m\u00f5lema seadme \u00f5ige \u00fchendamine kliendi sama WiFi-ga piisava signaaliga (mitte laadijaga).<br>&#8211; Inverteri IP ja selle \u00f5ige seadistamine Trydan d\u00fcnaamilise v\u00f5imsuse juhtimises.<br>&#8211; Solax inverter: \u00d5ige versioon Pocket WiFi V2.033.20 (allalaadimise link on manuaalis).<br><br><strong>010<\/strong> Saadakse andmed mitte\u00fchendatud klambri kohta kanalil, mis on vajalik<br>(Mono + FV klamber 1 v\u00f5i 4, Trifaasne klambrid 1, 2 v\u00f5i 3)<br><strong>Kontrollige<\/strong>:<br>&#8211; Klambri \u00f5ige paigutamine etten\u00e4htud faasides vastavalt igas konkreetses juhtumis \u00f5igele paigaldusskeemile.<\/p><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-00168f44\">\n<div class=\"wp-block-uagb-container uagb-block-c837e147\">\n<div class=\"wp-block-uagb-image aligncenter uagb-block-ded0ddba wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-center\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png ,https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png 780w, https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png\" alt=\"\" class=\"uag-image-125013\" width=\"50\" height=\"50\" title=\"\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-421a53a1\"><div class=\"wp-block-uagb-advanced-heading uagb-block-ab21f8f7\"><p class=\"uagb-heading-text\"><strong>T\u00c4HTIS M\u00c4RKUS:<\/strong> Kui <strong>veakood on suurem kui 011<\/strong>, siis on tegu <strong>MODBUS RTU v\u00f5i TCP protokollis m\u00e4\u00e4ratletud vigadega. Ainult spetsialiseeritud personali jaoks.<\/strong> Saate luua taotluse Tehnilise Toe Keskuses ja v\u00f5tame teiega peagi \u00fchendust.<\/p><\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-a889f73f\">\n<div class=\"wp-block-uagb-container uagb-block-3ced5973\"><p class=\"wp-block-paragraph\"><strong>021 <\/strong> EBASE_ADRESS<br><strong>022<\/strong> EBASE_ANDMED<br><strong>023<\/strong> EBASE_V\u00c4\u00c4RTUS<br><strong>024<\/strong> SERVERI_SEADE_VIGA<br><strong>025<\/strong> KINNITUS<br><strong>026<\/strong> SERVERI_SEADE_KUULAMINE<br><strong>027<\/strong> NEGATIIVNE_KINNITUS<br><strong>028<\/strong> M\u00c4LU_PARITEEDI_VIGA<br><strong>030<\/strong> GATEWAY_REEGA_EI_OLLA<br><strong>031<\/strong> GATEWAY_EESM\u00c4RK_ILMA_REAKTSIOONITA<br><strong>032<\/strong> SERVER_RTU_PASSIIVNE<br><strong>244<\/strong> AEG_AEG<br><strong>245<\/strong> KEHTETU_SERVER<br><strong>246<\/strong> CRC_VIGA<br><strong>247<\/strong> FC_EBAK\u00d5LA<br><strong>248<\/strong> SERVERI_ID_EBAK\u00d5LA<br><strong>249<\/strong> PAKETI_PIKKUSE_VIGA<\/p><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-70caf82a\"><p class=\"wp-block-paragraph\"><strong>250<\/strong>  PARAMEETRI_ARV_VIGA<br><strong>251<\/strong>  PARAMEETRI_PIIR_VIGA<br><strong>252<\/strong>  P\u00c4RINGU_JARJESTUS_T\u00c4IS<br><strong>253<\/strong>  EBA\u00d5IGLANE_IP_V\u00d5I_PORT<br><strong>254<\/strong>  IP_SEOS_EBA\u00d5NNESTUS<br><strong>255<\/strong>  TCP_PEALKIRI_EBA\u00dcHILDUVUS<br><strong>256<\/strong>  T\u00dcHI_S\u00d5NUM<br><strong>275 <\/strong> M\u00c4\u00c4RATLEMATA_VIGA<\/p><\/div>\n<\/div>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-c6f38013 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><div class=\"wp-block-uagb-advanced-heading uagb-block-6963d70c\"><h2 class=\"uagb-heading-text\"><strong>Kas vajad tehnilist tuge?<\/strong><\/h2><\/div>\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-408243eb\"><p class=\"uagb-heading-text\">Lahenda oma probleem koheselt meie IA vestluse kaudu. Kui see ei lahene, loo taotlus Tehnilise Toe Keskuses ja v\u00f5tame sinuga \u00fchendust niipea kui v\u00f5imalik, et pakkuda parimat lahendust.<\/p><\/div>\n\n<div class=\"wp-block-uagb-info-box uagb-block-12e3cf1c uagb-infobox__content-wrap  uagb-infobox-icon-left uagb-infobox-left uagb-infobox-image-valign-top wp-block-uagb-info-box--has-margin ai-chatbot-button\"><div class=\"uagb-infobox-margin-wrapper\"><div class=\"uagb-ifb-image-content\"><img decoding=\"async\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2026\/01\/support-ai-chatbot.png\" alt=\"\" width=\"20\" height=\"19\" loading=\"lazy\"\/><\/div><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><\/div><div class=\"uagb-ifb-button-wrapper wp-block-button\"><a href=\"https:\/\/v2charge.com\/v2c-support-web\/\" class=\"uagb-infobox-cta-link wp-block-button__link\" target=\"_blank\" rel=\"noopener noreferrer\" onclick=\"return true;\"><span class=\"uagb-inline-editing\">K\u00fcsi meie IA vestlusrobotilt<\/span><\/a><\/div><\/div><\/div><\/div>\n\n\n<div class=\"wp-block-uagb-buttons uagb-buttons__outer-wrap uagb-btn__default-btn uagb-btn-tablet__default-btn uagb-btn-mobile__default-btn uagb-block-ba1e67d1\"><div class=\"uagb-buttons__wrap uagb-buttons-layout-wrap \"><div class=\"wp-block-uagb-buttons-child uagb-buttons__outer-wrap uagb-block-23cfb623 wp-block-button\"><div class=\"uagb-button__wrapper\"><a class=\"uagb-buttons-repeater wp-block-button__link\" aria-label=\"\" href=\"https:\/\/v2charge.atlassian.net\/servicedesk\/customer\/portal\/3\" rel=\"follow noopener\" target=\"_blank\" role=\"button\"><div class=\"uagb-button__link\">V\u00f5ta \u00fchendust tehnilise toega<\/div><\/a><\/div><\/div><\/div><\/div>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u00dchendusveakoodid ja nende lahendamine Kui Trydan v\u00f5i Trydan Pro laadija d\u00fcnaamilise v\u00f5imsuse juhtimise aktiveerimisel ilmneb viga, kuvatakse laadija ekraanil veakood. Allpool toodud vigade lahendused kehtivad versioonile 1.6.18 v\u00f5i uuematele. Kui teil on madalam versioon, uuendage Trydan laadijat ja kontrollige j\u00e4rgmist loendit uuesti. OLULINE M\u00c4RKUS: need vead tulenevad suhtlusprobleemidest Trydani ja inverteri v\u00f5i m\u00f5\u00f5turi vahel ning &#8230; <a title=\"\u00dchendusveakoodid ja nende lahendamine\" class=\"read-more\" href=\"https:\/\/v2charge.com\/et\/dunaamiline-v-imsuse-juhtimine\/uhendusveakoodid-ja-nende-lahendamine\/\" aria-label=\"Read more about \u00dchendusveakoodid ja nende lahendamine\">Read more<\/a><\/p>\n","protected":false},"author":400,"featured_media":170354,"parent":337614,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_eb_attr":"","content-type":"","_uag_custom_page_level_css":"","footnotes":""},"class_list":["post-338383","page","type-page","status-publish","has-post-thumbnail"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.3.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>\u00dchendusveakoodid ja nende lahendamine - Trydan<\/title>\n<meta name=\"description\" content=\"Kas Trydani ekraanil ilmneb \u00fchenduse viga? Tutvu vea t\u00e4henduse ja lahendusega | Toetuse ala\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/v2charge.com\/et\/dunaamiline-v-imsuse-juhtimine\/uhendusveakoodid-ja-nende-lahendamine\/\" \/>\n<meta property=\"og:locale\" content=\"et_EE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u00dchendusveakoodid ja nende lahendamine - Trydan\" \/>\n<meta property=\"og:description\" content=\"Kas Trydani ekraanil ilmneb \u00fchenduse viga? Tutvu vea t\u00e4henduse ja lahendusega | Toetuse ala\" \/>\n<meta property=\"og:url\" content=\"https:\/\/v2charge.com\/et\/dunaamiline-v-imsuse-juhtimine\/uhendusveakoodid-ja-nende-lahendamine\/\" \/>\n<meta property=\"og:site_name\" content=\"V2C\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/V2C.Charge\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-13T14:45:07+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"675\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@V2C_Charge\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 minutit\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/v2charge.com\/et\/dunaamiline-v-imsuse-juhtimine\/uhendusveakoodid-ja-nende-lahendamine\/\",\"url\":\"https:\/\/v2charge.com\/et\/dunaamiline-v-imsuse-juhtimine\/uhendusveakoodid-ja-nende-lahendamine\/\",\"name\":\"\u00dchendusveakoodid ja nende lahendamine - Trydan\",\"isPartOf\":{\"@id\":\"https:\/\/v2charge.com\/et\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/v2charge.com\/et\/dunaamiline-v-imsuse-juhtimine\/uhendusveakoodid-ja-nende-lahendamine\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/v2charge.com\/et\/dunaamiline-v-imsuse-juhtimine\/uhendusveakoodid-ja-nende-lahendamine\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg\",\"datePublished\":\"2024-10-04T13:39:28+00:00\",\"dateModified\":\"2026-01-13T14:45:07+00:00\",\"description\":\"Kas Trydani ekraanil ilmneb \u00fchenduse viga? Tutvu vea t\u00e4henduse ja lahendusega | Toetuse ala\",\"breadcrumb\":{\"@id\":\"https:\/\/v2charge.com\/et\/dunaamiline-v-imsuse-juhtimine\/uhendusveakoodid-ja-nende-lahendamine\/#breadcrumb\"},\"inLanguage\":\"et\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/v2charge.com\/et\/dunaamiline-v-imsuse-juhtimine\/uhendusveakoodid-ja-nende-lahendamine\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"et\",\"@id\":\"https:\/\/v2charge.com\/et\/dunaamiline-v-imsuse-juhtimine\/uhendusveakoodid-ja-nende-lahendamine\/#primaryimage\",\"url\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg\",\"contentUrl\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg\",\"width\":1200,\"height\":675,\"caption\":\"V2C Electric Chargers\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/v2charge.com\/et\/dunaamiline-v-imsuse-juhtimine\/uhendusveakoodid-ja-nende-lahendamine\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"V2C\",\"item\":\"https:\/\/v2charge.com\/et\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Din\u00e1mico\",\"item\":\"https:\/\/v2charge.com\/et\/dunaamiline-v-imsuse-juhtimine\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"\u00dchendusveakoodid ja nende lahendamine\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/v2charge.com\/et\/#website\",\"url\":\"https:\/\/v2charge.com\/et\/\",\"name\":\"V2C\",\"description\":\"#CargandoElMa\u00f1ana\",\"publisher\":{\"@id\":\"https:\/\/v2charge.com\/et\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/v2charge.com\/et\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"et\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/v2charge.com\/et\/#organization\",\"name\":\"V2C\",\"url\":\"https:\/\/v2charge.com\/et\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"et\",\"@id\":\"https:\/\/v2charge.com\/et\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png\",\"contentUrl\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png\",\"width\":984,\"height\":431,\"caption\":\"V2C\"},\"image\":{\"@id\":\"https:\/\/v2charge.com\/et\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/V2C.Charge\",\"https:\/\/x.com\/V2C_Charge\",\"https:\/\/www.instagram.com\/v2c.charge\/\",\"https:\/\/www.youtube.com\/@V2C\",\"https:\/\/www.linkedin.com\/company\/v2c-chargers\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u00dchendusveakoodid ja nende lahendamine - Trydan","description":"Kas Trydani ekraanil ilmneb \u00fchenduse viga? Tutvu vea t\u00e4henduse ja lahendusega | Toetuse ala","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/v2charge.com\/et\/dunaamiline-v-imsuse-juhtimine\/uhendusveakoodid-ja-nende-lahendamine\/","og_locale":"et_EE","og_type":"article","og_title":"\u00dchendusveakoodid ja nende lahendamine - Trydan","og_description":"Kas Trydani ekraanil ilmneb \u00fchenduse viga? Tutvu vea t\u00e4henduse ja lahendusega | Toetuse ala","og_url":"https:\/\/v2charge.com\/et\/dunaamiline-v-imsuse-juhtimine\/uhendusveakoodid-ja-nende-lahendamine\/","og_site_name":"V2C","article_publisher":"https:\/\/www.facebook.com\/V2C.Charge","article_modified_time":"2026-01-13T14:45:07+00:00","og_image":[{"width":1200,"height":675,"url":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@V2C_Charge","twitter_misc":{"Est. reading time":"6 minutit"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/v2charge.com\/et\/dunaamiline-v-imsuse-juhtimine\/uhendusveakoodid-ja-nende-lahendamine\/","url":"https:\/\/v2charge.com\/et\/dunaamiline-v-imsuse-juhtimine\/uhendusveakoodid-ja-nende-lahendamine\/","name":"\u00dchendusveakoodid ja nende lahendamine - Trydan","isPartOf":{"@id":"https:\/\/v2charge.com\/et\/#website"},"primaryImageOfPage":{"@id":"https:\/\/v2charge.com\/et\/dunaamiline-v-imsuse-juhtimine\/uhendusveakoodid-ja-nende-lahendamine\/#primaryimage"},"image":{"@id":"https:\/\/v2charge.com\/et\/dunaamiline-v-imsuse-juhtimine\/uhendusveakoodid-ja-nende-lahendamine\/#primaryimage"},"thumbnailUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","datePublished":"2024-10-04T13:39:28+00:00","dateModified":"2026-01-13T14:45:07+00:00","description":"Kas Trydani ekraanil ilmneb \u00fchenduse viga? Tutvu vea t\u00e4henduse ja lahendusega | Toetuse ala","breadcrumb":{"@id":"https:\/\/v2charge.com\/et\/dunaamiline-v-imsuse-juhtimine\/uhendusveakoodid-ja-nende-lahendamine\/#breadcrumb"},"inLanguage":"et","potentialAction":[{"@type":"ReadAction","target":["https:\/\/v2charge.com\/et\/dunaamiline-v-imsuse-juhtimine\/uhendusveakoodid-ja-nende-lahendamine\/"]}]},{"@type":"ImageObject","inLanguage":"et","@id":"https:\/\/v2charge.com\/et\/dunaamiline-v-imsuse-juhtimine\/uhendusveakoodid-ja-nende-lahendamine\/#primaryimage","url":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","contentUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","width":1200,"height":675,"caption":"V2C Electric Chargers"},{"@type":"BreadcrumbList","@id":"https:\/\/v2charge.com\/et\/dunaamiline-v-imsuse-juhtimine\/uhendusveakoodid-ja-nende-lahendamine\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"V2C","item":"https:\/\/v2charge.com\/et\/"},{"@type":"ListItem","position":2,"name":"Din\u00e1mico","item":"https:\/\/v2charge.com\/et\/dunaamiline-v-imsuse-juhtimine\/"},{"@type":"ListItem","position":3,"name":"\u00dchendusveakoodid ja nende lahendamine"}]},{"@type":"WebSite","@id":"https:\/\/v2charge.com\/et\/#website","url":"https:\/\/v2charge.com\/et\/","name":"V2C","description":"#CargandoElMa\u00f1ana","publisher":{"@id":"https:\/\/v2charge.com\/et\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/v2charge.com\/et\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"et"},{"@type":"Organization","@id":"https:\/\/v2charge.com\/et\/#organization","name":"V2C","url":"https:\/\/v2charge.com\/et\/","logo":{"@type":"ImageObject","inLanguage":"et","@id":"https:\/\/v2charge.com\/et\/#\/schema\/logo\/image\/","url":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png","contentUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png","width":984,"height":431,"caption":"V2C"},"image":{"@id":"https:\/\/v2charge.com\/et\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/V2C.Charge","https:\/\/x.com\/V2C_Charge","https:\/\/www.instagram.com\/v2c.charge\/","https:\/\/www.youtube.com\/@V2C","https:\/\/www.linkedin.com\/company\/v2c-chargers\/"]}]}},"uagb_featured_image_src":{"full":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"thumbnail":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-150x150.jpg",150,150,true],"medium":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-300x169.jpg",300,169,true],"medium_large":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-768x432.jpg",768,432,true],"large":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-1024x576.jpg",1024,576,true],"gs-tiny":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",50,28,false],"xl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxxxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxxxxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"1536x1536":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"2048x2048":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false]},"uagb_author_info":{"display_name":"V2C","author_link":"https:\/\/v2charge.com\/et\/author\/marketing\/"},"uagb_comment_info":0,"uagb_excerpt":"\u00dchendusveakoodid ja nende lahendamine Kui Trydan v\u00f5i Trydan Pro laadija d\u00fcnaamilise v\u00f5imsuse juhtimise aktiveerimisel ilmneb viga, kuvatakse laadija ekraanil veakood. Allpool toodud vigade lahendused kehtivad versioonile 1.6.18 v\u00f5i uuematele. Kui teil on madalam versioon, uuendage Trydan laadijat ja kontrollige j\u00e4rgmist loendit uuesti. OLULINE M\u00c4RKUS: need vead tulenevad suhtlusprobleemidest Trydani ja inverteri v\u00f5i m\u00f5\u00f5turi vahel ning&hellip;","_links":{"self":[{"href":"https:\/\/v2charge.com\/et\/wp-json\/wp\/v2\/pages\/338383","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/v2charge.com\/et\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/v2charge.com\/et\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/v2charge.com\/et\/wp-json\/wp\/v2\/users\/400"}],"replies":[{"embeddable":true,"href":"https:\/\/v2charge.com\/et\/wp-json\/wp\/v2\/comments?post=338383"}],"version-history":[{"count":0,"href":"https:\/\/v2charge.com\/et\/wp-json\/wp\/v2\/pages\/338383\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/v2charge.com\/et\/wp-json\/wp\/v2\/pages\/337614"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/v2charge.com\/et\/wp-json\/wp\/v2\/media\/170354"}],"wp:attachment":[{"href":"https:\/\/v2charge.com\/et\/wp-json\/wp\/v2\/media?parent=338383"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}