{"id":394658,"date":"2023-08-08T15:09:10","date_gmt":"2023-08-08T15:09:10","guid":{"rendered":""},"modified":"2025-01-16T17:30:24","modified_gmt":"2025-01-16T15:30:24","slug":"dynamic-power-control-switching-errors-trydan","status":"publish","type":"page","link":"https:\/\/v2charge.com\/sv\/dynamic-power-control-switching-errors-trydan\/","title":{"rendered":"Fel vid v\u00e4xling av dynamisk effektstyrning i Trydan"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Om Dynamic Power Control \u00e4r aktiverad vid Trydan-laddningspunkten och ett fel uppst\u00e5r visas en kod som motsvarar felet p\u00e5 laddarens display (dessa indikeringar visas endast fr\u00e5n och med version 1.6.18).<\/p>\n\n<p class=\"wp-block-paragraph\">VIKTIGT: dessa fel \u00e4r inte driftsfel. Om laddpunkten inte \u00e4r korrekt ansluten till m\u00e4taren kommer den att ladda med minimal effekt.<\/p>\n\n<p class=\"wp-block-paragraph\">Det f\u00f6rsta numret \u00e4r ett tv\u00e5siffrigt nummer och anger vilken slav vi anv\u00e4nder. Det \u00e4r anv\u00e4ndbart f\u00f6r att kontrollera att vi har valt r\u00e4tt slav. Kom ih\u00e5g att slaven v\u00e4ljs i den f\u00f6rsta konfigurationen och \u00e4r den m\u00e4tare som vi kommer att anv\u00e4nda f\u00f6r att utf\u00f6ra funktionerna.<\/p>\n\n\n<ul class=\"wp-block-list\"><li>00 \u2013 Shelly-m\u00e4tare<\/li>\n\n<li>01 &#8211; V2C Meter Slave 2.0<\/li>\n\n<li>02 \u2013 Meter Slave V2C 1.0<\/li>\n\n<li>03 &#8211; Anslutning av Huawei-v\u00e4xelriktare<\/li>\n\n<li>04 \u2013 Anslutning till Solax-v\u00e4xelriktare<\/li>\n\n<li>05 \u2013 Anslutning till Kostal-v\u00e4xelriktare<\/li>\n\n<li>06 &#8211; Anslutning till Fronius-v\u00e4xelriktare<\/li>\n\n<li>07 &#8211; Anslutning till Ingeteam-v\u00e4xelriktare<\/li>\n\n<li>08 &#8211; Anslutning till Wibeee-m\u00e4tare<\/li>\n\n<li>09 &#8211; Anslutning till Victron-m\u00e4tare<\/li>\n\n<li>10 \u2013 Anslutning till SolarEdge-v\u00e4xelriktare<\/li>\n\n<li>11 \u2013 Anv\u00e4ndning av MQTT-protokollet<\/li>\n\n<li>12 \u2013 Anslutning av Goodwe-v\u00e4xelriktare<\/li>\n\n<li>13 \u2013 Anslutning till SAJ-\/GreenHeiss-v\u00e4xelriktare<\/li>\n\n<li>14 \u2013 Anslutning av Solis-v\u00e4xelriktare<\/li>\n\n<li>15 \u2013 Anslutning till Chint-m\u00e4tare DDSU666<\/li>\n\n<li>16 \u2013 Anslutning av Eastron-m\u00e4tare<\/li>\n\n<li>17 \u2013 Anslutning till Phoenix Contact-m\u00e4tare<\/li>\n\n<li>18 \u2013 anslutning av Carlo Gavazzi-m\u00e4tare<\/li>\n\n<li>19 \u2013 Anslutning till SMA-m\u00e4tare<\/li>\n\n<li>20 \u2013 Anslutning till Deye-\/Turbo Energy-v\u00e4xelriktare<\/li>\n\n<li>21 \u2013 Anslutning till ENPHASE-v\u00e4xelriktare<\/li>\n\n<li>22 \u2013 Anslutning till Wifi-m\u00e4tare P1 Meter<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n<p class=\"wp-block-paragraph\"><strong>OM DET ST\u00c5R ANSLUTNINGSFEL BETYDER DET ATT KABELN \u00c4R FELAKTIGT ANSLUTEN. VI TAR INTE EMOT N\u00c5GON INFORMATION.<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\">Efter siffran ovan f\u00f6ljer ytterligare tre siffror. Deras betydelse f\u00f6rklaras nedan:<\/p>\n\n\n<ul class=\"wp-block-list\"><li>001 \u2013 Fel som endast g\u00e4ller Goodwe-utrustning med UDP-protokoll.<\/li>\n\n<li>002 \u2013 Fel endast p\u00e5 slav 1 och 2: ramarna kommer fram korrupta. M\u00f6jligen fel p\u00e5 slavm\u00e4taren. St\u00f6rningar i signalen.<\/li>\n\n<li>004 \u2013 Den f\u00f6rs\u00f6ker \u00e5teransluta till WiFi och slaven anv\u00e4nder denna WiFi-teknik f\u00f6r att ansluta.<\/li>\n\n<li>005 \u2013 Den tr\u00e5dbundna RTU-slaven svarar inte.<\/li>\n\n<li>006 \u2013 HTTP-beg\u00e4ran skickades men anslutningen misslyckades (Shelly, Solax, Kostal Piko, Enphase, P1 Meter, SAJ [Solar Data], Wibeee). Det gick inte att ansluta till Modbus TCP-servern (Huawei, Kostal Plenticore, Fronius, Ingeteam, SMA Sunny, SolarEdge, Victron).<\/li>\n\n<li>007 \u2013 Den automatiska Shelly-s\u00f6kningen hittade ingen enhet (vi rekommenderar att ange Shellys fasta IP-adress i Trydan-laddaren).<\/li>\n\n<li>008 \u2013 En WiFi-kompatibel slav har valts och Trydan ansl\u00f6t aldrig till det konfigurerade WiFi-n\u00e4tverket.<\/li>\n\n<li>009 \u2013 En timeout f\u00f6r beg\u00e4ran till slaven har tagits emot.<\/li>\n\n<li>010 \u2013 Data tas emot fr\u00e5n en str\u00f6mt\u00e5ng som inte \u00e4r ansluten till en obligatorisk kanal (enfas + PV-str\u00f6mt\u00e5ng 1 eller 4, trefasstr\u00f6mt\u00e5ng 1, 2 eller 3).<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n<p class=\"wp-block-paragraph\">Om felkoden \u00e4r h\u00f6gre \u00e4n 11 g\u00e4ller det fel som definieras i protokollet MODBUS RTU eller TCP. Endast f\u00f6r beh\u00f6rig personal.<\/p>\n\n\n<ul class=\"wp-block-list\"><li>021 &#8211; LLEGAL_FUNCTION&nbsp;<\/li>\n\n<li>022 \u2013 ILLEGAL_DATA_ADDRESS&nbsp;&nbsp;<\/li>\n\n<li>023 &#8211; OTILL\u00c5TET DATAV\u00c4RDE&nbsp;&nbsp;<\/li>\n\n<li>024 &#8211; SERVER_DEVICE_FAILURE<\/li>\n\n<li>025 \u2013 BEKR\u00c4FTA&nbsp;<\/li>\n\n<li>026 &#8211; SERVER_DEVICE_BUSY&nbsp;<\/li>\n\n<li>027 \u2013 NEGATIVE_ACKNOWLEDGE&nbsp;&nbsp;&nbsp;<\/li>\n\n<li>028 &#8211; MEMORY_PARITY_ERROR&nbsp;<\/li>\n\n<li>030 \u2013 GATEWAY_PATH_UNAVAIL&nbsp;<\/li>\n\n<li>031 &#8211; GATEWAY_TARGET_NO_RESP <\/li>\n\n<li>032 &#8211; SERVER_RTU_INACTIVE&nbsp;<\/li>\n\n<li>244 &#8211; TIDS\u00d6VERSKRIDNING<\/li>\n\n<li>245 &#8211; INVALID_SERVER<\/li>\n\n<li>246 &#8211; CRC_ERROR&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; <\/li>\n\n<li>247 \u2013 FC_MISMATCH<\/li>\n\n<li>248 \u2013 SERVER_ID_MISMATCH&nbsp;&nbsp;&nbsp;<\/li>\n\n<li>249 \u2013 PAKETL\u00c4NGDSFEL&nbsp;&nbsp;&nbsp;<\/li>\n\n<li>250 \u2013 PARAMETER_COUNT_ERROR&nbsp; <\/li>\n\n<li>251 &#8211; PARAMETER_LIMIT_ERROR&nbsp; <\/li>\n\n<li>252 \u2013 BEG\u00c4RAN_K\u00d6_FULL&nbsp;&nbsp;&nbsp;<\/li>\n\n<li>253&nbsp;&#8211; ILLEGAL_IP_OR_PORT&nbsp;&nbsp;&nbsp;&nbsp; <\/li>\n\n<li>254 &#8211; IP_CONNECTION_FAILED&nbsp;&nbsp; <\/li>\n\n<li>255 \u2013 TCP_HEAD_MISMATCH&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; <\/li>\n\n<li>256 &#8211; EMPTY_MESSAGE&nbsp;<\/li>\n\n<li>275 \u2013 ODEFINIERAT_FEL&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;  <\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Om Dynamic Power Control \u00e4r aktiverad vid Trydan-laddningspunkten och ett fel uppst\u00e5r visas en kod som motsvarar felet p\u00e5 laddarens display (dessa indikeringar visas endast fr\u00e5n och med version 1.6.18). VIKTIGT: dessa fel \u00e4r inte driftsfel. Om laddpunkten inte \u00e4r korrekt ansluten till m\u00e4taren kommer den att ladda med minimal effekt. Det f\u00f6rsta numret \u00e4r &#8230; <a title=\"Fel vid v\u00e4xling av dynamisk effektstyrning i Trydan\" class=\"read-more\" href=\"https:\/\/v2charge.com\/sv\/dynamic-power-control-switching-errors-trydan\/\" aria-label=\"L\u00e4s mer om Fel vid v\u00e4xling av dynamisk effektstyrning i Trydan\">L\u00e4s mer<\/a><\/p>\n","protected":false},"author":1,"featured_media":170346,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_eb_attr":"","content-type":"","_uag_custom_page_level_css":"","footnotes":""},"class_list":["post-394658","page","type-page","status-publish","has-post-thumbnail"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Fel p\u00e5 Trydan med dynamisk effektstyrning | V2C<\/title>\n<meta name=\"description\" content=\"Identifiera de olika m\u00f6jliga anslutningsfelen f\u00f6r Trydan med dynamisk effektstyrning f\u00f6r att hitta en l\u00f6sning.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/v2charge.com\/sv\/dynamic-power-control-switching-errors-trydan\/\" \/>\n<meta property=\"og:locale\" content=\"sv_SE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Fel p\u00e5 Trydan med dynamisk effektstyrning | V2C\" \/>\n<meta property=\"og:description\" content=\"Identifiera de olika m\u00f6jliga anslutningsfelen f\u00f6r Trydan med dynamisk effektstyrning f\u00f6r att hitta en l\u00f6sning.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/v2charge.com\/sv\/dynamic-power-control-switching-errors-trydan\/\" \/>\n<meta property=\"og:site_name\" content=\"V2C\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/V2C.Charge\" \/>\n<meta property=\"article:modified_time\" content=\"2025-01-16T15:30:24+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"675\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@V2C_Charge\" \/>\n<meta name=\"twitter:label1\" content=\"Ber\u00e4knad l\u00e4stid\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minuter\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/v2charge.com\\\/sv\\\/dynamic-power-control-switching-errors-trydan\\\/\",\"url\":\"https:\\\/\\\/v2charge.com\\\/sv\\\/dynamic-power-control-switching-errors-trydan\\\/\",\"name\":\"Fel p\u00e5 Trydan med dynamisk effektstyrning | V2C\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/v2charge.com\\\/sv\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/v2charge.com\\\/sv\\\/dynamic-power-control-switching-errors-trydan\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/v2charge.com\\\/sv\\\/dynamic-power-control-switching-errors-trydan\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/v2charge.com\\\/wp-content\\\/uploads\\\/2024\\\/07\\\/v2c-electric-chargers.jpg\",\"datePublished\":\"2023-08-08T15:09:10+00:00\",\"dateModified\":\"2025-01-16T15:30:24+00:00\",\"description\":\"Identifiera de olika m\u00f6jliga anslutningsfelen f\u00f6r Trydan med dynamisk effektstyrning f\u00f6r att hitta en l\u00f6sning.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/v2charge.com\\\/sv\\\/dynamic-power-control-switching-errors-trydan\\\/#breadcrumb\"},\"inLanguage\":\"sv-SE\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/v2charge.com\\\/sv\\\/dynamic-power-control-switching-errors-trydan\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"sv-SE\",\"@id\":\"https:\\\/\\\/v2charge.com\\\/sv\\\/dynamic-power-control-switching-errors-trydan\\\/#primaryimage\",\"url\":\"https:\\\/\\\/v2charge.com\\\/wp-content\\\/uploads\\\/2024\\\/07\\\/v2c-electric-chargers.jpg\",\"contentUrl\":\"https:\\\/\\\/v2charge.com\\\/wp-content\\\/uploads\\\/2024\\\/07\\\/v2c-electric-chargers.jpg\",\"width\":1200,\"height\":675,\"caption\":\"V2C Electric Chargers\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/v2charge.com\\\/sv\\\/dynamic-power-control-switching-errors-trydan\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"V2C\",\"item\":\"https:\\\/\\\/v2charge.com\\\/sv\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Fel vid v\u00e4xling av dynamisk effektstyrning i Trydan\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/v2charge.com\\\/sv\\\/#website\",\"url\":\"https:\\\/\\\/v2charge.com\\\/sv\\\/\",\"name\":\"V2C\",\"description\":\"#CargandoElMa\u00f1ana\",\"publisher\":{\"@id\":\"https:\\\/\\\/v2charge.com\\\/sv\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/v2charge.com\\\/sv\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"sv-SE\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/v2charge.com\\\/sv\\\/#organization\",\"name\":\"V2C\",\"url\":\"https:\\\/\\\/v2charge.com\\\/sv\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"sv-SE\",\"@id\":\"https:\\\/\\\/v2charge.com\\\/sv\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/v2charge.com\\\/wp-content\\\/uploads\\\/2024\\\/11\\\/cropped-v2c-charge-logo-menu.png\",\"contentUrl\":\"https:\\\/\\\/v2charge.com\\\/wp-content\\\/uploads\\\/2024\\\/11\\\/cropped-v2c-charge-logo-menu.png\",\"width\":984,\"height\":431,\"caption\":\"V2C\"},\"image\":{\"@id\":\"https:\\\/\\\/v2charge.com\\\/sv\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/V2C.Charge\",\"https:\\\/\\\/x.com\\\/V2C_Charge\",\"https:\\\/\\\/www.instagram.com\\\/v2c.charge\\\/\",\"https:\\\/\\\/www.youtube.com\\\/@V2C\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/v2c-chargers\\\/\"],\"contactPoint\":[{\"@type\":\"ContactPoint\",\"contactType\":\"customer support\",\"telephone\":\"+34960654554\",\"email\":\"info@v2charge.com\",\"availableLanguage\":[\"Spanish\",\"English\",\"Portuguese\",\"French\"]},{\"@type\":\"ContactPoint\",\"contactType\":\"sales\",\"telephone\":\"+34960654554\",\"email\":\"info@v2charge.com\",\"availableLanguage\":[\"Spanish\",\"English\"]}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Fel p\u00e5 Trydan med dynamisk effektstyrning | V2C","description":"Identifiera de olika m\u00f6jliga anslutningsfelen f\u00f6r Trydan med dynamisk effektstyrning f\u00f6r att hitta en l\u00f6sning.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/v2charge.com\/sv\/dynamic-power-control-switching-errors-trydan\/","og_locale":"sv_SE","og_type":"article","og_title":"Fel p\u00e5 Trydan med dynamisk effektstyrning | V2C","og_description":"Identifiera de olika m\u00f6jliga anslutningsfelen f\u00f6r Trydan med dynamisk effektstyrning f\u00f6r att hitta en l\u00f6sning.","og_url":"https:\/\/v2charge.com\/sv\/dynamic-power-control-switching-errors-trydan\/","og_site_name":"V2C","article_publisher":"https:\/\/www.facebook.com\/V2C.Charge","article_modified_time":"2025-01-16T15:30:24+00:00","og_image":[{"width":1200,"height":675,"url":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@V2C_Charge","twitter_misc":{"Ber\u00e4knad l\u00e4stid":"3 minuter"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/v2charge.com\/sv\/dynamic-power-control-switching-errors-trydan\/","url":"https:\/\/v2charge.com\/sv\/dynamic-power-control-switching-errors-trydan\/","name":"Fel p\u00e5 Trydan med dynamisk effektstyrning | V2C","isPartOf":{"@id":"https:\/\/v2charge.com\/sv\/#website"},"primaryImageOfPage":{"@id":"https:\/\/v2charge.com\/sv\/dynamic-power-control-switching-errors-trydan\/#primaryimage"},"image":{"@id":"https:\/\/v2charge.com\/sv\/dynamic-power-control-switching-errors-trydan\/#primaryimage"},"thumbnailUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","datePublished":"2023-08-08T15:09:10+00:00","dateModified":"2025-01-16T15:30:24+00:00","description":"Identifiera de olika m\u00f6jliga anslutningsfelen f\u00f6r Trydan med dynamisk effektstyrning f\u00f6r att hitta en l\u00f6sning.","breadcrumb":{"@id":"https:\/\/v2charge.com\/sv\/dynamic-power-control-switching-errors-trydan\/#breadcrumb"},"inLanguage":"sv-SE","potentialAction":[{"@type":"ReadAction","target":["https:\/\/v2charge.com\/sv\/dynamic-power-control-switching-errors-trydan\/"]}]},{"@type":"ImageObject","inLanguage":"sv-SE","@id":"https:\/\/v2charge.com\/sv\/dynamic-power-control-switching-errors-trydan\/#primaryimage","url":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","contentUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg","width":1200,"height":675,"caption":"V2C Electric Chargers"},{"@type":"BreadcrumbList","@id":"https:\/\/v2charge.com\/sv\/dynamic-power-control-switching-errors-trydan\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"V2C","item":"https:\/\/v2charge.com\/sv\/"},{"@type":"ListItem","position":2,"name":"Fel vid v\u00e4xling av dynamisk effektstyrning i Trydan"}]},{"@type":"WebSite","@id":"https:\/\/v2charge.com\/sv\/#website","url":"https:\/\/v2charge.com\/sv\/","name":"V2C","description":"#CargandoElMa\u00f1ana","publisher":{"@id":"https:\/\/v2charge.com\/sv\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/v2charge.com\/sv\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"sv-SE"},{"@type":"Organization","@id":"https:\/\/v2charge.com\/sv\/#organization","name":"V2C","url":"https:\/\/v2charge.com\/sv\/","logo":{"@type":"ImageObject","inLanguage":"sv-SE","@id":"https:\/\/v2charge.com\/sv\/#\/schema\/logo\/image\/","url":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png","contentUrl":"https:\/\/v2charge.com\/wp-content\/uploads\/2024\/11\/cropped-v2c-charge-logo-menu.png","width":984,"height":431,"caption":"V2C"},"image":{"@id":"https:\/\/v2charge.com\/sv\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/V2C.Charge","https:\/\/x.com\/V2C_Charge","https:\/\/www.instagram.com\/v2c.charge\/","https:\/\/www.youtube.com\/@V2C","https:\/\/www.linkedin.com\/company\/v2c-chargers\/"],"contactPoint":[{"@type":"ContactPoint","contactType":"customer support","telephone":"+34960654554","email":"info@v2charge.com","availableLanguage":["Spanish","English","Portuguese","French"]},{"@type":"ContactPoint","contactType":"sales","telephone":"+34960654554","email":"info@v2charge.com","availableLanguage":["Spanish","English"]}]}]}},"uagb_featured_image_src":{"full":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"thumbnail":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-150x150.jpg",150,150,true],"medium":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-300x169.jpg",300,169,true],"medium_large":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-768x432.jpg",768,432,true],"large":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers-1024x576.jpg",1024,576,true],"gs-tiny":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",50,28,false],"xl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxxxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"xxxxxl":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"1536x1536":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false],"2048x2048":["https:\/\/v2charge.com\/wp-content\/uploads\/2024\/07\/v2c-electric-chargers.jpg",1200,675,false]},"uagb_author_info":{"display_name":"V2C","author_link":"https:\/\/v2charge.com\/sv\/author\/root_k4eu7ki8\/"},"uagb_comment_info":0,"uagb_excerpt":"Om Dynamic Power Control \u00e4r aktiverad vid Trydan-laddningspunkten och ett fel uppst\u00e5r visas en kod som motsvarar felet p\u00e5 laddarens display (dessa indikeringar visas endast fr\u00e5n och med version 1.6.18). VIKTIGT: dessa fel \u00e4r inte driftsfel. Om laddpunkten inte \u00e4r korrekt ansluten till m\u00e4taren kommer den att ladda med minimal effekt. Det f\u00f6rsta numret \u00e4r&hellip;","_links":{"self":[{"href":"https:\/\/v2charge.com\/sv\/wp-json\/wp\/v2\/pages\/394658","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/v2charge.com\/sv\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/v2charge.com\/sv\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/v2charge.com\/sv\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/v2charge.com\/sv\/wp-json\/wp\/v2\/comments?post=394658"}],"version-history":[{"count":0,"href":"https:\/\/v2charge.com\/sv\/wp-json\/wp\/v2\/pages\/394658\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/v2charge.com\/sv\/wp-json\/wp\/v2\/media\/170346"}],"wp:attachment":[{"href":"https:\/\/v2charge.com\/sv\/wp-json\/wp\/v2\/media?parent=394658"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}