{"id":312889,"date":"2024-10-04T15:39:28","date_gmt":"2024-10-04T13:39:28","guid":{"rendered":""},"modified":"2026-01-13T16:45:07","modified_gmt":"2026-01-13T14:45:07","slug":"koda-napak-pri-povezovanju-in-njihova-re-itev","status":"publish","type":"page","link":"https:\/\/v2charge.com\/sl\/podro-je-podpore\/nadzor-mo-i\/dinami-no-upravljanje-mo-i\/koda-napak-pri-povezovanju-in-njihova-re-itev\/","title":{"rendered":"Koda napak pri povezovanju in njihova re\u0161itev"},"content":{"rendered":"\n<div class=\"wp-block-uagb-container uagb-block-9d828d1c alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><div class=\"yoast-breadcrumbs\"><span><span><a href=\"https:\/\/v2charge.com\/sl\/\">V2C<\/a><\/span> \u00bb <span><a href=\"https:\/\/v2charge.com\/sl\/dinami-no-upravljanje-mo-i\/\">Din\u00e1mico<\/a><\/span> \u00bb <span class=\"breadcrumb_last\" aria-current=\"page\">Koda napak pri povezovanju in njihova re\u0161itev<\/span><\/span><\/div>\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-be8360a4\"><h1 class=\"uagb-heading-text\">Kode napak pri povezovanju in njihova re\u0161itev<\/h1><\/div>\n\n<p>\u010ce se ob aktivaciji dinami\u010dnega nadzora mo\u010di na polnilniku Trydan ali Trydan Pro pojavi napaka, se na zaslonu polnilnika prika\u017ee <strong>koda, ki ustreza napaki<\/strong>.<br><br>Re\u0161itve za napake, navedene spodaj, ustrezajo <strong>razli\u010dici 1.6.18 ali vi\u0161ji<\/strong>. V primeru, da imate ni\u017ejo razli\u010dico, <a href=\"https:\/\/v2charge.com\/sl\/soporte\/trydan\/actualizar-ultima-version\/\"><strong>posodobite polnilnik Trydan<\/strong><\/a> in ponovno preverite naslednji seznam.<\/p><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-f83ba0fb alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-9d537ef2\">\n<div class=\"wp-block-uagb-container uagb-block-1021f2c1\">\n<div class=\"wp-block-uagb-image aligncenter uagb-block-f5b78000 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-center\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png ,https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png 780w, https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png\" alt=\"\" class=\"uag-image-125013\" width=\"50\" height=\"50\" title=\"\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-a8351972\"><div class=\"wp-block-uagb-advanced-heading uagb-block-fdcb9def\"><p class=\"uagb-heading-text\"><strong>POMEMBNA OPOMBA:<\/strong> ti napaki izhajajo iz napake pri komunikaciji med Trydanom in inverterjem ali merilnikom ter omejujejo polnjenje va\u0161ega vozila na minimum. Nekateri se lahko pojavijo, ko je integracija neposredna z inverterjem, bodisi preko komunikacije Modbus ali RS485.<br><strong>Obvezno se posvetujte z re\u0161itvijo napake, ki se prika\u017ee na zaslonu. <\/strong>\u010ce napaka vztraja, jo sporo\u010dite na\u0161emu oddelku za tehni\u010dno podporo in onemogo\u010dite dinami\u010dno upravljanje polnjenja, da boste lahko polnili z dolo\u010deno fiksno intenzivnostjo.<\/p><\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-separator uagb-block-b0f92113\"><div class=\"wp-block-uagb-separator__inner\" style=\"--my-background-image:\"><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-4d0c1e2a\">\n<div class=\"wp-block-uagb-container uagb-block-195968cb\"><table style=\"border:none;\">\n    <tr style=\"border:none;\">\n        <th style=\"border:none;\">NAPAKA<\/th>\n        <th style=\"border:none;\"><u>00<\/u><\/th>\n        <th style=\"border:none;\"><u>000<\/u><\/th>\n    <\/tr>\n    <tr style=\"border:none;\">\n        <td style=\"border:none;\"><\/td>\n        <td style=\"border:none;\"><center>A<\/center><\/td>\n        <td style=\"border:none;\"><center>B<\/center><\/td>\n    <\/tr>\n<\/table><\/div>\n<\/div>\n\n\n<p>Prvi <strong>dva \u0161tevila<\/strong> ozna\u010data merilnik ali inverter, ki ga uporabljamo. Pomembno je izbrati pravega, ko nastavljamo dinami\u010dno upravljanje mo\u010di, in preveriti, da je pravilen v primeru napake.<\/p>\n\n\n<div class=\"wp-block-uagb-container uagb-block-8616beaf\">\n<div class=\"wp-block-uagb-container uagb-block-9f8097ef\"><p><strong>Napake &#8211; A<\/strong><\/p><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-4816f3c8\"><p><strong>00<\/strong>  Medidor Shelly<br><strong>01<\/strong>  V2C ControlBox<br><strong>02<\/strong>  Medidor V2C 1.0<br><strong>03<\/strong>  Povezava na inverter Huawei<br><strong>04<\/strong>  Povezava na inverter Solax<br><strong>05<\/strong>  Povezava na inverter Kostal<br><strong>06<\/strong>  Povezava na inverter Fronius<br><strong>07<\/strong>  Povezava na inverter Ingeteam<br><strong>08  <\/strong>Povezava na medidor Wibeee<br><strong>09<\/strong>  Povezava na medidor Victron<br><strong>10<\/strong>  Povezava na inverter SolarEdge<br><strong>11<\/strong>  Uporaba protokola MQTT<\/p><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-8ef7ba8e\"><p><strong>12<\/strong> Povezava na inverter Goodwe<br><strong>13<\/strong> Povezava na inverter SAJ \/ GreenHeiss<br><strong>14<\/strong> Povezava na inverter Solis<br><strong>15<\/strong> Povezava na merilnik Chint DDSU666<br><strong>16<\/strong> Povezava na merilnik Eastron<br><strong>17<\/strong> Povezava na merilnik Phoneix Contact<br><strong>18<\/strong> Povezava na merilnik Carlo Gavazzi<br><strong>19<\/strong> Povezava na merilnik SMA<br><strong>20<\/strong> Povezava na inverter Deye \/ Turbo Energy<br><strong>21<\/strong> Povezava na inverter ENPHASE<br><strong>22<\/strong> Povezava na merilnik WiFi P1 Meter<br><strong>23 <\/strong>Povezava preko Modbus<br><strong>25<\/strong> Povezava na merilnik Shelly Pro<br><strong>26<\/strong> Povezava na inverter Growatt<br><strong>27<\/strong> Povezava na inverter Sungrow<br><strong>28 <\/strong>Povezava na merilnik LINKY LORA<br><strong>94<\/strong> Izven obmo\u010dja meritev Car<br><strong>95<\/strong> Izven obmo\u010dja meritev Grid<br><strong>96<\/strong> Izven obmo\u010dja meritev House<br><strong>97<\/strong> Izven obmo\u010dja meritev Battery<br><strong>98 <\/strong>Izven obmo\u010dja meritev FV<br><strong>99 <\/strong>Povezava med dvema polnilnikoma Trydan v na\u010dinu uravnote\u017eenja obremenitve<\/p><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-separator uagb-block-b634b355\"><div class=\"wp-block-uagb-separator__inner\" style=\"--my-background-image:\"><\/div><\/div>\n\n\n<p><strong>Napake &#8211; B<\/strong><\/p>\n\n\n<div class=\"wp-block-uagb-container uagb-block-842d9744\">\n<div class=\"wp-block-uagb-container uagb-block-f682e240\"><p><strong>000<\/strong>&nbsp;Mere so izven razpona.<br><strong><strong>Preveri<\/strong><\/strong>:<br>&#8211; Ali ima polnilec notranji merilnik. Preveri znamko, ali je enofazni ali trifazni, in ga nastavi na polnilcu preko tipkovnice, ali pa kontaktiraj podporo za oddaljeno nastavitev, \u010de je polnilec povezan.<br>&#8211; Pravilna fizi\u010dna povezava merilnika s plo\u0161\u010do mo\u010di.<br><br><strong><strong>001<\/strong> <\/strong>Za naprave Goodwe s protokolom UDP<strong><br><strong>Preveri<\/strong><\/strong>:<br>&#8211; Tako inverter kot polnilec sta povezana z internetom.<br>&#8211; IP inverterja je nepravilno dodeljena v e-Chargerju.<br><br><strong>002<\/strong> Za merilnik V2C 1.0 in 2.0: podatki prihajajo po\u0161kodovani.<br><strong>Preveri<\/strong>:<br>&#8211; Pravilno krimpanje RJ-45 konektorja na obeh koncih.<br>&#8211; Pravilna nastavitev dinami\u010dnega nadzora z izbranim merilnikom, ki ustreza namestitvi.<br><br><strong>003<\/strong> Mo\u017ena motnja v signalu V2C ControlBox.<br><strong>Preveri:<br><\/strong>&#8211; Pravilno krimpanje RJ-45 konektorja na obeh koncih.<br>&#8211; Pravilna nastavitev dinami\u010dnega nadzora z izbranim merilnikom, ki ustreza namestitvi.<br><br><strong>004<\/strong> Trydan je odklopljen od WiFi in posku\u0161a ponovno povezati, merilnik WiFi pa uporablja to tehnologijo WiFi za povezovanje.<br><strong>Preveri<\/strong>:<br>&#8211; Pravilna povezava obeh naprav na isto WiFi omre\u017eje stranke (ne na polnilec)<br>&#8211; Da je mo\u010d signala optimalna ali izbolj\u0161ati povezavo WiFi s ponavljalnikom, na katerega sta obe napravi povezani.<br><br><strong>005<\/strong> V2C ControlBox, povezan preko RJ-45, ne odgovarja.<br><strong>Preveri<\/strong>:<br>&#8211; Pravilno krimpanje RJ-45 konektorja na obeh koncih.<br><br><strong>006<\/strong> Izvr\u0161i se HTTP zahteva in pride do napake pri povezavi (Shelly, Solax, Kostal Piko, Enphase, P1 Meter, SAJ [Son\u010dni podatki], Wibeee). Napaka pri poskusu povezave s stre\u017enikom Modbus TCP (Huawei, Kostal Plenticore, Fronius, Ingeteam, SMA Sunny, SolarEdge, Victron).<br><strong>Preveri<\/strong>:<br>&#8211; Pravilna povezava obeh naprav na isto WiFi omre\u017eje stranke (ne na polnilec).<br>&#8211; IP inverterja je nepravilno dodeljena v e-Chargerju.<br>&#8211; Da je mo\u010d signala optimalna ali izbolj\u0161ati povezavo WiFi s ponavljalnikom, na katerega sta obe napravi povezani.<br>&#8211; Pravilna nastavitev inverterja glede na parametre komunikacije s Trydanom.<\/p><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-71147356\"><p><strong>007<\/strong> Samodejna iskanje Shelly ni na\u0161lo nobene naprave.<br><strong>Preverite<\/strong>:<br>&#8211; Preklop na fiksni IP naslov Shelly na polnilniku Trydan.<br>&#8211; Pravilna povezava obeh naprav na isto WiFi omre\u017eje stranke (ne na polnilnik).<br><br><strong>008<\/strong> Izbran je merilec s tehnologijo WiFi in Trydan se nikoli ni povezal na konfigurirano WiFi omre\u017eje.<br><strong>Preverite<\/strong>:<br>&#8211; Pravilna povezava obeh naprav na isto WiFi omre\u017eje stranke z zadostnim signalom (ne na polnilnik).<br><br><strong>009 <\/strong>Prejeta je Timeout zahteva za merilec.<br><strong>Preverite<\/strong>:<br>&#8211; Pravilno krimpanje RJ-45 konektorja na obeh koncih.<br>&#8211; Pravilna nastavitev inverterja glede na parametre komunikacije s Trydan.<br>&#8211; V primeru inverterja ali WiFi merilca pravilna povezava obeh naprav na isto WiFi omre\u017eje stranke z zadostnim signalom (ne na polnilnik).<br>&#8211; IP naslov inverterja in pravilno nastavitev v dinami\u010dnem nadzoru mo\u010di Trydan.<br>&#8211; Inverter Solax: Pravilna razli\u010dica Pocket WiFi V2.033.20 (povezava za prenos vklju\u010dena v priro\u010dniku).<br><br><strong>010<\/strong> Prejeta je informacija o ne povezani sponki na kanalu, ki je potreben<br>(Mono + FV sponka 1 ali 4, Trifazni sponke 1, 2 ali 3)<br><strong>Preverite<\/strong>:<br>&#8211; Pravilna namestitev sponk na fazah, ki so navedene v pravilnem na\u010drtu namestitve v vsakem primeru.<\/p><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-00168f44\">\n<div class=\"wp-block-uagb-container uagb-block-c837e147\">\n<div class=\"wp-block-uagb-image aligncenter uagb-block-ded0ddba wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-center\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png ,https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png 780w, https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2023\/11\/icon-important.png\" alt=\"\" class=\"uag-image-125013\" width=\"50\" height=\"50\" title=\"\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-421a53a1\"><div class=\"wp-block-uagb-advanced-heading uagb-block-ab21f8f7\"><p class=\"uagb-heading-text\"><strong>POZOR:<\/strong> \u010ce je <strong>koda napake ve\u010dja od 011<\/strong>, so <strong>to napake, ki so opredeljene v protokolu MODBUS RTU ali TCP. Samo za usposobljeno osebje.<\/strong> Lahko ustvarite zahtevo v Tehni\u010dnem podpori in kontaktirali vas bomo \u010dim prej.<\/p><\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-a889f73f\">\n<div class=\"wp-block-uagb-container uagb-block-3ced5973\"><p><strong>021 <\/strong> NELEGALNA_FUNKCIJA<br><strong>022<\/strong> NELEGALNA_NASLOV_DATA<br><strong>023<\/strong> NELEGALNA_VREDNOST_DATA<br><strong>024<\/strong> OKVARA_STRE\u017dNIKA_DEVICES<br><strong>025<\/strong> POTRDITEV<br><strong>026<\/strong> STRE\u017dNIK_DEVICE_ZASEDEN<br><strong>027<\/strong> NEGATIVNA_POTRDITEV<br><strong>028<\/strong> SPOMINSKA_PARITETA_NAPAKA<br><strong>030<\/strong> GATEWAY_POT_UNAVAIL<br><strong>031<\/strong> GATEWAY_CILJ_BREZ_ODGOVORA<br><strong>032<\/strong> STRE\u017dNIK_RTU_NEAKTIVEN<br><strong>244<\/strong> \u010cASOVNA_MEJA<br><strong>245<\/strong> NEVELJAVEN_STRE\u017dNIK<br><strong>246<\/strong> CRC_NAPAKA<br><strong>247<\/strong> FC_NEKONFORMNOST<br><strong>248<\/strong> NEKONFORMNOST_ID_STRE\u017dNIKA<br><strong>249<\/strong> NAPAKA_DOL\u017dINA_PAKETA<\/p><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-70caf82a\"><p><strong>250<\/strong>  PARAMETER_COUNT_ERROR<br><strong>251<\/strong>  PARAMETER_LIMIT_ERROR<br><strong>252<\/strong>  REQUEST_QUEUE_FULL<br><strong>253<\/strong>  ILLEGAL_IP_OR_PORT<br><strong>254<\/strong>  IP_CONNECTION_FAILED<br><strong>255<\/strong>  TCP_HEAD_MISMATCH<br><strong>256<\/strong>  EMPTY_MESSAGE<br><strong>275 <\/strong> UNDEFINED_ERROR<\/p><\/div>\n<\/div>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-c6f38013 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><div class=\"wp-block-uagb-advanced-heading uagb-block-6963d70c\"><h2 class=\"uagb-heading-text\"><strong>Potrebujete tehni\u010dno podporo?<\/strong><\/h2><\/div>\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-408243eb\"><p class=\"uagb-heading-text\">Takoj re\u0161ite svojo te\u017eavo preko na\u0161ega klepeta z umetno inteligenco. \u010ce te\u017eave ne re\u0161imo, ustvarite zahtevo v Tehni\u010dnem podporni centru in \u010dim prej se bomo obrnili na vas, da vam ponudimo najbolj\u0161o re\u0161itev.<\/p><\/div>\n\n<div class=\"wp-block-uagb-info-box uagb-block-12e3cf1c uagb-infobox__content-wrap  uagb-infobox-icon-left uagb-infobox-left uagb-infobox-image-valign-top wp-block-uagb-info-box--has-margin ai-chatbot-button\"><div class=\"uagb-infobox-margin-wrapper\"><div class=\"uagb-ifb-image-content\"><img decoding=\"async\" src=\"https:\/\/v2charge.com\/wp-content\/uploads\/2026\/01\/support-ai-chatbot.png\" alt=\"\" width=\"20\" height=\"19\" loading=\"lazy\"\/><\/div><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><\/div><div class=\"uagb-ifb-button-wrapper wp-block-button\"><a href=\"https:\/\/v2charge.com\/sl\/v2c-support-web\/\" class=\"uagb-infobox-cta-link wp-block-button__link\" target=\"_blank\" rel=\"noopener noreferrer\" onclick=\"return true;\"><span class=\"uagb-inline-editing\">Vpra\u0161ajte na\u0161o IA klepetalnico<\/span><\/a><\/div><\/div><\/div><\/div>\n\n\n<div class=\"wp-block-uagb-buttons uagb-buttons__outer-wrap uagb-btn__default-btn uagb-btn-tablet__default-btn uagb-btn-mobile__default-btn uagb-block-ba1e67d1\"><div class=\"uagb-buttons__wrap uagb-buttons-layout-wrap \"><div class=\"wp-block-uagb-buttons-child uagb-buttons__outer-wrap uagb-block-23cfb623 wp-block-button\"><div class=\"uagb-button__wrapper\"><a class=\"uagb-buttons-repeater wp-block-button__link\" aria-label=\"\" href=\"https:\/\/v2charge.atlassian.net\/servicedesk\/customer\/portal\/3\" rel=\"follow noopener\" target=\"_blank\" role=\"button\"><div class=\"uagb-button__link\">Kontaktirajte tehni\u010dno podporo<\/div><\/a><\/div><\/div><\/div><\/div>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Kode napak pri povezovanju in njihova re\u0161itev \u010ce se ob aktivaciji dinami\u010dnega nadzora mo\u010di na polnilniku Trydan ali Trydan Pro pojavi napaka, se na zaslonu polnilnika prika\u017ee koda, ki ustreza napaki. Re\u0161itve za napake, navedene spodaj, ustrezajo razli\u010dici 1.6.18 ali vi\u0161ji. V primeru, da imate ni\u017ejo razli\u010dico, posodobite polnilnik Trydan in ponovno preverite naslednji seznam. &#8230; <a title=\"Koda napak pri povezovanju in njihova re\u0161itev\" class=\"read-more\" href=\"https:\/\/v2charge.com\/sl\/podro-je-podpore\/nadzor-mo-i\/dinami-no-upravljanje-mo-i\/koda-napak-pri-povezovanju-in-njihova-re-itev\/\" aria-label=\"Read more about Koda napak pri povezovanju in njihova re\u0161itev\">Read more<\/a><\/p>\n","protected":false},"author":400,"featured_media":170354,"parent":312843,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_eb_attr":"","content-type":"","_uag_custom_page_level_css":"","footnotes":""},"class_list":["post-312889","page","type-page","status-publish","has-post-thumbnail"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.3.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Koda napak pri povezovanju in njihova re\u0161itev - Trydan<\/title>\n<meta name=\"description\" content=\"Ali se na zaslonu Trydan prika\u017ee napaka pri povezavi? Spoznajte pomen napake in njeno re\u0161itev | Podpora\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/v2charge.com\/sl\/podro-je-podpore\/nadzor-mo-i\/dinami-no-upravljanje-mo-i\/koda-napak-pri-povezovanju-in-njihova-re-itev\/\" \/>\n<meta property=\"og:locale\" content=\"sl_SI\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Koda napak pri povezovanju in njihova re\u0161itev - Trydan\" \/>\n<meta property=\"og:description\" content=\"Ali se na zaslonu Trydan prika\u017ee napaka pri povezavi? Spoznajte pomen napake in njeno re\u0161itev | Podpora\" \/>\n<meta property=\"og:url\" content=\"https:\/\/v2charge.com\/sl\/podro-je-podpore\/nadzor-mo-i\/dinami-no-upravljanje-mo-i\/koda-napak-pri-povezovanju-in-njihova-re-itev\/\" \/>\n<meta property=\"og:site_name\" content=\"V2C\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/V2C.Charge\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-13T14:45:07+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"675\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@V2C_Charge\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 minut\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/v2charge.com\/sl\/podro-je-podpore\/nadzor-mo-i\/dinami-no-upravljanje-mo-i\/koda-napak-pri-povezovanju-in-njihova-re-itev\/\",\"url\":\"https:\/\/v2charge.com\/sl\/podro-je-podpore\/nadzor-mo-i\/dinami-no-upravljanje-mo-i\/koda-napak-pri-povezovanju-in-njihova-re-itev\/\",\"name\":\"Koda napak pri povezovanju in njihova re\u0161itev - Trydan\",\"isPartOf\":{\"@id\":\"https:\/\/v2charge.com\/sl\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/v2charge.com\/sl\/podro-je-podpore\/nadzor-mo-i\/dinami-no-upravljanje-mo-i\/koda-napak-pri-povezovanju-in-njihova-re-itev\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/v2charge.com\/sl\/podro-je-podpore\/nadzor-mo-i\/dinami-no-upravljanje-mo-i\/koda-napak-pri-povezovanju-in-njihova-re-itev\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg\",\"datePublished\":\"2024-10-04T13:39:28+00:00\",\"dateModified\":\"2026-01-13T14:45:07+00:00\",\"description\":\"Ali se na zaslonu Trydan prika\u017ee napaka pri povezavi? Spoznajte pomen napake in njeno re\u0161itev | Podpora\",\"breadcrumb\":{\"@id\":\"https:\/\/v2charge.com\/sl\/podro-je-podpore\/nadzor-mo-i\/dinami-no-upravljanje-mo-i\/koda-napak-pri-povezovanju-in-njihova-re-itev\/#breadcrumb\"},\"inLanguage\":\"sl-SI\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/v2charge.com\/sl\/podro-je-podpore\/nadzor-mo-i\/dinami-no-upravljanje-mo-i\/koda-napak-pri-povezovanju-in-njihova-re-itev\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"sl-SI\",\"@id\":\"https:\/\/v2charge.com\/sl\/podro-je-podpore\/nadzor-mo-i\/dinami-no-upravljanje-mo-i\/koda-napak-pri-povezovanju-in-njihova-re-itev\/#primaryimage\",\"url\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg\",\"contentUrl\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg\",\"width\":1200,\"height\":675,\"caption\":\"V2C Electric Chargers\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/v2charge.com\/sl\/podro-je-podpore\/nadzor-mo-i\/dinami-no-upravljanje-mo-i\/koda-napak-pri-povezovanju-in-njihova-re-itev\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"V2C\",\"item\":\"https:\/\/v2charge.com\/sl\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Din\u00e1mico\",\"item\":\"https:\/\/v2charge.com\/sl\/dinami-no-upravljanje-mo-i\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Koda napak pri povezovanju in njihova re\u0161itev\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/v2charge.com\/sl\/#website\",\"url\":\"https:\/\/v2charge.com\/sl\/\",\"name\":\"V2C\",\"description\":\"#CargandoElMa\u00f1ana\",\"publisher\":{\"@id\":\"https:\/\/v2charge.com\/sl\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/v2charge.com\/sl\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"sl-SI\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/v2charge.com\/sl\/#organization\",\"name\":\"V2C\",\"url\":\"https:\/\/v2charge.com\/sl\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"sl-SI\",\"@id\":\"https:\/\/v2charge.com\/sl\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png\",\"contentUrl\":\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png\",\"width\":984,\"height\":431,\"caption\":\"V2C\"},\"image\":{\"@id\":\"https:\/\/v2charge.com\/sl\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/V2C.Charge\",\"https:\/\/x.com\/V2C_Charge\",\"https:\/\/www.instagram.com\/v2c.charge\/\",\"https:\/\/www.youtube.com\/@V2C\",\"https:\/\/www.linkedin.com\/company\/v2c-chargers\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Koda napak pri povezovanju in njihova re\u0161itev - Trydan","description":"Ali se na zaslonu Trydan prika\u017ee napaka pri povezavi? Spoznajte pomen napake in njeno re\u0161itev | Podpora","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/v2charge.com\/sl\/podro-je-podpore\/nadzor-mo-i\/dinami-no-upravljanje-mo-i\/koda-napak-pri-povezovanju-in-njihova-re-itev\/","og_locale":"sl_SI","og_type":"article","og_title":"Koda napak pri povezovanju in njihova re\u0161itev - Trydan","og_description":"Ali se na zaslonu Trydan prika\u017ee napaka pri povezavi? Spoznajte pomen napake in njeno re\u0161itev | Podpora","og_url":"https:\/\/v2charge.com\/sl\/podro-je-podpore\/nadzor-mo-i\/dinami-no-upravljanje-mo-i\/koda-napak-pri-povezovanju-in-njihova-re-itev\/","og_site_name":"V2C","article_publisher":"https:\/\/www.facebook.com\/V2C.Charge","article_modified_time":"2026-01-13T14:45:07+00:00","og_image":[{"width":1200,"height":675,"url":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@V2C_Charge","twitter_misc":{"Est. reading time":"6 minut"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/v2charge.com\/sl\/podro-je-podpore\/nadzor-mo-i\/dinami-no-upravljanje-mo-i\/koda-napak-pri-povezovanju-in-njihova-re-itev\/","url":"https:\/\/v2charge.com\/sl\/podro-je-podpore\/nadzor-mo-i\/dinami-no-upravljanje-mo-i\/koda-napak-pri-povezovanju-in-njihova-re-itev\/","name":"Koda napak pri povezovanju in njihova re\u0161itev - Trydan","isPartOf":{"@id":"https:\/\/v2charge.com\/sl\/#website"},"primaryImageOfPage":{"@id":"https:\/\/v2charge.com\/sl\/podro-je-podpore\/nadzor-mo-i\/dinami-no-upravljanje-mo-i\/koda-napak-pri-povezovanju-in-njihova-re-itev\/#primaryimage"},"image":{"@id":"https:\/\/v2charge.com\/sl\/podro-je-podpore\/nadzor-mo-i\/dinami-no-upravljanje-mo-i\/koda-napak-pri-povezovanju-in-njihova-re-itev\/#primaryimage"},"thumbnailUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","datePublished":"2024-10-04T13:39:28+00:00","dateModified":"2026-01-13T14:45:07+00:00","description":"Ali se na zaslonu Trydan prika\u017ee napaka pri povezavi? Spoznajte pomen napake in njeno re\u0161itev | Podpora","breadcrumb":{"@id":"https:\/\/v2charge.com\/sl\/podro-je-podpore\/nadzor-mo-i\/dinami-no-upravljanje-mo-i\/koda-napak-pri-povezovanju-in-njihova-re-itev\/#breadcrumb"},"inLanguage":"sl-SI","potentialAction":[{"@type":"ReadAction","target":["https:\/\/v2charge.com\/sl\/podro-je-podpore\/nadzor-mo-i\/dinami-no-upravljanje-mo-i\/koda-napak-pri-povezovanju-in-njihova-re-itev\/"]}]},{"@type":"ImageObject","inLanguage":"sl-SI","@id":"https:\/\/v2charge.com\/sl\/podro-je-podpore\/nadzor-mo-i\/dinami-no-upravljanje-mo-i\/koda-napak-pri-povezovanju-in-njihova-re-itev\/#primaryimage","url":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","contentUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","width":1200,"height":675,"caption":"V2C Electric Chargers"},{"@type":"BreadcrumbList","@id":"https:\/\/v2charge.com\/sl\/podro-je-podpore\/nadzor-mo-i\/dinami-no-upravljanje-mo-i\/koda-napak-pri-povezovanju-in-njihova-re-itev\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"V2C","item":"https:\/\/v2charge.com\/sl\/"},{"@type":"ListItem","position":2,"name":"Din\u00e1mico","item":"https:\/\/v2charge.com\/sl\/dinami-no-upravljanje-mo-i\/"},{"@type":"ListItem","position":3,"name":"Koda napak pri povezovanju in njihova re\u0161itev"}]},{"@type":"WebSite","@id":"https:\/\/v2charge.com\/sl\/#website","url":"https:\/\/v2charge.com\/sl\/","name":"V2C","description":"#CargandoElMa\u00f1ana","publisher":{"@id":"https:\/\/v2charge.com\/sl\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/v2charge.com\/sl\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"sl-SI"},{"@type":"Organization","@id":"https:\/\/v2charge.com\/sl\/#organization","name":"V2C","url":"https:\/\/v2charge.com\/sl\/","logo":{"@type":"ImageObject","inLanguage":"sl-SI","@id":"https:\/\/v2charge.com\/sl\/#\/schema\/logo\/image\/","url":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png","contentUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png","width":984,"height":431,"caption":"V2C"},"image":{"@id":"https:\/\/v2charge.com\/sl\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/V2C.Charge","https:\/\/x.com\/V2C_Charge","https:\/\/www.instagram.com\/v2c.charge\/","https:\/\/www.youtube.com\/@V2C","https:\/\/www.linkedin.com\/company\/v2c-chargers\/"]}]}},"uagb_featured_image_src":{"full":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"thumbnail":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-150x150.jpg",150,150,true],"medium":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-300x169.jpg",300,169,true],"medium_large":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-768x432.jpg",768,432,true],"large":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-1024x576.jpg",1024,576,true],"gs-tiny":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",50,28,false],"xl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxxxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxxxxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"1536x1536":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"2048x2048":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false]},"uagb_author_info":{"display_name":"V2C","author_link":"https:\/\/v2charge.com\/sl\/author\/marketing\/"},"uagb_comment_info":0,"uagb_excerpt":"Kode napak pri povezovanju in njihova re\u0161itev \u010ce se ob aktivaciji dinami\u010dnega nadzora mo\u010di na polnilniku Trydan ali Trydan Pro pojavi napaka, se na zaslonu polnilnika prika\u017ee koda, ki ustreza napaki. Re\u0161itve za napake, navedene spodaj, ustrezajo razli\u010dici 1.6.18 ali vi\u0161ji. V primeru, da imate ni\u017ejo razli\u010dico, posodobite polnilnik Trydan in ponovno preverite naslednji seznam.&hellip;","_links":{"self":[{"href":"https:\/\/v2charge.com\/sl\/wp-json\/wp\/v2\/pages\/312889","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/v2charge.com\/sl\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/v2charge.com\/sl\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/v2charge.com\/sl\/wp-json\/wp\/v2\/users\/400"}],"replies":[{"embeddable":true,"href":"https:\/\/v2charge.com\/sl\/wp-json\/wp\/v2\/comments?post=312889"}],"version-history":[{"count":0,"href":"https:\/\/v2charge.com\/sl\/wp-json\/wp\/v2\/pages\/312889\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/v2charge.com\/sl\/wp-json\/wp\/v2\/pages\/312843"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/v2charge.com\/sl\/wp-json\/wp\/v2\/media\/170354"}],"wp:attachment":[{"href":"https:\/\/v2charge.com\/sl\/wp-json\/wp\/v2\/media?parent=312889"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}