{"id":188156,"date":"2024-11-11T14:54:31","date_gmt":"2024-11-11T12:54:31","guid":{"rendered":"https:\/\/v2charge.com\/?page_id=188156"},"modified":"2026-01-13T16:48:24","modified_gmt":"2026-01-13T14:48:24","slug":"solucao-erros","status":"publish","type":"page","link":"https:\/\/v2charge.com\/pt-pt\/suporte\/controlo-potencia\/dinamico\/solucao-erros\/","title":{"rendered":"C\u00f3digos de erros de conex\u00e3o e a sua solu\u00e7\u00e3o"},"content":{"rendered":"\n<div class=\"wp-block-uagb-container uagb-block-9d828d1c alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><div class=\"yoast-breadcrumbs\"><span><span><a href=\"https:\/\/v2charge.com\/pt-pt\/\">V2C<\/a><\/span> \u00bb <span><a href=\"https:\/\/v2charge.com\/pt-pt\/suporte\/\">\u00c1rea de Suporte<\/a><\/span> \u00bb <span><a href=\"https:\/\/v2charge.com\/pt-pt\/suporte\/controlo-potencia\/\">Controlo de pot\u00eancia<\/a><\/span> \u00bb <span><a href=\"https:\/\/v2charge.com\/pt-pt\/suporte\/controlo-potencia\/dinamico\/\">Din\u00e2mico<\/a><\/span> \u00bb <span class=\"breadcrumb_last\" aria-current=\"page\">C\u00f3digos de erros de conex\u00e3o e a sua solu\u00e7\u00e3o<\/span><\/span><\/div>\n\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-be8360a4\"><h1 class=\"uagb-heading-text\">C\u00f3digos de erros de conex\u00e3o e a sua solu\u00e7\u00e3o<\/h1><\/div>\n\n\n\n<p>Se ao ativar o controlo din\u00e2mico de pot\u00eancia no carregador Trydan ou Trydan Pro ocorrer um erro, no display do carregador aparecer\u00e1 um <strong>c\u00f3digo correspondente ao erro.<\/strong><br><br>Las soluciones a los errores establecidos a continuaci\u00f3n corresponden a la <strong>versi\u00f3n 1.6.18 o superiores<\/strong>. En caso de tener una versi\u00f3n inferior, <a href=\"https:\/\/v2charge.com\/pt-pt\/suporte\/trydan\/atualizar-ultima-versao\/\"><strong>actualiza el cargador Trydan<\/strong><\/a> y comprueba de nuevo la siguiente lista.<br>As solu\u00e7\u00f5es para os erros indicados a seguir correspondem \u00e0 <strong>vers\u00e3o 1.6.18 ou superior<\/strong>. Caso tenha uma vers\u00e3o inferior, atualize o carregador Trydan e verifique novamente a lista seguinte.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-f83ba0fb alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-9d537ef2\">\n<div class=\"wp-block-uagb-container uagb-block-1021f2c1\">\n<div class=\"wp-block-uagb-image aligncenter uagb-block-f5b78000 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-center\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png ,https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png 780w, https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png\" alt=\"\" class=\"uag-image-125013\" width=\"50\" height=\"50\" title=\"\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-a8351972\">\n<div class=\"wp-block-uagb-advanced-heading uagb-block-fdcb9def\"><p class=\"uagb-heading-text\"><strong>NOTA IMPORTANTE: <\/strong>estes erros derivam de uma falha de comunica\u00e7\u00e3o entre Trydan e o inversor ou medidor e limitam o carregamento do seu ve\u00edculo ao m\u00ednimo. Alguns podem ocorrer quando a integra\u00e7\u00e3o \u00e9 direta com o inversor, seja atrav\u00e9s de comunica\u00e7\u00e3o Modbus ou RS485.<br><strong>\u00c9 imprescind\u00edvel consultar a solu\u00e7\u00e3o para o erro que aparece no display.<\/strong> Caso o erro persista, contacte o nosso departamento de Suporte T\u00e9cnico e desative o controlo din\u00e2mico de carga para poder carregar na intensidade fixa definida.<\/p><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-separator uagb-block-b0f92113\"><div class=\"wp-block-uagb-separator__inner\" style=\"--my-background-image:\"><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-4d0c1e2a\">\n<div class=\"wp-block-uagb-container uagb-block-195968cb\">\n<table style=\"border:none;\">\n    <tr style=\"border:none;\">\n        <th style=\"border:none;\">ERROR<\/th>\n        <th style=\"border:none;\"><u>00<\/u><\/th>\n        <th style=\"border:none;\"><u>000<\/u><\/th>\n    <\/tr>\n    <tr style=\"border:none;\">\n        <td style=\"border:none;\"><\/td>\n        <td style=\"border:none;\"><center>A<\/center><\/td>\n        <td style=\"border:none;\"><center>B<\/center><\/td>\n    <\/tr>\n<\/table>\n<\/div>\n<\/div>\n\n\n\n<p>Os <strong>dois primeiros d\u00edgitos<\/strong> indicam o medidor ou inversor que estamos a utilizar. \u00c9 importante selecionar o adequado quando se configura o controlo din\u00e2mico de pot\u00eancia e verificar se est\u00e1 correto no caso de erro.<\/p>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-8616beaf\">\n<div class=\"wp-block-uagb-container uagb-block-9f8097ef\">\n<p><strong>Erros &#8211; A<\/strong><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-4816f3c8\">\n<p><strong>00<\/strong>  Medidor Shelly<br><strong>01<\/strong>  V2C ControlBox<br><strong>02<\/strong>  Medidor V2C 1.0<br><strong>03 <\/strong> Conex\u00e3o ao inversor Huawei<br><strong>04 <\/strong> Conex\u00e3o ao inversor Solax<br><strong>05 <\/strong> Conex\u00e3o ao inversor Kostal<strong><br>06 <\/strong> Conex\u00e3o ao inversor Fronius<br><strong>07 <\/strong> Conex\u00e3o ao inversor Ingeteam<br><strong>08 <\/strong> Conex\u00e3o ao medidor Wibeee<br><strong>09 <\/strong> Conex\u00e3o ao medidor Victron<br><strong>10 <\/strong> Conex\u00e3o ao inversor SolarEdge<br><strong>11<\/strong>  Uso de protocolo MQTT<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-8ef7ba8e\">\n<p><strong>12 <\/strong> Conex\u00e3o ao inversor Goodwe<br><strong>13 <\/strong> Conex\u00e3o ao inversor SAJ \/ GreenHeiss<br><strong>14 <\/strong> Conex\u00e3o ao inversor Solis<br><strong>15 <\/strong> Conex\u00e3o ao medidor Chint DDSU666<br><strong>16<\/strong> Conex\u00e3o ao medidor Eastron<br><strong>18 <\/strong>Conex\u00e3o ao medidor Carlo Gavazzi<br><strong>19 <\/strong>Conex\u00e3o ao medidor SMA<br><strong>20 <\/strong>Conex\u00e3o ao inversor Deye \/ Turbo Energy<br><strong>21 <\/strong>Conex\u00e3o ao inversor ENPHASE<br><strong>22<\/strong> Conexi\u00f3n a medidor WiFi P1 Meter<br><strong>23<\/strong> Conex\u00e3o via Modbus<br><strong>25<\/strong> Conex\u00e3o ao medidor Shelly Pro<br><strong>26<\/strong> Conex\u00e3o ao inversor Growatt<br><strong>27<\/strong> Conex\u00e3o ao inversor Sungrow<br><strong>28 <\/strong>Liga\u00e7\u00e3o ao medidor LINKY LORA<br><strong>94 <\/strong>Medi\u00e7\u00e3o Car fora do intervalo<br><strong>95 <\/strong>Medida Grid fora de alcance<br><strong>96 <\/strong>Medida House fora de alcance<br><strong>97 <\/strong>Medida Battery fora de alcance<br><strong>98 <\/strong>Medida PV fora de alcance<br><strong>99<\/strong> Conex\u00e3o entre dois carregadores Trydan em modo de balanceamento de carga<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-separator uagb-block-b634b355\"><div class=\"wp-block-uagb-separator__inner\" style=\"--my-background-image:\"><\/div><\/div>\n\n\n\n<p><strong>Erros &#8211; B<\/strong><\/p>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-842d9744\">\n<div class=\"wp-block-uagb-container uagb-block-f682e240\">\n<p><strong>000<\/strong> Medidas fora de gama.<br><strong>Verificar<\/strong>:<br>\u2013 Se o carregador disp\u00f5e de um medidor interno. Verificar a marca, se \u00e9 monof\u00e1sico ou trif\u00e1sico, e configur\u00e1-lo no carregador atrav\u00e9s do painel de bot\u00f5es, ou contactar o suporte para o configurar remotamente se o carregador estiver online.<br>\u2013 Correta liga\u00e7\u00e3o f\u00edsica do medidor \u00e0 placa de pot\u00eancia.<br><br><strong><strong>001<\/strong> <\/strong>Para equipamentos Goodwe com protocolo UDP<strong><br><strong>Verificar:<\/strong><\/strong><br>\u2013 Tanto o inversor como o carregador est\u00e3o conectados \u00e0 internet. <br>\u2013 O IP do inversor est\u00e1 atribu\u00eddo incorretamente no e-Charger.<br><br><strong>002<\/strong> Para medidor V2C 1.0 e 2.0: os quadros chegam corrompidos.<br><strong>Verificar<\/strong>:<br>\u2013 Crimpagem correta do conector RJ-45 em ambas as extremidades.<br>\u2013 Configura\u00e7\u00e3o correta do controlo din\u00e2mico com o medidor selecionado correspondente \u00e0 instala\u00e7\u00e3o.<br><br><strong>003<\/strong> Poss\u00edvel ru\u00eddo no sinal V2C ControlBox.<br><strong>Verificar:<br><\/strong>\u2013 Crimpagem correta do conector RJ-45 em ambas as extremidades.<br>\u2013 Configura\u00e7\u00e3o correta do controlo din\u00e2mico com o medidor selecionado correspondente \u00e0 instala\u00e7\u00e3o.<br><br><strong>004<\/strong> Trydan est\u00e1 desconectado do WiFi e tentando reconectar, e o medidor WiFi usa essa tecnologia WiFi para conectar-se.<br><strong>Verificar<\/strong>:<br>\u2013 Conex\u00e3o correta de ambos os dispositivos \u00e0 mesma rede WiFi do cliente (n\u00e3o ao carregador).<br>\u2013 Garantir que a intensidade do sinal seja \u00f3tima ou melhorar a conex\u00e3o WiFi usando um repetidor.<br><br><strong>005<\/strong> O V2C ControlBox conectado atrav\u00e9s de RJ-45 n\u00e3o responde.<br><strong>Verificar<\/strong>:<br>\u2013 Crimpagem correta do conector RJ-45 em ambas as extremidades.<br><br><strong>006<\/strong> Foi feita uma solicita\u00e7\u00e3o HTTP e ocorreu falha de conex\u00e3o (Shelly, Solax, Kostal Piko, Enphase, P1 Meter, SAJ [Dados Solares], Wibeee). Falha ao tentar conectar ao servidor Modbus TCP (Huawei, Kostal Plenticore, Fronius, Ingeteam, SMA Sunny, SolarEdge, Victron).<br><strong>Verificar<\/strong>:<br>\u2013 Conex\u00e3o correta de ambos os dispositivos \u00e0 mesma rede WiFi do cliente (n\u00e3o ao carregador).<br>\u2013 O IP do inversor est\u00e1 atribu\u00eddo incorretamente no e-Charger.<br>\u2013 Garantir que a intensidade do sinal seja \u00f3tima ou melhorar a conex\u00e3o WiFi usando um repetidor.<br>\u2013 Configura\u00e7\u00e3o correta do inversor em rela\u00e7\u00e3o aos par\u00e2metros de comunica\u00e7\u00e3o com Trydan.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-71147356\">\n<p><strong>007<\/strong>  A busca autom\u00e1tica de Shelly n\u00e3o encontrou nenhum dispositivo.<br><strong>Verificar:<\/strong><br>\u2013 Mudan\u00e7a para IP fixo do Shelly no carregador Trydan.<br>\u2013 Conex\u00e3o correta de ambos os dispositivos \u00e0 mesma rede WiFi do cliente (n\u00e3o ao carregador).<br><br><strong>008<\/strong>  Foi selecionado um medidor com tecnologia WiFi e Trydan nunca se conectou \u00e0 rede WiFi configurada.<br><strong>Verificar:<\/strong><br>\u2013 Conex\u00e3o correta de ambos os dispositivos \u00e0 mesma rede WiFi do cliente com sinal suficiente (n\u00e3o ao carregador).<br><br><strong>009  <\/strong>Recebe-se um Timeout da solicita\u00e7\u00e3o ao medidor.<br><strong>Verificar:<\/strong><br>\u2013 Crimpagem correta do conector RJ-45 em ambas as extremidades.<br>\u2013 Configura\u00e7\u00e3o correta do inversor em rela\u00e7\u00e3o aos par\u00e2metros de comunica\u00e7\u00e3o com Trydan.<br>\u2013 Em caso de inversor ou medidor WiFi, a correta conex\u00e3o de ambos os dispositivos \u00e0 mesma rede WiFi do cliente com sinal suficiente (n\u00e3o ao carregador).<br>\u2013 O IP do inversor e a sua configura\u00e7\u00e3o correta no controlo din\u00e2mico de pot\u00eancia do Trydan.<br>\u2013 Inversor Solax: vers\u00e3o correta do Pocket WiFi V2.033.20 (link para download inclu\u00eddo no manual).<br><br><strong>010<\/strong>  Recebe-se dado de pin\u00e7a n\u00e3o conectada em um canal que \u00e9 necess\u00e1rio<br>(Mono + FV pin\u00e7a 1 ou 4, Trif\u00e1sico pin\u00e7as 1, 2 ou 3)<br><strong>Verificar:<\/strong><br>\u2013 Coloca\u00e7\u00e3o correta das pin\u00e7as nas fases indicadas no esquema correto de instala\u00e7\u00e3o em cada caso.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-00168f44\">\n<div class=\"wp-block-uagb-container uagb-block-c837e147\">\n<div class=\"wp-block-uagb-image aligncenter uagb-block-ded0ddba wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-center\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png ,https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png 780w, https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png\" alt=\"\" class=\"uag-image-125013\" width=\"50\" height=\"50\" title=\"\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-421a53a1\">\n<div class=\"wp-block-uagb-advanced-heading uagb-block-ab21f8f7\"><p class=\"uagb-heading-text\"><strong>NOTA IMPORTANTE:<\/strong> Se o <strong>c\u00f3digo de erro for superior a 011<\/strong>, s\u00e3o <strong>erros tipificados no protocolo MODBUS RTU ou TCP. Apenas para pessoal especializado.<\/strong> Pode gerar um pedido no Centro de Suporte T\u00e9cnico e entraremos em contacto o mais rapidamente poss\u00edvel.<\/p><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-a889f73f\">\n<div class=\"wp-block-uagb-container uagb-block-3ced5973\">\n<p><strong>021 <\/strong> LLEGAL_FUNCTION<br><strong>022<\/strong> ILLEGAL_DATA_ADDRESS<br><strong>023<\/strong> ILLEGAL_DATA_VALUE<br><strong>024<\/strong> SERVER_DEVICE_FAILURE<br><strong>025<\/strong> ACKNOWLEDGE<br><strong>026<\/strong> SERVER_DEVICE_BUSY<br><strong>027<\/strong> NEGATIVE_ACKNOWLEDGE<br><strong>028<\/strong> MEMORY_PARITY_ERROR<br><strong>030<\/strong> GATEWAY_PATH_UNAVAIL<br><strong>031<\/strong> GATEWAY_TARGET_NO_RESP<br><strong>032<\/strong> SERVER_RTU_INACTIVE<br><strong>244<\/strong> TIMEOUT<br><strong>245<\/strong> INVALID_SERVER<br><strong>246<\/strong> CRC_ERROR<br><strong>247<\/strong> FC_MISMATCH<br><strong>248<\/strong> SERVER_ID_MISMATCH<br><strong>249<\/strong> PACKET_LENGTH_ERROR<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-70caf82a\">\n<p><strong>250<\/strong>  PARAMETER_COUNT_ERROR<br><strong>251<\/strong>  PARAMETER_LIMIT_ERROR<br><strong>252<\/strong>  REQUEST_QUEUE_FULL<br><strong>253<\/strong>  ILLEGAL_IP_OR_PORT<br><strong>254<\/strong>  IP_CONNECTION_FAILED<br><strong>255<\/strong>  TCP_HEAD_MISMATCH<br><strong>256<\/strong>  EMPTY_MESSAGE<br><strong>275 <\/strong> UNDEFINED_ERROR<\/p>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-c6f38013 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-advanced-heading uagb-block-6963d70c\"><h2 class=\"uagb-heading-text\"><strong>Necessita de apoio t\u00e9cnico?<\/strong><\/h2><\/div>\n\n\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-408243eb\"><p class=\"uagb-heading-text\">Resolva a sua incid\u00eancia de imediato atrav\u00e9s do nosso Chat com IA. Se o problema n\u00e3o ficar resolvido, pedimos que crie um pedido no Centro de Suporte T\u00e9cnico e entraremos em contacto consigo o mais rapidamente poss\u00edvel para lhe oferecer a melhor solu\u00e7\u00e3o.<\/p><\/div>\n\n\n\n<div class=\"wp-block-uagb-info-box uagb-block-12e3cf1c uagb-infobox__content-wrap  uagb-infobox-icon-left uagb-infobox-left uagb-infobox-image-valign-top wp-block-uagb-info-box--has-margin ai-chatbot-button\"><div class=\"uagb-infobox-margin-wrapper\"><div class=\"uagb-ifb-image-content\"><img decoding=\"async\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2026\/01\/support-ai-chatbot.png\" alt=\"\" width=\"20\" height=\"19\" loading=\"lazy\"\/><\/div><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><\/div><div class=\"uagb-ifb-button-wrapper wp-block-button\"><a href=\"https:\/\/v2charge.com\/v2c-support-web\/\" class=\"uagb-infobox-cta-link wp-block-button__link\" target=\"_blank\" rel=\"noopener noreferrer\" onclick=\"return true;\"><span class=\"uagb-inline-editing\">Fale com o nosso Chat com IA<\/span><\/a><\/div><\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-buttons uagb-buttons__outer-wrap uagb-btn__default-btn uagb-btn-tablet__default-btn uagb-btn-mobile__default-btn uagb-block-ba1e67d1\"><div class=\"uagb-buttons__wrap uagb-buttons-layout-wrap \">\n<div class=\"wp-block-uagb-buttons-child uagb-buttons__outer-wrap uagb-block-23cfb623 wp-block-button\"><div class=\"uagb-button__wrapper\"><a class=\"uagb-buttons-repeater wp-block-button__link\" aria-label=\"\" href=\"https:\/\/v2charge.atlassian.net\/servicedesk\/customer\/portal\/3\" rel=\"follow noopener\" target=\"_blank\" role=\"button\"><div class=\"uagb-button__link\">Contacte o Suporte T\u00e9cnico<\/div><\/a><\/div><\/div>\n<\/div><\/div>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>C\u00f3digos de erros de conex\u00e3o e a sua solu\u00e7\u00e3o Se ao ativar o controlo din\u00e2mico de pot\u00eancia no carregador Trydan ou Trydan Pro ocorrer um erro, no display do carregador aparecer\u00e1 um c\u00f3digo correspondente ao erro. Las soluciones a los errores establecidos a continuaci\u00f3n corresponden a la versi\u00f3n 1.6.18 o superiores. En caso de tener &#8230; <a title=\"C\u00f3digos de erros de conex\u00e3o e a sua solu\u00e7\u00e3o\" class=\"read-more\" href=\"https:\/\/v2charge.com\/pt-pt\/suporte\/controlo-potencia\/dinamico\/solucao-erros\/\" aria-label=\"Leia mais sobre C\u00f3digos de erros de conex\u00e3o e a sua solu\u00e7\u00e3o\">Ler mais<\/a><\/p>\n","protected":false},"author":400,"featured_media":170353,"parent":125468,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_eb_attr":"","content-type":"","_uag_custom_page_level_css":"","footnotes":""},"class_list":["post-188156","page","type-page","status-publish","has-post-thumbnail"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.3.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>C\u00f3digos de erros de conex\u00e3o e a sua solu\u00e7\u00e3o - Area de Suporte<\/title>\n<meta name=\"description\" content=\"Apresenta-se um erro de conex\u00e3o no display do Trydan? Conhe\u00e7a o significado do erro e a sua solu\u00e7\u00e3o | \u00c1rea de Suporte\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/v2charge.com\/pt-pt\/suporte\/controlo-potencia\/dinamico\/solucao-erros\/\" \/>\n<meta property=\"og:locale\" content=\"pt_PT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"C\u00f3digos de erros de conex\u00e3o e a sua solu\u00e7\u00e3o - Area de Suporte\" \/>\n<meta property=\"og:description\" content=\"Apresenta-se um erro de conex\u00e3o no display do Trydan? Conhe\u00e7a o significado do erro e a sua solu\u00e7\u00e3o | \u00c1rea de Suporte\" \/>\n<meta property=\"og:url\" content=\"https:\/\/v2charge.com\/pt-pt\/suporte\/controlo-potencia\/dinamico\/solucao-erros\/\" \/>\n<meta property=\"og:site_name\" content=\"V2C\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/V2C.Charge\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-13T14:48:24+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"675\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@V2C_Charge\" \/>\n<meta name=\"twitter:label1\" content=\"Tempo estimado de leitura\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/v2charge.com\/pt-pt\/suporte\/controlo-potencia\/dinamico\/solucao-erros\/\",\"url\":\"https:\/\/v2charge.com\/pt-pt\/suporte\/controlo-potencia\/dinamico\/solucao-erros\/\",\"name\":\"C\u00f3digos de erros de conex\u00e3o e a sua solu\u00e7\u00e3o - Area de Suporte\",\"isPartOf\":{\"@id\":\"https:\/\/v2charge.com\/pt-pt\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/v2charge.com\/pt-pt\/suporte\/controlo-potencia\/dinamico\/solucao-erros\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/v2charge.com\/pt-pt\/suporte\/controlo-potencia\/dinamico\/solucao-erros\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg\",\"datePublished\":\"2024-11-11T12:54:31+00:00\",\"dateModified\":\"2026-01-13T14:48:24+00:00\",\"description\":\"Apresenta-se um erro de conex\u00e3o no display do Trydan? Conhe\u00e7a o significado do erro e a sua solu\u00e7\u00e3o | \u00c1rea de Suporte\",\"breadcrumb\":{\"@id\":\"https:\/\/v2charge.com\/pt-pt\/suporte\/controlo-potencia\/dinamico\/solucao-erros\/#breadcrumb\"},\"inLanguage\":\"pt-PT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/v2charge.com\/pt-pt\/suporte\/controlo-potencia\/dinamico\/solucao-erros\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-PT\",\"@id\":\"https:\/\/v2charge.com\/pt-pt\/suporte\/controlo-potencia\/dinamico\/solucao-erros\/#primaryimage\",\"url\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg\",\"contentUrl\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg\",\"width\":1200,\"height\":675,\"caption\":\"V2C Electric Chargers\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/v2charge.com\/pt-pt\/suporte\/controlo-potencia\/dinamico\/solucao-erros\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"V2C\",\"item\":\"https:\/\/v2charge.com\/pt-pt\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u00c1rea de Suporte\",\"item\":\"https:\/\/v2charge.com\/pt-pt\/suporte\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Controlo de pot\u00eancia\",\"item\":\"https:\/\/v2charge.com\/pt-pt\/suporte\/controlo-potencia\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Din\u00e2mico\",\"item\":\"https:\/\/v2charge.com\/pt-pt\/suporte\/controlo-potencia\/dinamico\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"C\u00f3digos de erros de conex\u00e3o e a sua solu\u00e7\u00e3o\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/v2charge.com\/pt-pt\/#website\",\"url\":\"https:\/\/v2charge.com\/pt-pt\/\",\"name\":\"V2C\",\"description\":\"#CargandoElMa\u00f1ana\",\"publisher\":{\"@id\":\"https:\/\/v2charge.com\/pt-pt\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/v2charge.com\/pt-pt\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pt-PT\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/v2charge.com\/pt-pt\/#organization\",\"name\":\"V2C\",\"url\":\"https:\/\/v2charge.com\/pt-pt\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-PT\",\"@id\":\"https:\/\/v2charge.com\/pt-pt\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png\",\"contentUrl\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png\",\"width\":984,\"height\":431,\"caption\":\"V2C\"},\"image\":{\"@id\":\"https:\/\/v2charge.com\/pt-pt\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/V2C.Charge\",\"https:\/\/x.com\/V2C_Charge\",\"https:\/\/www.instagram.com\/v2c.charge\/\",\"https:\/\/www.youtube.com\/@V2C\",\"https:\/\/www.linkedin.com\/company\/v2c-chargers\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"C\u00f3digos de erros de conex\u00e3o e a sua solu\u00e7\u00e3o - Area de Suporte","description":"Apresenta-se um erro de conex\u00e3o no display do Trydan? Conhe\u00e7a o significado do erro e a sua solu\u00e7\u00e3o | \u00c1rea de Suporte","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/v2charge.com\/pt-pt\/suporte\/controlo-potencia\/dinamico\/solucao-erros\/","og_locale":"pt_PT","og_type":"article","og_title":"C\u00f3digos de erros de conex\u00e3o e a sua solu\u00e7\u00e3o - Area de Suporte","og_description":"Apresenta-se um erro de conex\u00e3o no display do Trydan? Conhe\u00e7a o significado do erro e a sua solu\u00e7\u00e3o | \u00c1rea de Suporte","og_url":"https:\/\/v2charge.com\/pt-pt\/suporte\/controlo-potencia\/dinamico\/solucao-erros\/","og_site_name":"V2C","article_publisher":"https:\/\/www.facebook.com\/V2C.Charge","article_modified_time":"2026-01-13T14:48:24+00:00","og_image":[{"width":1200,"height":675,"url":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@V2C_Charge","twitter_misc":{"Tempo estimado de leitura":"6 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/v2charge.com\/pt-pt\/suporte\/controlo-potencia\/dinamico\/solucao-erros\/","url":"https:\/\/v2charge.com\/pt-pt\/suporte\/controlo-potencia\/dinamico\/solucao-erros\/","name":"C\u00f3digos de erros de conex\u00e3o e a sua solu\u00e7\u00e3o - Area de Suporte","isPartOf":{"@id":"https:\/\/v2charge.com\/pt-pt\/#website"},"primaryImageOfPage":{"@id":"https:\/\/v2charge.com\/pt-pt\/suporte\/controlo-potencia\/dinamico\/solucao-erros\/#primaryimage"},"image":{"@id":"https:\/\/v2charge.com\/pt-pt\/suporte\/controlo-potencia\/dinamico\/solucao-erros\/#primaryimage"},"thumbnailUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","datePublished":"2024-11-11T12:54:31+00:00","dateModified":"2026-01-13T14:48:24+00:00","description":"Apresenta-se um erro de conex\u00e3o no display do Trydan? Conhe\u00e7a o significado do erro e a sua solu\u00e7\u00e3o | \u00c1rea de Suporte","breadcrumb":{"@id":"https:\/\/v2charge.com\/pt-pt\/suporte\/controlo-potencia\/dinamico\/solucao-erros\/#breadcrumb"},"inLanguage":"pt-PT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/v2charge.com\/pt-pt\/suporte\/controlo-potencia\/dinamico\/solucao-erros\/"]}]},{"@type":"ImageObject","inLanguage":"pt-PT","@id":"https:\/\/v2charge.com\/pt-pt\/suporte\/controlo-potencia\/dinamico\/solucao-erros\/#primaryimage","url":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","contentUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","width":1200,"height":675,"caption":"V2C Electric Chargers"},{"@type":"BreadcrumbList","@id":"https:\/\/v2charge.com\/pt-pt\/suporte\/controlo-potencia\/dinamico\/solucao-erros\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"V2C","item":"https:\/\/v2charge.com\/pt-pt\/"},{"@type":"ListItem","position":2,"name":"\u00c1rea de Suporte","item":"https:\/\/v2charge.com\/pt-pt\/suporte\/"},{"@type":"ListItem","position":3,"name":"Controlo de pot\u00eancia","item":"https:\/\/v2charge.com\/pt-pt\/suporte\/controlo-potencia\/"},{"@type":"ListItem","position":4,"name":"Din\u00e2mico","item":"https:\/\/v2charge.com\/pt-pt\/suporte\/controlo-potencia\/dinamico\/"},{"@type":"ListItem","position":5,"name":"C\u00f3digos de erros de conex\u00e3o e a sua solu\u00e7\u00e3o"}]},{"@type":"WebSite","@id":"https:\/\/v2charge.com\/pt-pt\/#website","url":"https:\/\/v2charge.com\/pt-pt\/","name":"V2C","description":"#CargandoElMa\u00f1ana","publisher":{"@id":"https:\/\/v2charge.com\/pt-pt\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/v2charge.com\/pt-pt\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pt-PT"},{"@type":"Organization","@id":"https:\/\/v2charge.com\/pt-pt\/#organization","name":"V2C","url":"https:\/\/v2charge.com\/pt-pt\/","logo":{"@type":"ImageObject","inLanguage":"pt-PT","@id":"https:\/\/v2charge.com\/pt-pt\/#\/schema\/logo\/image\/","url":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png","contentUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png","width":984,"height":431,"caption":"V2C"},"image":{"@id":"https:\/\/v2charge.com\/pt-pt\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/V2C.Charge","https:\/\/x.com\/V2C_Charge","https:\/\/www.instagram.com\/v2c.charge\/","https:\/\/www.youtube.com\/@V2C","https:\/\/www.linkedin.com\/company\/v2c-chargers\/"]}]}},"uagb_featured_image_src":{"full":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"thumbnail":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-150x150.jpg",150,150,true],"medium":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-300x169.jpg",300,169,true],"medium_large":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-768x432.jpg",768,432,true],"large":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-1024x576.jpg",1024,576,true],"gs-tiny":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",50,28,false],"xl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxxxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxxxxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"1536x1536":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"2048x2048":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false]},"uagb_author_info":{"display_name":"V2C","author_link":"https:\/\/v2charge.com\/pt-pt\/author\/marketing\/"},"uagb_comment_info":0,"uagb_excerpt":"C\u00f3digos de erros de conex\u00e3o e a sua solu\u00e7\u00e3o Se ao ativar o controlo din\u00e2mico de pot\u00eancia no carregador Trydan ou Trydan Pro ocorrer um erro, no display do carregador aparecer\u00e1 um c\u00f3digo correspondente ao erro. Las soluciones a los errores establecidos a continuaci\u00f3n corresponden a la versi\u00f3n 1.6.18 o superiores. En caso de tener&hellip;","_links":{"self":[{"href":"https:\/\/v2charge.com\/pt-pt\/wp-json\/wp\/v2\/pages\/188156","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/v2charge.com\/pt-pt\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/v2charge.com\/pt-pt\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/v2charge.com\/pt-pt\/wp-json\/wp\/v2\/users\/400"}],"replies":[{"embeddable":true,"href":"https:\/\/v2charge.com\/pt-pt\/wp-json\/wp\/v2\/comments?post=188156"}],"version-history":[{"count":11,"href":"https:\/\/v2charge.com\/pt-pt\/wp-json\/wp\/v2\/pages\/188156\/revisions"}],"predecessor-version":[{"id":295433,"href":"https:\/\/v2charge.com\/pt-pt\/wp-json\/wp\/v2\/pages\/188156\/revisions\/295433"}],"up":[{"embeddable":true,"href":"https:\/\/v2charge.com\/pt-pt\/wp-json\/wp\/v2\/pages\/125468"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/v2charge.com\/pt-pt\/wp-json\/wp\/v2\/media\/170353"}],"wp:attachment":[{"href":"https:\/\/v2charge.com\/pt-pt\/wp-json\/wp\/v2\/media?parent=188156"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}