{"id":186374,"date":"2024-10-31T17:10:42","date_gmt":"2024-10-31T15:10:42","guid":{"rendered":"https:\/\/v2charge.com\/?page_id=186374"},"modified":"2026-01-13T16:47:00","modified_gmt":"2026-01-13T14:47:00","slug":"solution-erreurs","status":"publish","type":"page","link":"https:\/\/v2charge.com\/fr\/support\/controle-puissance\/dynamique\/solution-erreurs\/","title":{"rendered":"Codes d&rsquo;erreurs de connexion et solutions"},"content":{"rendered":"\n<div class=\"wp-block-uagb-container uagb-block-9d828d1c alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><div class=\"yoast-breadcrumbs\"><span><span><a href=\"https:\/\/v2charge.com\/fr\/\">V2C<\/a><\/span> \u00bb <span><a href=\"https:\/\/v2charge.com\/fr\/support\/\">Support Area<\/a><\/span> \u00bb <span><a href=\"https:\/\/v2charge.com\/fr\/support\/controle-puissance\/\">Contr\u00f4le de puissance<\/a><\/span> \u00bb <span><a href=\"https:\/\/v2charge.com\/fr\/support\/controle-puissance\/dynamique\/\">Dynamique<\/a><\/span> \u00bb <span class=\"breadcrumb_last\" aria-current=\"page\">Codes d&#8217;erreurs de connexion et solutions<\/span><\/span><\/div>\n\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-be8360a4\"><h1 class=\"uagb-heading-text\">Codes d&rsquo;erreurs de connexion et solutions<\/h1><\/div>\n\n\n\n<p>En cas d&rsquo;erreur lors de l&rsquo;activation du contr\u00f4le dynamique de puissance sur le chargeur Trydan ou Trydan Pro, un <strong>code d&rsquo;erreur correspondant<\/strong> appara\u00eetra sur l&rsquo;\u00e9cran du chargeur.<br><br>Les solutions aux erreurs mentionn\u00e9es ci-dessous s&rsquo;appliquent \u00e0 la version 1.6.18 ou ult\u00e9rieure. Si vous utilisez une version ant\u00e9rieure, il est recommand\u00e9 de <strong><a href=\"https:\/\/v2charge.com\/fr\/support\/trydan\/mise-jour-derniere-version\/\">mettre \u00e0 jour le chargeur Trydan<\/a><\/strong> et de consulter la liste suivante.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-f83ba0fb alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-9d537ef2\">\n<div class=\"wp-block-uagb-container uagb-block-1021f2c1\">\n<div class=\"wp-block-uagb-image aligncenter uagb-block-f5b78000 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-center\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png ,https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png 780w, https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png\" alt=\"\" class=\"uag-image-125013\" width=\"50\" height=\"50\" title=\"\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-a8351972\">\n<div class=\"wp-block-uagb-advanced-heading uagb-block-fdcb9def\"><p class=\"uagb-heading-text\"><strong>NOTE IMPORTANTE<\/strong> <strong>:<\/strong> Ces erreurs sont li\u00e9es \u00e0 un probl\u00e8me de communication entre Trydan et l&rsquo;onduleur ou le compteur, ce qui limite la charge de votre v\u00e9hicule au niveau minimal. Certaines erreurs peuvent survenir lors d&rsquo;une int\u00e9gration directe avec l&rsquo;onduleur, via la communication Modbus ou RS485.<br><strong>Il est essentiel de consulter la solution associ\u00e9e \u00e0 l&rsquo;erreur affich\u00e9e \u00e0 l&rsquo;\u00e9cran<\/strong>. Si l&rsquo;erreur persiste, veuillez contacter notre Service d&rsquo;Assistance Technique et d\u00e9sactiver le contr\u00f4le dynamique de charge afin de pouvoir charger votre v\u00e9hicule \u00e0 l&rsquo;intensit\u00e9 fixe d\u00e9finie.<\/p><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-separator uagb-block-b0f92113\"><div class=\"wp-block-uagb-separator__inner\" style=\"--my-background-image:\"><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-4d0c1e2a\">\n<div class=\"wp-block-uagb-container uagb-block-195968cb\">\n<table style=\"border:none;\">\n    <tr style=\"border:none;\">\n        <th style=\"border:none;\">ERREUR<\/th>\n        <th style=\"border:none;\"><u>00<\/u><\/th>\n        <th style=\"border:none;\"><u>000<\/u><\/th>\n    <\/tr>\n    <tr style=\"border:none;\">\n        <td style=\"border:none;\"><\/td>\n        <td style=\"border:none;\"><center>A<\/center><\/td>\n        <td style=\"border:none;\"><center>B<\/center><\/td>\n    <\/tr>\n<\/table>\n<\/div>\n<\/div>\n\n\n\n<p>Les <strong>deux premiers chiffres<\/strong> indiquent le compteur ou l&rsquo;onduleur utilis\u00e9. Il est important de s\u00e9lectionner le bon appareil lors de la configuration du contr\u00f4le dynamique de puissance et de v\u00e9rifier cette s\u00e9lection en cas d&rsquo;erreur.<\/p>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-1f2b6973\">\n<div class=\"wp-block-uagb-container uagb-block-8b607314\">\n<p><strong>Erreurs &#8211; A<\/strong><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-307016ef\">\n<p><strong>00<\/strong> Compteur Shelly<br><strong>01<\/strong>  V2C ControlBox<br><strong>02<\/strong>  Compteur V2C 1.0<br><strong>03<\/strong>  Connexion \u00e0 l&rsquo;onduleur Huawei<br><strong>04<\/strong>  Connexion \u00e0 l&rsquo;onduleur Solax<br><strong>05<\/strong>  Connexion \u00e0 l&rsquo;onduleur Kostal<br><strong>06<\/strong>  Connexion \u00e0 l&rsquo;onduleur Fronius<br><strong>07<\/strong>  Connexion \u00e0 l&rsquo;onduleur Ingeteam<br><strong>08  <\/strong>Connexion \u00e0 l&rsquo;onduleur Wibeee<br><strong>09<\/strong>  Connexion \u00e0 l&rsquo;onduleur Victron<br><strong>10<\/strong>  Connexion \u00e0 l&rsquo;onduleur SolarEdge<br><strong>11<\/strong>  Utilisation du protocole MQTT<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-cab9608d\">\n<p><strong>12<\/strong> Connexion \u00e0 l&rsquo;onduleur Goodwe<br><strong>13<\/strong> Connexion \u00e0 l&rsquo;onduleur SAJ \/ GreenHeiss<br><strong>14<\/strong> Connexion \u00e0 l&rsquo;onduleur Solis<br><strong>15<\/strong> Connexion au compteur Chint DDSU666<br><strong>16<\/strong> Connexion au compteur Eastron<br><strong>17<\/strong> Connexion au compteur Phoneix Contact<br><strong>18<\/strong> Connexion au compteur Carlo Gavazzi<br><strong>19<\/strong> Connexion au compteur SMA<br><strong>20<\/strong> Connexion \u00e0 l&rsquo;onduleur Deye \/ Turbo Energy<br><strong>21<\/strong> Connexion \u00e0 l&rsquo;onduleur ENPHASE<br><strong>22<\/strong> Connexion au compteur WiFi P1 Meter<br><strong>23<\/strong> Connexion via Modbus<br><strong>25<\/strong> Connexion au compteur Shelly Pro<br><strong>26<\/strong> Connexion \u00e0 l\u2019onduleur Growatt<br><strong>27<\/strong> Connexion \u00e0 l\u2019onduleur Sungrow<br><strong>28<\/strong> Connexion au compteur LINKY LORA<br><strong>94<\/strong> Mesure Car hors plage<br><strong>95<\/strong> Mesure Grid hors plage<br><strong>96<\/strong> Mesure House hors plage<br><strong>97<\/strong> Mesure Battery hors plage<br><strong>98<\/strong> Mesure PV hors plage<br><strong>99<\/strong> Connexion entre deux chargeurs Trydan en mode \u00e9quilibrage de charge<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-separator uagb-block-2e0a9e6d\"><div class=\"wp-block-uagb-separator__inner\" style=\"--my-background-image:\"><\/div><\/div>\n\n\n\n<p><strong>Erreurs &#8211; B<\/strong><\/p>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-b06f9306 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-f93d3349\">\n<p><strong>000 <\/strong>Mesures hors plage.<br><strong>V\u00e9rifier :<br><\/strong>\u2013 Si le chargeur dispose d\u2019un compteur interne. V\u00e9rifier la marque, s\u2019il est monophas\u00e9 ou triphas\u00e9, et le configurer sur le chargeur \u00e0 l\u2019aide du panneau de commande, ou contacter le support pour le configurer \u00e0 distance si le chargeur est en ligne.<br>\u2013 La connexion physique correcte du compteur \u00e0 la carte de puissance.<br><br><strong><strong>001<\/strong> <\/strong>Pour les \u00e9quipements Goodwe avec protocole UDP<strong><strong><br>V\u00e9rifier:<\/strong><\/strong><br>&#8211; L&rsquo;onduleur et le chargeur sont tous deux connect\u00e9s \u00e0 Internet.<br> &#8211; L&rsquo;IP de l&rsquo;onduleur est incorrectement assign\u00e9e dans l&rsquo;e-Charger.<br><br><strong>002<\/strong> Pour les compteurs V2C 1.0 et 2.0 : les trames arrivent corrompues.<strong><br>V\u00e9rifier<\/strong> :<br>&#8211; Sertissage correct du connecteur RJ-45 aux deux extr\u00e9mit\u00e9s.<br>&#8211; Configuration correcte du contr\u00f4le dynamique avec le compteur s\u00e9lectionn\u00e9 correspondant \u00e0 l&rsquo;installation.<br><br><strong>003<\/strong> Bruit possible dans le signal du V2C ControlBox.<br><strong><strong><strong>V\u00e9rifier:<\/strong><\/strong><br><\/strong>&#8211; Sertissage correct du connecteur RJ-45 aux deux extr\u00e9mit\u00e9s.<br>&#8211; Configuration correcte du contr\u00f4le dynamique avec le compteur s\u00e9lectionn\u00e9 correspondant \u00e0 l&rsquo;installation.<br><br><strong>004<\/strong> Trydan est d\u00e9connect\u00e9 du WiFi et essaie de se reconnecter. Le compteur WiFi utilise cette technologie WiFi pour se connecter.<br><strong><strong><strong>V\u00e9rifier :<\/strong><\/strong><\/strong><br>&#8211; Connexion correcte des deux appareils au m\u00eame WiFi (pas au chargeur).<br>&#8211; La puissance du signal doit \u00eatre optimale, ou bien la connexion WiFi \u00e0 laquelle les deux appareils sont connect\u00e9s doit \u00eatre am\u00e9lior\u00e9e \u00e0 l&rsquo;aide d&rsquo;un r\u00e9p\u00e9teur.<br><br><strong>005<\/strong> Le V2C ControlBox connect\u00e9 via RJ-45 ne r\u00e9pond pas.<br><strong><strong><strong>V\u00e9rifier :<\/strong><\/strong><\/strong><br>&#8211; Sertissage correct du connecteur RJ-45 aux deux extr\u00e9mit\u00e9s.<br><br><strong>006<\/strong> Une requ\u00eate HTTP est effectu\u00e9e et la connexion \u00e9choue (Shelly, Solax, Kostal Piko, Enphase, P1 Meter, SAJ [Solar Data], Wibeee). \u00c9chec de la connexion au serveur Modbus TCP (Huawei, Kostal Plenticore, Fronius, Ingeteam, SMA Sunny, SolarEdge, Victron).<br><strong><strong><strong>V\u00e9rifier :<\/strong><\/strong><\/strong><br>&#8211; Connexion correcte des deux appareils au m\u00eame WiFi (pas au chargeur).<br>&#8211; L&rsquo;IP de l&rsquo;onduleur est mal assign\u00e9 dans l&rsquo;e-Charger.<br>&#8211; La puissance du signal doit \u00eatre optimale, ou bien la connexion WiFi \u00e0 laquelle les deux appareils sont connect\u00e9s doit \u00eatre am\u00e9lior\u00e9e \u00e0 l&rsquo;aide d&rsquo;un r\u00e9p\u00e9teur.<br>&#8211; Configuration correcte de l&rsquo;onduleur pour les param\u00e8tres de communication avec Trydan.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-91f1fcd1\">\n<p><strong>007<\/strong>  La recherche automatique de Shelly n&rsquo;a trouv\u00e9 aucun dispositif.<br><strong><strong><strong>V\u00e9rifier :<\/strong><\/strong><\/strong><br>&#8211; Passage \u00e0 l&rsquo;IP fixe du Shelly dans le chargeur Trydan.<br>&#8211; Connexion correcte des deux appareils au m\u00eame WiFi (pas au chargeur).<br><br><strong>008<\/strong>  Un compteur compatible WiFi a \u00e9t\u00e9 s\u00e9lectionn\u00e9 et Trydan ne s&rsquo;est jamais connect\u00e9 au r\u00e9seau WiFi configur\u00e9.<br><strong><strong><strong>V\u00e9rifier :<\/strong><\/strong><\/strong><br>&#8211; Connexion correcte des deux appareils au m\u00eame WiFi avec un signal suffisant (pas au chargeur).<br><br><strong>009  <\/strong>Un d\u00e9lai d&rsquo;attente de la demande au compteur est re\u00e7u.<br><strong><strong><strong>V\u00e9rifier :<\/strong><\/strong><\/strong><br>&#8211; Sertissage correct du connecteur RJ-45 aux deux extr\u00e9mit\u00e9s.<br>&#8211; Configuration correcte de l&rsquo;onduleur pour les param\u00e8tres de communication avec Trydan.<br>&#8211; Pour un onduleur ou un compteur WiFi, il est essentiel que les deux appareils soient correctement connect\u00e9s au m\u00eame r\u00e9seau WiFi avec un signal suffisant (et non au chargeur).<br>&#8211; L&rsquo;adresse IP de l&rsquo;onduleur, qui doit \u00eatre correctement configur\u00e9e dans le contr\u00f4le dynamique de puissance de Trydan.<br>&#8211; Solax Inverter : Version correcte de Pocket WiFi V2.033.20 (lien de t\u00e9l\u00e9chargement inclus dans le manuel).<br><br><strong>010<\/strong>  Des donn\u00e9es sont re\u00e7ues d&rsquo;une pince non connect\u00e9e sur un canal requis.<br>(Mono + pince PV 1 ou 4, pince triphas\u00e9e 1, 2 ou 3)<br><strong><strong><strong>V\u00e9rifier :<\/strong><\/strong><\/strong><br>&#8211; Placement correct des pinces dans les phases indiqu\u00e9es dans le sch\u00e9ma d&rsquo;installation dans chaque cas.<\/p>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-00168f44\">\n<div class=\"wp-block-uagb-container uagb-block-c837e147\">\n<div class=\"wp-block-uagb-image aligncenter uagb-block-ded0ddba wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-center\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png ,https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png 780w, https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png\" alt=\"\" class=\"uag-image-125013\" width=\"50\" height=\"50\" title=\"\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-421a53a1\">\n<div class=\"wp-block-uagb-advanced-heading uagb-block-ab21f8f7\"><p class=\"uagb-heading-text\"><strong><strong>NOTE IMPORTANTE :<\/strong> Si le code d&rsquo;erreur est sup\u00e9rieur \u00e0 011, il s\u2019agit d&rsquo;erreurs sp\u00e9cifiques<\/strong> <strong>au protocole MODBUS RTU ou TCP<\/strong>, <strong>destin\u00e9es \u00e0 \u00eatre trait\u00e9es par du personnel sp\u00e9cialis\u00e9.<\/strong> Dans ce cas, vous pouvez soumettre une demande \u00e0 notre Centre d&rsquo;Assistance Technique, et nous vous contacterons dans les plus brefs d\u00e9lais.<\/p><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-d7609742\">\n<div class=\"wp-block-uagb-container uagb-block-b603c5cf\">\n<p><strong>021 <\/strong> LLEGAL_FUNCTION<br><strong>022<\/strong> ILLEGAL_DATA_ADDRESS<br><strong>023<\/strong> ILLEGAL_DATA_VALUE<br><strong>024<\/strong> SERVER_DEVICE_FAILURE<br><strong>025<\/strong> ACKNOWLEDGE<br><strong>026<\/strong> SERVER_DEVICE_BUSY<br><strong>027<\/strong> NEGATIVE_ACKNOWLEDGE<br><strong>028<\/strong> MEMORY_PARITY_ERROR<br><strong>030<\/strong> GATEWAY_PATH_UNAVAIL<br><strong>031<\/strong> GATEWAY_TARGET_NO_RESP<br><strong>032<\/strong> SERVER_RTU_INACTIVE<br><strong>244<\/strong> TIMEOUT<br><strong>245<\/strong> INVALID_SERVER<br><strong>246<\/strong> CRC_ERROR<br><strong>247<\/strong> FC_MISMATCH<br><strong>248<\/strong> SERVER_ID_MISMATCH<br><strong>249<\/strong> PACKET_LENGTH_ERROR<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-6bb3d6bf\">\n<p><strong>250<\/strong>  PARAMETER_COUNT_ERROR<br><strong>251<\/strong>  PARAMETER_LIMIT_ERROR<br><strong>252<\/strong>  REQUEST_QUEUE_FULL<br><strong>253<\/strong>  ILLEGAL_IP_OR_PORT<br><strong>254<\/strong>  IP_CONNECTION_FAILED<br><strong>255<\/strong>  TCP_HEAD_MISMATCH<br><strong>256<\/strong>  EMPTY_MESSAGE<br><strong>275 <\/strong> UNDEFINED_ERROR<\/p>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:80px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-c6f38013 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-advanced-heading uagb-block-6963d70c\"><h2 class=\"uagb-heading-text\"><strong>Vous avez besoin d\u2019assistance technique ?<\/strong><\/h2><\/div>\n\n\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-408243eb\"><p class=\"uagb-heading-text\">R\u00e9solvez votre probl\u00e8me instantan\u00e9ment gr\u00e2ce \u00e0 notre <strong>chat avec IA<\/strong>. Si celui-ci ne peut pas le r\u00e9soudre, cr\u00e9ez une demande dans le <strong>Centre d\u2019assistance technique<\/strong> et nous vous contacterons dans les plus brefs d\u00e9lais afin de vous proposer la meilleure solution.<\/p><\/div>\n\n\n\n<div class=\"wp-block-uagb-info-box uagb-block-12e3cf1c uagb-infobox__content-wrap  uagb-infobox-icon-left uagb-infobox-left uagb-infobox-image-valign-top wp-block-uagb-info-box--has-margin ai-chatbot-button\"><div class=\"uagb-infobox-margin-wrapper\"><div class=\"uagb-ifb-image-content\"><img decoding=\"async\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2026\/01\/support-ai-chatbot.png\" alt=\"\" width=\"20\" height=\"19\" loading=\"lazy\"\/><\/div><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><\/div><div class=\"uagb-ifb-button-wrapper wp-block-button\"><a href=\"https:\/\/v2charge.com\/v2c-support-web\/\" class=\"uagb-infobox-cta-link wp-block-button__link\" target=\"_blank\" rel=\"noopener noreferrer\" onclick=\"return true;\"><span class=\"uagb-inline-editing\">Poser une question \u00e0 notre chat IA<\/span><\/a><\/div><\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-buttons uagb-buttons__outer-wrap uagb-btn__default-btn uagb-btn-tablet__default-btn uagb-btn-mobile__default-btn uagb-block-ba1e67d1\"><div class=\"uagb-buttons__wrap uagb-buttons-layout-wrap \">\n<div class=\"wp-block-uagb-buttons-child uagb-buttons__outer-wrap uagb-block-23cfb623 wp-block-button\"><div class=\"uagb-button__wrapper\"><a class=\"uagb-buttons-repeater wp-block-button__link\" aria-label=\"\" href=\"https:\/\/v2charge.atlassian.net\/servicedesk\/customer\/portal\/3\" rel=\"follow noopener\" target=\"_blank\" role=\"button\"><div class=\"uagb-button__link\">Contacter le support technique<\/div><\/a><\/div><\/div>\n<\/div><\/div>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Codes d&rsquo;erreurs de connexion et solutions En cas d&rsquo;erreur lors de l&rsquo;activation du contr\u00f4le dynamique de puissance sur le chargeur Trydan ou Trydan Pro, un code d&rsquo;erreur correspondant appara\u00eetra sur l&rsquo;\u00e9cran du chargeur. Les solutions aux erreurs mentionn\u00e9es ci-dessous s&rsquo;appliquent \u00e0 la version 1.6.18 ou ult\u00e9rieure. Si vous utilisez une version ant\u00e9rieure, il est recommand\u00e9 &#8230; <a title=\"Codes d&rsquo;erreurs de connexion et solutions\" class=\"read-more\" href=\"https:\/\/v2charge.com\/fr\/support\/controle-puissance\/dynamique\/solution-erreurs\/\" aria-label=\"Read more about Codes d&rsquo;erreurs de connexion et solutions\">Lire la suite<\/a><\/p>\n","protected":false},"author":400,"featured_media":170349,"parent":125463,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_eb_attr":"","content-type":"","_uag_custom_page_level_css":"","footnotes":""},"class_list":["post-186374","page","type-page","status-publish","has-post-thumbnail"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.3.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Codes d&#039;erreurs de connexion et solutions - Trydan<\/title>\n<meta name=\"description\" content=\"Un code d&#039;erreur de connexion appara\u00eet-il sur l\u2019afficheur de Trydan ? D\u00e9couvrez la signification de l&#039;erreur et sa solution | Espace d&#039;Assistance\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/v2charge.com\/fr\/support\/controle-puissance\/dynamique\/solution-erreurs\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Codes d&#039;erreurs de connexion et solutions - Trydan\" \/>\n<meta property=\"og:description\" content=\"Un code d&#039;erreur de connexion appara\u00eet-il sur l\u2019afficheur de Trydan ? D\u00e9couvrez la signification de l&#039;erreur et sa solution | Espace d&#039;Assistance\" \/>\n<meta property=\"og:url\" content=\"https:\/\/v2charge.com\/fr\/support\/controle-puissance\/dynamique\/solution-erreurs\/\" \/>\n<meta property=\"og:site_name\" content=\"V2C\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/V2C.Charge\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-13T14:47:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"675\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@V2C_Charge\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/v2charge.com\/fr\/support\/controle-puissance\/dynamique\/solution-erreurs\/\",\"url\":\"https:\/\/v2charge.com\/fr\/support\/controle-puissance\/dynamique\/solution-erreurs\/\",\"name\":\"Codes d'erreurs de connexion et solutions - Trydan\",\"isPartOf\":{\"@id\":\"https:\/\/v2charge.com\/fr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/v2charge.com\/fr\/support\/controle-puissance\/dynamique\/solution-erreurs\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/v2charge.com\/fr\/support\/controle-puissance\/dynamique\/solution-erreurs\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg\",\"datePublished\":\"2024-10-31T15:10:42+00:00\",\"dateModified\":\"2026-01-13T14:47:00+00:00\",\"description\":\"Un code d'erreur de connexion appara\u00eet-il sur l\u2019afficheur de Trydan ? D\u00e9couvrez la signification de l'erreur et sa solution | Espace d'Assistance\",\"breadcrumb\":{\"@id\":\"https:\/\/v2charge.com\/fr\/support\/controle-puissance\/dynamique\/solution-erreurs\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/v2charge.com\/fr\/support\/controle-puissance\/dynamique\/solution-erreurs\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/v2charge.com\/fr\/support\/controle-puissance\/dynamique\/solution-erreurs\/#primaryimage\",\"url\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg\",\"contentUrl\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg\",\"width\":1200,\"height\":675,\"caption\":\"V2C Electric Chargers\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/v2charge.com\/fr\/support\/controle-puissance\/dynamique\/solution-erreurs\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"V2C\",\"item\":\"https:\/\/v2charge.com\/fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Support Area\",\"item\":\"https:\/\/v2charge.com\/fr\/support\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Contr\u00f4le de puissance\",\"item\":\"https:\/\/v2charge.com\/fr\/support\/controle-puissance\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Dynamique\",\"item\":\"https:\/\/v2charge.com\/fr\/support\/controle-puissance\/dynamique\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"Codes d&#8217;erreurs de connexion et solutions\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/v2charge.com\/fr\/#website\",\"url\":\"https:\/\/v2charge.com\/fr\/\",\"name\":\"V2C\",\"description\":\"#CargandoElMa\u00f1ana\",\"publisher\":{\"@id\":\"https:\/\/v2charge.com\/fr\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/v2charge.com\/fr\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/v2charge.com\/fr\/#organization\",\"name\":\"V2C\",\"url\":\"https:\/\/v2charge.com\/fr\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/v2charge.com\/fr\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png\",\"contentUrl\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png\",\"width\":984,\"height\":431,\"caption\":\"V2C\"},\"image\":{\"@id\":\"https:\/\/v2charge.com\/fr\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/V2C.Charge\",\"https:\/\/x.com\/V2C_Charge\",\"https:\/\/www.instagram.com\/v2c.charge\/\",\"https:\/\/www.youtube.com\/@V2C\",\"https:\/\/www.linkedin.com\/company\/v2c-chargers\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Codes d'erreurs de connexion et solutions - Trydan","description":"Un code d'erreur de connexion appara\u00eet-il sur l\u2019afficheur de Trydan ? D\u00e9couvrez la signification de l'erreur et sa solution | Espace d'Assistance","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/v2charge.com\/fr\/support\/controle-puissance\/dynamique\/solution-erreurs\/","og_locale":"fr_FR","og_type":"article","og_title":"Codes d'erreurs de connexion et solutions - Trydan","og_description":"Un code d'erreur de connexion appara\u00eet-il sur l\u2019afficheur de Trydan ? D\u00e9couvrez la signification de l'erreur et sa solution | Espace d'Assistance","og_url":"https:\/\/v2charge.com\/fr\/support\/controle-puissance\/dynamique\/solution-erreurs\/","og_site_name":"V2C","article_publisher":"https:\/\/www.facebook.com\/V2C.Charge","article_modified_time":"2026-01-13T14:47:00+00:00","og_image":[{"width":1200,"height":675,"url":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@V2C_Charge","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/v2charge.com\/fr\/support\/controle-puissance\/dynamique\/solution-erreurs\/","url":"https:\/\/v2charge.com\/fr\/support\/controle-puissance\/dynamique\/solution-erreurs\/","name":"Codes d'erreurs de connexion et solutions - Trydan","isPartOf":{"@id":"https:\/\/v2charge.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/v2charge.com\/fr\/support\/controle-puissance\/dynamique\/solution-erreurs\/#primaryimage"},"image":{"@id":"https:\/\/v2charge.com\/fr\/support\/controle-puissance\/dynamique\/solution-erreurs\/#primaryimage"},"thumbnailUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","datePublished":"2024-10-31T15:10:42+00:00","dateModified":"2026-01-13T14:47:00+00:00","description":"Un code d'erreur de connexion appara\u00eet-il sur l\u2019afficheur de Trydan ? D\u00e9couvrez la signification de l'erreur et sa solution | Espace d'Assistance","breadcrumb":{"@id":"https:\/\/v2charge.com\/fr\/support\/controle-puissance\/dynamique\/solution-erreurs\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/v2charge.com\/fr\/support\/controle-puissance\/dynamique\/solution-erreurs\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/v2charge.com\/fr\/support\/controle-puissance\/dynamique\/solution-erreurs\/#primaryimage","url":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","contentUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","width":1200,"height":675,"caption":"V2C Electric Chargers"},{"@type":"BreadcrumbList","@id":"https:\/\/v2charge.com\/fr\/support\/controle-puissance\/dynamique\/solution-erreurs\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"V2C","item":"https:\/\/v2charge.com\/fr\/"},{"@type":"ListItem","position":2,"name":"Support Area","item":"https:\/\/v2charge.com\/fr\/support\/"},{"@type":"ListItem","position":3,"name":"Contr\u00f4le de puissance","item":"https:\/\/v2charge.com\/fr\/support\/controle-puissance\/"},{"@type":"ListItem","position":4,"name":"Dynamique","item":"https:\/\/v2charge.com\/fr\/support\/controle-puissance\/dynamique\/"},{"@type":"ListItem","position":5,"name":"Codes d&#8217;erreurs de connexion et solutions"}]},{"@type":"WebSite","@id":"https:\/\/v2charge.com\/fr\/#website","url":"https:\/\/v2charge.com\/fr\/","name":"V2C","description":"#CargandoElMa\u00f1ana","publisher":{"@id":"https:\/\/v2charge.com\/fr\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/v2charge.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/v2charge.com\/fr\/#organization","name":"V2C","url":"https:\/\/v2charge.com\/fr\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/v2charge.com\/fr\/#\/schema\/logo\/image\/","url":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png","contentUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png","width":984,"height":431,"caption":"V2C"},"image":{"@id":"https:\/\/v2charge.com\/fr\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/V2C.Charge","https:\/\/x.com\/V2C_Charge","https:\/\/www.instagram.com\/v2c.charge\/","https:\/\/www.youtube.com\/@V2C","https:\/\/www.linkedin.com\/company\/v2c-chargers\/"]}]}},"uagb_featured_image_src":{"full":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"thumbnail":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-150x150.jpg",150,150,true],"medium":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-300x169.jpg",300,169,true],"medium_large":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-768x432.jpg",768,432,true],"large":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-1024x576.jpg",1024,576,true],"gs-tiny":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",50,28,false],"xl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxxxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxxxxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"1536x1536":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"2048x2048":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false]},"uagb_author_info":{"display_name":"V2C","author_link":"https:\/\/v2charge.com\/fr\/author\/marketing\/"},"uagb_comment_info":0,"uagb_excerpt":"Codes d&rsquo;erreurs de connexion et solutions En cas d&rsquo;erreur lors de l&rsquo;activation du contr\u00f4le dynamique de puissance sur le chargeur Trydan ou Trydan Pro, un code d&rsquo;erreur correspondant appara\u00eetra sur l&rsquo;\u00e9cran du chargeur. Les solutions aux erreurs mentionn\u00e9es ci-dessous s&rsquo;appliquent \u00e0 la version 1.6.18 ou ult\u00e9rieure. Si vous utilisez une version ant\u00e9rieure, il est recommand\u00e9\u2026","_links":{"self":[{"href":"https:\/\/v2charge.com\/fr\/wp-json\/wp\/v2\/pages\/186374","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/v2charge.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/v2charge.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/v2charge.com\/fr\/wp-json\/wp\/v2\/users\/400"}],"replies":[{"embeddable":true,"href":"https:\/\/v2charge.com\/fr\/wp-json\/wp\/v2\/comments?post=186374"}],"version-history":[{"count":5,"href":"https:\/\/v2charge.com\/fr\/wp-json\/wp\/v2\/pages\/186374\/revisions"}],"predecessor-version":[{"id":295432,"href":"https:\/\/v2charge.com\/fr\/wp-json\/wp\/v2\/pages\/186374\/revisions\/295432"}],"up":[{"embeddable":true,"href":"https:\/\/v2charge.com\/fr\/wp-json\/wp\/v2\/pages\/125463"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/v2charge.com\/fr\/wp-json\/wp\/v2\/media\/170349"}],"wp:attachment":[{"href":"https:\/\/v2charge.com\/fr\/wp-json\/wp\/v2\/media?parent=186374"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}