{"id":376128,"date":"2026-07-15T12:58:07","date_gmt":"2026-07-15T12:58:07","guid":{"rendered":""},"modified":"2026-07-15T12:58:07","modified_gmt":"2026-07-15T12:58:07","slug":"sostituzione-scheda-controllo","status":"publish","type":"page","link":"https:\/\/v2charge.com\/it\/supporto\/pole-pro\/sostituzione-scheda-controllo\/","title":{"rendered":"Sostituzione della scheda di controllo: da POLE V1 a POLE V2"},"content":{"rendered":"\n<div class=\"wp-block-uagb-container uagb-block-pv1a1001 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><div class=\"yoast-breadcrumbs\"><span><span><a href=\"https:\/\/v2charge.com\/it\/\">V2C<\/a><\/span> \u00bb <span><a href=\"https:\/\/v2charge.com\/it\/supporto\/\">Area di supporto<\/a><\/span> \u00bb <span><a href=\"https:\/\/v2charge.com\/it\/supporto\/pole-pro\/\">Supporto Pole<\/a><\/span> \u00bb <span class=\"breadcrumb_last\" aria-current=\"page\">Sostituzione della scheda di controllo<\/span><\/span><\/div>\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-pv1a1002\"><h1 class=\"uagb-heading-text\">Sostituzione della scheda di controllo: da POLE V1 a POLE V2<\/h1><\/div>\n\n<p class=\"wp-block-paragraph\">Se hai bisogno di sostituire la scheda di controllo di un caricatore <strong>Pole Pro<\/strong> e la nuova scheda ricevuta \u00e8 di una versione diversa da quella installata, dovrai tenere in considerazione la corrispondenza tra i connettori delle due versioni. La <strong>scheda verde corrisponde a POLE V1<\/strong> e la <strong>scheda bianca a POLE V2<\/strong>. Di seguito, troverai l&#8217;equivalenza esatta di ciascun pin, sia per il connettore sinistro che per quello destro, e lo schema completo di connessione di ciascuna versione.<\/p><\/div><\/div>\n\n\n<style>.uagb-block-pv1a1003{max-width:700px !important;margin-left:auto !important;margin-right:auto !important;}<\/style>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-pv1a1003 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><p class=\"wp-block-paragraph\">&#x26a0;&#xfe0f; <strong>Importante:<\/strong> sostituendo la piastra, sar\u00e0 necessario aggiungere anche l&#8217;installazione del sensore di perdite.<\/p><\/div><\/div>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n&#8220;`html\n<style>\n.tabla-conectores-pole{width:100%;overflow-x:auto;margin:16px 0;border-radius:10px;box-shadow:0 2px 8px rgba(0,0,0,0.07);}\n.tabla-conectores-pole table{width:100%;border-collapse:separate;border-spacing:0;font-family:Arial,Helvetica,sans-serif;font-size:14px;color:#222;background:#fff;border-radius:10px;overflow:hidden;}\n.tabla-conectores-pole caption{text-align:left;font-weight:700;padding:10px 14px;background:var(--contrast);color:var(--base-2);caption-side:top;}\n.tabla-conectores-pole td{padding:9px 14px;border-bottom:1px solid #ececec;vertical-align:middle;}\n.tabla-conectores-pole tr.grupo-conector td{background:#eef2f5;font-weight:700;color:#333;padding:8px 14px;border-bottom:1px solid #dfe3e6;}\n.tabla-conectores-pole tr:not(.grupo-conector):nth-child(even) td{background:#f7f7f8;}\n.tabla-conectores-pole tr:last-child td{border-bottom:none;}\n.tabla-conectores-pole td:first-child{font-weight:700;width:36px;text-align:center;color:#666;}\n.tabla-conectores-pole tr.grupo-conector td:first-child{width:auto;text-align:left;color:#333;}\n@media (max-width:600px){.tabla-conectores-pole table{font-size:13px;}.tabla-conectores-pole td{padding:7px 10px;}}\n.uagb-block-pv1a2010>.uagb-container-inner-blocks-wrap,\n.uagb-block-pv1a3010>.uagb-container-inner-blocks-wrap{align-items:stretch;}\n.uagb-block-pv1a2011,.uagb-block-pv1a2021,\n.uagb-block-pv1a3011,.uagb-block-pv1a3021{display:flex;flex-direction:column;}\n.tabla-conectores-pole{flex:1 1 auto;display:flex;flex-direction:column;}\n.tabla-conectores-pole table{flex:1 1 auto;}\n<\/style>\n&#8220;`\n\n\n<div class=\"wp-block-uagb-container uagb-block-pv1a2001 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><div class=\"wp-block-uagb-advanced-heading uagb-block-pv1a2002\"><h2 class=\"uagb-heading-text\">Connettore sinistro<\/h2><\/div>\n\n<p class=\"wp-block-paragraph\">Nel <strong>POLE V1<\/strong> il connettore sinistro si divide in due connettori indipendenti (<strong>CN10<\/strong> e <strong>CN6<\/strong>). Nel <strong>POLE V2<\/strong> entrambi si integrano in un unico connettore a 16 pin (<strong>J1<\/strong>).<\/p><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-pv1a2010 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-pv1a2011\"><div class=\"wp-block-uagb-advanced-heading uagb-block-pv1a2012\"><h2 class=\"uagb-heading-text\">Connettori POLE V1 \u2014 Piastra verde<\/h2><\/div>\n\n<div class=\"tabla-conectores-pole\">\n<table>\n<caption>Connettore sinistro<\/caption>\n<tbody>\n<tr class=\"grupo-conector\"><td colspan=\"2\">CN10<\/td><\/tr>\n<tr><td>1<\/td><td>GND<\/td><\/tr>\n<tr><td>2<\/td><td>FUGA_SIN_1<\/td><\/tr>\n<tr><td>3<\/td><td>FUGA_SIN_2<\/td><\/tr>\n<tr><td>4<\/td><td>+12V<\/td><\/tr>\n<tr><td>5<\/td><td>LED_R_CON_SIN<\/td><\/tr>\n<tr><td>6<\/td><td>LED_V_CON_SIN<\/td><\/tr>\n<tr><td>7<\/td><td>LED_A_CON_SIN<\/td><\/tr>\n<tr><td>8<\/td><td>RS485_A<\/td><\/tr>\n<tr><td>9<\/td><td>RS485_B<\/td><\/tr>\n<tr class=\"grupo-conector\"><td colspan=\"2\">CN6<\/td><\/tr>\n<tr><td>1<\/td><td>CP_SIN<\/td><\/tr>\n<tr><td>2<\/td><td>PP_SIN<\/td><\/tr>\n<tr><td>3<\/td><td>BLOCCO_SIN_1<\/td><\/tr>\n<tr><td>4<\/td><td>BLOCCO_SIN_2<\/td><\/tr>\n<tr><td>5<\/td><td>GND<\/td><\/tr>\n<tr><td>6<\/td><td>+5V<\/td><\/tr>\n<tr><td>7<\/td><td>&#8211;<\/td><\/tr>\n<tr><td>8<\/td><td>GND<\/td><\/tr>\n<tr><td>9<\/td><td>+12V<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-pv1a2021\"><div class=\"wp-block-uagb-advanced-heading uagb-block-pv1a2022\"><h2 class=\"uagb-heading-text\">Connettori POLE V2 \u2014 Piastra bianca<\/h2><\/div>\n\n<div class=\"tabla-conectores-pole\">\n<table>\n<caption>Connettore sinistro<\/caption>\n<tbody>\n<tr class=\"grupo-conector\"><td colspan=\"2\">J1<\/td><\/tr>\n<tr><td>1<\/td><td>CP_SIN<\/td><\/tr>\n<tr><td>2<\/td><td>PP_SIN<\/td><\/tr>\n<tr><td>3<\/td><td>BLOCCO_SIN_1<\/td><\/tr>\n<tr><td>4<\/td><td>BLOCCO_SIN_2<\/td><\/tr>\n<tr><td>5<\/td><td>SENSORE_BLOCCO<\/td><\/tr>\n<tr><td>6<\/td><td>RS485_A<\/td><\/tr>\n<tr><td>7<\/td><td>DISPARIT\u00c0_PROTEZIONE<\/td><\/tr>\n<tr><td>8<\/td><td>GND<\/td><\/tr>\n<tr><td>9<\/td><td>+12V<\/td><\/tr>\n<tr><td>10<\/td><td>LED_R_CON_SIN<\/td><\/tr>\n<tr><td>11<\/td><td>LED_V_CON_SIN<\/td><\/tr>\n<tr><td>12<\/td><td>LED_A_CON_SIN<\/td><\/tr>\n<tr><td>13<\/td><td>GND<\/td><\/tr>\n<tr><td>14<\/td><td>RS485_B<\/td><\/tr>\n<tr><td>15<\/td><td>DETEZIONE_SALDATURA<\/td><\/tr>\n<tr><td>16<\/td><td>GND<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div><\/div>\n<\/div><\/div>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-pv1a3001 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><div class=\"wp-block-uagb-advanced-heading uagb-block-pv1a3002\"><h2 class=\"uagb-heading-text\">Connettore destro<\/h2><\/div>\n\n<p class=\"wp-block-paragraph\">Nel <strong>POLE V1<\/strong> il connettore destro si divide anche in due connettori (<strong>CN8<\/strong> e <strong>CN5<\/strong>), che nel <strong>POLE V2<\/strong> si integrano nel connettore <strong>J2<\/strong>.<\/p><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-pv1a3010 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-pv1a3011\"><div class=\"wp-block-uagb-advanced-heading uagb-block-pv1a3012\"><h2 class=\"uagb-heading-text\">Connettori POLE V1 \u2014 Piastra verde<\/h2><\/div>\n\n<div class=\"tabla-conectores-pole\">\n<table>\n<caption>Connettore destro<\/caption>\n<tbody>\n<tr class=\"grupo-conector\"><td colspan=\"2\">CN8<\/td><\/tr>\n<tr><td>1<\/td><td>GND<\/td><\/tr>\n<tr><td>2<\/td><td>FUGA_DER_1<\/td><\/tr>\n<tr><td>3<\/td><td>FUGA_DER_2<\/td><\/tr>\n<tr><td>4<\/td><td>+12V<\/td><\/tr>\n<tr><td>5<\/td><td>LED_R_CON_DER<\/td><\/tr>\n<tr><td>6<\/td><td>LED_V_CON_DER<\/td><\/tr>\n<tr><td>7<\/td><td>LED_A_CON_DER<\/td><\/tr>\n<tr><td>8<\/td><td>&#8211;<\/td><\/tr>\n<tr><td>9<\/td><td>&#8211;<\/td><\/tr>\n<tr class=\"grupo-conector\"><td colspan=\"2\">CN5<\/td><\/tr>\n<tr><td>1<\/td><td>CP_DER<\/td><\/tr>\n<tr><td>2<\/td><td>PP_DER<\/td><\/tr>\n<tr><td>3<\/td><td>BLOQUEO_DER_1<\/td><\/tr>\n<tr><td>4<\/td><td>BLOQUEO_DER_2<\/td><\/tr>\n<tr><td>5<\/td><td>GND<\/td><\/tr>\n<tr><td>6<\/td><td>+5V<\/td><\/tr>\n<tr><td>7<\/td><td>&#8211;<\/td><\/tr>\n<tr><td>8<\/td><td>GND<\/td><\/tr>\n<tr><td>9<\/td><td>+12V<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-pv1a3021\"><div class=\"wp-block-uagb-advanced-heading uagb-block-pv1a3022\"><h2 class=\"uagb-heading-text\">Connettori POLE V2 \u2014 Piastra bianca<\/h2><\/div>\n\n<div class=\"tabla-conectores-pole\">\n<table>\n<caption>Connettore destro<\/caption>\n<tbody>\n<tr class=\"grupo-conector\"><td colspan=\"2\">J2<\/td><\/tr>\n<tr><td>1<\/td><td>CP_DER<\/td><\/tr>\n<tr><td>2<\/td><td>PP_DER<\/td><\/tr>\n<tr><td>3<\/td><td>BLOCCO_DER_1<\/td><\/tr>\n<tr><td>4<\/td><td>BLOCCO_DER_2<\/td><\/tr>\n<tr><td>5<\/td><td>SENSORE_BLOCCO<\/td><\/tr>\n<tr><td>6<\/td><td>GND<\/td><\/tr>\n<tr><td>7<\/td><td>DISPARIT\u00c0_PROTEZIONE<\/td><\/tr>\n<tr><td>8<\/td><td>GND<\/td><\/tr>\n<tr><td>9<\/td><td>+12V<\/td><\/tr>\n<tr><td>10<\/td><td>LED_R_CON_DER<\/td><\/tr>\n<tr><td>11<\/td><td>LED_V_CON_DER<\/td><\/tr>\n<tr><td>12<\/td><td>LED_A_CON_DER<\/td><\/tr>\n<tr><td>13<\/td><td>GND<\/td><\/tr>\n<tr><td>14<\/td><td>FALLIMENTO_ENERGIA<\/td><\/tr>\n<tr><td>15<\/td><td>DETEZIONE_SALDATURA<\/td><\/tr>\n<tr><td>16<\/td><td>GND<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div><\/div>\n<\/div><\/div>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-pv1a4001 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><div class=\"wp-block-uagb-advanced-heading uagb-block-pv1a4002\"><h2 class=\"uagb-heading-text\">Schema completo di connessione<\/h2><\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-pv1a4010 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><div class=\"wp-block-uagb-advanced-heading uagb-block-pv1a4011\"><h2 class=\"uagb-heading-text\">POLE V1<\/h2><\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1400\" height=\"990\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2026\/07\/pole-esquema-v1.jpg\" alt=\"Esquema de conexi\u00f3n de la placa de control POLE V1\" class=\"wp-image-375945\" srcset=\"https:\/\/v2charge.com\/wp-content\/uploads\/2026\/07\/pole-esquema-v1.jpg 1400w, https:\/\/v2charge.com\/wp-content\/uploads\/2026\/07\/pole-esquema-v1-300x212.jpg 300w, https:\/\/v2charge.com\/wp-content\/uploads\/2026\/07\/pole-esquema-v1-1024x724.jpg 1024w, https:\/\/v2charge.com\/wp-content\/uploads\/2026\/07\/pole-esquema-v1-768x543.jpg 768w, https:\/\/v2charge.com\/wp-content\/uploads\/2026\/07\/pole-esquema-v1-50x35.jpg 50w\" sizes=\"auto, (max-width: 1400px) 100vw, 1400px\" \/><\/figure>\n<\/div>\n\n<p class=\"has-text-align-center has-small-font-size wp-block-paragraph\">I cavi del CN19 e CN18 si collegano ai contattori.<\/p><\/div><\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-pv1a4020 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><div class=\"wp-block-uagb-advanced-heading uagb-block-pv1a4021\"><h2 class=\"uagb-heading-text\">POLE V2<\/h2><\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1400\" height=\"990\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2026\/07\/pole-esquema-v2.jpg\" alt=\"Esquema de conexi\u00f3n de la placa de control POLE V2\" class=\"wp-image-375968\" srcset=\"https:\/\/v2charge.com\/wp-content\/uploads\/2026\/07\/pole-esquema-v2.jpg 1400w, https:\/\/v2charge.com\/wp-content\/uploads\/2026\/07\/pole-esquema-v2-300x212.jpg 300w, https:\/\/v2charge.com\/wp-content\/uploads\/2026\/07\/pole-esquema-v2-1024x724.jpg 1024w, https:\/\/v2charge.com\/wp-content\/uploads\/2026\/07\/pole-esquema-v2-768x543.jpg 768w, https:\/\/v2charge.com\/wp-content\/uploads\/2026\/07\/pole-esquema-v2-50x35.jpg 50w\" sizes=\"auto, (max-width: 1400px) 100vw, 1400px\" \/><\/figure>\n<\/div>\n\n<p class=\"has-text-align-center has-small-font-size wp-block-paragraph\">I cavi del CN14 e CN16 si collegano ai contattori.<\/p><\/div><\/div>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-c6f38013 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><div class=\"wp-block-uagb-advanced-heading uagb-block-6963d70c\"><h2 class=\"uagb-heading-text\"><strong>Hai bisogno di supporto tecnico?<\/strong><\/h2><\/div>\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-408243eb\"><p class=\"uagb-heading-text\">Risolvi la tua incidenza immediatamente tramite la nostra Chat con IA. Se non viene risolta, genera una richiesta nel Centro di Supporto Tecnico e ti contatteremo il prima possibile per offrirti la migliore soluzione.<\/p><\/div>\n\n<div class=\"uagb-block-12e3cf1c uagb-infobox__content-wrap  uagb-infobox-icon-left uagb-infobox-left uagb-infobox-image-valign-top  wp-block-uagb-info-box--has-margin\"><div class=\"uagb-infobox-margin-wrapper\"><div class=\"uagb-ifb-image-content\"><img decoding=\"async\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2026\/01\/support-ai-chatbot.png\" alt=\"\" width=\"20\" height=\"19\" loading=\"lazy\"\/><\/div><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><\/div><div class=\"uagb-ifb-button-wrapper wp-block-button\"><a href=\"https:\/\/v2charge.com\/it\/v2c-support-web\/\" class=\"uagb-infobox-cta-link wp-block-button__link\" target=\"_blank\" rel=\"noopener noreferrer\" onclick=\"return true;\"><span class=\"uagb-inline-editing\">Chiedi al nostro Chat con IA<\/span><\/a><\/div><\/div><\/div><\/div>\n\n\n<div class=\"wp-block-uagb-buttons uagb-buttons__outer-wrap uagb-btn__default-btn uagb-btn-tablet__default-btn uagb-btn-mobile__default-btn uagb-block-ba1e67d1\"><div class=\"uagb-buttons__wrap uagb-buttons-layout-wrap \"><div class=\"wp-block-uagb-buttons-child uagb-buttons__outer-wrap uagb-block-23cfb623 wp-block-button\"><div class=\"uagb-button__wrapper\"><a class=\"uagb-buttons-repeater wp-block-button__link\" aria-label=\"\" href=\"https:\/\/v2charge.atlassian.net\/servicedesk\/customer\/portal\/3\" rel=\"follow noopener\" target=\"_blank\" role=\"button\"><div class=\"uagb-button__link\">Contatta il Supporto Tecnico<\/div><\/a><\/div><\/div><\/div><\/div>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Sostituzione della scheda di controllo: da POLE V1 a POLE V2 Se hai bisogno di sostituire la scheda di controllo di un caricatore Pole Pro e la nuova scheda ricevuta \u00e8 di una versione diversa da quella installata, dovrai tenere in considerazione la corrispondenza tra i connettori delle due versioni. La scheda verde corrisponde a &#8230; <a title=\"Sostituzione della scheda di controllo: da POLE V1 a POLE V2\" class=\"read-more\" href=\"https:\/\/v2charge.com\/it\/supporto\/pole-pro\/sostituzione-scheda-controllo\/\" aria-label=\"Per saperne di pi\u00f9 su Sostituzione della scheda di controllo: da POLE V1 a POLE V2\">Leggi tutto<\/a><\/p>\n","protected":false},"author":400,"featured_media":0,"parent":75374,"menu_order":0,"comment_status":"open","ping_status":"open","template":"","meta":{"_eb_attr":"","content-type":"","_uag_custom_page_level_css":"","footnotes":""},"class_list":["post-376128","page","type-page","status-publish"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Sostituzione della scheda di controllo - Pole Pro<\/title>\n<meta name=\"description\" content=\"Scopri come sostituire la scheda di controllo di Pole Pro | Come sostituire da POLE V1 a POLE V2 - Area di Supporto V2C\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/v2charge.com\/it\/supporto\/pole-pro\/sostituzione-scheda-controllo\/\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Sostituzione della scheda di controllo - Pole Pro\" \/>\n<meta property=\"og:description\" content=\"Scopri come sostituire la scheda di controllo di Pole Pro | Come sostituire da POLE V1 a POLE V2 - Area di Supporto V2C\" \/>\n<meta property=\"og:url\" content=\"https:\/\/v2charge.com\/it\/supporto\/pole-pro\/sostituzione-scheda-controllo\/\" \/>\n<meta property=\"og:site_name\" content=\"V2C\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/V2C.Charge\" \/>\n<meta property=\"og:image\" content=\"https:\/\/v2charge.com\/wp-content\/uploads\/2026\/07\/pole-esquema-v1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1400\" \/>\n\t<meta property=\"og:image:height\" content=\"990\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@V2C_Charge\" \/>\n<meta name=\"twitter:label1\" content=\"Tempo di lettura stimato\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minuti\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/v2charge.com\\\/it\\\/supporto\\\/pole-pro\\\/sostituzione-scheda-controllo\\\/\",\"url\":\"https:\\\/\\\/v2charge.com\\\/it\\\/supporto\\\/pole-pro\\\/sostituzione-scheda-controllo\\\/\",\"name\":\"Sostituzione della scheda di controllo - Pole Pro\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/v2charge.com\\\/it\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/v2charge.com\\\/it\\\/supporto\\\/pole-pro\\\/sostituzione-scheda-controllo\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/v2charge.com\\\/it\\\/supporto\\\/pole-pro\\\/sostituzione-scheda-controllo\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/v2charge.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/pole-esquema-v1.jpg\",\"datePublished\":\"2026-07-15T12:58:07+00:00\",\"description\":\"Scopri come sostituire la scheda di controllo di Pole Pro | Come sostituire da POLE V1 a POLE V2 - Area di Supporto V2C\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/v2charge.com\\\/it\\\/supporto\\\/pole-pro\\\/sostituzione-scheda-controllo\\\/#breadcrumb\"},\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/v2charge.com\\\/it\\\/supporto\\\/pole-pro\\\/sostituzione-scheda-controllo\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/v2charge.com\\\/it\\\/supporto\\\/pole-pro\\\/sostituzione-scheda-controllo\\\/#primaryimage\",\"url\":\"https:\\\/\\\/v2charge.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/pole-esquema-v1.jpg\",\"contentUrl\":\"https:\\\/\\\/v2charge.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/pole-esquema-v1.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/v2charge.com\\\/it\\\/supporto\\\/pole-pro\\\/sostituzione-scheda-controllo\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"V2C\",\"item\":\"https:\\\/\\\/v2charge.com\\\/it\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Area di supporto\",\"item\":\"https:\\\/\\\/v2charge.com\\\/it\\\/supporto\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Supporto Pole\",\"item\":\"https:\\\/\\\/v2charge.com\\\/it\\\/supporto\\\/pole-pro\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Sostituzione della scheda di controllo\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/v2charge.com\\\/it\\\/#website\",\"url\":\"https:\\\/\\\/v2charge.com\\\/it\\\/\",\"name\":\"V2C\",\"description\":\"#CargandoElMa\u00f1ana\",\"publisher\":{\"@id\":\"https:\\\/\\\/v2charge.com\\\/it\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/v2charge.com\\\/it\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"it-IT\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/v2charge.com\\\/it\\\/#organization\",\"name\":\"V2C\",\"url\":\"https:\\\/\\\/v2charge.com\\\/it\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/v2charge.com\\\/it\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/v2charge.com\\\/wp-content\\\/uploads\\\/2024\\\/11\\\/cropped-v2c-charge-logo-menu.png\",\"contentUrl\":\"https:\\\/\\\/v2charge.com\\\/wp-content\\\/uploads\\\/2024\\\/11\\\/cropped-v2c-charge-logo-menu.png\",\"width\":984,\"height\":431,\"caption\":\"V2C\"},\"image\":{\"@id\":\"https:\\\/\\\/v2charge.com\\\/it\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/V2C.Charge\",\"https:\\\/\\\/x.com\\\/V2C_Charge\",\"https:\\\/\\\/www.instagram.com\\\/v2c.charge\\\/\",\"https:\\\/\\\/www.youtube.com\\\/@V2C\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/v2c-chargers\\\/\"],\"contactPoint\":[{\"@type\":\"ContactPoint\",\"contactType\":\"customer support\",\"telephone\":\"+34960654554\",\"email\":\"info@v2charge.com\",\"availableLanguage\":[\"Spanish\",\"English\",\"Portuguese\",\"French\"]},{\"@type\":\"ContactPoint\",\"contactType\":\"sales\",\"telephone\":\"+34960654554\",\"email\":\"info@v2charge.com\",\"availableLanguage\":[\"Spanish\",\"English\"]}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Sostituzione della scheda di controllo - Pole Pro","description":"Scopri come sostituire la scheda di controllo di Pole Pro | Come sostituire da POLE V1 a POLE V2 - Area di Supporto V2C","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/v2charge.com\/it\/supporto\/pole-pro\/sostituzione-scheda-controllo\/","og_locale":"it_IT","og_type":"article","og_title":"Sostituzione della scheda di controllo - Pole Pro","og_description":"Scopri come sostituire la scheda di controllo di Pole Pro | Come sostituire da POLE V1 a POLE V2 - Area di Supporto V2C","og_url":"https:\/\/v2charge.com\/it\/supporto\/pole-pro\/sostituzione-scheda-controllo\/","og_site_name":"V2C","article_publisher":"https:\/\/www.facebook.com\/V2C.Charge","og_image":[{"width":1400,"height":990,"url":"https:\/\/v2charge.com\/wp-content\/uploads\/2026\/07\/pole-esquema-v1.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@V2C_Charge","twitter_misc":{"Tempo di lettura stimato":"2 minuti"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/v2charge.com\/it\/supporto\/pole-pro\/sostituzione-scheda-controllo\/","url":"https:\/\/v2charge.com\/it\/supporto\/pole-pro\/sostituzione-scheda-controllo\/","name":"Sostituzione della scheda di controllo - Pole Pro","isPartOf":{"@id":"https:\/\/v2charge.com\/it\/#website"},"primaryImageOfPage":{"@id":"https:\/\/v2charge.com\/it\/supporto\/pole-pro\/sostituzione-scheda-controllo\/#primaryimage"},"image":{"@id":"https:\/\/v2charge.com\/it\/supporto\/pole-pro\/sostituzione-scheda-controllo\/#primaryimage"},"thumbnailUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2026\/07\/pole-esquema-v1.jpg","datePublished":"2026-07-15T12:58:07+00:00","description":"Scopri come sostituire la scheda di controllo di Pole Pro | Come sostituire da POLE V1 a POLE V2 - Area di Supporto V2C","breadcrumb":{"@id":"https:\/\/v2charge.com\/it\/supporto\/pole-pro\/sostituzione-scheda-controllo\/#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/v2charge.com\/it\/supporto\/pole-pro\/sostituzione-scheda-controllo\/"]}]},{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/v2charge.com\/it\/supporto\/pole-pro\/sostituzione-scheda-controllo\/#primaryimage","url":"https:\/\/v2charge.com\/wp-content\/uploads\/2026\/07\/pole-esquema-v1.jpg","contentUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2026\/07\/pole-esquema-v1.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/v2charge.com\/it\/supporto\/pole-pro\/sostituzione-scheda-controllo\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"V2C","item":"https:\/\/v2charge.com\/it\/"},{"@type":"ListItem","position":2,"name":"Area di supporto","item":"https:\/\/v2charge.com\/it\/supporto\/"},{"@type":"ListItem","position":3,"name":"Supporto Pole","item":"https:\/\/v2charge.com\/it\/supporto\/pole-pro\/"},{"@type":"ListItem","position":4,"name":"Sostituzione della scheda di controllo"}]},{"@type":"WebSite","@id":"https:\/\/v2charge.com\/it\/#website","url":"https:\/\/v2charge.com\/it\/","name":"V2C","description":"#CargandoElMa\u00f1ana","publisher":{"@id":"https:\/\/v2charge.com\/it\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/v2charge.com\/it\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"it-IT"},{"@type":"Organization","@id":"https:\/\/v2charge.com\/it\/#organization","name":"V2C","url":"https:\/\/v2charge.com\/it\/","logo":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/v2charge.com\/it\/#\/schema\/logo\/image\/","url":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png","contentUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png","width":984,"height":431,"caption":"V2C"},"image":{"@id":"https:\/\/v2charge.com\/it\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/V2C.Charge","https:\/\/x.com\/V2C_Charge","https:\/\/www.instagram.com\/v2c.charge\/","https:\/\/www.youtube.com\/@V2C","https:\/\/www.linkedin.com\/company\/v2c-chargers\/"],"contactPoint":[{"@type":"ContactPoint","contactType":"customer support","telephone":"+34960654554","email":"info@v2charge.com","availableLanguage":["Spanish","English","Portuguese","French"]},{"@type":"ContactPoint","contactType":"sales","telephone":"+34960654554","email":"info@v2charge.com","availableLanguage":["Spanish","English"]}]}]}},"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"gs-tiny":false,"xl":false,"xxl":false,"xxxl":false,"xxxxl":false,"xxxxxl":false,"1536x1536":false,"2048x2048":false},"uagb_author_info":{"display_name":"V2C","author_link":"https:\/\/v2charge.com\/it\/author\/marketing\/"},"uagb_comment_info":0,"uagb_excerpt":"Sostituzione della scheda di controllo: da POLE V1 a POLE V2 Se hai bisogno di sostituire la scheda di controllo di un caricatore Pole Pro e la nuova scheda ricevuta \u00e8 di una versione diversa da quella installata, dovrai tenere in considerazione la corrispondenza tra i connettori delle due versioni. La scheda verde corrisponde a&hellip;","_links":{"self":[{"href":"https:\/\/v2charge.com\/it\/wp-json\/wp\/v2\/pages\/376128","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/v2charge.com\/it\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/v2charge.com\/it\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/v2charge.com\/it\/wp-json\/wp\/v2\/users\/400"}],"replies":[{"embeddable":true,"href":"https:\/\/v2charge.com\/it\/wp-json\/wp\/v2\/comments?post=376128"}],"version-history":[{"count":0,"href":"https:\/\/v2charge.com\/it\/wp-json\/wp\/v2\/pages\/376128\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/v2charge.com\/it\/wp-json\/wp\/v2\/pages\/75374"}],"wp:attachment":[{"href":"https:\/\/v2charge.com\/it\/wp-json\/wp\/v2\/media?parent=376128"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}