{"id":241024,"date":"2025-08-01T12:58:14","date_gmt":"2025-08-01T10:58:14","guid":{"rendered":"https:\/\/v2charge.com\/support\/trydan\/medidor-mid\/"},"modified":"2026-10-20T14:09:58","modified_gmt":"2026-10-20T12:09:58","slug":"mid-meter","status":"publish","type":"page","link":"https:\/\/v2charge.com\/fr\/support\/trydan\/mid-meter\/","title":{"rendered":"Comment connecter et configurer le compteur MID sur Trydan\/Trydan Pro"},"content":{"rendered":"\n<div class=\"wp-block-uagb-container uagb-block-4e29f302 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><div class=\"yoast-breadcrumbs\"><span><span><a href=\"https:\/\/v2charge.com\/fr\/\">V2C<\/a><\/span> \u00bb <span><a href=\"https:\/\/v2charge.com\/fr\/support\/\">Support Area<\/a><\/span> \u00bb <span><a href=\"https:\/\/v2charge.com\/fr\/support\/trydan\/\">Support Trydan<\/a><\/span> \u00bb <span class=\"breadcrumb_last\" aria-current=\"page\">Comment connecter et configurer le compteur MID sur Trydan\/Trydan Pro<\/span><\/span><\/div>\n\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-eb8d37cd\"><h1 class=\"uagb-heading-text\">Comment connecter et configurer le compteur MID sur Trydan et Trydan Pro ?<\/h1><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Le <strong>compteur MID<\/strong> est un <strong>dispositif de mesure<\/strong> \u00e9lectrique conforme aux exigences de la directive europ\u00e9enne 2014\/32\/UE, \u00e9galement appel\u00e9e directive MID (<em>Measuring Instruments Directive<\/em>).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Il permet de <strong>mesurer avec pr\u00e9cision l\u2019\u00e9nergie consomm\u00e9e<\/strong> lors de la recharge des v\u00e9hicules \u00e9lectriques, notamment lorsque des mesures certifi\u00e9es sont n\u00e9cessaires \u00e0 des fins de facturation. Sa certification MID garantit une mesure fiable de la consommation \u00e9lectrique et contribue \u00e0 assurer la transparence de la facturation pour les op\u00e9rateurs, les entreprises et les particuliers.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Au-del\u00e0 de la recharge des v\u00e9hicules \u00e9lectriques, les compteurs MID sont \u00e9galement utilis\u00e9s dans les <strong>installations industrielles, commerciales et r\u00e9sidentielles<\/strong>, o\u00f9 la pr\u00e9cision et la tra\u00e7abilit\u00e9 des donn\u00e9es \u00e9nerg\u00e9tiques sont essentielles.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Compteurs compatibles<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Monophas\u00e9 :<\/strong> CHINT DDSU666. Certains documents mentionnent la r\u00e9f\u00e9rence DSSU666. V\u00e9rifiez la r\u00e9f\u00e9rence exacte indiqu\u00e9e sur l\u2019\u00e9tiquette de votre compteur.<\/li>\n\n\n\n<li><strong>Trifas\u00e9 :<\/strong> CHINT DTSU666.<\/li>\n\n\n\n<li><strong>Autres mod\u00e8les :<\/strong> consultez la fiche technique du fabricant pour identifier les bornes \u00e9quivalentes \u00e0 celles indiqu\u00e9es dans ce guide.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Chargeurs compatibles<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Trydan<\/li>\n\n\n\n<li>Trydan Pro<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>&#x26a0;&#xfe0f; Attention :<\/strong> la tension du r\u00e9seau \u00e9lectrique pr\u00e9sente un risque d\u2019\u00e9lectrocution. Avant toute intervention sur le c\u00e2blage, coupez l\u2019alimentation du chargeur au niveau du disjoncteur et v\u00e9rifiez l\u2019absence de tension. L\u2019installation doit \u00eatre r\u00e9alis\u00e9e par un <strong>\u00e9lectricien qualifi\u00e9<\/strong>, conform\u00e9ment \u00e0 la r\u00e9glementation locale.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Concernant les num\u00e9ros de borne<\/strong> : les num\u00e9ros indiqu\u00e9s dans ce guide correspondent g\u00e9n\u00e9ralement \u00e0 ceux imprim\u00e9s sur les compteurs concern\u00e9s. Avant de raccorder un c\u00e2ble, v\u00e9rifiez syst\u00e9matiquement les rep\u00e8res figurant sur votre compteur ainsi que le sch\u00e9ma de raccordement pr\u00e9sent sur son \u00e9tiquette lat\u00e9rale.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-d7353680\"><h2 class=\"uagb-heading-text\">1. Raccordement \u00e9lectrique du compteur<strong> MID<\/strong><\/h2><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Le compteur MID s\u2019installe <strong>en s\u00e9rie sur la ligne d\u2019alimentation du chargeur<\/strong> afin de mesurer l\u2019\u00e9nergie consomm\u00e9e par celui-ci. Le courant alimentant le chargeur doit donc passer par le compteur, conform\u00e9ment au sch\u00e9ma de raccordement du mod\u00e8le utilis\u00e9.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Compteur monophas\u00e9 (DDSU666)<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Prise<\/th><th>Connexion<\/th><\/tr><\/thead><tbody><tr><td><strong>1<\/strong><\/td><td>Entr\u00e9e de phase (L), depuis le disjoncteur<\/td><\/tr><tr><td><strong>2<\/strong><\/td><td>Sortie de phase (L), vers le chargeur<\/td><\/tr><tr><td><strong>3<\/strong><\/td><td>Entr\u00e9e du neutre (N), depuis le r\u00e9seau<\/td><\/tr><tr><td><strong>4<\/strong><\/td><td>Sortie du neutre (N), vers le chargeur<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Coupez l\u2019alimentation du chargeur au niveau du disjoncteur.<\/li>\n\n\n\n<li>Raccordez la phase provenant du disjoncteur \u00e0 la <strong>borne 1<\/strong>.<\/li>\n\n\n\n<li>Raccordez un conducteur de phase entre la <strong>borne 2<\/strong> et la borne L du chargeur.<\/li>\n\n\n\n<li>Raccordez le neutre provenant du r\u00e9seau \u00e0 la <strong>borne 3<\/strong>.<\/li>\n\n\n\n<li>Raccordez un conducteur de neutre entre la <strong>borne 4<\/strong> et la borne N du chargeur.<\/li>\n\n\n\n<li>Le conducteur de terre (PE) <strong>ne passe pas par le compteur<\/strong>. Raccordez-le directement au chargeur, conform\u00e9ment au sch\u00e9ma \u00e9lectrique de l\u2019installation.<\/li>\n\n\n\n<li>V\u00e9rifiez le serrage de toutes les vis et assurez-vous qu\u2019aucun conducteur en cuivre d\u00e9nud\u00e9 ne d\u00e9passe des bornes.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\">Compteur triphas\u00e9 (DTSU666), raccordement direct \u00e0 4 fils<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Prise<\/th><th>Connexion<\/th><\/tr><\/thead><tbody><tr><td><strong>1<\/strong><\/td><td>Entr\u00e9e de phase L1, depuis le disjoncteur<\/td><\/tr><tr><td><strong>2<\/strong><\/td><td>Sortie de phase L1, vers le chargeur<\/td><\/tr><tr><td><strong>3<\/strong><\/td><td>Entr\u00e9e de phase L2, depuis le disjoncteur<\/td><\/tr><tr><td><strong>4<\/strong><\/td><td>Sortie de phase L2, vers le chargeur<\/td><\/tr><tr><td><strong>5<\/strong><\/td><td>Entr\u00e9e de phase L3, depuis le disjoncteur<\/td><\/tr><tr><td><strong>6<\/strong><\/td><td>Sortie de phase L3, vers le chargeur<\/td><\/tr><tr><td><strong>7<\/strong><\/td><td>Neutre (N), depuis le r\u00e9seau<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Coupez l\u2019alimentation du chargeur au niveau du disjoncteur.<\/li>\n\n\n\n<li>Raccordez les phases L1, L2 et L3 provenant du disjoncteur aux <strong>bornes 1, 3 et 5<\/strong>.<\/li>\n\n\n\n<li>Raccordez les <strong>bornes 2, 4 et 6<\/strong> aux bornes L1, L2 et L3 du chargeur, respectivement.<\/li>\n\n\n\n<li>Raccordez le neutre \u00e0 la <strong>borne 7<\/strong> et au bornier N du chargeur, conform\u00e9ment au sch\u00e9ma de raccordement du fabricant.<\/li>\n\n\n\n<li>Raccordez le conducteur de terre (PE) directement au chargeur, sans le faire passer par le compteur.<\/li>\n\n\n\n<li>V\u00e9rifiez le serrage des connexions et l\u2019ordre des phases.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Important :<\/strong> respectez les c\u00f4t\u00e9s entr\u00e9e et sortie et conservez le m\u00eame ordre de phases (L1, L2, L3) au niveau du compteur et du chargeur. Une inversion du sens de raccordement peut entra\u00eener une mesure n\u00e9gative ou incorrecte, selon le mod\u00e8le et sa configuration.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Si vous utilisez un compteur triphas\u00e9 dans une installation monophas\u00e9e, raccordez la phase \u00e0 L1 (<strong>bornes 1 et 2<\/strong>) et le neutre \u00e0 la <strong>borne 7<\/strong>, sous r\u00e9serve de compatibilit\u00e9 avec le mod\u00e8le utilis\u00e9. S\u00e9lectionnez ensuite le type de compteur install\u00e9 dans les param\u00e8tres du chargeur (voir section 4).<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Chargeurs \u00e9quip\u00e9s d\u2019un compteur MID int\u00e9gr\u00e9 en usine<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Lorsque le compteur MID est int\u00e9gr\u00e9 au chargeur en usine, il est aliment\u00e9 par la <strong>phase en sortie du bloc de protection<\/strong>. Comme illustr\u00e9 sur l\u2019image, le neutre (fil bleu) entre et sort par les connecteurs sup\u00e9rieures du compteur, tandis que la phase L1 entre et sort par les connecteurs inf\u00e9rieures. La communication est raccord\u00e9e au connecteur <strong>CON6 (A et B)<\/strong> de la carte de puissance.<\/p>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-a856e430 alignwide uagb-is-root-container\">\n<div class=\"wp-block-uagb-container uagb-block-1c381015\">\n<div class=\"wp-block-uagb-image uagb-block-88976d01 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-zoomin wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/v2charge.com\/wp-content\/uploads\/2025\/08\/medidor-mid.jpg ,https:\/\/v2charge.com\/wp-content\/uploads\/2025\/08\/medidor-mid.jpg 780w, https:\/\/v2charge.com\/wp-content\/uploads\/2025\/08\/medidor-mid.jpg 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2025\/08\/medidor-mid.jpg\" alt=\"\" class=\"uag-image-240966\" width=\"842\" height=\"610\" title=\"m\u00e8tre MID\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container margen-acordeon uagb-block-02f02898\">\n<div class=\"uagb-block-b2701ecb uagb-infobox__content-wrap  uagb-infobox-icon-left uagb-infobox-left uagb-infobox-stacked-tablet uagb-infobox-image-valign-top \"><div class=\"uagb-ifb-image-content\"><img decoding=\"async\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/numero-uno.png\" alt=\"\" width=\"25\" height=\"25\" loading=\"lazy\"\/><\/div><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><\/div><p class=\"uagb-ifb-desc\">Installation monophas\u00e9e<\/p><\/div><\/div>\n\n\n\n<div class=\"uagb-block-84c1f95e uagb-infobox__content-wrap  uagb-infobox-icon-left uagb-infobox-left uagb-infobox-stacked-tablet uagb-infobox-image-valign-top \"><div class=\"uagb-ifb-image-content\"><img decoding=\"async\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/numero-dos.png\" alt=\"\" width=\"25\" height=\"25\" loading=\"lazy\"\/><\/div><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><\/div><p class=\"uagb-ifb-desc\">Compteur MID<\/p><\/div><\/div>\n\n\n\n<div class=\"uagb-block-d2b382d2 uagb-infobox__content-wrap  uagb-infobox-icon-left uagb-infobox-left uagb-infobox-stacked-tablet uagb-infobox-image-valign-top \"><div class=\"uagb-ifb-image-content\"><img decoding=\"async\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/numero-tres.png\" alt=\"\" width=\"25\" height=\"25\" loading=\"lazy\"\/><\/div><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><\/div><p class=\"uagb-ifb-desc\">Plaque de puissance<\/p><\/div><\/div>\n\n\n\n<div class=\"uagb-block-510c4db1 uagb-infobox__content-wrap  uagb-infobox-icon-left uagb-infobox-left uagb-infobox-stacked-tablet uagb-infobox-image-valign-top \"><div class=\"uagb-ifb-image-content\"><img decoding=\"async\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/numero-cuatro.png\" alt=\"\" width=\"25\" height=\"25\" loading=\"lazy\"\/><\/div><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><\/div><p class=\"uagb-ifb-desc\">CON6 (A et B)<\/p><\/div><\/div>\n\n\n\n<div class=\"uagb-block-1b65eb79 uagb-infobox__content-wrap  uagb-infobox-icon-left uagb-infobox-left uagb-infobox-stacked-tablet uagb-infobox-image-valign-top \"><div class=\"uagb-ifb-image-content\"><img decoding=\"async\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/numero-cinco.png\" alt=\"\" width=\"25\" height=\"25\" loading=\"lazy\"\/><\/div><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><\/div><p class=\"uagb-ifb-desc\">C\u00e2ble de charge<\/p><\/div><\/div>\n\n\n\n<div class=\"uagb-block-617adc4f uagb-infobox__content-wrap  uagb-infobox-icon-left uagb-infobox-left uagb-infobox-stacked-tablet uagb-infobox-image-valign-top \"><div class=\"uagb-ifb-image-content\"><img decoding=\"async\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/12\/numero-seis.png\" alt=\"\" width=\"25\" height=\"25\" loading=\"lazy\"\/><\/div><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><\/div><p class=\"uagb-ifb-desc\">Bo\u00eetier de l&rsquo;e-Charger<\/p><\/div><\/div>\n<\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-c360059f\"><h2 class=\"uagb-heading-text\">2. Connexion des donn\u00e9es Modbus<strong> (RS485)<\/strong><\/h2><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Le compteur communique avec le chargeur via un bus <strong>Modbus RS485<\/strong>. Utilisez un c\u00e2ble blind\u00e9 \u00e0 paires torsad\u00e9es (par exemple, 2 \u00d7 0,5 mm\u00b2 ou une section \u00e9quivalente) et \u00e9loignez-le des c\u00e2bles d\u2019alimentation \u00e9lectrique afin de limiter les interf\u00e9rences.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">C\u00f4t\u00e9 du compteur<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Compteur<\/th><th>RS485 A (+)<\/th><th>RS485 B (\u2212)<\/th><\/tr><\/thead><tbody><tr><td><strong>Monophas\u00e9 (DDSU666)<\/strong><\/td><td>Bornier 5<\/td><td>Bornier 6<\/td><\/tr><tr><td><strong>Triphas\u00e9 (DTSU666)<\/strong><\/td><td>Bornier 24<\/td><td>Bornier 25<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">C\u00f4t\u00e9 chargeur (Trydan et Trydan Pro)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Sur le chargeur, raccordez le compteur au <strong>bornier RS485<\/strong> pr\u00e9vu pour la communication avec le compteur MID \/ Modbus. Les points de raccordement sont identifi\u00e9s par les lettres <strong>A et B<\/strong>.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>A (+) du compteur au bornier <strong>A (+)<\/strong> du chargeur.<\/li>\n\n\n\n<li>B (\u2212) du compteur au bornier <strong>B (\u2212)<\/strong> du chargeur.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Vous pouvez \u00e9galement utiliser un connecteur RJ45 avec un c\u00e2blage sp\u00e9cifique. Pour plus de d\u00e9tails, consultez le guide <a href=\"https:\/\/v2charge.com\/fr\/conexion-modbus-rtu-punto-de-recarga-trydan-para-medidor-como-esclavo\/\">Connexion Modbus RTU du Trydan avec un compteur comme esclave<\/a>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Recommandations pour le c\u00e2ble Modbus<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Respectez la correspondance des connexions : A avec A et B avec B.<\/li>\n\n\n\n<li>Si le compteur ne communique pas avec le chargeur, v\u00e9rifiez le c\u00e2blage et, si n\u00e9cessaire, testez l\u2019inversion des lignes A et B.<\/li>\n\n\n\n<li>Utilisez une paire torsad\u00e9e d\u00e9di\u00e9e \u00e0 la communication : un conducteur pour A et un autre pour B. Ne doublez pas les conducteurs pour augmenter la section.<\/li>\n\n\n\n<li>Utilisez un c\u00e2ble aussi court que possible et \u00e9loignez-le des c\u00e2bles d\u2019alimentation \u00e9lectrique.<\/li>\n\n\n\n<li>Ne r\u00e9tablissez l\u2019alimentation qu\u2019apr\u00e8s avoir v\u00e9rifi\u00e9 l\u2019ensemble des raccordements.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-3e8f3593\"><h2 class=\"uagb-heading-text\">3. Configuration du compteur<strong> MID<\/strong> depuis son \u00e9cran<\/h2><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Pour que le chargeur puisse communiquer avec le compteur, son adresse <strong>Modbus doit \u00eatre configur\u00e9e sur 11<\/strong>.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Param\u00e8tre<\/th><th>Valeur<\/th><\/tr><\/thead><tbody><tr><td><strong>Adresse Modbus (Addr)<\/strong><\/td><td>11 (obligatoire)<\/td><\/tr><tr><td><strong>Vitesse (bAUd)<\/strong><\/td><td>9600 (valeur d&rsquo;usine)<\/td><\/tr><tr><td><strong>Parit\u00e9 \/ format de donn\u00e9es<\/strong><\/td><td>8N1 : 8 bits de donn\u00e9es, sans parit\u00e9, 1 bit d\u2019arr\u00eat (valeur d\u2019usine)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">La vitesse de communication et le format des donn\u00e9es n\u2019ont pas besoin d\u2019\u00eatre modifi\u00e9s si les valeurs d\u2019usine sont bien de <strong>9600 bauds et 8N1<\/strong>. Seule l\u2019adresse Modbus doit imp\u00e9rativement \u00eatre r\u00e9gl\u00e9e sur <strong>11<\/strong>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Proc\u00e9dure g\u00e9n\u00e9rale (pour les deux compteurs)<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Mettez le compteur sous tension. L\u2019\u00e9cran affiche les valeurs mesur\u00e9es.<\/li>\n\n\n\n<li>Appuyez sur <strong>ENTER<\/strong> ou <strong>SET<\/strong>, selon le mod\u00e8le, pour acc\u00e9der au menu de configuration.<\/li>\n\n\n\n<li>Si un mot de passe est demand\u00e9, saisissez le <strong>mot de passe par d\u00e9faut 701<\/strong>, sous r\u00e9serve qu\u2019il corresponde \u00e0 votre mod\u00e8le. Utilisez les touches de navigation, puis confirmez avec ENTER.<\/li>\n\n\n\n<li>\u00c0 l\u2019aide des touches de navigation, acc\u00e9dez au menu des param\u00e8tres de communication.<\/li>\n\n\n\n<li>S\u00e9lectionnez le param\u00e8tre d\u2019adresse Modbus (<strong>Addr<\/strong>), r\u00e9glez-le sur <strong>11<\/strong>, puis confirmez avec ENTER.<\/li>\n\n\n\n<li>V\u00e9rifiez la vitesse de communication (<strong>bAUd<\/strong>) et le format des donn\u00e9es. Si n\u00e9cessaire, r\u00e9glez-les sur les valeurs indiqu\u00e9es dans le tableau, puis confirmez avec ENTER.<\/li>\n\n\n\n<li>Appuyez plusieurs fois sur <strong>ESC<\/strong> pour revenir \u00e0 l\u2019\u00e9cran de mesure. V\u00e9rifiez que les param\u00e8tres ont bien \u00e9t\u00e9 enregistr\u00e9s.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\">Compteur monophas\u00e9 (DDSU666)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Suivez la proc\u00e9dure g\u00e9n\u00e9rale. Apr\u00e8s avoir modifi\u00e9 l\u2019adresse, v\u00e9rifiez que le param\u00e8tre <strong>Addr<\/strong> affiche bien la valeur <strong>11<\/strong>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Compteur triphas\u00e9 (DTSU666)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Suivez la proc\u00e9dure g\u00e9n\u00e9rale. Ce mod\u00e8le propose des param\u00e8tres suppl\u00e9mentaires, notamment le rapport de transformation et le type de raccordement :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Rapport de transformation (CT) :<\/strong> 1 pour un compteur \u00e0 connexion directe, si cette valeur correspond \u00e0 votre mod\u00e8le.<\/li>\n\n\n\n<li><strong>Type de raccordement :<\/strong> triphas\u00e9 \u00e0 4 fils, pour une installation correspondant \u00e0 cette configuration.<\/li>\n\n\n\n<li><strong>Adresse Modbus :<\/strong> 11.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">V\u00e9rifiez le compteur<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Apr\u00e8s la configuration, v\u00e9rifiez que le compteur affiche toujours les valeurs de tension, de courant et d\u2019\u00e9nergie. Si les valeurs de tension ne s\u2019affichent pas, v\u00e9rifiez le raccordement \u00e9lectrique d\u00e9crit \u00e0 la section 1.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-3a30a855\"><h2 class=\"uagb-heading-text\">4. Configuration du Trydan depuis son<strong> \u00e9cran<\/strong><\/h2><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Ces \u00e9tapes sont identiques pour Trydan et Trydan Pro.<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Allumez le chargeur et attendez que l\u2019\u00e9cran principal s\u2019affiche.<\/li>\n\n\n\n<li>Acc\u00e9dez au menu de configuration en maintenant les deux boutons lat\u00e9raux enfonc\u00e9s. Pour plus d\u2019informations, consultez le guide sur<a href=\"https:\/\/v2charge.com\/fr\/soporte\/trydan\/botones-navegacion-display\/\">les boutons et la navigation de l&rsquo;\u00e9cran<\/a>.<\/li>\n\n\n\n<li>Acc\u00e9dez \u00e0 la section <strong>\u00abSuppl\u00e9mentaire\u00bb<\/strong>.<\/li>\n\n\n\n<li>S\u00e9lectionnez l&rsquo;option <strong>\u00abCompteur MID\u00bb<\/strong>.<\/li>\n\n\n\n<li>S\u00e9lectionnez le mod\u00e8le de compteur install\u00e9 : <strong>\u00ab Monophas\u00e9 \u00bb<\/strong> (DDSU666) ou <strong>\u00ab Triphas\u00e9 \u00bb<\/strong> (DTSU666). Les autres mod\u00e8les compatibles apparaissent \u00e9galement dans cette liste.<\/li>\n\n\n\n<li>Confirmez votre s\u00e9lection, puis revenez \u00e0 l\u2019\u00e9cran principal.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">Si aucun compteur MID n\u2019est install\u00e9, s\u00e9lectionnez l\u2019option <strong>\u00ab Non \u00bb<\/strong>.<\/p>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-d7888932 default uagb-is-root-container\">\n<div class=\"wp-block-uagb-container uagb-block-51c979ca\">\n<div class=\"wp-block-uagb-image uagb-block-522c59ec wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/06\/mid-meter-monophase.png ,https:\/\/v2charge.com\/wp-content\/uploads\/2024\/06\/mid-meter-monophase.png 780w, https:\/\/v2charge.com\/wp-content\/uploads\/2024\/06\/mid-meter-monophase.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/06\/mid-meter-monophase.png\" alt=\"\" class=\"uag-image-162500\" width=\"685\" height=\"166\" title=\"mesureur-mid-monophas\u00e9\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-c2a9fa26\">\n<div class=\"wp-block-uagb-image uagb-block-1dd3bb79 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/06\/mid-meter-non.png ,https:\/\/v2charge.com\/wp-content\/uploads\/2024\/06\/mid-meter-non.png 780w, https:\/\/v2charge.com\/wp-content\/uploads\/2024\/06\/mid-meter-non.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/06\/mid-meter-non.png\" alt=\"\" class=\"uag-image-162490\" width=\"685\" height=\"166\" title=\"mesureur-mid-non\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-971804f3\">\n<div class=\"wp-block-uagb-image uagb-block-8e1dc988 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/06\/mid-meter-triphase.png ,https:\/\/v2charge.com\/wp-content\/uploads\/2024\/06\/mid-meter-triphase.png 780w, https:\/\/v2charge.com\/wp-content\/uploads\/2024\/06\/mid-meter-triphase.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/06\/mid-meter-triphase.png\" alt=\"\" class=\"uag-image-162510\" width=\"685\" height=\"166\" title=\"mesureur-mid-triphase\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n<\/div>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading\">V\u00e9rification du fonctionnement du compteur<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Apr\u00e8s quelques secondes, le chargeur doit afficher les valeurs de puissance et d\u2019\u00e9nergie mesur\u00e9es par le compteur MID.<\/li>\n\n\n\n<li>Branchez un v\u00e9hicule ou activez une charge connue, puis v\u00e9rifiez que la puissance affich\u00e9e \u00e9volue. Les valeurs doivent \u00eatre coh\u00e9rentes et pr\u00e9senter le signe attendu, notamment une puissance positive pendant la recharge.<\/li>\n\n\n\n<li>Si les valeurs restent nulles ou si le chargeur affiche une erreur de communication avec le compteur, consultez la section 5.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-23dfb36f\"><h2 class=\"uagb-heading-text\">5. R\u00e9solution de<strong> probl\u00e8mes<\/strong><\/h2><\/div>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Probl\u00e8me<\/th><th><strong>Points \u00e0 v\u00e9rifier<\/strong><\/th><\/tr><\/thead><tbody><tr><td><strong><strong>Absence de communication ou erreur de communication<\/strong><\/strong><\/td><td>V\u00e9rifiez que l\u2019adresse Modbus du compteur est r\u00e9gl\u00e9e sur 11, que la vitesse et le format des donn\u00e9es sont bien configur\u00e9s sur 9600 bauds et 8N1, que les connexions RS485 A et B sont correctes et que le bon mod\u00e8le de compteur (monophas\u00e9 ou triphas\u00e9) est s\u00e9lectionn\u00e9 sur l\u2019\u00e9cran du chargeur. Si n\u00e9cessaire, testez l\u2019inversion des lignes A et B apr\u00e8s avoir coup\u00e9 l\u2019alimentation.<\/td><\/tr><tr><td><strong><strong>Valeur d\u2019\u00e9nergie ou de puissance n\u00e9gative<\/strong><\/strong><\/td><td>V\u00e9rifiez que les c\u00e2bles d\u2019entr\u00e9e et de sortie du compteur ne sont pas invers\u00e9s et corrigez le raccordement si n\u00e9cessaire.<\/td><\/tr><tr><td><strong><strong>\u00c9cran du compteur \u00e9teint<\/strong><\/strong><\/td><td>V\u00e9rifiez que le compteur est aliment\u00e9 et contr\u00f4lez le disjoncteur ainsi que les raccordements aux bornes 1 et 3 pour le mod\u00e8le monophas\u00e9, ou 1, 3, 5 et 7 pour le mod\u00e8le triphas\u00e9, conform\u00e9ment au sch\u00e9ma du fabricant.<\/td><\/tr><tr><td><strong><strong>Valeur de puissance incorrecte dans une installation triphas\u00e9e<\/strong><\/strong><\/td><td>V\u00e9rifiez l\u2019ordre des phases L1, L2 et L3 ainsi que la configuration du type de raccordement, qui doit \u00eatre r\u00e9gl\u00e9 sur triphas\u00e9 \u00e0 4 fils lorsque cette configuration correspond \u00e0 l\u2019installation.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer uag-hide-mob\"><\/div>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-c6f38013 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-advanced-heading uagb-block-6963d70c\"><h2 class=\"uagb-heading-text\"><strong><strong>Vous avez besoin d\u2019assistance technique ?<\/strong><\/strong><\/h2><\/div>\n\n\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-408243eb\"><p class=\"uagb-heading-text\">Obtenez une r\u00e9ponse instantan\u00e9e gr\u00e2ce \u00e0<strong> notre assistant IA. <\/strong>Si votre probl\u00e8me ne peut pas \u00eatre r\u00e9solu automatiquement, cr\u00e9ez une demande aupr\u00e8s du <strong>Centre d\u2019assistance technique.<\/strong> Notre \u00e9quipe vous contactera dans les plus brefs d\u00e9lais afin de vous accompagner et de vous proposer la meilleure solution.<\/p><\/div>\n\n\n\n<div class=\"uagb-block-12e3cf1c uagb-infobox__content-wrap  uagb-infobox-icon-left uagb-infobox-left uagb-infobox-image-valign-top  wp-block-uagb-info-box--has-margin\"><div class=\"uagb-infobox-margin-wrapper\"><div class=\"uagb-ifb-image-content\"><img decoding=\"async\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2026\/01\/support-ai-chatbot.png\" alt=\"\" width=\"20\" height=\"19\" loading=\"lazy\"\/><\/div><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><\/div><div class=\"uagb-ifb-button-wrapper wp-block-button\"><a href=\"https:\/\/v2charge.com\/v2c-support-web\/\" class=\"uagb-infobox-cta-link wp-block-button__link\" target=\"_blank\" rel=\"noopener noreferrer\" onclick=\"return true;\"><span class=\"uagb-inline-editing\">Posez votre question \u00e0 notre chat avec IA<\/span><\/a><\/div><\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-buttons uagb-buttons__outer-wrap uagb-btn__default-btn uagb-btn-tablet__default-btn uagb-btn-mobile__default-btn uagb-block-ba1e67d1\"><div class=\"uagb-buttons__wrap uagb-buttons-layout-wrap \">\n<div class=\"wp-block-uagb-buttons-child uagb-buttons__outer-wrap uagb-block-23cfb623 wp-block-button\"><div class=\"uagb-button__wrapper\"><a class=\"uagb-buttons-repeater wp-block-button__link\" aria-label=\"\" href=\"https:\/\/servicedesk.v2charge.com\" rel=\"follow noopener\" target=\"_blank\" role=\"button\"><div class=\"uagb-button__link\">Contactez le Support Technique<\/div><\/a><\/div><\/div>\n<\/div><\/div>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Comment connecter et configurer le compteur MID sur Trydan et Trydan Pro ? Le compteur MID est un dispositif de mesure \u00e9lectrique conforme aux exigences de la directive europ\u00e9enne 2014\/32\/UE, \u00e9galement appel\u00e9e directive MID (Measuring Instruments Directive). Il permet de mesurer avec pr\u00e9cision l\u2019\u00e9nergie consomm\u00e9e lors de la recharge des v\u00e9hicules \u00e9lectriques, notamment lorsque des &#8230; <a title=\"Comment connecter et configurer le compteur MID sur Trydan\/Trydan Pro\" class=\"read-more\" href=\"https:\/\/v2charge.com\/fr\/support\/trydan\/mid-meter\/\" aria-label=\"Read more about Comment connecter et configurer le compteur MID sur Trydan\/Trydan Pro\">Lire la suite<\/a><\/p>\n","protected":false},"author":400,"featured_media":0,"parent":75498,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_eb_attr":"","content-type":"","_uag_custom_page_level_css":"","footnotes":""},"class_list":["post-241024","page","type-page","status-publish"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Comment connecter et configurer le compteur MID sur Trydan\/Trydan Pro | V2C<\/title>\n<meta name=\"description\" content=\"D\u00e9couvrez comment connecter et configurer le compteur MID sur Trydan\/Trydan Pro pour enregistrer avec pr\u00e9cision l&#039;\u00e9nergie consomm\u00e9e lors des recharges de VE.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/v2charge.com\/fr\/support\/trydan\/mid-meter\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Comment connecter et configurer le compteur MID sur Trydan\/Trydan Pro | V2C\" \/>\n<meta property=\"og:description\" content=\"D\u00e9couvrez comment connecter et configurer le compteur MID sur Trydan\/Trydan Pro pour enregistrer avec pr\u00e9cision l&#039;\u00e9nergie consomm\u00e9e lors des recharges de VE.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/v2charge.com\/fr\/support\/trydan\/mid-meter\/\" \/>\n<meta property=\"og:site_name\" content=\"V2C\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/V2C.Charge\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-20T12:09:58+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/v2charge.com\/wp-content\/uploads\/2025\/08\/medidor-mid.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@V2C_Charge\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"11 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/v2charge.com\\\/fr\\\/support\\\/trydan\\\/mid-meter\\\/\",\"url\":\"https:\\\/\\\/v2charge.com\\\/fr\\\/support\\\/trydan\\\/mid-meter\\\/\",\"name\":\"Comment connecter et configurer le compteur MID sur Trydan\\\/Trydan Pro | V2C\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/v2charge.com\\\/fr\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/v2charge.com\\\/fr\\\/support\\\/trydan\\\/mid-meter\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/v2charge.com\\\/fr\\\/support\\\/trydan\\\/mid-meter\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/v2charge.com\\\/wp-content\\\/uploads\\\/2025\\\/08\\\/medidor-mid.jpg\",\"datePublished\":\"2025-08-01T10:58:14+00:00\",\"dateModified\":\"2026-10-20T12:09:58+00:00\",\"description\":\"D\u00e9couvrez comment connecter et configurer le compteur MID sur Trydan\\\/Trydan Pro pour enregistrer avec pr\u00e9cision l'\u00e9nergie consomm\u00e9e lors des recharges de VE.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/v2charge.com\\\/fr\\\/support\\\/trydan\\\/mid-meter\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/v2charge.com\\\/fr\\\/support\\\/trydan\\\/mid-meter\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/v2charge.com\\\/fr\\\/support\\\/trydan\\\/mid-meter\\\/#primaryimage\",\"url\":\"https:\\\/\\\/v2charge.com\\\/wp-content\\\/uploads\\\/2025\\\/08\\\/medidor-mid.jpg\",\"contentUrl\":\"https:\\\/\\\/v2charge.com\\\/wp-content\\\/uploads\\\/2025\\\/08\\\/medidor-mid.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/v2charge.com\\\/fr\\\/support\\\/trydan\\\/mid-meter\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"V2C\",\"item\":\"https:\\\/\\\/v2charge.com\\\/fr\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Support Area\",\"item\":\"https:\\\/\\\/v2charge.com\\\/fr\\\/support\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Support Trydan\",\"item\":\"https:\\\/\\\/v2charge.com\\\/fr\\\/support\\\/trydan\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Comment connecter et configurer le compteur MID sur Trydan\\\/Trydan Pro\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/v2charge.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/v2charge.com\\\/fr\\\/\",\"name\":\"V2C\",\"description\":\"#CargandoElMa\u00f1ana\",\"publisher\":{\"@id\":\"https:\\\/\\\/v2charge.com\\\/fr\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/v2charge.com\\\/fr\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/v2charge.com\\\/fr\\\/#organization\",\"name\":\"V2C\",\"url\":\"https:\\\/\\\/v2charge.com\\\/fr\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/v2charge.com\\\/fr\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/v2charge.com\\\/wp-content\\\/uploads\\\/2024\\\/11\\\/cropped-v2c-charge-logo-menu.png\",\"contentUrl\":\"https:\\\/\\\/v2charge.com\\\/wp-content\\\/uploads\\\/2024\\\/11\\\/cropped-v2c-charge-logo-menu.png\",\"width\":984,\"height\":431,\"caption\":\"V2C\"},\"image\":{\"@id\":\"https:\\\/\\\/v2charge.com\\\/fr\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/V2C.Charge\",\"https:\\\/\\\/x.com\\\/V2C_Charge\",\"https:\\\/\\\/www.instagram.com\\\/v2c.charge\\\/\",\"https:\\\/\\\/www.youtube.com\\\/@V2C\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/v2c-chargers\\\/\"],\"contactPoint\":[{\"@type\":\"ContactPoint\",\"contactType\":\"customer support\",\"telephone\":\"+34960654554\",\"email\":\"info@v2charge.com\",\"availableLanguage\":[\"Spanish\",\"English\",\"Portuguese\",\"French\"]},{\"@type\":\"ContactPoint\",\"contactType\":\"sales\",\"telephone\":\"+34960654554\",\"email\":\"info@v2charge.com\",\"availableLanguage\":[\"Spanish\",\"English\"]}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Comment connecter et configurer le compteur MID sur Trydan\/Trydan Pro | V2C","description":"D\u00e9couvrez comment connecter et configurer le compteur MID sur Trydan\/Trydan Pro pour enregistrer avec pr\u00e9cision l'\u00e9nergie consomm\u00e9e lors des recharges de VE.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/v2charge.com\/fr\/support\/trydan\/mid-meter\/","og_locale":"fr_FR","og_type":"article","og_title":"Comment connecter et configurer le compteur MID sur Trydan\/Trydan Pro | V2C","og_description":"D\u00e9couvrez comment connecter et configurer le compteur MID sur Trydan\/Trydan Pro pour enregistrer avec pr\u00e9cision l'\u00e9nergie consomm\u00e9e lors des recharges de VE.","og_url":"https:\/\/v2charge.com\/fr\/support\/trydan\/mid-meter\/","og_site_name":"V2C","article_publisher":"https:\/\/www.facebook.com\/V2C.Charge","article_modified_time":"2026-10-20T12:09:58+00:00","og_image":[{"url":"https:\/\/v2charge.com\/wp-content\/uploads\/2025\/08\/medidor-mid.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_site":"@V2C_Charge","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"11 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/v2charge.com\/fr\/support\/trydan\/mid-meter\/","url":"https:\/\/v2charge.com\/fr\/support\/trydan\/mid-meter\/","name":"Comment connecter et configurer le compteur MID sur Trydan\/Trydan Pro | V2C","isPartOf":{"@id":"https:\/\/v2charge.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/v2charge.com\/fr\/support\/trydan\/mid-meter\/#primaryimage"},"image":{"@id":"https:\/\/v2charge.com\/fr\/support\/trydan\/mid-meter\/#primaryimage"},"thumbnailUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2025\/08\/medidor-mid.jpg","datePublished":"2025-08-01T10:58:14+00:00","dateModified":"2026-10-20T12:09:58+00:00","description":"D\u00e9couvrez comment connecter et configurer le compteur MID sur Trydan\/Trydan Pro pour enregistrer avec pr\u00e9cision l'\u00e9nergie consomm\u00e9e lors des recharges de VE.","breadcrumb":{"@id":"https:\/\/v2charge.com\/fr\/support\/trydan\/mid-meter\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/v2charge.com\/fr\/support\/trydan\/mid-meter\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/v2charge.com\/fr\/support\/trydan\/mid-meter\/#primaryimage","url":"https:\/\/v2charge.com\/wp-content\/uploads\/2025\/08\/medidor-mid.jpg","contentUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2025\/08\/medidor-mid.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/v2charge.com\/fr\/support\/trydan\/mid-meter\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"V2C","item":"https:\/\/v2charge.com\/fr\/"},{"@type":"ListItem","position":2,"name":"Support Area","item":"https:\/\/v2charge.com\/fr\/support\/"},{"@type":"ListItem","position":3,"name":"Support Trydan","item":"https:\/\/v2charge.com\/fr\/support\/trydan\/"},{"@type":"ListItem","position":4,"name":"Comment connecter et configurer le compteur MID sur Trydan\/Trydan Pro"}]},{"@type":"WebSite","@id":"https:\/\/v2charge.com\/fr\/#website","url":"https:\/\/v2charge.com\/fr\/","name":"V2C","description":"#CargandoElMa\u00f1ana","publisher":{"@id":"https:\/\/v2charge.com\/fr\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/v2charge.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/v2charge.com\/fr\/#organization","name":"V2C","url":"https:\/\/v2charge.com\/fr\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/v2charge.com\/fr\/#\/schema\/logo\/image\/","url":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png","contentUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png","width":984,"height":431,"caption":"V2C"},"image":{"@id":"https:\/\/v2charge.com\/fr\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/V2C.Charge","https:\/\/x.com\/V2C_Charge","https:\/\/www.instagram.com\/v2c.charge\/","https:\/\/www.youtube.com\/@V2C","https:\/\/www.linkedin.com\/company\/v2c-chargers\/"],"contactPoint":[{"@type":"ContactPoint","contactType":"customer support","telephone":"+34960654554","email":"info@v2charge.com","availableLanguage":["Spanish","English","Portuguese","French"]},{"@type":"ContactPoint","contactType":"sales","telephone":"+34960654554","email":"info@v2charge.com","availableLanguage":["Spanish","English"]}]}]}},"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"gs-tiny":false,"xl":false,"xxl":false,"xxxl":false,"xxxxl":false,"xxxxxl":false,"1536x1536":false,"2048x2048":false},"uagb_author_info":{"display_name":"V2C","author_link":"https:\/\/v2charge.com\/fr\/author\/marketing\/"},"uagb_comment_info":0,"uagb_excerpt":"Comment connecter et configurer le compteur MID sur Trydan et Trydan Pro ? Le compteur MID est un dispositif de mesure \u00e9lectrique conforme aux exigences de la directive europ\u00e9enne 2014\/32\/UE, \u00e9galement appel\u00e9e directive MID (Measuring Instruments Directive). Il permet de mesurer avec pr\u00e9cision l\u2019\u00e9nergie consomm\u00e9e lors de la recharge des v\u00e9hicules \u00e9lectriques, notamment lorsque des\u2026","_links":{"self":[{"href":"https:\/\/v2charge.com\/fr\/wp-json\/wp\/v2\/pages\/241024","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/v2charge.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/v2charge.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/v2charge.com\/fr\/wp-json\/wp\/v2\/users\/400"}],"replies":[{"embeddable":true,"href":"https:\/\/v2charge.com\/fr\/wp-json\/wp\/v2\/comments?post=241024"}],"version-history":[{"count":5,"href":"https:\/\/v2charge.com\/fr\/wp-json\/wp\/v2\/pages\/241024\/revisions"}],"predecessor-version":[{"id":429689,"href":"https:\/\/v2charge.com\/fr\/wp-json\/wp\/v2\/pages\/241024\/revisions\/429689"}],"up":[{"embeddable":true,"href":"https:\/\/v2charge.com\/fr\/wp-json\/wp\/v2\/pages\/75498"}],"wp:attachment":[{"href":"https:\/\/v2charge.com\/fr\/wp-json\/wp\/v2\/media?parent=241024"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}