{"id":330456,"date":"2024-10-04T15:39:28","date_gmt":"2024-10-04T13:39:28","guid":{"rendered":""},"modified":"2026-01-13T16:45:07","modified_gmt":"2026-01-13T14:45:07","slug":"kody-ch-b-pripojenia-a-ich-rie-enie","status":"publish","type":"page","link":"https:\/\/v2charge.com\/sk\/oblas-podpory\/ovladanie-v-konu\/dynamicke-riadenie-v-konu\/kody-ch-b-pripojenia-a-ich-rie-enie\/","title":{"rendered":"K\u00f3dy ch\u00fdb pripojenia a ich rie\u0161enie"},"content":{"rendered":"\n<div class=\"wp-block-uagb-container uagb-block-9d828d1c alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><div class=\"yoast-breadcrumbs\"><span><span><a href=\"https:\/\/v2charge.com\/sk\/\">V2C<\/a><\/span> \u00bb <span><a href=\"https:\/\/v2charge.com\/sk\/oblas-podpory\/\">Oblas\u0165 podpory<\/a><\/span> \u00bb <span><a href=\"https:\/\/v2charge.com\/sk\/ovladanie-v-konu\/\">Control de potencia<\/a><\/span> \u00bb <span><a href=\"https:\/\/v2charge.com\/sk\/dynamicke-riadenie-v-konu\/\">Din\u00e1mico<\/a><\/span> \u00bb <span class=\"breadcrumb_last\" aria-current=\"page\">K\u00f3dy ch\u00fdb pripojenia a ich rie\u0161enie<\/span><\/span><\/div>\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-be8360a4\"><h1 class=\"uagb-heading-text\">K\u00f3dy ch\u00fdb pripojenia a ich rie\u0161enie<\/h1><\/div>\n\n<p class=\"wp-block-paragraph\">Ak pri aktiv\u00e1cii dynamick\u00e9ho riadenia v\u00fdkonu na nab\u00edja\u010dke Trydan alebo Trydan Pro d\u00f4jde k chybe, na displeji nab\u00edja\u010dky sa zobraz\u00ed <strong>k\u00f3d zodpovedaj\u00faci chybe<\/strong>.<br><br>Rie\u0161enia pre chyby uveden\u00e9 ni\u017e\u0161ie sa vz\u0165ahuj\u00fa na <strong>verziu 1.6.18 alebo vy\u0161\u0161ie<\/strong>. V pr\u00edpade, \u017ee m\u00e1te ni\u017e\u0161iu verziu, <a href=\"https:\/\/v2charge.com\/sk\/soporte\/trydan\/actualizar-ultima-version\/\"><strong>aktualizujte nab\u00edja\u010dku Trydan<\/strong><\/a> a znova skontrolujte nasleduj\u00faci zoznam.<\/p><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-f83ba0fb alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-9d537ef2\">\n<div class=\"wp-block-uagb-container uagb-block-1021f2c1\">\n<div class=\"wp-block-uagb-image aligncenter uagb-block-f5b78000 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-center\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png ,https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png 780w, https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png\" alt=\"\" class=\"uag-image-125013\" width=\"50\" height=\"50\" title=\"\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-a8351972\"><div class=\"wp-block-uagb-advanced-heading uagb-block-fdcb9def\"><p class=\"uagb-heading-text\"><strong>D\u00d4LE\u017dIT\u00c1 POZN\u00c1MKA:<\/strong> tieto chyby vypl\u00fdvaj\u00fa z poruchy komunik\u00e1cie medzi Trydan a invertorom alebo merac\u00edm pr\u00edstrojom a obmedzuj\u00fa nab\u00edjanie v\u00e1\u0161ho vozidla na minimum. Niektor\u00e9 sa m\u00f4\u017eu vyskytn\u00fa\u0165, ke\u010f je integr\u00e1cia priamo s invertorom, \u010di u\u017e prostredn\u00edctvom komunik\u00e1cie Modbus alebo RS485.<br><strong>Je nevyhnutn\u00e9 konzultova\u0165 rie\u0161enie chyby, ktor\u00e1 sa zobrazuje na displeji. <\/strong>Ak chyba pretrv\u00e1va, ozn\u00e1mte to n\u00e1\u0161mu oddeleniu technickej podpory a deaktivujte dynamick\u00e9 riadenie nab\u00edjania, aby ste mohli nab\u00edja\u0165 pri stanovenom pevn\u00e9m pr\u00fade.<\/p><\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-separator uagb-block-b0f92113\"><div class=\"wp-block-uagb-separator__inner\" style=\"--my-background-image:\"><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-4d0c1e2a\">\n<div class=\"wp-block-uagb-container uagb-block-195968cb\"><table style=\"border:none;\">\n    <tr style=\"border:none;\">\n        <th style=\"border:none;\">CHYBA<\/th>\n        <th style=\"border:none;\"><u>00<\/u><\/th>\n        <th style=\"border:none;\"><u>000<\/u><\/th>\n    <\/tr>\n    <tr style=\"border:none;\">\n        <td style=\"border:none;\"><\/td>\n        <td style=\"border:none;\"><center>A<\/center><\/td>\n        <td style=\"border:none;\"><center>B<\/center><\/td>\n    <\/tr>\n<\/table><\/div>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Prv\u00e9 <strong>dve \u010d\u00edslice<\/strong> ozna\u010duj\u00fa merac\u00ed pr\u00edstroj alebo invertor, ktor\u00fd pou\u017e\u00edvame. Je d\u00f4le\u017eit\u00e9 vybra\u0165 ten spr\u00e1vny pri nastavovan\u00ed dynamickej kontroly v\u00fdkonu a skontrolova\u0165, \u010di je spr\u00e1vny v pr\u00edpade chyby.<\/p>\n\n\n<div class=\"wp-block-uagb-container uagb-block-8616beaf\">\n<div class=\"wp-block-uagb-container uagb-block-9f8097ef\"><p class=\"wp-block-paragraph\"><strong>Chyby &#8211; A<\/strong><\/p><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-4816f3c8\"><p class=\"wp-block-paragraph\"><strong>00<\/strong>  Medidor Shelly<br><strong>01<\/strong>  V2C ControlBox<br><strong>02<\/strong>  Medidor V2C 1.0<br><strong>03<\/strong>  Pripojenie k invertoru Huawei<br><strong>04<\/strong>  Pripojenie k invertoru Solax<br><strong>05<\/strong>  Pripojenie k invertoru Kostal<br><strong>06<\/strong>  Pripojenie k invertoru Fronius<br><strong>07<\/strong>  Pripojenie k invertoru Ingeteam<br><strong>08  <\/strong>Pripojenie k medidoru Wibeee<br><strong>09<\/strong>  Pripojenie k medidoru Victron<br><strong>10<\/strong>  Pripojenie k invertoru SolarEdge<br><strong>11<\/strong>  Pou\u017eitie protokolu MQTT<\/p><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-8ef7ba8e\"><p class=\"wp-block-paragraph\"><strong>12<\/strong> Pripojenie k invertoru Goodwe<br><strong>13<\/strong> Pripojenie k invertoru SAJ \/ GreenHeiss<br><strong>14<\/strong> Pripojenie k invertoru Solis<br><strong>15<\/strong> Pripojenie k meraciemu Chint DDSU666<br><strong>16<\/strong> Pripojenie k meraciemu Eastron<br><strong>17<\/strong> Pripojenie k meraciemu Phoneix Contact<br><strong>18<\/strong> Pripojenie k meraciemu Carlo Gavazzi<br><strong>19<\/strong> Pripojenie k meraciemu SMA<br><strong>20<\/strong> Pripojenie k invertoru Deye \/ Turbo Energy<br><strong>21<\/strong> Pripojenie k invertoru ENPHASE<br><strong>22<\/strong> Pripojenie k meraciemu WiFi P1 Meter<br><strong>23 <\/strong>Pripojenie cez Modbus<br><strong>25<\/strong> Pripojenie k meraciemu Shelly Pro<br><strong>26<\/strong> Pripojenie k invertoru Growatt<br><strong>27<\/strong> Pripojenie k invertoru Sungrow<br><strong>28 <\/strong>Pripojenie k meraciemu LINKY LORA<br><strong>94<\/strong> Mimo rozsahu merania Car<br><strong>95<\/strong> Mimo rozsahu merania Grid<br><strong>96<\/strong> Mimo rozsahu merania House<br><strong>97<\/strong> Mimo rozsahu merania Battery<br><strong>98 <\/strong>Mimo rozsahu merania FV<br><strong>99 <\/strong>Pripojenie medzi dvoma nab\u00edja\u010dkami Trydan v re\u017eime vyv\u00e1\u017eenia za\u0165a\u017eenia<\/p><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-separator uagb-block-b634b355\"><div class=\"wp-block-uagb-separator__inner\" style=\"--my-background-image:\"><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><strong>Chyby &#8211; B<\/strong><\/p>\n\n\n<div class=\"wp-block-uagb-container uagb-block-842d9744\">\n<div class=\"wp-block-uagb-container uagb-block-f682e240\"><p class=\"wp-block-paragraph\"><strong>000<\/strong>&nbsp;Mierky mimo rozsah.<br><strong><strong>Skontrolova\u0165<\/strong><\/strong>:<br>&#8211; Ak m\u00e1 nab\u00edja\u010dka vn\u00fatorn\u00fd merac\u00ed pr\u00edstroj. Skontrolujte zna\u010dku, \u010di je jednof\u00e1zov\u00fd alebo trojf\u00e1zov\u00fd, a nastavte ho na nab\u00edja\u010dke pomocou ovl\u00e1dacieho panela, alebo kontaktujte podporu na vzdialen\u00e9 nastavenie, ak je nab\u00edja\u010dka online.<br>&#8211; Spr\u00e1vne fyzick\u00e9 pripojenie meracieho pr\u00edstroja k v\u00fdkonovej doske.<br><br><strong><strong>001<\/strong> <\/strong>Pre zariadenia Goodwe s protokolom UDP<strong><br><strong>Skontrolova\u0165<\/strong><\/strong>:<br>&#8211; \u010ci s\u00fa invertor aj nab\u00edja\u010dka pripojen\u00e9 na internet.<br> &#8211; IP adresa invertora je nespr\u00e1vne priraden\u00e1 v e-Charger.<br><br><strong>002<\/strong> Pre merac\u00ed pr\u00edstroj V2C 1.0 a 2.0: r\u00e1mce prich\u00e1dzaj\u00fa po\u0161koden\u00e9.<br><strong>Skontrolova\u0165<\/strong>:<br>&#8211; Spr\u00e1vne krimpovanie konektora RJ-45 na oboch koncoch.<br>&#8211; Spr\u00e1vne nastavenie dynamick\u00e9ho ovl\u00e1dania s vybran\u00fdm merac\u00edm pr\u00edstrojom zodpovedaj\u00facim in\u0161tal\u00e1cii.<br><br><strong>003<\/strong> Mo\u017en\u00fd \u0161um v sign\u00e1le V2C ControlBox.<br><strong>Skontrolova\u0165:<br><\/strong>&#8211; Spr\u00e1vne krimpovanie konektora RJ-45 na oboch koncoch.<br>&#8211; Spr\u00e1vne nastavenie dynamick\u00e9ho ovl\u00e1dania s vybran\u00fdm merac\u00edm pr\u00edstrojom zodpovedaj\u00facim in\u0161tal\u00e1cii.<br><br><strong>004<\/strong> Trydan je odpojen\u00fd od WiFi a pok\u00fa\u0161a sa znovu pripoji\u0165 a merac\u00ed pr\u00edstroj WiFi pou\u017e\u00edva t\u00fato technol\u00f3giu WiFi na pripojenie.<br><strong>Skontrolova\u0165<\/strong>:<br>&#8211; Spr\u00e1vne pripojenie oboch zariaden\u00ed k tej istej WiFi z\u00e1kazn\u00edka (nie k nab\u00edja\u010dke)<br>&#8211; Aby bola intenzita sign\u00e1lu optim\u00e1lna alebo zlep\u0161i\u0165 pripojenie WiFi pomocou opakova\u010da, ku ktor\u00e9mu s\u00fa obidve pripojen\u00e9.<br><br><strong>005<\/strong> V2C ControlBox pripojen\u00fd cez RJ-45 neodpoved\u00e1.<br><strong>Skontrolova\u0165<\/strong>:<br>&#8211; Spr\u00e1vne krimpovanie konektora RJ-45 na oboch koncoch.<br><br><strong>006<\/strong> Vykon\u00e1va sa po\u017eiadavka HTTP a doch\u00e1dza k chybe pripojenia (Shelly, Solax, Kostal Piko, Enphase, P1 Meter, SAJ [\u00dadaje o sol\u00e1rnej energii], Wibeee). Chyba pri pokuse o pripojenie k serveru Modbus TCP (Huawei, Kostal Plenticore, Fronius, Ingeteam, SMA Sunny, SolarEdge, Victron).<br><strong>Skontrolova\u0165<\/strong>:<br>&#8211; Spr\u00e1vne pripojenie oboch zariaden\u00ed k tej istej WiFi z\u00e1kazn\u00edka (nie k nab\u00edja\u010dke).<br>&#8211; IP adresa invertora je nespr\u00e1vne priraden\u00e1 v e-Charger.<br>&#8211; Aby bola intenzita sign\u00e1lu optim\u00e1lna alebo zlep\u0161i\u0165 pripojenie WiFi pomocou opakova\u010da, ku ktor\u00e9mu s\u00fa obidve pripojen\u00e9.<br>&#8211; Spr\u00e1vne nastavenie invertora vzh\u013eadom na parametre komunik\u00e1cie s Trydan.<\/p><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-71147356\"><p class=\"wp-block-paragraph\"><strong>007<\/strong> Automatick\u00e9 vyh\u013ead\u00e1vanie Shelly nena\u0161lo \u017eiadne zariadenie.<br><strong>Skontrolova\u0165<\/strong>:<br>&#8211; Zmena na statick\u00fa IP adresu Shelly v nab\u00edja\u010dke Trydan.<br>&#8211; Spr\u00e1vne pripojenie oboch zariaden\u00ed na rovnak\u00fa WiFi klienta (nie na nab\u00edja\u010dku).<br><br><strong>008<\/strong> Bol vybran\u00fd merac\u00ed pr\u00edstroj s technol\u00f3giou WiFi a Trydan sa nikdy nepripojil k nakonfigurovanej WiFi sieti.<br><strong>Skontrolova\u0165<\/strong>:<br>&#8211; Spr\u00e1vne pripojenie oboch zariaden\u00ed na rovnak\u00fa WiFi klienta s dostato\u010dn\u00fdm sign\u00e1lom (nie na nab\u00edja\u010dku).<br><br><strong>009 <\/strong>Prij\u00edma sa Timeout po\u017eiadavky na merac\u00ed pr\u00edstroj.<br><strong>Skontrolova\u0165<\/strong>:<br>&#8211; Spr\u00e1vne krimpovanie konektora RJ-45 na oboch koncoch.<br>&#8211; Spr\u00e1vna konfigur\u00e1cia invertora vzh\u013eadom na parametre komunik\u00e1cie s Trydan.<br>&#8211; V pr\u00edpade invertora alebo meracieho pr\u00edstroja WiFi spr\u00e1vne pripojenie oboch zariaden\u00ed na rovnak\u00fa WiFi klienta s dostato\u010dn\u00fdm sign\u00e1lom (nie na nab\u00edja\u010dku).<br>&#8211; IP adresa invertora a spr\u00e1vne ju nastavi\u0165 v dynamickej kontrole v\u00fdkonu Trydan.<br>&#8211; Invertor Solax: Spr\u00e1vna verzia Pocket WiFi V2.033.20 (odkaz na stiahnutie je zahrnut\u00fd v manu\u00e1li).<br><br><strong>010<\/strong> Prij\u00edma sa \u00fadaj o nezapojenej svorke na kan\u00e1li, ktor\u00fd je potrebn\u00fd<br>(Mono + FV svorka 1 alebo 4, Trojf\u00e1zov\u00fd svorky 1, 2 alebo 3)<br><strong>Skontrolova\u0165<\/strong>:<br>&#8211; Spr\u00e1vne umiestnenie svoriek na f\u00e1zach uveden\u00fdch v spr\u00e1vnom sch\u00e9me in\u0161tal\u00e1cie v ka\u017edom pr\u00edpade.<\/p><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-00168f44\">\n<div class=\"wp-block-uagb-container uagb-block-c837e147\">\n<div class=\"wp-block-uagb-image aligncenter uagb-block-ded0ddba wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-center\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png ,https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png 780w, https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png\" alt=\"\" class=\"uag-image-125013\" width=\"50\" height=\"50\" title=\"\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-421a53a1\"><div class=\"wp-block-uagb-advanced-heading uagb-block-ab21f8f7\"><p class=\"uagb-heading-text\"><strong>D\u00d4LE\u017dIT\u00c1 POZN\u00c1MKA:<\/strong> Ak je <strong>chyba k\u00f3du v\u00e4\u010d\u0161ia ako 011<\/strong>, ide o <strong>chyby typizovan\u00e9 v protokole MODBUS RTU alebo TCP. Iba pre odborn\u00fd person\u00e1l.<\/strong> M\u00f4\u017eete vytvori\u0165 \u017eiados\u0165 v Technickom podpornom centre a \u010doskoro sa s vami skontaktujeme.<\/p><\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-a889f73f\">\n<div class=\"wp-block-uagb-container uagb-block-3ced5973\"><p class=\"wp-block-paragraph\"><strong>021 <\/strong> NELEG\u00c1LNA_FUNKCIA<br><strong>022<\/strong> NELEG\u00c1LNA_ADRESA_D\u00c1T<br><strong>023<\/strong> NELEG\u00c1LNA_HODNOTA_D\u00c1T<br><strong>024<\/strong> ZLYHANIE_SERVEROV\u00c9HO_ZARIADENIA<br><strong>025<\/strong> POTVRDI\u0164<br><strong>026<\/strong> SERVEROV\u00c9_ZARIADENIE_ZANEPR\u00c1ZDNEN\u00c9<br><strong>027<\/strong> NEGAT\u00cdVNE_POTVRDENIE<br><strong>028<\/strong> CHYBA_PARITY_PAM\u00c4TE<br><strong>030<\/strong> CESTA_GATWAY_NEDOSTUPN\u00c1<br><strong>031<\/strong> CIE\u013d_GATWAY_NEODPOVED\u00c1<br><strong>032<\/strong> SERVER_RTU_NEAKT\u00cdVNY<br><strong>244<\/strong> \u010cASOV\u00dd_LIMIT<br><strong>245<\/strong> NEPLATN\u00dd_SERVER<br><strong>246<\/strong> CHYBA_CRC<br><strong>247<\/strong> NES\u00daLAD_FC<br><strong>248<\/strong> NES\u00daLAD_ID_SERVERA<br><strong>249<\/strong> CHYBA_D\u0139\u017dKY_BLOKU<\/p><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-70caf82a\"><p class=\"wp-block-paragraph\"><strong>250<\/strong>  PARAMETER_COUNT_ERROR<br><strong>251<\/strong>  PARAMETER_LIMIT_ERROR<br><strong>252<\/strong>  REQUEST_QUEUE_FULL<br><strong>253<\/strong>  ILLEGAL_IP_OR_PORT<br><strong>254<\/strong>  IP_CONNECTION_FAILED<br><strong>255<\/strong>  TCP_HEAD_MISMATCH<br><strong>256<\/strong>  EMPTY_MESSAGE<br><strong>275 <\/strong> UNDEFINED_ERROR<\/p><\/div>\n<\/div>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-c6f38013 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><div class=\"wp-block-uagb-advanced-heading uagb-block-6963d70c\"><h2 class=\"uagb-heading-text\"><strong>Potrebujete technick\u00fa podporu?<\/strong><\/h2><\/div>\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-408243eb\"><p class=\"uagb-heading-text\">Rie\u0161 svoj probl\u00e9m okam\u017eite prostredn\u00edctvom n\u00e1\u0161ho chatu s AI. Ak sa probl\u00e9m nevyrie\u0161i, vytvor \u017eiados\u0165 v Technickom podpornom centre a \u010doskoro sa s tebou skontaktujeme, aby sme ti pon\u00fakli najlep\u0161ie rie\u0161enie.<\/p><\/div>\n\n<div class=\"wp-block-uagb-info-box uagb-block-12e3cf1c uagb-infobox__content-wrap  uagb-infobox-icon-left uagb-infobox-left uagb-infobox-image-valign-top wp-block-uagb-info-box--has-margin ai-chatbot-button\"><div class=\"uagb-infobox-margin-wrapper\"><div class=\"uagb-ifb-image-content\"><img decoding=\"async\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2026\/01\/support-ai-chatbot.png\" alt=\"\" width=\"20\" height=\"19\" loading=\"lazy\"\/><\/div><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><\/div><div class=\"uagb-ifb-button-wrapper wp-block-button\"><a href=\"https:\/\/v2charge.com\/sk\/v2c-support-web\/\" class=\"uagb-infobox-cta-link wp-block-button__link\" target=\"_blank\" rel=\"noopener noreferrer\" onclick=\"return true;\"><span class=\"uagb-inline-editing\">Op\u00fdtajte sa n\u00e1\u0161ho AI chatu<\/span><\/a><\/div><\/div><\/div><\/div>\n\n\n<div class=\"wp-block-uagb-buttons uagb-buttons__outer-wrap uagb-btn__default-btn uagb-btn-tablet__default-btn uagb-btn-mobile__default-btn uagb-block-ba1e67d1\"><div class=\"uagb-buttons__wrap uagb-buttons-layout-wrap \"><div class=\"wp-block-uagb-buttons-child uagb-buttons__outer-wrap uagb-block-23cfb623 wp-block-button\"><div class=\"uagb-button__wrapper\"><a class=\"uagb-buttons-repeater wp-block-button__link\" aria-label=\"\" href=\"https:\/\/v2charge.atlassian.net\/servicedesk\/customer\/portal\/3\" rel=\"follow noopener\" target=\"_blank\" role=\"button\"><div class=\"uagb-button__link\">Kontaktujte technick\u00fa podporu<\/div><\/a><\/div><\/div><\/div><\/div>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>K\u00f3dy ch\u00fdb pripojenia a ich rie\u0161enie Ak pri aktiv\u00e1cii dynamick\u00e9ho riadenia v\u00fdkonu na nab\u00edja\u010dke Trydan alebo Trydan Pro d\u00f4jde k chybe, na displeji nab\u00edja\u010dky sa zobraz\u00ed k\u00f3d zodpovedaj\u00faci chybe. Rie\u0161enia pre chyby uveden\u00e9 ni\u017e\u0161ie sa vz\u0165ahuj\u00fa na verziu 1.6.18 alebo vy\u0161\u0161ie. V pr\u00edpade, \u017ee m\u00e1te ni\u017e\u0161iu verziu, aktualizujte nab\u00edja\u010dku Trydan a znova skontrolujte nasleduj\u00faci zoznam. &#8230; <a title=\"K\u00f3dy ch\u00fdb pripojenia a ich rie\u0161enie\" class=\"read-more\" href=\"https:\/\/v2charge.com\/sk\/oblas-podpory\/ovladanie-v-konu\/dynamicke-riadenie-v-konu\/kody-ch-b-pripojenia-a-ich-rie-enie\/\" aria-label=\"Read more about K\u00f3dy ch\u00fdb pripojenia a ich rie\u0161enie\">Read more<\/a><\/p>\n","protected":false},"author":400,"featured_media":170354,"parent":330411,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_eb_attr":"","content-type":"","_uag_custom_page_level_css":"","footnotes":""},"class_list":["post-330456","page","type-page","status-publish","has-post-thumbnail"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.3.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>K\u00f3dy ch\u00fdb pripojenia a ich rie\u0161enie - Trydan<\/title>\n<meta name=\"description\" content=\"Zobrazuje sa chyba pripojenia na displeji Trydan? Zozn\u00e1mte sa s v\u00fdznamom chyby a jej rie\u0161en\u00edm | Oblas\u0165 podpory\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/v2charge.com\/sk\/oblas-podpory\/ovladanie-v-konu\/dynamicke-riadenie-v-konu\/kody-ch-b-pripojenia-a-ich-rie-enie\/\" \/>\n<meta property=\"og:locale\" content=\"sk_SK\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"K\u00f3dy ch\u00fdb pripojenia a ich rie\u0161enie - Trydan\" \/>\n<meta property=\"og:description\" content=\"Zobrazuje sa chyba pripojenia na displeji Trydan? Zozn\u00e1mte sa s v\u00fdznamom chyby a jej rie\u0161en\u00edm | Oblas\u0165 podpory\" \/>\n<meta property=\"og:url\" content=\"https:\/\/v2charge.com\/sk\/oblas-podpory\/ovladanie-v-konu\/dynamicke-riadenie-v-konu\/kody-ch-b-pripojenia-a-ich-rie-enie\/\" \/>\n<meta property=\"og:site_name\" content=\"V2C\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/V2C.Charge\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-13T14:45:07+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"675\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@V2C_Charge\" \/>\n<meta name=\"twitter:label1\" content=\"Predpokladan\u00fd \u010das \u010d\u00edtania\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 min\u00fat\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/v2charge.com\/sk\/oblas-podpory\/ovladanie-v-konu\/dynamicke-riadenie-v-konu\/kody-ch-b-pripojenia-a-ich-rie-enie\/\",\"url\":\"https:\/\/v2charge.com\/sk\/oblas-podpory\/ovladanie-v-konu\/dynamicke-riadenie-v-konu\/kody-ch-b-pripojenia-a-ich-rie-enie\/\",\"name\":\"K\u00f3dy ch\u00fdb pripojenia a ich rie\u0161enie - Trydan\",\"isPartOf\":{\"@id\":\"https:\/\/v2charge.com\/sk\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/v2charge.com\/sk\/oblas-podpory\/ovladanie-v-konu\/dynamicke-riadenie-v-konu\/kody-ch-b-pripojenia-a-ich-rie-enie\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/v2charge.com\/sk\/oblas-podpory\/ovladanie-v-konu\/dynamicke-riadenie-v-konu\/kody-ch-b-pripojenia-a-ich-rie-enie\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg\",\"datePublished\":\"2024-10-04T13:39:28+00:00\",\"dateModified\":\"2026-01-13T14:45:07+00:00\",\"description\":\"Zobrazuje sa chyba pripojenia na displeji Trydan? Zozn\u00e1mte sa s v\u00fdznamom chyby a jej rie\u0161en\u00edm | Oblas\u0165 podpory\",\"breadcrumb\":{\"@id\":\"https:\/\/v2charge.com\/sk\/oblas-podpory\/ovladanie-v-konu\/dynamicke-riadenie-v-konu\/kody-ch-b-pripojenia-a-ich-rie-enie\/#breadcrumb\"},\"inLanguage\":\"sk-SK\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/v2charge.com\/sk\/oblas-podpory\/ovladanie-v-konu\/dynamicke-riadenie-v-konu\/kody-ch-b-pripojenia-a-ich-rie-enie\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"sk-SK\",\"@id\":\"https:\/\/v2charge.com\/sk\/oblas-podpory\/ovladanie-v-konu\/dynamicke-riadenie-v-konu\/kody-ch-b-pripojenia-a-ich-rie-enie\/#primaryimage\",\"url\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg\",\"contentUrl\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg\",\"width\":1200,\"height\":675,\"caption\":\"V2C Electric Chargers\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/v2charge.com\/sk\/oblas-podpory\/ovladanie-v-konu\/dynamicke-riadenie-v-konu\/kody-ch-b-pripojenia-a-ich-rie-enie\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"V2C\",\"item\":\"https:\/\/v2charge.com\/sk\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Oblas\u0165 podpory\",\"item\":\"https:\/\/v2charge.com\/sk\/oblas-podpory\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Control de potencia\",\"item\":\"https:\/\/v2charge.com\/sk\/ovladanie-v-konu\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Din\u00e1mico\",\"item\":\"https:\/\/v2charge.com\/sk\/dynamicke-riadenie-v-konu\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"K\u00f3dy ch\u00fdb pripojenia a ich rie\u0161enie\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/v2charge.com\/sk\/#website\",\"url\":\"https:\/\/v2charge.com\/sk\/\",\"name\":\"V2C\",\"description\":\"#CargandoElMa\u00f1ana\",\"publisher\":{\"@id\":\"https:\/\/v2charge.com\/sk\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/v2charge.com\/sk\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"sk-SK\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/v2charge.com\/sk\/#organization\",\"name\":\"V2C\",\"url\":\"https:\/\/v2charge.com\/sk\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"sk-SK\",\"@id\":\"https:\/\/v2charge.com\/sk\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png\",\"contentUrl\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png\",\"width\":984,\"height\":431,\"caption\":\"V2C\"},\"image\":{\"@id\":\"https:\/\/v2charge.com\/sk\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/V2C.Charge\",\"https:\/\/x.com\/V2C_Charge\",\"https:\/\/www.instagram.com\/v2c.charge\/\",\"https:\/\/www.youtube.com\/@V2C\",\"https:\/\/www.linkedin.com\/company\/v2c-chargers\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"K\u00f3dy ch\u00fdb pripojenia a ich rie\u0161enie - Trydan","description":"Zobrazuje sa chyba pripojenia na displeji Trydan? Zozn\u00e1mte sa s v\u00fdznamom chyby a jej rie\u0161en\u00edm | Oblas\u0165 podpory","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/v2charge.com\/sk\/oblas-podpory\/ovladanie-v-konu\/dynamicke-riadenie-v-konu\/kody-ch-b-pripojenia-a-ich-rie-enie\/","og_locale":"sk_SK","og_type":"article","og_title":"K\u00f3dy ch\u00fdb pripojenia a ich rie\u0161enie - Trydan","og_description":"Zobrazuje sa chyba pripojenia na displeji Trydan? Zozn\u00e1mte sa s v\u00fdznamom chyby a jej rie\u0161en\u00edm | Oblas\u0165 podpory","og_url":"https:\/\/v2charge.com\/sk\/oblas-podpory\/ovladanie-v-konu\/dynamicke-riadenie-v-konu\/kody-ch-b-pripojenia-a-ich-rie-enie\/","og_site_name":"V2C","article_publisher":"https:\/\/www.facebook.com\/V2C.Charge","article_modified_time":"2026-01-13T14:45:07+00:00","og_image":[{"width":1200,"height":675,"url":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@V2C_Charge","twitter_misc":{"Predpokladan\u00fd \u010das \u010d\u00edtania":"6 min\u00fat"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/v2charge.com\/sk\/oblas-podpory\/ovladanie-v-konu\/dynamicke-riadenie-v-konu\/kody-ch-b-pripojenia-a-ich-rie-enie\/","url":"https:\/\/v2charge.com\/sk\/oblas-podpory\/ovladanie-v-konu\/dynamicke-riadenie-v-konu\/kody-ch-b-pripojenia-a-ich-rie-enie\/","name":"K\u00f3dy ch\u00fdb pripojenia a ich rie\u0161enie - Trydan","isPartOf":{"@id":"https:\/\/v2charge.com\/sk\/#website"},"primaryImageOfPage":{"@id":"https:\/\/v2charge.com\/sk\/oblas-podpory\/ovladanie-v-konu\/dynamicke-riadenie-v-konu\/kody-ch-b-pripojenia-a-ich-rie-enie\/#primaryimage"},"image":{"@id":"https:\/\/v2charge.com\/sk\/oblas-podpory\/ovladanie-v-konu\/dynamicke-riadenie-v-konu\/kody-ch-b-pripojenia-a-ich-rie-enie\/#primaryimage"},"thumbnailUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","datePublished":"2024-10-04T13:39:28+00:00","dateModified":"2026-01-13T14:45:07+00:00","description":"Zobrazuje sa chyba pripojenia na displeji Trydan? Zozn\u00e1mte sa s v\u00fdznamom chyby a jej rie\u0161en\u00edm | Oblas\u0165 podpory","breadcrumb":{"@id":"https:\/\/v2charge.com\/sk\/oblas-podpory\/ovladanie-v-konu\/dynamicke-riadenie-v-konu\/kody-ch-b-pripojenia-a-ich-rie-enie\/#breadcrumb"},"inLanguage":"sk-SK","potentialAction":[{"@type":"ReadAction","target":["https:\/\/v2charge.com\/sk\/oblas-podpory\/ovladanie-v-konu\/dynamicke-riadenie-v-konu\/kody-ch-b-pripojenia-a-ich-rie-enie\/"]}]},{"@type":"ImageObject","inLanguage":"sk-SK","@id":"https:\/\/v2charge.com\/sk\/oblas-podpory\/ovladanie-v-konu\/dynamicke-riadenie-v-konu\/kody-ch-b-pripojenia-a-ich-rie-enie\/#primaryimage","url":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","contentUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","width":1200,"height":675,"caption":"V2C Electric Chargers"},{"@type":"BreadcrumbList","@id":"https:\/\/v2charge.com\/sk\/oblas-podpory\/ovladanie-v-konu\/dynamicke-riadenie-v-konu\/kody-ch-b-pripojenia-a-ich-rie-enie\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"V2C","item":"https:\/\/v2charge.com\/sk\/"},{"@type":"ListItem","position":2,"name":"Oblas\u0165 podpory","item":"https:\/\/v2charge.com\/sk\/oblas-podpory\/"},{"@type":"ListItem","position":3,"name":"Control de potencia","item":"https:\/\/v2charge.com\/sk\/ovladanie-v-konu\/"},{"@type":"ListItem","position":4,"name":"Din\u00e1mico","item":"https:\/\/v2charge.com\/sk\/dynamicke-riadenie-v-konu\/"},{"@type":"ListItem","position":5,"name":"K\u00f3dy ch\u00fdb pripojenia a ich rie\u0161enie"}]},{"@type":"WebSite","@id":"https:\/\/v2charge.com\/sk\/#website","url":"https:\/\/v2charge.com\/sk\/","name":"V2C","description":"#CargandoElMa\u00f1ana","publisher":{"@id":"https:\/\/v2charge.com\/sk\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/v2charge.com\/sk\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"sk-SK"},{"@type":"Organization","@id":"https:\/\/v2charge.com\/sk\/#organization","name":"V2C","url":"https:\/\/v2charge.com\/sk\/","logo":{"@type":"ImageObject","inLanguage":"sk-SK","@id":"https:\/\/v2charge.com\/sk\/#\/schema\/logo\/image\/","url":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png","contentUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png","width":984,"height":431,"caption":"V2C"},"image":{"@id":"https:\/\/v2charge.com\/sk\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/V2C.Charge","https:\/\/x.com\/V2C_Charge","https:\/\/www.instagram.com\/v2c.charge\/","https:\/\/www.youtube.com\/@V2C","https:\/\/www.linkedin.com\/company\/v2c-chargers\/"]}]}},"uagb_featured_image_src":{"full":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"thumbnail":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-150x150.jpg",150,150,true],"medium":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-300x169.jpg",300,169,true],"medium_large":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-768x432.jpg",768,432,true],"large":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-1024x576.jpg",1024,576,true],"gs-tiny":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",50,28,false],"xl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxxxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxxxxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"1536x1536":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"2048x2048":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false]},"uagb_author_info":{"display_name":"V2C","author_link":"https:\/\/v2charge.com\/sk\/author\/marketing\/"},"uagb_comment_info":0,"uagb_excerpt":"K\u00f3dy ch\u00fdb pripojenia a ich rie\u0161enie Ak pri aktiv\u00e1cii dynamick\u00e9ho riadenia v\u00fdkonu na nab\u00edja\u010dke Trydan alebo Trydan Pro d\u00f4jde k chybe, na displeji nab\u00edja\u010dky sa zobraz\u00ed k\u00f3d zodpovedaj\u00faci chybe. Rie\u0161enia pre chyby uveden\u00e9 ni\u017e\u0161ie sa vz\u0165ahuj\u00fa na verziu 1.6.18 alebo vy\u0161\u0161ie. V pr\u00edpade, \u017ee m\u00e1te ni\u017e\u0161iu verziu, aktualizujte nab\u00edja\u010dku Trydan a znova skontrolujte nasleduj\u00faci zoznam.&hellip;","_links":{"self":[{"href":"https:\/\/v2charge.com\/sk\/wp-json\/wp\/v2\/pages\/330456","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/v2charge.com\/sk\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/v2charge.com\/sk\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/v2charge.com\/sk\/wp-json\/wp\/v2\/users\/400"}],"replies":[{"embeddable":true,"href":"https:\/\/v2charge.com\/sk\/wp-json\/wp\/v2\/comments?post=330456"}],"version-history":[{"count":0,"href":"https:\/\/v2charge.com\/sk\/wp-json\/wp\/v2\/pages\/330456\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/v2charge.com\/sk\/wp-json\/wp\/v2\/pages\/330411"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/v2charge.com\/sk\/wp-json\/wp\/v2\/media\/170354"}],"wp:attachment":[{"href":"https:\/\/v2charge.com\/sk\/wp-json\/wp\/v2\/media?parent=330456"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}