{"id":187050,"date":"2024-11-07T13:52:13","date_gmt":"2024-11-07T11:52:13","guid":{"rendered":"https:\/\/v2charge.com\/?page_id=187050"},"modified":"2026-01-13T16:46:31","modified_gmt":"2026-01-13T14:46:31","slug":"risoluzione-errori","status":"publish","type":"page","link":"https:\/\/v2charge.com\/it\/supporto\/controllo-potenza\/dinamico\/risoluzione-errori\/","title":{"rendered":"Codici di errore di connessione e soluzioni"},"content":{"rendered":"\n<div class=\"wp-block-uagb-container uagb-block-9d828d1c alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><div class=\"yoast-breadcrumbs\"><span><span><a href=\"https:\/\/v2charge.com\/it\/\">V2C<\/a><\/span> \u00bb <span><a href=\"https:\/\/v2charge.com\/it\/supporto\/\">Area di supporto<\/a><\/span> \u00bb <span><a href=\"https:\/\/v2charge.com\/it\/supporto\/controllo-potenza\/\">Controllo di potenza<\/a><\/span> \u00bb <span><a href=\"https:\/\/v2charge.com\/it\/supporto\/controllo-potenza\/dinamico\/\">Dinamico<\/a><\/span> \u00bb <span class=\"breadcrumb_last\" aria-current=\"page\">Codici di errore di connessione e soluzioni<\/span><\/span><\/div>\n\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-be8360a4\"><h1 class=\"uagb-heading-text\">Codici di errore di connessione e soluzioni<\/h1><\/div>\n\n\n\n<p>Se durante l&#8217;attivazione del controllo dinamico della potenza nel caricatore Trydan o Trydan Pro si verifica un errore, sul display del caricatore apparir\u00e0 un <strong>codice corrispondente<\/strong>.<br><br>Le soluzioni agli errori riportate di seguito si applicano alla versione 1.6.18 o superiore. Se disponi di una versione precedente, <a href=\"https:\/\/v2charge.com\/it\/supporto\/trydan\/aggiornamento-ultima-versione\/\"><strong>aggiorna il caricatore Trydan<\/strong><\/a> e verifica nuovamente la lista seguente.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-f83ba0fb alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-9d537ef2\">\n<div class=\"wp-block-uagb-container uagb-block-1021f2c1\">\n<div class=\"wp-block-uagb-image aligncenter uagb-block-f5b78000 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-center\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png ,https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png 780w, https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png\" alt=\"\" class=\"uag-image-125013\" width=\"50\" height=\"50\" title=\"\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-a8351972\">\n<div class=\"wp-block-uagb-advanced-heading uagb-block-fdcb9def\"><p class=\"uagb-heading-text\"><strong>NOTA IMPORTANTE<\/strong>: Questi errori derivano da un problema di comunicazione tra Trydan e l&#8217;inverter o il contatore, limitando la carica del veicolo al minimo. Alcuni errori possono verificarsi quando l&#8217;integrazione \u00e8 diretta con l&#8217;inverter, sia tramite comunicazione Modbus che RS485.<br><strong>\u00c8 fondamentale consultare la soluzione per l\u2019errore visualizzato sul display.<\/strong> In caso di persistenza dell&#8217;errore, contatta il nostro dipartimento di Supporto Tecnico e disattiva il controllo dinamico di carica per poter caricare alla potenza fissa impostata.<\/p><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-separator uagb-block-b0f92113\"><div class=\"wp-block-uagb-separator__inner\" style=\"--my-background-image:\"><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-d29bd849\">\n<div class=\"wp-block-uagb-container uagb-block-76539b06\">\n<table style=\"border:none;\">\n    <tr style=\"border:none;\">\n        <th style=\"border:none;\">ERROR<\/th>\n        <th style=\"border:none;\"><u>00<\/u><\/th>\n        <th style=\"border:none;\"><u>000<\/u><\/th>\n    <\/tr>\n    <tr style=\"border:none;\">\n        <td style=\"border:none;\"><\/td>\n        <td style=\"border:none;\"><center>A<\/center><\/td>\n        <td style=\"border:none;\"><center>B<\/center><\/td>\n    <\/tr>\n<\/table>\n<\/div>\n<\/div>\n\n\n\n<p>Le <strong>prime due cifre<\/strong> indicano il contatore o l&#8217;inverter utilizzato. \u00c8 importante selezionare quello corretto quando si imposta il controllo dinamico della potenza e verificarne la correttezza in caso di errore.<\/p>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-ac759e73\">\n<div class=\"wp-block-uagb-container uagb-block-e7b117bf\">\n<p><strong>Errori &#8211; A<\/strong><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-c1613651\">\n<p><strong>00<\/strong>  Contatore Shelly<br><strong>01<\/strong>   V2C ControlBox<br><strong>02<\/strong>  Contatore V2C 1.0<br><strong>03<\/strong>  Collegamento dell&#8217;inverter Huawei<br><strong>04<\/strong>  Collegamento dell&#8217;inverter Solax<br><strong>05<\/strong>  Collegamento dell&#8217;inverter Kostal<br><strong>06<\/strong>  Collegamento dell&#8217;inverter Fronius<br><strong>07<\/strong>  Collegamento dell&#8217;inverter Ingeteam<br><strong>08  <\/strong>Collegamento al contatore Wibeee<br><strong>09<\/strong>  Collegamento al contatore Victron<br><strong>10<\/strong>  Collegamento dell&#8217;inverter SolarEdge<br><strong>11<\/strong>  Utilizzo del protocollo MQTT<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-891a5dcc\">\n<p><strong>12<\/strong> Collegamento dell&#8217;inverter Goodwe<br><strong>13<\/strong> Collegamento dell&#8217;inverter SAJ \/ GreenHeiss<br><strong>14<\/strong> Collegamento dell&#8217;inverter Solis<br><strong>15<\/strong> Collegamento al contatore Chint DDSU666<br><strong>16<\/strong> Collegamento al contatore Eastron<br><strong>17<\/strong> Collegamento al contatore Phoneix Contact<br><strong>18<\/strong> Collegamento al contatore Carlo Gavazzi<br><strong>19<\/strong> Collegamento al contatore SMA<br><strong>20<\/strong> Collegamento dell&#8217;inverter Deye \/ Turbo Energy<br><strong>21<\/strong> Collegamento dell&#8217;inverter ENPHASE<br><strong>22<\/strong> Collegamento al contatore WiFi P1 Meter<br><strong>23<\/strong> Collegamento tramite Modbus<br><strong>25<\/strong> Collegamento al contatore Shelly Pro<br><strong>26<\/strong> Collegamento all\u2019inverter Growatt<br><strong>27<\/strong> Collegamento all\u2019inverter Sungrow<br><strong>28 <\/strong>Connessione al contatore LINKY LORA<br><strong>94<\/strong> Misura Car fuori range<br><strong>95 <\/strong>Misura Grid fuori intervallo<br><strong>96 <\/strong>Misura House fuori intervallo<br><strong>97 <\/strong>Misura Battery fuori intervallo<br><strong>98 <\/strong>Misura PV fuori intervallo<br><strong>99<\/strong> Collegamento tra due caricabatterie Trydan in modalit\u00e0 di bilanciamento del carico<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-separator uagb-block-b634b355\"><div class=\"wp-block-uagb-separator__inner\" style=\"--my-background-image:\"><\/div><\/div>\n\n\n\n<p><strong>Errori &#8211; B<\/strong><\/p>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-dab21eca\">\n<div class=\"wp-block-uagb-container uagb-block-6f899c4f\">\n<p><strong>000 Misure fuori range.<\/strong><br><strong>Verificare<\/strong>:<br>\u2013 Se il caricatore dispone di un contatore interno. Verificare la marca, se \u00e8 monofase o trifase, e configurarlo sul caricatore tramite il pannello di controllo, oppure contattare l\u2019assistenza per configurarlo da remoto se il caricatore \u00e8 online.<br>\u2013 Il corretto collegamento fisico del contatore alla scheda di potenza.<br><br><strong><strong>001 <\/strong><\/strong>Per apparecchiature Goodwe con protocollo UDP<br><strong><strong>Controllo:<\/strong><\/strong><br>&#8211; Sia l&#8217;inverter che il caricatore sono collegati a Internet..<br> &#8211; L&#8217;IP dell&#8217;inverter non \u00e8 assegnato correttamente nell&#8217;e-Charger.<br><br><strong>002 <\/strong>Per i misuratori V2C 1.0 e 2.0: i fotogrammi arrivano danneggiati.<strong><br>Controllo<\/strong>:<br>&#8211; Corretta crimpatura del connettore RJ-45 su entrambe le estremit\u00e0.<br>&#8211; Configurazione corretta del controllo dinamico con il contatore selezionato corrispondente all&#8217;installazione.<br><br><strong>003<\/strong> Possibile rumore nel segnale del V2C ControlBox.<br><strong><strong>Controllo<\/strong>:<br><\/strong>&#8211; Corretta crimpatura del connettore RJ-45 su entrambe le estremit\u00e0.<br>&#8211; Configurazione corretta del controllo dinamico con il contatore selezionato corrispondente all&#8217;installazione.<br><br><strong>004<\/strong> Trydan \u00e8 disconnesso dal WiFi e sta cercando di riconnettersi e il misuratore WiFi utilizza la tecnologia WiFi per connettersi.<br><strong><strong>Controllo<\/strong><\/strong>:<br>&#8211; Collegamento corretto di entrambi i dispositivi allo stesso client WiFi (non al caricatore).<br>&#8211; La potenza del segnale deve essere ottimale o la connessione WiFi a cui sono collegati entrambi deve essere migliorata con un ripetitore.<br><br><strong>005<\/strong> Lo V2C ControlBox collegato tramite RJ-45 non risponde.<br><strong><strong>Controllo<\/strong><\/strong>:<br>&#8211; Corretta crimpatura del connettore RJ-45 su entrambe le estremit\u00e0.<br><br><strong>006<\/strong> La richiesta HTTP viene effettuata e la connessione non riesce (Shelly, Solax, Kostal Piko, Enphase, P1 Meter, SAJ [Solar Data], Wibeee). Impossibile connettersi al server Modbus TCP (Huawei, Kostal Plenticore, Fronius, Ingeteam, SMA Sunny, SolarEdge, Victron).<br><strong><strong>Controllo<\/strong><\/strong>:<br>&#8211; Collegamento corretto di entrambi i dispositivi allo stesso client WiFi (non al caricatore).<br>&#8211; L&#8217;IP dell&#8217;inverter non \u00e8 assegnato correttamente nell&#8217;e-Charger.<br>&#8211; La potenza del segnale deve essere ottimale o la connessione WiFi a cui sono collegati entrambi deve essere migliorata con un ripetitore.<br>&#8211; Configurazione corretta dell&#8217;inverter rispetto ai parametri della comunicazione con Trydan.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-946f340c\">\n<p><strong>007<\/strong>  La ricerca automatica di Shelly non ha trovato alcun dispositivo.<br><strong><strong>Controllo<\/strong><\/strong>:<br>&#8211; Passaggio all&#8217;IP fisso dello Shelly nel caricatore Trydan.<br>&#8211; Collegamento corretto di entrambi i dispositivi allo stesso client WiFi (non al caricatore).<br><br><strong>008<\/strong>  \u00c8 stato selezionato uno strumento abilitato al WiFi e Trydan non si \u00e8 mai connesso alla rete WiFi configurata.<br><strong><strong>Controllo<\/strong><\/strong>:<br>&#8211; Collegamento corretto di entrambi i dispositivi allo stesso client WiFi con segnale sufficiente (non al caricatore).<br><br><strong>009  <\/strong>Viene ricevuto un timeout della richiesta al contatore.<br><strong><strong>Controllo<\/strong><\/strong>:<br>&#8211; Corretta crimpatura del connettore RJ-45 su entrambe le estremit\u00e0.<br>&#8211; Configurazione corretta dell&#8217;inverter rispetto ai parametri della comunicazione con Trydan.<br>&#8211; Nel caso di un inverter o di un misuratore WiFi, \u00e8 necessario collegare correttamente entrambi i dispositivi allo stesso WiFi del cliente con un segnale sufficiente (non al caricatore).<br>&#8211; L&#8217;IP dell&#8217;inverter e configurarlo correttamente nel Trydan dynamic power control.<br>-Inverter Solax: versione corretta di Pocket WiFi V2.033.20 (link per il download incluso nel manuale).<br><br><strong>010<\/strong>  I dati vengono ricevuti da una pinza non collegata su un canale richiesto.<br>(pinza mono + PV 1 o 4, pinza trifase 1, 2 o 3)<br><strong><strong>Controllo<\/strong><\/strong>:<br>&#8211; Posizionare correttamente i morsetti nelle fasi indicate nello schema di installazione corretto per ogni caso.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-00168f44\">\n<div class=\"wp-block-uagb-container uagb-block-c837e147\">\n<div class=\"wp-block-uagb-image aligncenter uagb-block-ded0ddba wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-center\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png ,https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png 780w, https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png\" alt=\"\" class=\"uag-image-125013\" width=\"50\" height=\"50\" title=\"\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-421a53a1\">\n<div class=\"wp-block-uagb-advanced-heading uagb-block-ab21f8f7\"><p class=\"uagb-heading-text\"><strong>NOTA IMPORTANTE:<\/strong> Se il <strong>codice di errore \u00e8 superiore a 011, si tratta di errori del protocollo MODBUS RTU o TCP. Solo per personale specializzato.<\/strong> Potete generare una richiesta nel Centro di assistenza tecnica e sarete contattati al pi\u00f9 presto.<\/p><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-a889f73f\">\n<div class=\"wp-block-uagb-container uagb-block-3ced5973\">\n<p><strong>021 <\/strong> LLEGAL_FUNCTION<br><strong>022<\/strong> ILLEGAL_DATA_ADDRESS<br><strong>023<\/strong> ILLEGAL_DATA_VALUE<br><strong>024<\/strong> SERVER_DEVICE_FAILURE<br><strong>025<\/strong> ACKNOWLEDGE<br><strong>026<\/strong> SERVER_DEVICE_BUSY<br><strong>027<\/strong> NEGATIVE_ACKNOWLEDGE<br><strong>028<\/strong> MEMORY_PARITY_ERROR<br><strong>030<\/strong> GATEWAY_PATH_UNAVAIL<br><strong>031<\/strong> GATEWAY_TARGET_NO_RESP<br><strong>032<\/strong> SERVER_RTU_INACTIVE<br><strong>244<\/strong> TIMEOUT<br><strong>245<\/strong> INVALID_SERVER<br><strong>246<\/strong> CRC_ERROR<br><strong>247<\/strong> FC_MISMATCH<br><strong>248<\/strong> SERVER_ID_MISMATCH<br><strong>249<\/strong> PACKET_LENGTH_ERROR<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-70caf82a\">\n<p><strong>250<\/strong>  PARAMETER_COUNT_ERROR<br><strong>251<\/strong>  PARAMETER_LIMIT_ERROR<br><strong>252<\/strong>  REQUEST_QUEUE_FULL<br><strong>253<\/strong>  ILLEGAL_IP_OR_PORT<br><strong>254<\/strong>  IP_CONNECTION_FAILED<br><strong>255<\/strong>  TCP_HEAD_MISMATCH<br><strong>256<\/strong>  EMPTY_MESSAGE<br><strong>275 <\/strong> UNDEFINED_ERROR<\/p>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-c6f38013 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-advanced-heading uagb-block-6963d70c\"><h2 class=\"uagb-heading-text\"><strong>Hai bisogno di supporto tecnico?<\/strong><\/h2><\/div>\n\n\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-408243eb\"><p class=\"uagb-heading-text\">Resuelve tu incidencia al instante a trav\u00e9s de nuestro Chat con IA. Si no se resuelve, genera una solicitud en el Centro de Soporte T\u00e9cnico y nos pondremos en contacto contigo lo antes posible para ofrecerte la mejor soluci\u00f3n.<\/p><\/div>\n\n\n\n<div class=\"wp-block-uagb-info-box uagb-block-12e3cf1c uagb-infobox__content-wrap  uagb-infobox-icon-left uagb-infobox-left uagb-infobox-image-valign-top wp-block-uagb-info-box--has-margin ai-chatbot-button\"><div class=\"uagb-infobox-margin-wrapper\"><div class=\"uagb-ifb-image-content\"><img decoding=\"async\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2026\/01\/support-ai-chatbot.png\" alt=\"\" width=\"20\" height=\"19\" loading=\"lazy\"\/><\/div><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><\/div><div class=\"uagb-ifb-button-wrapper wp-block-button\"><a href=\"https:\/\/v2charge.com\/v2c-support-web\/\" class=\"uagb-infobox-cta-link wp-block-button__link\" target=\"_blank\" rel=\"noopener noreferrer\" onclick=\"return true;\"><span class=\"uagb-inline-editing\">Chiedi alla nostra Chat con IA<\/span><\/a><\/div><\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-buttons uagb-buttons__outer-wrap uagb-btn__default-btn uagb-btn-tablet__default-btn uagb-btn-mobile__default-btn uagb-block-ba1e67d1\"><div class=\"uagb-buttons__wrap uagb-buttons-layout-wrap \">\n<div class=\"wp-block-uagb-buttons-child uagb-buttons__outer-wrap uagb-block-23cfb623 wp-block-button\"><div class=\"uagb-button__wrapper\"><a class=\"uagb-buttons-repeater wp-block-button__link\" aria-label=\"\" href=\"https:\/\/v2charge.atlassian.net\/servicedesk\/customer\/portal\/3\" rel=\"follow noopener\" target=\"_blank\" role=\"button\"><div class=\"uagb-button__link\">Contatta il Supporto Tecnico<\/div><\/a><\/div><\/div>\n<\/div><\/div>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Codici di errore di connessione e soluzioni Se durante l&#8217;attivazione del controllo dinamico della potenza nel caricatore Trydan o Trydan Pro si verifica un errore, sul display del caricatore apparir\u00e0 un codice corrispondente. Le soluzioni agli errori riportate di seguito si applicano alla versione 1.6.18 o superiore. Se disponi di una versione precedente, aggiorna il &#8230; <a title=\"Codici di errore di connessione e soluzioni\" class=\"read-more\" href=\"https:\/\/v2charge.com\/it\/supporto\/controllo-potenza\/dinamico\/risoluzione-errori\/\" aria-label=\"Per saperne di pi\u00f9 su Codici di errore di connessione e soluzioni\">Leggi tutto<\/a><\/p>\n","protected":false},"author":400,"featured_media":170351,"parent":125466,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_eb_attr":"","content-type":"","_uag_custom_page_level_css":"","footnotes":""},"class_list":["post-187050","page","type-page","status-publish","has-post-thumbnail"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.3.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Codici di errore di connessione e soluzioni - Trydan<\/title>\n<meta name=\"description\" content=\"Compare un errore di connessione sul display di Trydan? Scopri il significato dell&#039;errore e la soluzione | Area di Supporto\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/v2charge.com\/it\/supporto\/controllo-potenza\/dinamico\/risoluzione-errori\/\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Codici di errore di connessione e soluzioni - Trydan\" \/>\n<meta property=\"og:description\" content=\"Compare un errore di connessione sul display di Trydan? Scopri il significato dell&#039;errore e la soluzione | Area di Supporto\" \/>\n<meta property=\"og:url\" content=\"https:\/\/v2charge.com\/it\/supporto\/controllo-potenza\/dinamico\/risoluzione-errori\/\" \/>\n<meta property=\"og:site_name\" content=\"V2C\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/V2C.Charge\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-13T14:46:31+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"675\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@V2C_Charge\" \/>\n<meta name=\"twitter:label1\" content=\"Tempo di lettura stimato\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 minuti\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/v2charge.com\/it\/supporto\/controllo-potenza\/dinamico\/risoluzione-errori\/\",\"url\":\"https:\/\/v2charge.com\/it\/supporto\/controllo-potenza\/dinamico\/risoluzione-errori\/\",\"name\":\"Codici di errore di connessione e soluzioni - Trydan\",\"isPartOf\":{\"@id\":\"https:\/\/v2charge.com\/it\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/v2charge.com\/it\/supporto\/controllo-potenza\/dinamico\/risoluzione-errori\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/v2charge.com\/it\/supporto\/controllo-potenza\/dinamico\/risoluzione-errori\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg\",\"datePublished\":\"2024-11-07T11:52:13+00:00\",\"dateModified\":\"2026-01-13T14:46:31+00:00\",\"description\":\"Compare un errore di connessione sul display di Trydan? Scopri il significato dell'errore e la soluzione | Area di Supporto\",\"breadcrumb\":{\"@id\":\"https:\/\/v2charge.com\/it\/supporto\/controllo-potenza\/dinamico\/risoluzione-errori\/#breadcrumb\"},\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/v2charge.com\/it\/supporto\/controllo-potenza\/dinamico\/risoluzione-errori\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\/\/v2charge.com\/it\/supporto\/controllo-potenza\/dinamico\/risoluzione-errori\/#primaryimage\",\"url\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg\",\"contentUrl\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg\",\"width\":1200,\"height\":675,\"caption\":\"V2C Electric Chargers\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/v2charge.com\/it\/supporto\/controllo-potenza\/dinamico\/risoluzione-errori\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"V2C\",\"item\":\"https:\/\/v2charge.com\/it\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Area di supporto\",\"item\":\"https:\/\/v2charge.com\/it\/supporto\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Controllo di potenza\",\"item\":\"https:\/\/v2charge.com\/it\/supporto\/controllo-potenza\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Dinamico\",\"item\":\"https:\/\/v2charge.com\/it\/supporto\/controllo-potenza\/dinamico\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"Codici di errore di connessione e soluzioni\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/v2charge.com\/it\/#website\",\"url\":\"https:\/\/v2charge.com\/it\/\",\"name\":\"V2C\",\"description\":\"#CargandoElMa\u00f1ana\",\"publisher\":{\"@id\":\"https:\/\/v2charge.com\/it\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/v2charge.com\/it\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"it-IT\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/v2charge.com\/it\/#organization\",\"name\":\"V2C\",\"url\":\"https:\/\/v2charge.com\/it\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\/\/v2charge.com\/it\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png\",\"contentUrl\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png\",\"width\":984,\"height\":431,\"caption\":\"V2C\"},\"image\":{\"@id\":\"https:\/\/v2charge.com\/it\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/V2C.Charge\",\"https:\/\/x.com\/V2C_Charge\",\"https:\/\/www.instagram.com\/v2c.charge\/\",\"https:\/\/www.youtube.com\/@V2C\",\"https:\/\/www.linkedin.com\/company\/v2c-chargers\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Codici di errore di connessione e soluzioni - Trydan","description":"Compare un errore di connessione sul display di Trydan? Scopri il significato dell'errore e la soluzione | Area di Supporto","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/v2charge.com\/it\/supporto\/controllo-potenza\/dinamico\/risoluzione-errori\/","og_locale":"it_IT","og_type":"article","og_title":"Codici di errore di connessione e soluzioni - Trydan","og_description":"Compare un errore di connessione sul display di Trydan? Scopri il significato dell'errore e la soluzione | Area di Supporto","og_url":"https:\/\/v2charge.com\/it\/supporto\/controllo-potenza\/dinamico\/risoluzione-errori\/","og_site_name":"V2C","article_publisher":"https:\/\/www.facebook.com\/V2C.Charge","article_modified_time":"2026-01-13T14:46:31+00:00","og_image":[{"width":1200,"height":675,"url":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@V2C_Charge","twitter_misc":{"Tempo di lettura stimato":"6 minuti"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/v2charge.com\/it\/supporto\/controllo-potenza\/dinamico\/risoluzione-errori\/","url":"https:\/\/v2charge.com\/it\/supporto\/controllo-potenza\/dinamico\/risoluzione-errori\/","name":"Codici di errore di connessione e soluzioni - Trydan","isPartOf":{"@id":"https:\/\/v2charge.com\/it\/#website"},"primaryImageOfPage":{"@id":"https:\/\/v2charge.com\/it\/supporto\/controllo-potenza\/dinamico\/risoluzione-errori\/#primaryimage"},"image":{"@id":"https:\/\/v2charge.com\/it\/supporto\/controllo-potenza\/dinamico\/risoluzione-errori\/#primaryimage"},"thumbnailUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","datePublished":"2024-11-07T11:52:13+00:00","dateModified":"2026-01-13T14:46:31+00:00","description":"Compare un errore di connessione sul display di Trydan? Scopri il significato dell'errore e la soluzione | Area di Supporto","breadcrumb":{"@id":"https:\/\/v2charge.com\/it\/supporto\/controllo-potenza\/dinamico\/risoluzione-errori\/#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/v2charge.com\/it\/supporto\/controllo-potenza\/dinamico\/risoluzione-errori\/"]}]},{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/v2charge.com\/it\/supporto\/controllo-potenza\/dinamico\/risoluzione-errori\/#primaryimage","url":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","contentUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","width":1200,"height":675,"caption":"V2C Electric Chargers"},{"@type":"BreadcrumbList","@id":"https:\/\/v2charge.com\/it\/supporto\/controllo-potenza\/dinamico\/risoluzione-errori\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"V2C","item":"https:\/\/v2charge.com\/it\/"},{"@type":"ListItem","position":2,"name":"Area di supporto","item":"https:\/\/v2charge.com\/it\/supporto\/"},{"@type":"ListItem","position":3,"name":"Controllo di potenza","item":"https:\/\/v2charge.com\/it\/supporto\/controllo-potenza\/"},{"@type":"ListItem","position":4,"name":"Dinamico","item":"https:\/\/v2charge.com\/it\/supporto\/controllo-potenza\/dinamico\/"},{"@type":"ListItem","position":5,"name":"Codici di errore di connessione e soluzioni"}]},{"@type":"WebSite","@id":"https:\/\/v2charge.com\/it\/#website","url":"https:\/\/v2charge.com\/it\/","name":"V2C","description":"#CargandoElMa\u00f1ana","publisher":{"@id":"https:\/\/v2charge.com\/it\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/v2charge.com\/it\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"it-IT"},{"@type":"Organization","@id":"https:\/\/v2charge.com\/it\/#organization","name":"V2C","url":"https:\/\/v2charge.com\/it\/","logo":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/v2charge.com\/it\/#\/schema\/logo\/image\/","url":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png","contentUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png","width":984,"height":431,"caption":"V2C"},"image":{"@id":"https:\/\/v2charge.com\/it\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/V2C.Charge","https:\/\/x.com\/V2C_Charge","https:\/\/www.instagram.com\/v2c.charge\/","https:\/\/www.youtube.com\/@V2C","https:\/\/www.linkedin.com\/company\/v2c-chargers\/"]}]}},"uagb_featured_image_src":{"full":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"thumbnail":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-150x150.jpg",150,150,true],"medium":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-300x169.jpg",300,169,true],"medium_large":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-768x432.jpg",768,432,true],"large":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-1024x576.jpg",1024,576,true],"gs-tiny":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",50,28,false],"xl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxxxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxxxxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"1536x1536":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"2048x2048":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false]},"uagb_author_info":{"display_name":"V2C","author_link":"https:\/\/v2charge.com\/it\/author\/marketing\/"},"uagb_comment_info":0,"uagb_excerpt":"Codici di errore di connessione e soluzioni Se durante l&#8217;attivazione del controllo dinamico della potenza nel caricatore Trydan o Trydan Pro si verifica un errore, sul display del caricatore apparir\u00e0 un codice corrispondente. Le soluzioni agli errori riportate di seguito si applicano alla versione 1.6.18 o superiore. Se disponi di una versione precedente, aggiorna il&hellip;","_links":{"self":[{"href":"https:\/\/v2charge.com\/it\/wp-json\/wp\/v2\/pages\/187050","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/v2charge.com\/it\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/v2charge.com\/it\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/v2charge.com\/it\/wp-json\/wp\/v2\/users\/400"}],"replies":[{"embeddable":true,"href":"https:\/\/v2charge.com\/it\/wp-json\/wp\/v2\/comments?post=187050"}],"version-history":[{"count":5,"href":"https:\/\/v2charge.com\/it\/wp-json\/wp\/v2\/pages\/187050\/revisions"}],"predecessor-version":[{"id":295431,"href":"https:\/\/v2charge.com\/it\/wp-json\/wp\/v2\/pages\/187050\/revisions\/295431"}],"up":[{"embeddable":true,"href":"https:\/\/v2charge.com\/it\/wp-json\/wp\/v2\/pages\/125466"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/v2charge.com\/it\/wp-json\/wp\/v2\/media\/170351"}],"wp:attachment":[{"href":"https:\/\/v2charge.com\/it\/wp-json\/wp\/v2\/media?parent=187050"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}