{"id":311495,"date":"2024-10-04T15:39:28","date_gmt":"2024-10-04T13:39:28","guid":{"rendered":""},"modified":"2026-01-13T16:45:07","modified_gmt":"2026-01-13T14:45:07","slug":"yhteysvirhekoodit-ja-niiden-ratkaisut","status":"publish","type":"page","link":"https:\/\/v2charge.com\/fi\/tukialue\/tehonhallinta\/dynaaminen-tehohallinta\/yhteysvirhekoodit-ja-niiden-ratkaisut\/","title":{"rendered":"Yhteysvirhekoodit ja niiden ratkaisut"},"content":{"rendered":"\n<div class=\"wp-block-uagb-container uagb-block-9d828d1c alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><div class=\"yoast-breadcrumbs\"><span><span><a href=\"https:\/\/v2charge.com\/fi\/\">V2C<\/a><\/span> \u00bb <span><a href=\"https:\/\/v2charge.com\/fi\/dynaaminen-tehohallinta\/\">Din\u00e1mico<\/a><\/span> \u00bb <span class=\"breadcrumb_last\" aria-current=\"page\">Yhteysvirhekoodit ja niiden ratkaisut<\/span><\/span><\/div>\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-be8360a4\"><h1 class=\"uagb-heading-text\">Yhteysvirhekoodit ja niiden ratkaisut<\/h1><\/div>\n\n<p>Jos Trydan- tai Trydan Pro-laturin dynaamisen teho-ohjauksen aktivoinnissa ilmenee virhe, laturin n\u00e4yt\u00f6lle ilmestyy <strong>virhekoodi<\/strong>.<br><br>Alla olevat ratkaisut virheisiin koskevat <strong>versiota 1.6.18 tai uudempi<\/strong>. Jos sinulla on vanhempi versio, <a href=\"https:\/\/v2charge.com\/fi\/tukialue\/trydan-tuki\/paivita-viimeisin-versio-e-charger-trydanista\/\"><strong>p\u00e4ivit\u00e4 Trydan-laturi<\/strong><\/a> ja tarkista seuraava lista uudelleen.<\/p><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-f83ba0fb alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-9d537ef2\">\n<div class=\"wp-block-uagb-container uagb-block-1021f2c1\">\n<div class=\"wp-block-uagb-image aligncenter uagb-block-f5b78000 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-center\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png ,https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png 780w, https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png\" alt=\"\" class=\"uag-image-125013\" width=\"50\" height=\"50\" title=\"\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-a8351972\"><div class=\"wp-block-uagb-advanced-heading uagb-block-fdcb9def\"><p class=\"uagb-heading-text\"><strong>T\u00c4RKE\u00c4 HUOMAUTUS:<\/strong> n\u00e4m\u00e4 virheet johtuvat viestint\u00e4ongelmasta Trydanin ja invertterin tai mittarin v\u00e4lill\u00e4 ja rajoittavat ajoneuvosi latausta minimitasolle. Joitakin voi esiinty\u00e4, kun integraatio on suora invertterin kanssa, joko Modbus- tai RS485-viestinn\u00e4n kautta.<br><strong>On v\u00e4ltt\u00e4m\u00e4t\u00f6nt\u00e4 tarkistaa n\u00e4yt\u00f6ll\u00e4 n\u00e4kyv\u00e4n virheen ratkaisu.<\/strong> Jos virhe jatkuu, ilmoita siit\u00e4 tekniseen tukeemme ja poista dynaaminen latauksen hallinta, jotta voit ladata asetetulla kiinte\u00e4ll\u00e4 voimakkuudella.<\/p><\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-separator uagb-block-b0f92113\"><div class=\"wp-block-uagb-separator__inner\" style=\"--my-background-image:\"><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-4d0c1e2a\">\n<div class=\"wp-block-uagb-container uagb-block-195968cb\"><table style=\"border:none;\">\n    <tr style=\"border:none;\">\n        <th style=\"border:none;\">VIRHE<\/th>\n        <th style=\"border:none;\"><u>00<\/u><\/th>\n        <th style=\"border:none;\"><u>000<\/u><\/th>\n    <\/tr>\n    <tr style=\"border:none;\">\n        <td style=\"border:none;\"><\/td>\n        <td style=\"border:none;\"><center>A<\/center><\/td>\n        <td style=\"border:none;\"><center>B<\/center><\/td>\n    <\/tr>\n<\/table><\/div>\n<\/div>\n\n\n<p>Ensimm\u00e4iset <strong>kaksi numeroa<\/strong> osoittavat mittarin tai muuntajan, jota k\u00e4yt\u00e4mme. On t\u00e4rke\u00e4\u00e4 valita oikea, kun asetetaan dynaamista tehohallintaa, ja tarkistaa, ett\u00e4 se on oikein virhetilanteessa.<\/p>\n\n\n<div class=\"wp-block-uagb-container uagb-block-8616beaf\">\n<div class=\"wp-block-uagb-container uagb-block-9f8097ef\"><p><strong>Virheet &#8211; A<\/strong><\/p><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-4816f3c8\"><p><strong>00<\/strong>  Shelly-mittari<br><strong>01<\/strong>  V2C ControlBox<br><strong>02<\/strong>  V2C 1.0 -mittari<br><strong>03<\/strong>  Yhteys Huawei-invertteriin<br><strong>04<\/strong>  Yhteys Solax-invertteriin<br><strong>05<\/strong>  Yhteys Kostal-invertteriin<br><strong>06<\/strong>  Yhteys Fronius-invertteriin<br><strong>07<\/strong>  Yhteys Ingeteam-invertteriin<br><strong>08  <\/strong>Yhteys Wibeee-mittariin<br><strong>09<\/strong>  Yhteys Victron-mittariin<br><strong>10<\/strong>  Yhteys SolarEdge-invertteriin<br><strong>11<\/strong>  MQTT-protokollan k\u00e4ytt\u00f6<\/p><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-8ef7ba8e\"><p><strong>12<\/strong> Yhteys Goodwe-invertteriin<br><strong>13<\/strong> Yhteys SAJ \/ GreenHeiss -invertteriin<br><strong>14<\/strong> Yhteys Solis-invertteriin<br><strong>15<\/strong> Yhteys Chint DDSU666 -mittariin<br><strong>16<\/strong> Yhteys Eastron-mittariin<br><strong>17<\/strong> Yhteys Phoneix Contact -mittariin<br><strong>18<\/strong> Yhteys Carlo Gavazzi -mittariin<br><strong>19<\/strong> Yhteys SMA-mittariin<br><strong>20<\/strong> Yhteys Deye \/ Turbo Energy -invertteriin<br><strong>21<\/strong> Yhteys ENPHASE-invertteriin<br><strong>22<\/strong> Yhteys WiFi P1 -mittariin<br><strong>23 <\/strong>Yhteys Modbusin kautta<br><strong>25<\/strong> Yhteys Shelly Pro -mittariin<br><strong>26<\/strong> Yhteys Growatt-invertteriin<br><strong>27<\/strong> Yhteys Sungrow-invertteriin<br><strong>28 <\/strong>Yhteys LINKY LORA -mittariin<br><strong>94<\/strong> Mittaus ulkopuolella alueen auto<br><strong>95<\/strong> Mittaus ulkopuolella alueen verkko<br><strong>96<\/strong> Mittaus ulkopuolella alueen talo<br><strong>97<\/strong> Mittaus ulkopuolella alueen akku<br><strong>98 <\/strong>Mittaus ulkopuolella alueen FV<br><strong>99 <\/strong>Yhteys kahden Trydan-laturin v\u00e4lill\u00e4 kuormituksen tasapainotustilassa<\/p><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-separator uagb-block-b634b355\"><div class=\"wp-block-uagb-separator__inner\" style=\"--my-background-image:\"><\/div><\/div>\n\n\n<p><strong>Virheet &#8211; B<\/strong><\/p>\n\n\n<div class=\"wp-block-uagb-container uagb-block-842d9744\">\n<div class=\"wp-block-uagb-container uagb-block-f682e240\"><p><strong>000<\/strong>&nbsp;Mittaukset ovat alueen ulkopuolella.<br><strong><strong>Tarkista<\/strong><\/strong>:<br>&#8211; Onko laturissa sis\u00e4inen mittari. Tarkista merkki, onko se yksivaiheinen vai kolmivaiheinen, ja m\u00e4\u00e4rit\u00e4 se laturissa painikelaudasta, tai ota yhteytt\u00e4 tukeen, jotta se voidaan m\u00e4\u00e4ritt\u00e4\u00e4 et\u00e4n\u00e4, jos laturi on verkossa.<br>&#8211; Mittarin oikea fyysinen liit\u00e4nt\u00e4 tehopiiriin.<br><br><strong><strong>001<\/strong> <\/strong>Goodwe-laitteille, joissa on UDP-protokolla<strong><br><strong>Tarkista<\/strong><\/strong>:<br>&#8211; Sek\u00e4 invertteri ett\u00e4 laturi ovat yhteydess\u00e4 internetiin.<br> &#8211; Invertterin IP-osoite on m\u00e4\u00e4ritetty v\u00e4\u00e4rin e-Chargerissa.<br><br><strong>002<\/strong> V2C 1.0 ja 2.0 mittarille: tiedot saapuvat vaurioituneina.<br><strong>Tarkista<\/strong>:<br>&#8211; RJ-45-liittimen oikea puristus molemmissa p\u00e4iss\u00e4.<br>&#8211; Oikea dynaamisen ohjauksen m\u00e4\u00e4ritt\u00e4minen valitulle mittarille, joka vastaa asennusta.<br><br><strong>003<\/strong> Mahdollista h\u00e4iri\u00f6t\u00e4 V2C ControlBoxin signaalissa.<br><strong>Tarkista:<br><\/strong>&#8211; RJ-45-liittimen oikea puristus molemmissa p\u00e4iss\u00e4.<br>&#8211; Oikea dynaamisen ohjauksen m\u00e4\u00e4ritt\u00e4minen valitulle mittarille, joka vastaa asennusta.<br><br><strong>004<\/strong> Trydan on irrotettu WiFi:st\u00e4 ja yritt\u00e4\u00e4 yhdist\u00e4\u00e4 uudelleen, ja WiFi-mittari k\u00e4ytt\u00e4\u00e4 t\u00e4t\u00e4 WiFi-teknologiaa yhdist\u00e4\u00e4kseen.<br><strong>Tarkista<\/strong>:<br>&#8211; Molempien laitteiden oikea liit\u00e4nt\u00e4 asiakkaan samaan WiFi-verkkoon (ei laturiin)<br>&#8211; Signaalin voimakkuuden tulee olla optimaalinen tai parantaa WiFi-yhteytt\u00e4, johon molemmat ovat kytkettyin\u00e4, toistimen avulla.<br><br><strong>005<\/strong> V2C ControlBox, joka on kytketty RJ-45:ll\u00e4, ei vastaa.<br><strong>Tarkista<\/strong>:<br>&#8211; RJ-45-liittimen oikea puristus molemmissa p\u00e4iss\u00e4.<br><br><strong>006<\/strong> Tehd\u00e4\u00e4n HTTP-pyynt\u00f6 ja yhteys ep\u00e4onnistuu (Shelly, Solax, Kostal Piko, Enphase, P1 Meter, SAJ [Aurinkotiedot], Wibeee). Yhteys Modbus TCP -palvelimeen ep\u00e4onnistuu (Huawei, Kostal Plenticore, Fronius, Ingeteam, SMA Sunny, SolarEdge, Victron).<br><strong>Tarkista<\/strong>:<br>&#8211; Molempien laitteiden oikea liit\u00e4nt\u00e4 asiakkaan samaan WiFi-verkkoon (ei laturiin).<br>&#8211; Invertterin IP-osoite on m\u00e4\u00e4ritetty v\u00e4\u00e4rin e-Chargerissa.<br>&#8211; Signaalin voimakkuuden tulee olla optimaalinen tai parantaa WiFi-yhteytt\u00e4, johon molemmat ovat kytkettyin\u00e4, toistimen avulla.<br>&#8211; Oikea invertterin m\u00e4\u00e4ritt\u00e4minen suhteessa Trydanin viestint\u00e4parametreihin.<\/p><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-71147356\"><p><strong>007<\/strong> Shellyn automaattinen haku ei l\u00f6yt\u00e4nyt laitetta.<br><strong>Tarkista<\/strong>:<br>&#8211; Vaihto Shellyn kiinte\u00e4\u00e4n IP-osoitteeseen Trydan-laturissa.<br>&#8211; Molempien laitteiden oikea liitt\u00e4minen asiakkaan samaan WiFi-verkkoon (ei laturiin).<br><br><strong>008<\/strong> On valittu WiFi-teknologialla varustettu mittari, eik\u00e4 Trydan koskaan yhdistynyt m\u00e4\u00e4ritettyyn WiFi-verkkoon.<br><strong>Tarkista<\/strong>:<br>&#8211; Molempien laitteiden oikea liitt\u00e4minen asiakkaan samaan WiFi-verkkoon riitt\u00e4v\u00e4ll\u00e4 signaalilla (ei laturiin).<br><br><strong>009 <\/strong>Saadaan aikakatkaisu pyynt\u00f6\u00f6n mittarilta.<br><strong>Tarkista<\/strong>:<br>&#8211; RJ-45-liittimen oikea puristus molemmissa p\u00e4iss\u00e4.<br>&#8211; Invertterin oikea konfigurointi suhteessa kommunikaatioparametreihin Trydanin kanssa.<br>&#8211; WiFi-invertterin tai mittarin tapauksessa molempien laitteiden oikea liitt\u00e4minen asiakkaan samaan WiFi-verkkoon riitt\u00e4v\u00e4ll\u00e4 signaalilla (ei laturiin).<br>&#8211; Invertterin IP-osoite ja sen oikea konfigurointi Trydanin dynaamisessa tehohallinnassa.<br>&#8211; Solax-invertteri: Oikea versio Pocket WiFi V2.033.20 (ladattava linkki sis\u00e4ltyy k\u00e4ytt\u00f6oppaaseen).<br><br><strong>010<\/strong> Saadaan tieto, ett\u00e4 klipsi ei ole kytketty kanavassa, joka on tarpeen<br>(Mono + FV klipsi 1 tai 4, Kolmivaiheiset klipsit 1, 2 tai 3)<br><strong>Tarkista<\/strong>:<br>&#8211; Klipsien oikea sijoittaminen vaiheisiin, jotka on merkitty oikeassa asennuskaaviossa kussakin tapauksessa.<\/p><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-00168f44\">\n<div class=\"wp-block-uagb-container uagb-block-c837e147\">\n<div class=\"wp-block-uagb-image aligncenter uagb-block-ded0ddba wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-center\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png ,https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png 780w, https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png\" alt=\"\" class=\"uag-image-125013\" width=\"50\" height=\"50\" title=\"\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-421a53a1\"><div class=\"wp-block-uagb-advanced-heading uagb-block-ab21f8f7\"><p class=\"uagb-heading-text\"><strong>T\u00c4RKE\u00c4 HUOMAUTUS:<\/strong> Jos <strong>virhekoodi on suurempi kuin 011<\/strong>, kyseess\u00e4 ovat <strong>MODBUS RTU tai TCP -protokollan mukaiset virheet. Vain erikoishenkil\u00f6st\u00f6lle.<\/strong> Voit luoda pyynn\u00f6n Teknisen Tukikeskuksen kautta, ja otamme sinuun yhteytt\u00e4 mahdollisimman pian.<\/p><\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-a889f73f\">\n<div class=\"wp-block-uagb-container uagb-block-3ced5973\"><p><strong>021 <\/strong> LLEGAL_FUNCTION<br><strong>022<\/strong> ILLEGAL_DATA_ADDRESS<br><strong>023<\/strong> ILLEGAL_DATA_VALUE<br><strong>024<\/strong> SERVER_DEVICE_FAILURE<br><strong>025<\/strong> ACKNOWLEDGE<br><strong>026<\/strong> SERVER_DEVICE_BUSY<br><strong>027<\/strong> NEGATIVE_ACKNOWLEDGE<br><strong>028<\/strong> MEMORY_PARITY_ERROR<br><strong>030<\/strong> GATEWAY_PATH_UNAVAIL<br><strong>031<\/strong> GATEWAY_TARGET_NO_RESP<br><strong>032<\/strong> SERVER_RTU_INACTIVE<br><strong>244<\/strong> TIMEOUT<br><strong>245<\/strong> INVALID_SERVER<br><strong>246<\/strong> CRC_ERROR<br><strong>247<\/strong> FC_MISMATCH<br><strong>248<\/strong> SERVER_ID_MISMATCH<br><strong>249<\/strong> PACKET_LENGTH_ERROR<\/p><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-70caf82a\"><p><strong>250<\/strong> PARAMETER_COUNT_ERROR<br><strong>251<\/strong> PARAMETER_LIMIT_ERROR<br><strong>252<\/strong> REQUEST_QUEUE_FULL<br><strong>253<\/strong> ILLEGAL_IP_OR_PORT<br><strong>254<\/strong> IP_CONNECTION_FAILED<br><strong>255<\/strong> TCP_HEAD_MISMATCH<br><strong>256<\/strong> EMPTY_MESSAGE<br><strong>275 <\/strong> UNDEFINED_ERROR<\/p><\/div>\n<\/div>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-c6f38013 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><div class=\"wp-block-uagb-advanced-heading uagb-block-6963d70c\"><h2 class=\"uagb-heading-text\"><strong>Tarvitsetko teknist\u00e4 tukea?<\/strong><\/h2><\/div>\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-408243eb\"><p class=\"uagb-heading-text\">Ratkaise ongelmasi heti IA-chatimme kautta. Jos ongelma ei ratkea, luo pyynt\u00f6 Tekniseen Tukikeskukseen, ja otamme sinuun yhteytt\u00e4 mahdollisimman pian tarjotaksemme parhaan ratkaisun.<\/p><\/div>\n\n<div class=\"wp-block-uagb-info-box uagb-block-12e3cf1c uagb-infobox__content-wrap  uagb-infobox-icon-left uagb-infobox-left uagb-infobox-image-valign-top wp-block-uagb-info-box--has-margin ai-chatbot-button\"><div class=\"uagb-infobox-margin-wrapper\"><div class=\"uagb-ifb-image-content\"><img decoding=\"async\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2026\/01\/support-ai-chatbot.png\" alt=\"\" width=\"20\" height=\"19\" loading=\"lazy\"\/><\/div><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><\/div><div class=\"uagb-ifb-button-wrapper wp-block-button\"><a href=\"https:\/\/v2charge.com\/v2c-support-web\/\" class=\"uagb-infobox-cta-link wp-block-button__link\" target=\"_blank\" rel=\"noopener noreferrer\" onclick=\"return true;\"><span class=\"uagb-inline-editing\">Kysy AI-chatiltamme<\/span><\/a><\/div><\/div><\/div><\/div>\n\n\n<div class=\"wp-block-uagb-buttons uagb-buttons__outer-wrap uagb-btn__default-btn uagb-btn-tablet__default-btn uagb-btn-mobile__default-btn uagb-block-ba1e67d1\"><div class=\"uagb-buttons__wrap uagb-buttons-layout-wrap \"><div class=\"wp-block-uagb-buttons-child uagb-buttons__outer-wrap uagb-block-23cfb623 wp-block-button\"><div class=\"uagb-button__wrapper\"><a class=\"uagb-buttons-repeater wp-block-button__link\" aria-label=\"\" href=\"https:\/\/v2charge.atlassian.net\/servicedesk\/customer\/portal\/3\" rel=\"follow noopener\" target=\"_blank\" role=\"button\"><div class=\"uagb-button__link\">Ota yhteytt\u00e4 tekniseen tukeen<\/div><\/a><\/div><\/div><\/div><\/div>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Yhteysvirhekoodit ja niiden ratkaisut Jos Trydan- tai Trydan Pro-laturin dynaamisen teho-ohjauksen aktivoinnissa ilmenee virhe, laturin n\u00e4yt\u00f6lle ilmestyy virhekoodi. Alla olevat ratkaisut virheisiin koskevat versiota 1.6.18 tai uudempi. Jos sinulla on vanhempi versio, p\u00e4ivit\u00e4 Trydan-laturi ja tarkista seuraava lista uudelleen. T\u00c4RKE\u00c4 HUOMAUTUS: n\u00e4m\u00e4 virheet johtuvat viestint\u00e4ongelmasta Trydanin ja invertterin tai mittarin v\u00e4lill\u00e4 ja rajoittavat ajoneuvosi latausta &#8230; <a title=\"Yhteysvirhekoodit ja niiden ratkaisut\" class=\"read-more\" href=\"https:\/\/v2charge.com\/fi\/tukialue\/tehonhallinta\/dynaaminen-tehohallinta\/yhteysvirhekoodit-ja-niiden-ratkaisut\/\" aria-label=\"Lue lis\u00e4\u00e4 aiheesta Yhteysvirhekoodit ja niiden ratkaisut\">Lue lis\u00e4\u00e4<\/a><\/p>\n","protected":false},"author":400,"featured_media":170346,"parent":311450,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_eb_attr":"","content-type":"","_uag_custom_page_level_css":"","footnotes":""},"class_list":["post-311495","page","type-page","status-publish","has-post-thumbnail"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.3.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Yhteysvirhekoodit ja niiden ratkaisut - Trydan<\/title>\n<meta name=\"description\" content=\"N\u00e4kyyk\u00f6 Trydanin n\u00e4yt\u00f6ss\u00e4 yhteysvirhe? Tutustu virheen merkitykseen ja sen ratkaisuun | Tuki-alue\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/v2charge.com\/fi\/tukialue\/tehonhallinta\/dynaaminen-tehohallinta\/yhteysvirhekoodit-ja-niiden-ratkaisut\/\" \/>\n<meta property=\"og:locale\" content=\"fi_FI\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Yhteysvirhekoodit ja niiden ratkaisut - Trydan\" \/>\n<meta property=\"og:description\" content=\"N\u00e4kyyk\u00f6 Trydanin n\u00e4yt\u00f6ss\u00e4 yhteysvirhe? Tutustu virheen merkitykseen ja sen ratkaisuun | Tuki-alue\" \/>\n<meta property=\"og:url\" content=\"https:\/\/v2charge.com\/fi\/tukialue\/tehonhallinta\/dynaaminen-tehohallinta\/yhteysvirhekoodit-ja-niiden-ratkaisut\/\" \/>\n<meta property=\"og:site_name\" content=\"V2C\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/V2C.Charge\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-13T14:45:07+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"675\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@V2C_Charge\" \/>\n<meta name=\"twitter:label1\" content=\"Arvioitu lukuaika\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 minuuttia\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/v2charge.com\/fi\/tukialue\/tehonhallinta\/dynaaminen-tehohallinta\/yhteysvirhekoodit-ja-niiden-ratkaisut\/\",\"url\":\"https:\/\/v2charge.com\/fi\/tukialue\/tehonhallinta\/dynaaminen-tehohallinta\/yhteysvirhekoodit-ja-niiden-ratkaisut\/\",\"name\":\"Yhteysvirhekoodit ja niiden ratkaisut - Trydan\",\"isPartOf\":{\"@id\":\"https:\/\/v2charge.com\/fi\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/v2charge.com\/fi\/tukialue\/tehonhallinta\/dynaaminen-tehohallinta\/yhteysvirhekoodit-ja-niiden-ratkaisut\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/v2charge.com\/fi\/tukialue\/tehonhallinta\/dynaaminen-tehohallinta\/yhteysvirhekoodit-ja-niiden-ratkaisut\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg\",\"datePublished\":\"2024-10-04T13:39:28+00:00\",\"dateModified\":\"2026-01-13T14:45:07+00:00\",\"description\":\"N\u00e4kyyk\u00f6 Trydanin n\u00e4yt\u00f6ss\u00e4 yhteysvirhe? Tutustu virheen merkitykseen ja sen ratkaisuun | Tuki-alue\",\"breadcrumb\":{\"@id\":\"https:\/\/v2charge.com\/fi\/tukialue\/tehonhallinta\/dynaaminen-tehohallinta\/yhteysvirhekoodit-ja-niiden-ratkaisut\/#breadcrumb\"},\"inLanguage\":\"fi\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/v2charge.com\/fi\/tukialue\/tehonhallinta\/dynaaminen-tehohallinta\/yhteysvirhekoodit-ja-niiden-ratkaisut\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fi\",\"@id\":\"https:\/\/v2charge.com\/fi\/tukialue\/tehonhallinta\/dynaaminen-tehohallinta\/yhteysvirhekoodit-ja-niiden-ratkaisut\/#primaryimage\",\"url\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg\",\"contentUrl\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg\",\"width\":1200,\"height\":675,\"caption\":\"V2C Electric Chargers\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/v2charge.com\/fi\/tukialue\/tehonhallinta\/dynaaminen-tehohallinta\/yhteysvirhekoodit-ja-niiden-ratkaisut\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"V2C\",\"item\":\"https:\/\/v2charge.com\/fi\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Din\u00e1mico\",\"item\":\"https:\/\/v2charge.com\/fi\/dynaaminen-tehohallinta\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Yhteysvirhekoodit ja niiden ratkaisut\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/v2charge.com\/fi\/#website\",\"url\":\"https:\/\/v2charge.com\/fi\/\",\"name\":\"V2C\",\"description\":\"#CargandoElMa\u00f1ana\",\"publisher\":{\"@id\":\"https:\/\/v2charge.com\/fi\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/v2charge.com\/fi\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fi\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/v2charge.com\/fi\/#organization\",\"name\":\"V2C\",\"url\":\"https:\/\/v2charge.com\/fi\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fi\",\"@id\":\"https:\/\/v2charge.com\/fi\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png\",\"contentUrl\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png\",\"width\":984,\"height\":431,\"caption\":\"V2C\"},\"image\":{\"@id\":\"https:\/\/v2charge.com\/fi\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/V2C.Charge\",\"https:\/\/x.com\/V2C_Charge\",\"https:\/\/www.instagram.com\/v2c.charge\/\",\"https:\/\/www.youtube.com\/@V2C\",\"https:\/\/www.linkedin.com\/company\/v2c-chargers\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Yhteysvirhekoodit ja niiden ratkaisut - Trydan","description":"N\u00e4kyyk\u00f6 Trydanin n\u00e4yt\u00f6ss\u00e4 yhteysvirhe? Tutustu virheen merkitykseen ja sen ratkaisuun | Tuki-alue","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/v2charge.com\/fi\/tukialue\/tehonhallinta\/dynaaminen-tehohallinta\/yhteysvirhekoodit-ja-niiden-ratkaisut\/","og_locale":"fi_FI","og_type":"article","og_title":"Yhteysvirhekoodit ja niiden ratkaisut - Trydan","og_description":"N\u00e4kyyk\u00f6 Trydanin n\u00e4yt\u00f6ss\u00e4 yhteysvirhe? Tutustu virheen merkitykseen ja sen ratkaisuun | Tuki-alue","og_url":"https:\/\/v2charge.com\/fi\/tukialue\/tehonhallinta\/dynaaminen-tehohallinta\/yhteysvirhekoodit-ja-niiden-ratkaisut\/","og_site_name":"V2C","article_publisher":"https:\/\/www.facebook.com\/V2C.Charge","article_modified_time":"2026-01-13T14:45:07+00:00","og_image":[{"width":1200,"height":675,"url":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@V2C_Charge","twitter_misc":{"Arvioitu lukuaika":"6 minuuttia"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/v2charge.com\/fi\/tukialue\/tehonhallinta\/dynaaminen-tehohallinta\/yhteysvirhekoodit-ja-niiden-ratkaisut\/","url":"https:\/\/v2charge.com\/fi\/tukialue\/tehonhallinta\/dynaaminen-tehohallinta\/yhteysvirhekoodit-ja-niiden-ratkaisut\/","name":"Yhteysvirhekoodit ja niiden ratkaisut - Trydan","isPartOf":{"@id":"https:\/\/v2charge.com\/fi\/#website"},"primaryImageOfPage":{"@id":"https:\/\/v2charge.com\/fi\/tukialue\/tehonhallinta\/dynaaminen-tehohallinta\/yhteysvirhekoodit-ja-niiden-ratkaisut\/#primaryimage"},"image":{"@id":"https:\/\/v2charge.com\/fi\/tukialue\/tehonhallinta\/dynaaminen-tehohallinta\/yhteysvirhekoodit-ja-niiden-ratkaisut\/#primaryimage"},"thumbnailUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","datePublished":"2024-10-04T13:39:28+00:00","dateModified":"2026-01-13T14:45:07+00:00","description":"N\u00e4kyyk\u00f6 Trydanin n\u00e4yt\u00f6ss\u00e4 yhteysvirhe? Tutustu virheen merkitykseen ja sen ratkaisuun | Tuki-alue","breadcrumb":{"@id":"https:\/\/v2charge.com\/fi\/tukialue\/tehonhallinta\/dynaaminen-tehohallinta\/yhteysvirhekoodit-ja-niiden-ratkaisut\/#breadcrumb"},"inLanguage":"fi","potentialAction":[{"@type":"ReadAction","target":["https:\/\/v2charge.com\/fi\/tukialue\/tehonhallinta\/dynaaminen-tehohallinta\/yhteysvirhekoodit-ja-niiden-ratkaisut\/"]}]},{"@type":"ImageObject","inLanguage":"fi","@id":"https:\/\/v2charge.com\/fi\/tukialue\/tehonhallinta\/dynaaminen-tehohallinta\/yhteysvirhekoodit-ja-niiden-ratkaisut\/#primaryimage","url":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","contentUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","width":1200,"height":675,"caption":"V2C Electric Chargers"},{"@type":"BreadcrumbList","@id":"https:\/\/v2charge.com\/fi\/tukialue\/tehonhallinta\/dynaaminen-tehohallinta\/yhteysvirhekoodit-ja-niiden-ratkaisut\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"V2C","item":"https:\/\/v2charge.com\/fi\/"},{"@type":"ListItem","position":2,"name":"Din\u00e1mico","item":"https:\/\/v2charge.com\/fi\/dynaaminen-tehohallinta\/"},{"@type":"ListItem","position":3,"name":"Yhteysvirhekoodit ja niiden ratkaisut"}]},{"@type":"WebSite","@id":"https:\/\/v2charge.com\/fi\/#website","url":"https:\/\/v2charge.com\/fi\/","name":"V2C","description":"#CargandoElMa\u00f1ana","publisher":{"@id":"https:\/\/v2charge.com\/fi\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/v2charge.com\/fi\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fi"},{"@type":"Organization","@id":"https:\/\/v2charge.com\/fi\/#organization","name":"V2C","url":"https:\/\/v2charge.com\/fi\/","logo":{"@type":"ImageObject","inLanguage":"fi","@id":"https:\/\/v2charge.com\/fi\/#\/schema\/logo\/image\/","url":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png","contentUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png","width":984,"height":431,"caption":"V2C"},"image":{"@id":"https:\/\/v2charge.com\/fi\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/V2C.Charge","https:\/\/x.com\/V2C_Charge","https:\/\/www.instagram.com\/v2c.charge\/","https:\/\/www.youtube.com\/@V2C","https:\/\/www.linkedin.com\/company\/v2c-chargers\/"]}]}},"uagb_featured_image_src":{"full":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"thumbnail":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-150x150.jpg",150,150,true],"medium":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-300x169.jpg",300,169,true],"medium_large":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-768x432.jpg",768,432,true],"large":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-1024x576.jpg",1024,576,true],"gs-tiny":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",50,28,false],"xl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxxxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxxxxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"1536x1536":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"2048x2048":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false]},"uagb_author_info":{"display_name":"V2C","author_link":"https:\/\/v2charge.com\/fi\/author\/marketing\/"},"uagb_comment_info":0,"uagb_excerpt":"Yhteysvirhekoodit ja niiden ratkaisut Jos Trydan- tai Trydan Pro-laturin dynaamisen teho-ohjauksen aktivoinnissa ilmenee virhe, laturin n\u00e4yt\u00f6lle ilmestyy virhekoodi. Alla olevat ratkaisut virheisiin koskevat versiota 1.6.18 tai uudempi. Jos sinulla on vanhempi versio, p\u00e4ivit\u00e4 Trydan-laturi ja tarkista seuraava lista uudelleen. T\u00c4RKE\u00c4 HUOMAUTUS: n\u00e4m\u00e4 virheet johtuvat viestint\u00e4ongelmasta Trydanin ja invertterin tai mittarin v\u00e4lill\u00e4 ja rajoittavat ajoneuvosi latausta&hellip;","_links":{"self":[{"href":"https:\/\/v2charge.com\/fi\/wp-json\/wp\/v2\/pages\/311495","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/v2charge.com\/fi\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/v2charge.com\/fi\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/v2charge.com\/fi\/wp-json\/wp\/v2\/users\/400"}],"replies":[{"embeddable":true,"href":"https:\/\/v2charge.com\/fi\/wp-json\/wp\/v2\/comments?post=311495"}],"version-history":[{"count":0,"href":"https:\/\/v2charge.com\/fi\/wp-json\/wp\/v2\/pages\/311495\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/v2charge.com\/fi\/wp-json\/wp\/v2\/pages\/311450"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/v2charge.com\/fi\/wp-json\/wp\/v2\/media\/170346"}],"wp:attachment":[{"href":"https:\/\/v2charge.com\/fi\/wp-json\/wp\/v2\/media?parent=311495"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}