Päivitykset
Mikä muuttuu latureidemme ja V2C Cloud -alustan jokaisessa laiteohjelmistoversiossa.
Uusimmat: Denka 1.1.0 · 12 marras 2026
Trydan ja Trydan Pro
Nykyinen versio 2.5.2 · Versioita: 47, ensimmäinen: helmikuu 2022
New inverters (Solplanet/AISWEI, Hoymiles, Huawei without dongle), battery discharge control, unified statistics in mixed three-phase, and cybersecurity improvements in Bluetooth.
- UusiDirect query of OCPP status
- UusiNew Solplanet/AISWEI Inverter
- UusiNew Hoymiles Inverter
- UusiBattery discharge control: GoodWe, SolarEdge
- UusiHuawei inverters direct connection without Dongle
- UusiUnified statistics in mixed three-phase charging (the session is not divided when switching between three-phase and single-phase)
- UusiNew "Unlimited" Wake-up 5 mode available from the LCD
- UusiImprovements in Bluetooth cybersecurity
- ParannusFixes in FV mode + Minimum power
- ParannusOCPP: duplicate BootNotifications are avoided
- ParannusSecurity menu lock during vehicle charging
- ParannusImprovements for Linky-LORA
Aiemmat versiot 46
-
- UusiCompatibility with SigEnergy inverters
- UusiNew model of Ingeteam three-phase inverter (ISS 3PLAY)
- UusiWiFi connection for Deye inverters via Elfin
- UusiExpansion to 105 RFID cards
- UusiPAP/CHAP authentication for 4G connection
- UusiMore stable OCPP connections
- ParannusReading the P1 and Victron meters is more reliable in the event of communication failures.
- ParannusStability of mixed three-phase charging
- ParannusError reporting and diagnostic system
- ParannusImprovement of home battery charging priority in PV charging modes
-
- UusiManagement of home battery discharge in charging profiles
- UusiUnlocking the Trydan by smartphone proximity
- UusiNew models of SofarSolar and Azzurro inverters
- UusiAdded current and voltage per phase in Home Assistant and Modbus API.
- UusiWiFi connection in Deye inverters
- UusiIncrease of up to 80 RFID cards
- UusiBattery compatibility in SolarEdge inverters
- UusiScroll text for long texts
- ParannusOptimization of Ethernet network interface
- ParannusImprovements in the Modbus TCP client
- ParannusImprovements in mixed three-phase charging
- ParannusImprovement of texts in German
- ParannusIncrease the voltage range of the installation from the control panel.
-
- KorjausOCPP password bug
- KorjausProblems connecting to CSMS after restarts
-
- UusiTarget charge kWh
- UusiNew SMA Sunny Boy model
- UusiNew Fronius model with battery
- UusiSelect Modbus API address ID
- UusiNew Deye models
- UusiSofar Solar inverters
- UusiAzzurro inverters
- UusiSelect MID address
- UusiEMMA Huawei
- UusiSecurity Profile 2 OCPP (wss + auth + CA cert)
- UusiPrivate 4G SIMs in OCPP
- UusiOcppFreeMode
- UusiOCPP internal queue messages
- ParannusTime synchronization
- ParannusPower plate measurements 1.0
- ParannusWiFi improvements
- KorjausExclusive mode bug with batteries
- KorjausCoordinate "ContractedPower" and load profiles with HTTP API.
- KorjausImprove RFID errors
- KorjausMixed load bug
- KorjausBug photovoltaic mode + minimum
- KorjausBug statistics without FV via BLE
-
- UusiMIFARE Ultralight RFID cards
- ParannusMore robust OTA update
- KorjausBug management autolock with payments mode
- KorjausBug in payments mode with RFID
-
- ParannusInstallation problem readings
- ParannusImprovement in BYD mode
- KorjausBug with Wibeee inverter
-
- UusiObtain firmware version via Modbus
- UusiGoodWe via Modbus TCP
- UusiOCPP: FirmwareManagement
- UusiAutolock
- UusiNew MID models
- UusiNew wake-up modes
- UusiAllow changing the charging type in HA (single-phase, three-phase, or mixed)
- UusiLinky meter for French meters
- UusiModbus termination resistance
- UusiReading individual properties HTTP API
- UusiTurn off/Turn on logo and LCD from HTTP API
- PäivitettyImprovements in dynamic control
- PäivitettyImprovement in Sungrow inverter measurements
- PäivitettyImprovements in the OTA update
- PäivitettyImprovements in the button panel menu
- PäivitettyNew Deye models
- PäivitettyOCPP: improvement in MeterValues
- PäivitettyOCPP: send StatusNotification "Faulted" with errors and warnings
- PäivitettyOCPP: publish current version
- PäivitettyOCPP: BootNotification timeout
- PäivitettyNew NTP servers
- PäivitettyImproved WI-FI scanning
- PäivitettyImprovement in P1 meter
- PäivitettyImprovement in remote logs
- PäivitettyIoT call limitation per charger
- PäivitettyImprove RAM memory
- PäivitettyStability via Ethernet
- PäivitettyCorrected translations
- KorjausError "Waiting for Power"
- KorjausBug with RFID cards with long names
- KorjausBug when requesting the list of Wi-Fi SSIDs via Bluetooth.
- KorjausImprove statistics via Bluetooth
- KorjausLocal balancing improvements for up to 10 devices
- KorjausBug when sending RFID code in the statistics
- KorjausBug with Exclusive PV mode and batteries
-
- UusiStatic power control is added (only with Trydan consumption).
- UusiMixed charging adapts to European rates.
- UusiPower control programming with phase limits is allowed.
- UusiThe power control adapts to European countries with phase current limits.
- PäivitettyThe power control algorithm has been modified step by step to apply PID modulation.
- PäivitettyThe static power control between sockets or between e-Chargers is improved.
- KorjausThe failure of remote records is avoided when a disconnection occurs.
-
- KorjausBug DTSU666-G meters
-
- ParannusImprovement in Wake Mode
- KorjausFixed bug when changing the port in MQTT.
-
- UusiEcoCharging to schedule charging automatically during the cheapest daylight hours.
- UusiTurning on and off LEDs via Modbus TCP/RTU. Option to adjust and query the intensity of the LEDs and the LCD screen.
- UusiCompatibility with the new Chint DTSU666-G meter model, allowing for broader integration in various installations.
- UusiFirmware update of the V2C ControlBox meter (2.0) via the access point (AP) and the mobile app.
- UusiImprovement in the reading of electrical signals: State F detection implemented, enhancing the system's ability to recognize and respond to different operating conditions.
- UusiImprovement in the reading of electrical signals: The reading of the input PWM signal has been implemented using DMA (Direct Memory Access), enhancing efficiency and reducing processing load.
- UusiOCPP: Detailed reasons for OCPP functions, providing more comprehensive information about the actions taken and facilitating the diagnosis and analysis of events.
- UusiOCPP: The ability to operate in offline modes, allowing the charger to function correctly even without a connection to the server. Pending messages are stored and sent once the connection is restored, ensuring reliable and consistent communication.
- UusiOCPP: New OCPP state machine. Now, the system connects to the OCPP Central Server (CS) and receives most commands, improving interoperability and remote control.
- ParannusReading the power value of the batteries in Goodwe EH and ET inverters.
- ParannusSystem optimization: reduction of RAM usage, improving overall system stability and performance.
- ParannusImprovement in the reading of electrical signals: Enhanced verification for state E, in addition to omitting zero values from the DMA to avoid incorrect readings.
- ParannusImprovement in reading electrical signals: Now the CP (Control Pilot) signal is read using a parallel task, which enhances the accuracy and response of the system when interacting with the electric vehicle.
- ParannusImprovement in the reading of electrical signals: Enhanced stability during this calibration process through the app.
- ParannusOCPP: Host name resolution. Optimization of libraries to improve DNS resolution and the reliability of secure connections via Secure WebSocket (WSS), increasing stability in communication with remote servers.
- ParannusOCPP: Ensuring that all important information reaches the server once the connection is restored through a persistent message queue.
- ParannusOCPP: Status notifications. Improving communication with the central server for sending status notifications.
- KorjausOCPP: Fixed a false card detection alert that appeared when starting the system, avoiding confusion and improving the user experience.
-
- UusiVoltage reading and writing manual for installation for Modbus TCP and HTTP integrations.
- UusiSAJ hybrid inverters
- UusiShelly Pro meters
- UusiInformation on the response /RealtimeData from http at the request of the developer of the official HA integration.
- UusiDirect methods to activate the access point (WiFi AP) and ping a specific IP.
- UusiTopic trydan_v2c_voltage to write the installation voltage via MQTT.
- ParannusLeak detection
- ParannusMemory management to avoid unexpected restarts with OCPP and the deletion of scheduled power profiles.
- ParannusModbus TCP connections of Trydan and Trydan Pro with Huawei, Fronius, Victron, Ingeteam, SolarEdge, Kostal Plenticore, SMA, and SAJ Hybrid in error 252.
- ParannusVisualization of the RFID card authentication process in OCPP
- ParannusThe memory used in JSON and OCPP goes to the SPI RAM.
- KorjausInformation about RFID cards to the OCPP platform standard for compatibility with platforms like E-flux, Monta…
- KorjausCollision between the SPI elements (RFID, Ethernet, and GPIO extender) of Trydan Pro
-
- UusiAdaptation of OCPP to new central systems
- UusiNew Deye models
- ParannusImprovements in the direction detection of the V2C 2.0 control box
- KorjausLEDs blink when there is no connection.
- KorjausBug in Greenheiss hybrid
-
- UusiDeye / Turbo Energy three-phase
- UusiShelly Pro EM and Shelly Pro 3EM (Beta)
- ParannusShow text on bidirectional meters
- ParannusReadings with Fronius and DTSU666
- ParannusReaction times in the leak detector
- ParannusShow Waiting for Charge in Stop mode
- KorjausBug with French language
- KorjausRaise the HTTP server via Ethernet
- KorjausBug in payments
- KorjausRead-only in the OCPP properties
- KorjausSave power segments via Bluetooth on some devices.
- KorjausShelly Portugal measurements
-
- UusiLive Remote Logs
- ParannusShow stop due to dynamic control
- ParannusRestarts due to reconnection attempts
- ParannusQA Protocol
- ParannusVoltage and Temperature Reading Power PCB
- KorjausNaN measurement on some meters
- KorjausError in Home Wizard readings
-
- ParannusPerformance improvement and future compatibility between Trydan and Trydan Pro.
- ParannusImprovements in OCPP protocol
- ParannusImprovements in the QA process
- ParannusImprovement in memory usage
- ParannusMore robust statistics
-
- UusiNetworks with WPA3 security
- UusiNew BLE (NimBLE)
- Uusie-keys via BLE connection
- UusiNew language: Romanian
- UusiEnphase version 7.x.x, Solis with batteries
- UusiAdaptation of the i2c power board
- ParannusAzure library update
- ParannusUpdate of ESP-IDF and Arduino-ESP32 libraries
- ParannusInvestor communication via WiFi connection without Internet
- ParannusImprovement in V2C 2.0 meter refresh rate
- ParannusImprovement in OCPP, adaptation to support disconnections
- ParannusImprovement in key fob detection
- ParannusImproved refresh rate
- ParannusImprovement of values in Huawei, improvement of Chint in Huawei, and end of charge review.
- KorjausModification of Deye/Turbo Energy batteries
- KorjausCustomizable MQTT topics and username/password
- KorjausDisconnection statistics report
- KorjausBLE compatibility of iPhone
- KorjausOperation of V2C 2.0 meter at night
- KorjausAutomatic date and time
- KorjausInteraction with Megane
-
- UusiBug in photovoltaic three-phase mode
- ParannusWiFi recovery routine
-
- UusiMixed three-phase charging available through the physical menu.
- UusiAdded three-phase MID Meter
- UusiInclusion of server ID 2 in SolarEdge inverters
- UusiAdded Modbus registers with the meter measurement.
- UusiHTTP commands added for integration with HA.
- UusiEnphase Envoy Inverter (beta) (versions 5.x.x)
- UusiV2C 2.0 error detection of clamp not connected
- UusiMQTT Slave with user/password authentication and customizable topics (beta)
- ParannusImprovement of the WatchDog to prevent system freezing
- ParannusImprovement of nearby WiFi scanning
- ParannusBluetoothLE service reconnection protocol
- ParannusWiFi optimization IRAM and affinity with the Azure task
- ParannusReconnection protocol in the absence of WiFi
- ParannusFactory reset
- ParannusThe error code and LED interface
- ParannusImproved the Isolated Installation mode and zero feed-in.
- ParannusReduction in cut-off time through dynamic control to 1 min
- ParannusAutomatic detection of time and time zone
- ParannusThe optimization and refactoring of the measurement slaves
- ParannusUnlocking with BLE Tag
- KorjausOccasional LCD freezes
- KorjausFalse positives from the leak detector
- KorjausProblems with the MID Meter
- KorjausLED error during update
- KorjausDefault value for JSON type variables
- KorjausMeasurement at 0 in Deye/TurboEnergy Inverter
- KorjausVisual errors and local balancing address assignment
-
- UusiSolar Discount on Shortcuts
- UusiDeye/TurboEnergy Inverter Beta
- UusiPhoenix Contact meter
- UusiCarlo Gavazzi meter
- ParannusOCPP improvements and tested in MONTA
- ParannusProblems in dynamic control
- ParannusReconnections and WiFi Stability
- KorjausFrozen LCD
-
- UusiIsolated Mode in Photovoltaic Modes
- UusiDutch, Danish, and Valencian
- UusiLeak sensor modes (installer menu)
- UusiMID meter (installer menu)
- UusiNew Ingeteam protocol (Battery Management)
- UusiThree-phase meters DTSU666
- UusiSDM three-phase meters
- ParannusLocal Balancing Protocol and priorities
- ParannusDetection of ports and hosts in OCPP
- ParannusStable version of SMA Sunny Boy
- ParannusPortuguese version of Wibeee
- ParannusFronius measuring home consumption
- KorjausUnexpected locks and unlocks
- KorjausWhite blinking in locked mode removed
- KorjausError selecting the slaves in beta
- KorjausError of SolarEdge three-phase inverters
-
- UusiChanges and improvements in calibration
-
- ParannusCalibration adapted to the new hardware
- KorjausData analysis in Kostal Piko fixed
-
- UusiLocal balancing between Trydans available via WiFi or wired connection.
- UusiSDM-220/320/120 (Tested with the Eastron brand)
- UusiDDSU-666 Meter (Common in Huawei installations)
- UusiSelf-calibrating without the need for a car
- UusiManual hour available
- UusiHTTP requests to manage the logs
- UusiNew Modbus Registers
- UusiGreenheiss inverters
- UusiSAJ inverters
- UusiWired Solis inverters
- UusiResponse time in configurable dynamic control
- ParannusConfigurable installation voltage
- ParannusNew manufacturing process
- ParannusIncluded Shelly three-phase but without FV measurement.
- ParannusCar consumption via MQTT fixed
- ParannusImproved and more intuitive physical menu
- YhteensopivuusBeta models of Goodwe: the battery measurement is canceled.
- KorjausBug in Max and Min Intensity via Modbus fixed.
- KorjausFalse positives in the leak detector fixed
-
- UusiPrevention of conflicts between slaves and the cloud
- KorjausGoodWe conflicts and Azure initialization
- KorjausFix in Shelly with only three-phase.
-
- ParannusPending statistics will be sent only once.
- ParannusShelly 3EM three-phase and modification for Portugal
- KorjausModbus Multiple Readings Hotfix
-
- UusiNew Modbus registers
- UusiRFID reader in alpha version
- UusiSolaX X3 híbrido compatible
- UusiAvailable calibration and shortcuts via WiFi
- ParannusOCPP Improvements
- ParannusImprovement in WiFi scanning
- ParannusImprovement in reconnection routines
- KorjausBluetooth timezone failure
- KorjausError in Trydan synchronization - APP
- KorjausStatic IP configuration in Trydan via WiFi
- KorjausError saving Modbus parameters
-
- UusiNew method for calibrating communication with the car
- UusiBeta version of the GoodWe ET/EH/BT/BH
- ParannusImprovement in the communication analysis with the car
-
- UusiAuto lock after 60 seconds without a car (shortcut)
- UusiModification for Three-Phase Installations in Portugal for V2C 2.0
- UusiKostal Piko is added.
- ParannusReformulation of the Dynamic Control Algorithm
- ParannusImprovement in the refresh rate of Huawei inverters
- ParannusSolarEdge stable (Meter measuring export)
- ParannusStable version of GoodWe
- ParannusDetection of state D and E according to protocol
- ParannusImproved QA process
- KorjausStored in memory after writings via Modbus TCP and RTU
- KorjausBug in the FV measurements and peaks resolved for V2C 2.0
-
- UusiGoodWe in beta version
- UusiCheck the charging status to avoid short charges (Car at 100% or on scheduled charging)
- ParannusMQTT in stable version
- ParannusVictron in stable version
- ParannusImproved connection with Azure
-
- UusiMQTT slave beta version
- ParannusDetection of power direction in Wibeee
- KorjausThe Victron and SolarEdge inverters were bringing down the system.
-
- UusiSolarEdge inverter added (Beta)
- UusiVictron inverter added (Beta)
- UusiAutolock enabled in shortcut (60 s)
- UusiAutomatic time zone detection
- UusiAlternative meter for car consumption (RS485)
- UusiFV Exclusive with configurable variation
- UusiNew Languages (French, Italian, and German)
- KorjausFixed error in minimum power mode.
-
- ParannusImprovements in Dynamic Control with batteries
- ParannusImprovements in Dynamic Control in Three-Phase Installations (Exclusive Mode and Minimum Power)
- KorjausResolved the IP configuration issues for Trydan with WiFi and BLE.
- KorjausResolved the issues with the IP configuration of Shelly BLE.
-
- UusiInclusion of the Wibeee meter
- UusiSlave 2.0 compatible with Type 1 and Type 2 installation
- UusiChange in the established connection blinking
- UusiDetection and measurement of bifacial load
- UusiImprovement in the collection and transmission of charging data
- UusiAlternative Meter Phoenix Contact (ModbusRTU)
- UusiModbusRTU in Trydan (simultaneous slave and master)
- UusiStatic IP configuration in Trydan
- UusiPossibility to select the IP in Shelly
- ParannusInclusion of maximum intensity in OCPP (as a property)
- ParannusImprovement in the reading of Solax inverters
- ParannusInclusion of batteries in Huawei, Ingeteam, and Fronius inverters.
- ParannusModbusRTU and Modbus TCP server in Trydan
- PäivitettyFirst stable version of Ingeteam
- PäivitettyImprovement in the speed of the leak detector
-
- KorjausError solution in manufacturing when saving WiFi
-
- UusiEliminate false communication errors from the slaves.
- UusiSave the first Shelly that Trydan connects to.
- PäivitettyWith dynamic control disabled, maintain intensity after finishProgramedSaveMode.
-
- ParannusImprovement in telemetry recovery in OCPP
- ParannusImprovement in scanning nearby WiFi networks
-
- UusiInternal Azure ping every 15 seconds to detect disconnections.
- UusiSeparate reconnections to avoid crashing the server.
- UusiOCPP adaptation to work with Home Assistant
- ParannusMigration of the I2C for the clock and LCD to native idf
-
- ParannusIncrease maximum binary size in local webServer
- KorjausRecovery of OCPP transactions to prevent telemetry failures
-
- UusiThe configuration of different IDs for Huawei inverters is added.
- ParannusCorrection of the power reading of the house
- KorjausCorrection of the lock due to Payment Mode and OCPP after deactivation of these.
-
- UusiPayment Method (V2C Payments)
- UusiOCPP Protocol
- ParannusImprovement of WiFi and Bluetooth stability and reconnection
- KorjausReconnection improvement in the inverters and fix after the update of the Huawei SUN2000.
-
- KorjausCorrection of the maximum file size for updates on Local Server
-
- UusiList of available WiFi networks from Trydan (for viewing from iPhone and Android)
- ParannusReconnection with V2C Cloud after communication loss
- KorjausCorrected Shelly and Solax routines
-
- UusiShortcuts on the buttons: Lock and Charging Schedule
- UusiLocal Web page for configuring the Trydan accessible via AP or STA WiFi
- UusiAP mode when the configured WiFi is not available
- ParannusImprovement in LED error codes
- ParannusAdaptation for compatibility with Huawei inverters
-
- UusiWe added connectivity with Fronius inverters.
- ParannusImprovements in screen writing and removal of strange characters
- ParannusImprovement in the transmission of statistics via both WiFi and BLE.
-
- UusiError correction x and y
Alva
Nykyinen versio 1.0.4 · Versioita: 5, ensimmäinen: elokuu 2026
Parannuksia latausistunnossa ja BLE-turvallisuudessa
- ParannusLatauksen hallinta
- ParannusParempi BLE-turvallisuus
- KorjausVirhe ajan ja energian näyttämisessä sovelluksessa ja Installer Panelissa
Aiemmat versiot 4
-
- KorjausVirhe Ingeteam-invertterin kanssa
- KorjausVirhe Homewizard P1 -mittarissa
- KorjausVirhe Eastron-mittarin kanssa
- KorjausVirhe GoodWe-invertterin kanssa
-
- UusiYhteys Home Assistant -järjestelmään
- UusiPäivittäisen nollauksen logiikka
- ParannusAvaus avaimenperillä ja RFID:llä
- ParannusPoikkeusten käsittely, watchdog ja virheiden puhdistus
-
- UusiLiittimen tunnistus LED:llä
- ParannusUudelleenkäynnistyslogiikka
- KorjausAikaan liittyvä maksuvirhe korjattu
-
- UusiQA- ja valmistuslogiikka
- ParannusIstuntojen hallinta molemmissa liittimissä
- KorjausPieniä virheitä
Pole Pro
Nykyinen versio 6.1.3 · Versioita: 47, ensimmäinen: toukokuu 2023
Onko sinulla aiempi Pole? Katso sen päivitykset.
- KorjausThe charger no longer hangs when rebooting while shutting down the 4G module or dynamic power control
Aiemmat versiot 46
- 6.1.2KorjausOCPP security event notifications are no longer sent when the connection uses no security profile (profile 0), since some central systems do not support them
-
- KorjausCorrected default APN for Wireless Logic SIM cards in Belgium
-
- UusiAudible buzzer feedback
- UusiSupport for registering multiple RFID cards
- UusiReading of the installation meter over Modbus RS485 on DC chargers
- UusiDynamic power control for DC installations — master and slave units now share and honor the installation power limit
- UusiLive display of actual consumption versus offered current on the charger screen
- UusiOn-screen guidance walks the user through registering an RFID card
- UusiOCPP connection password can now be set from the Cloud and Bluetooth
- UusiOCPP now supports security profiles, encrypted TLS connections and Basic Authentication for the central system
- ParannusLanguage codes standardized to the ISO 639-1 format
- ParannusReduced volume of messages sent to the Cloud
- ParannusTime synchronization with the CSMS no longer floods the system log
- ParannusLog rotation no longer loses history when the disk is full
- ParannusSafer firmware updates
- ParannusMore reliable connectivity with automatic failover between Ethernet and 4G
- ParannusCharges history now loads page by page instead of the whole history at once, for a faster tab
- KorjausMeasurer error message now reads clearly
- KorjausMore accurate meter-reading validation
- KorjausCharge metrics are preserved if a charge is interrupted unexpectedly
- KorjausScreen orientation set in configuration is now applied correctly
- KorjausFree-charge mode could not be disabled from the installer panel
- KorjausDynamic power limit was not applied at tariff/hour boundaries, briefly leaving an installation without a limit
- KorjausResolved random service restarts (crashes) caused by network device discovery
-
- ParannusMore reliable RFID card reading with optimized antenna configuration from first use
- ParannusImproved stability and responsiveness of the charger's web interface
-
- UusiOCPP - Immediate "Preparing" status when receiving a remote start command via OCPP
- UusiWiFi disabled by default on devices without WiFi configured
- ParannusMore reliable RFID card reading with periodic reader reinitialization
- ParannusBetter cable connection detection and RFID timeout handling
- ParannusCDP - More stable network device discovery, preventing unnecessary register/unregister cycles
- ParannusImproved stability when applying configuration changes to the charger
- ParannusAutomatic migration of legacy pending OCPP messages after update
- ParannusImproved network handling when switching between manual and automatic IP configuration
- KorjausPower factor value conversion for Carlo Gavazzi meters
- KorjausImprovements in power measurement accuracy in single-phase or two-phase installations
- KorjausOCPP - Smart Charging profiles with defined duration now applied correctly
- KorjausOCPP - Local authentication cache overflow that could prevent charging sessions from startIing
- KorjausOCPP - OCPP transactions stuck due to unreleased semaphores or null keys
-
- UusiEnhanced web server for accessing and editing charger properties
- UusiVisual improvements to the web server interface
- UusiPersistent price display on screen when the payment system is active
- UusiRefined error reporting to the cloud
- UusiPower loss detection
- UusiWi-Fi disable option from the installer panel
- UusiNew buzzer system implementation for white boards
- ParannusEnhanced RFID calibration with on-screen indicator during the process
- ParannusRFID reader no longer forcibly activates when OCPP or Payments are active; explicit configuration is respected
- ParannusRefined cable connect/disconnect notification on each event when payments are active
- ParannusOptimized RFID card readings
- ParannusOCPP - Improvements to the offline transaction queue
- ParannusInternal connection optimization and overall performance improvements
- KorjausOCPP - Improved measurement value reporting
- KorjausRefined out-of-range measurement error detection
-
- UusiSoftware-level leak detection enable/disable
- ParannusAdjusted cooldown time between charges when a leak is detected
- ParannusOCPP - Improvements to the offline transaction queue
-
- ParannusWhen OCPP is active, we now show on screen when card passed is not registered in central system.
- KorjausAfter update OCPP image and QR is now recovered.
-
- KorjausFixed issue where it didn't allow a remote start if a car is connected but not in an active transaction.
- KorjausFixed issue in setup interface.
- KorjausFixed monophasic Carlo Gavazzi measurer.
- KorjausFixed OCPP issue where it wouldn't charge in connector 2 if connector 1 is charging.
-
- ParannusImproved network features mainly 4G connection.
-
- ParannusImproved OCPP charge handling.
- ParannusEnhanced reliability in the smart charging logic.
- ParannusImproved features when stopping a charge with invalid identifiers.
- ParannusImproved QR configuration for OCPP.
- ParannusImproved error handling when sensors or communication components fail.
- ParannusBetter log management to prevent the device’s storage from filling up.
- ParannusImproved USB connection features.
- ParannusImproved RFID calibration and detection display.
- ParannusImproved features related to Bluetooth.
- ParannusImproved dynamic power control allowing charge at minimum intensity if master is not detected.
-
- UusiManual timezone setting is now available – The user will be able to configure the timezone even if automatic detection is disabled
- UusiCreated a contingency page in case app is not running
- UusiAdded Italian option for screen
- UusiAdded default payment QR to pay without app
- UusiAdded new OCPP personalization options - The user can now set 2 QR codes on the screen
- ParannusImproved updater
- ParannusImproved network connections
- ParannusImproved OCPP meter values
- ParannusImproved discovering devices when dynamic control is active
- ParannusImproved user interface when updates are in progress
- ParannusLocal load balancing is now implemented as dynamic control based specific conditions
- ParannusImproved Bluetooth connection
- ParannusImproved 4g connections robustness
- ParannusImproved STM32 lock timings
- ParannusImproved OCPP now allows external intensity limits
- ParannusImproved data consumption
- KorjausWhen locking a connector while charging, it now sends end charge telemetry correctly
- KorjausFixed dynamic control issues
- KorjausFixed Carlo Gavazzi power meter
- KorjausFixed OCPP LMS, diagnostics, and charging profile clearing
-
- UusiAdded shared library
- UusiTimezone can be set manually
- UusiTime is now synced with Central System if OCPP is active
- ParannusImproved version/update manager
- ParannusImproved megabyte conversion of Network Monitor
- ParannusObtaining timezone now doesn't need to have correct time by using only http urls
- ParannusMobile usb device name is now obtained dynamically since more usb ports might be used due to TPV
- KorjausFixed power control issues
- KorjausFixed that when locking connector during a charge it now ends correctly
- KorjausRecalculate reboot time when changing time with ble
- KorjausWe now show on screen when non registered RFID is passed while OCPP is active
- KorjausFixed OCPP freemode rfid issues
- KorjausDuplicate StatusNotifications are removed from offline queue
- KorjausFixed "infinite" OCPP offline queue issue
-
- UusiAPN can now be set manually
- ParannusWe now show on screen different wifi images depending on how strong signal is to let know the user how good the connection is
- ParannusGeneral OCPP improvements: we check connection to CS instead of internet for local functioning, we notify a real value now when there's a stop transaction due to power loss, fixed edge cases where connectivity is lost, new ocpp key MaxEVCurrentOffered implemented which limits charge with key instead of smart charging handler, safety mechanisms for ocpp to be more robust
- ParannusIn 4g, increased rssi range for "excellent" so that it indicates correctly when the reception is good
- ParannusImproved data consumption
- ParannusImproved robustness of update
- PäivitettyAccess point time increased to 15 minutes
- KorjausHandled issues when SSID has whitespace
-
- KorjausAccess point improvements.
- KorjausFixed QA issues.
-
- UusiNew direct method to obtain additional information for Smart Charging.
- UusiFixed random reboot time.
- ParannusFixed unset RFID.
- ParannusFixed Unknown measurer and made distinction between Unknown measurer and wrongly configured measurer.
- ParannusOCPP Free mode can be toggled through OCPP keys.
- PäivitettyFixed BLE connection with iphone and fixed bluetooth communication error that appeared on app.
- PäivitettyNetwork improvements. No interface resets performed at boot which improves bootup time. Network changes now don't require reboot. When changing WIFI settings or ip ethernet settings, it connects after setting it instead of rebooting.
- KorjausFixed issue where things on screen were missing in one connector chargers.
- KorjausFixed time/timezone issue caused when the date is off by a few days.
- KorjausNew property added to toggle if vehicle should be able to charge even though measurers aren't working ( Only works when OCPP, payments or dynamic control isn't enabled ).
-
- UusiReflect on screen when charge is paused.
- UusiMade reboot time random.
- KorjausIncreased SAS token time to live of azure.
-
- UusiChanges made to reduce network usage that can be toggled on or off.
- UusiFixed case where config is corrupted or missing and would give trouble at startup.
- UusiWe now send dead letter if cpu gets too hot and cpu temperature is now logged.
- ParannusFixed OCPP inverted measurer error.
- ParannusAdded mechanism to disable or enable Wifi and bluetooth.
- ParannusWe now report information regarding which type of connection to the internet the e-charger has.
- PäivitettyChanged led colors. Switched State A (now white) and State B (now green) colors.
- KorjausFixed set threshold values and neopixel leds of Stm32. We can now also obtain control pilot value from Stm32.
- KorjausOCPP ConnectionTimeOut value can now be changed on the fly.
- KorjausWe now report iccid of sim card is connected. If sim is connected but we can't obtain iccid, we send dead letter.
- KorjausFixed log download of http interface.
-
- UusiLTE signal is now reflected correctly instead of always showing great signal.
- ParannusFixed wathdog reboot after doing hard reset.
-
- UusiAdded dynamic photovoltaic.
- UusiAdded dead letters: measurer fails and kernel error.
- UusiProperty "wifi_info" is now reported.
- UusiProperty "wifi_static" can be set through ble.
- UusiWe can now obtain statistics through direct method.
- UusiAdded individual log level for each type of logger.
- UusiAdded neopixel led type for stm32.
- UusiWe can now set threshold values with stm32 and get control pilot value if debug log of "Stm32" is activated.
- ParannusImprovements in dynamic control, fabrication, QA, Azure, OCPP, config handling, 4g, access point and stm32.
- ParannusWe now obtain timezone through url.
- ParannusRemoved raspbian logo and desktop during boot and added V2C logo.
- ParannusChanged default language after fabrication from english to spanish.
- PäivitettyGeneral bug fixes.
- KorjausWhen downgrading we ensure that version we downgrade to is compatible.
-
- UusiFixed property "ocpp" change bug.
- ParannusProperties "powerweekday", "powerweekend" and "phase_map" can be changed through bluetooth.
- ParannusChanged configuration handling to differentiate internally and externally set variables so that externally set or obtained variables are handled accordingly following the property schemas.
- KorjausWe now report wifi_static with static ip configuration.
- KorjausStatistics are now saved locally.
-
- ParannusMeasurer fails are now registered with modbusrtumeasurer.
- ParannusScreen font bigger for small title.
- KorjausValidate configuration with schemas during loading.
-
- UusiOCPP authorize can now function by connector.
- UusiOCPP WSS connection.
- UusiFixed OCPP parent id tag bug.
- UusiOCPP meter values now work for 3 phases.
- ParannusFixed error 3 not appearing on screen.
- ParannusFixed energy by hour bug.
- ParannusChanged measurer reading approach for faster reads.
- ParannusWith dynamic balancing we now show used and available power in frontend.
-
- ParannusWe show dynamic balancing information on screen.
- ParannusSimplified handling of configuration.
- ParannusImproved dynamic balancing.
-
- ParannusCharger won't reboot if car is in state B and OCPP or Payments is active.
- ParannusWhen car changes from state C to B, charge information will persist on screen.
- ParannusCurrent state charge now reports errors.
- ParannusAdded configuration property validation.
- KorjausDirect method to obtain dynamic balancing information.
- KorjausGeneral dynamic balancing improvements.
- KorjausOCPP improvements.
-
- KorjausChanged remaining set_basic_unreported_config to set_basic_config.
-
- UusiFix dynamic control bug, powerbytram is not being updated.
- UusiFixed bug where whitelist of reported items wasn't being applied and properties weren't being stored in database.
- ParannusRemoved non-repetitive logger.
- ParannusChanged access point interface to change apn, with manual mode or mobile operator mode.
- PäivitettyRefactored config charge box. Removed BASIC_UNREPORTED and created whitelist of properties to report.
- PäivitettyPhase map is now not applied to installation meters.
- KorjausFixed payment bug where a charge couldn't be started properly if charge was started with the hose unlocked.
- KorjausFix bug with power being zero, dynamic control failing when there are no connectors.
- 3.1.8PäivitettyForce WIFI and bluetooth GPIO pins for compute module 4 to work.
- 3.1.7PäivitettyForce 4g GPIO pins for compute module 4 to work.
-
- ParannusWhen we detect that measurers aren't working, we send an unblock command in case there's a charge and the charger has lost power.
- ParannusCreate section BASIC_UNREPORTED for properties that are used but we don't want to report.
- ParannusLocked value has persistance when measurers fail.
- KorjausWhen we don't receive petitions from chromium we now press enter and Ctrl+F5 if there's anything we need to accept.
-
- KorjausChanging WIFI configuration with bluetooth now reboots the charge point.
-
- ParannusFixed configuration file so that software works with compute module 3 and 4.
- ParannusChanged reboot logic. It will now reboot if there's a car connected but charge is not allowed.
- KorjausChanged payments qr code.
- KorjausWe can change log level with property.
-
- KorjausMeter values fixed. We now send wh instead of kwh.
-
- UusiPause is now reset when it goes back to state A.
- UusiShow measurer error as "Error 3" on connector. Behaviour is that connector is locked until it's fixed.
- UusiSet wire connected again.
- ParannusFixed general network errors. Improved access point and wifi connectivity.
- KorjausFixed error where timezone wasn't set correctly so time appeared incorrectly.
- KorjausFixed payment_max_mode timeout bug.
-
- UusiFixed power, it was shown in W and is now in Kw.
- ParannusChange timezone automatically.
- KorjausAdded triphasic phoenix contact measurer.
- PoistettuFixed removal of grey notification update.
-
- UusiWhenever there's an action that provokes rebooting, it will show on screen that it's going to reboot and the cause.
- UusiScreen orientation can now be set and depending on parameter.
- UusiAdded error message 1 and 2.
- UusiBluetooth patch so that bluetooth initialization takes less time.
- UusiCreated patch system. System level changes will be applied with this system.
- ParannusMeasurer refactoring.
- ParannusImei obtention improved.
- ParannusInitial version of bluetooth finished: Obtain properties change basic properties, program charge, reboot, add rfid and change wifi.
- ParannusBoot improvements. "Page not found" isn't shown anymore. Boot is faster. There's a gif indicating that system is starting.
- ParannusObsolete properties are now deleted automatically so that they aren't reported.
- PäivitettyRFID can now function with payments. If RFID is enabled with payments, registered cards will be able to start charges. If RFID is disabled with payments, no card will be able to start a charge.
- KorjausLimited number of messages we can send to iothub.
- KorjausIn OCPP, fixed sending of meter values. Now sending in wh and not in kwh.
- KorjausBoot patch so that GPIO pin initialization takes less time.
- KorjausMonophasic measurer Eastron SDM220 implemented.
- KorjausImproved robustness on all direct methods.
- KorjausFixed bug where it didn't reconnect properly to iothub when it disconnected.
- KorjausCreated direct method to put a QR code on the OCPP screen.
- PoistettuRemoved wire_connected event telemetry.
- 3.0.9KorjausFixed ocpp meter value Energy.Active.Import, when measurer is flipped.
-
- PäivitettyFixed error where e-Charger couldn't obtain dns when connected with WIFI.
- KorjausFixed local load balancing when one connector was charging. Now when one connector is charging, it will charge at the set intensity.
- 3.0.7KorjausFixed ocpp Remote Start Transaction and Remote Stop Transaction.
- 3.0.6KorjausFixed error that ocurred in ocpp where it didn't clear properly the idtag when finishing a transaction.
-
- PäivitettyChanged access point ip from 192.168.44.1 to 192.168.4.1
- PäivitettyWe now report the charger's state instead of the requested vehicle state.
- PäivitettyChanged access point master password.
- KorjausFixed websocket connection issue with nuitka compilation.
-
- ParannusImproved update logs.
- 3.0.3UusiMoved Version from center to right side and added V. before the version number.
- 3.0.2ParannusSTM will now detect SPI bus communication errors and will automatically reset.
-
- UusiScreen now shows when RFID card is registered.
- UusiTop bar now shows version and if access point is accessible.
- UusiAccess point interface now has, local load balancing, rfid card registering and log download.
- UusiCheck that compute module and board have been created properly.
- ParannusScreen is now monitored so that it refreshes in the case that no requests have been made after 15 seconds.
- ParannusQA diagnostic is obtained through access point.
- ParannusReduced access point available time to 10 minutes.
- KorjausFixed bug where connector stopped working properly when sending intensity 0.
-
- UusiInitial Version
Denka
Nykyinen versio 1.1.0 · Versioita: 10, ensimmäinen: lokakuu 2025
- UusiDynaaminen tehonhallinta useiden Denka- ja Pole-latureiden välillä samassa asennuksessa, automaattinen jakelu saatavilla olevan tehon mukaan.
- UusiDenka master voi lukea asennuksen mittarin RS485:n kautta jakamaan koko talon tehoa.
- UusiDynaamisen ohjauksen maksimiteho säädetään kW:na V2C-alustalta.
- UusiOCPP: Yhteensopivuus OCPP-turvaprofiilien 0, 1, 2 ja 3 kanssa sekä Basic Auth -todennus; OCPP-salasanaa voidaan muuttaa pilvestä, Bluetoothin ja paikallisen verkkosivun kautta.
- UusiOCPP: Laturin sisäiset virheet ilmoitetaan CSMS:lle StatusNotificationin kautta
- UusiLataushistoria yksityiskohtaisilla mittareilla jokaisesta istunnosta (energia tunnissa, lopullinen lataustila ja ajoneuvon raja), sivutettu paikallisessa verkkosivustossa.
- ParannusViestintä tehomoduulin kanssa vakaampaa, paljon vähemmän virheitä latauksen aikana eikä vääriä vikailmoituksia käynnistyksen yhteydessä.
- ParannusLuotettavammat laturin uudelleenkäynnistykset
- ParannusNopeampi 4G-yhteys verkkoon, oletus-APN ja tuki Wireless Logic SIM-korteille.
- ParannusVerkko: Merkittäviä parannuksia verkon yhteyden hallintaan. Automaattinen vaihto Ethernetin, WiFin ja 4G:n välillä vakaampi, ja staattinen IP sovellettu oikein.
- ParannusLevytilan hallinta: lokit kiertävät ja rajoittuvat ilman historian menetystä ja estävät muistin täyttymisen.
- ParannusParannus auton (SLAC) ja maksujärjestelmän välisen viestintävirheen validoinnissa.
- ParannusMerkittävä parannus virheraportointiin tai deadletters-raportointiin eri V2C-alustoille.
- KorjausSähkökatkon keskeyttämät lataukset suljetaan ja laskutetaan oikein, kun virta palautuu.
- KorjausOCPP: OCPP-viestijono ei enää tukkeudu, kun palvelin vastaa virheellä.
- KorjausOCPP: Jos OCPP-palvelin hylkää tapahtuman aloituksen, lataus pysähtyy.
- KorjausOCPP: Vapaa tila voidaan nyt poistaa käytöstä asentajan paneelista.
Aiemmat versiot 9
-
- ParannusKorttimaksut suljetaan, kun ajoneuvo on irrotettu kokonaan, jotta veloitettu summa vastaa aina toimitettua energiaa.
- ParannusLuotettavammat uudelleenkäynnistykset latureissa, joissa on mobiiliyhteys (4G).
- KorjausÄlykkäiden latausprofiilien kesto, jotka lähetetään OCPP:n kautta, sovelletaan nyt oikein.
- KorjausOdotettavissa olevat OCPP-viestit eivät enää katoa päivitettäessä aiemmasta versiosta.
- 1.0.5ParannusLaturi käynnistyy oikein, vaikka verkkoyhteyttä ei ole saatavilla.
-
- ParannusYhteys OCPP-alustaasi palautuu automaattisesti verkkovirheen jälkeen.
- ParannusRFID-lukija palautuu itsestään lukemisvirheen jälkeen ilman, että laturia tarvitsee käynnistää uudelleen.
- KorjausMääritysmuutokset saattoivat lakata soveltumasta sisäisen virheen jälkeen. Nyt ne sovelletaan aina.
- KorjausMaksupääte ei enää käynnisty, kun se on poistettu käytöstä.
- 1.0.3KorjausLaturi saattoi lakata vastaamasta pitkän käyttöajan jälkeen. Korjattu.
-
- ParannusOCPP-asetuksesi ja avaimet säilyvät päivittäessäsi laturia.
- ParannusTehonhallinnan laiteohjelmisto päivitetty vakaampaa ja tarkempaa latausta varten.
- YhteensopivuusDenka liittyy V2C:n yhtenäiselle alustalle ja siirtyy uuteen 1.x-versiosarjaan, joka korvaa 0.14.x-sarjan.
- KorjausVirheet latausistunnon aloittamisessa tai lopettamisessa OCPP:n kautta.
- KorjausLaturi ei enää yritä muodostaa yhteyttä pilveen loputtomasti vanhentuneilla tunnistetiedoilla.
- KorjausRFID-kortit, joissa on numeerisia koodeja, luettiin virheellisesti.
- KorjausPäivitykset saattoivat epäonnistua siirryttäessä tietyistä versioista.
-
- ParannusÄlykäs lataus: tehosäädin asentajan paneelissa.
- ParannusYleisiä parannuksia järjestelmän vakauteen ja luotettavuuteen.
- ParannusYleisiä parannuksia toimintaan ja vakauteen.
- KorjausKorjauksia OCPP-älylatauksen toimintaan.
- KorjausKorjattu ongelmia järjestelmän hälytysten hallinnassa ja palautuksessa.
-
- UusiLatauksen pysäytys tiettyyn SoC-arvoon
- UusiHätätilapainikkeen tilaraportti.
- UusiLiukusäädin web-palvelimessa.
- UusiAjoneuvon SoC-raportti ja protokolla taustajärjestelmään.
- UusiSuora menetelmä `currentcharge` palauttaa nyt jäljellä olevan ajan SoC bulkille ja täydelle.
- UusiSuora menetelmä `autossh`-palvelun uudelleenkäynnistämiseen.
- UusiIP-tilan (julkinen/yksityinen) asetus 4G-yhteydelle.
- ParannusÄlykäs OCPP-lataus.
- ParannusSuorituskyvyn parannuksia.
- ParannusWiFi-moduulin käynnistys.
- ParannusHTTP-palvelimen siirto.
- KorjausVirheiden korjaus käynnistysasetuksissa.
- KorjausVirheiden korjaus OCPP:n älykkäässä latauksessa.
- KorjausVirheiden korjaus web-palvelimessa ja yhteydessä laitteistoon.
-
- ParannusParannus DC-parametrien lähetyksen suorituskykyyn.
- KorjausKorjattu SPI:n lukitus.
- KorjausVirhe `TimerHandler`-toiminnossa `n_connectors` kanssa.
-
- UusiIntegrointi raportoituja ominaisuuksia koskeviin muutoksiin.
- UusiRFID-kalibroinnin säätö asennuspaneelista.
- UusiIntegrointi jaetun kirjaston tarkkailtuun ominaisuuteen.
- UusiLatauksen pysäytys tiettyyn SoC-arvoon.
- UusiLatausvalkoinen lista MAC-osoitteen mukaan.
- KorjausVirhe `TimerHandler`-toiminnossa `n_connectors` kanssa.
- KorjausHotfix viestien lähetyksen lisäämiseksi.
Screen
Nykyinen versio 2.20 · Versioita: 66, ensimmäinen: maaliskuu 2022
- KorjausFixed rfid bug in ocpp.
Aiemmat versiot 65
- 2.19KorjausFixed rfid card issue in stop transactions.
- 2.18KorjausFixed OCPP error where transaction wasn't started when states passed from C to B to C.
- 2.17KorjausCB Master: Improved robustness of rfid charge track so that if one connector is fully charged and a different car wants to charge in the other connector it can now charge.
- 2.16KorjausCB Master: Fixed bug that wouldn't allow two connectors to charge with payment + RFID.
- 2.15UusiCB Master/CB N: Rfid cards can start a charge in payment mode if rfid is enabled.
- 2.14KorjausCB Master: We check if measurer is flipped by connector instead of globally.
- 2.13KorjausCB Master: We check if measurer is flipped while configuring meter values so that they are sent correctly.
-
- KorjausCB N: Fixed cloud iot problem.
- KorjausCB Master: Configuration file is restored correctly in the case it's lost. This provoked the page not found error.
- KorjausCB Master: Fixed bug where a connector couldn't start a charge when there's a car on the other connector with state B.
- 2.11KorjausCB Master: Meter power bug fix.
-
- UusiCB N: Car state management D and E.
- ParannusCB N: General payment improvements.
- ParannusCB N: In payment method, when you move from status c to b, it does not allow you to reload again until you start a new transaction.
- ParannusCB N: Improved restart logic when any OCPP configuration is changed.
- ParannusCB Master: General meter improvements.
- ParannusPole: Filter to reduce number of logs.
- KorjausCB Master: Fixed payment bug that sent the upload permission to the wrong connector.
- KorjausCB Master: Fixed bug that when two cars were connected and the B connector was in B status, when the card was swiped, the B was set to charge when the A should be set.
- KorjausCB Master: Total energy bug arrangement from version using imported and exported energy.
-
- ParannusCB Master: Meter restructuring.
- ParannusOCPP: General improvements in Smart Charging and Tx Profile implemented.
- ParannusOCPP: Changes due to restructuring of the meter.
- ParannusOCPP: Restructuring of smart charging. Obtain composite timetable with several profiles.
-
- UusiCB Master: Integrated SACI meter and changes so that the serial configuration per connector is not linked.
- ParannusCB Master: Increased RFID SPI communication speed and lowered RFID gain if noise is detected.
- ParannusCB Master: Code refactoring
-
- UusiOCPP: Starting point for get composite schedule done.
- UusiOCPP: Relative profiles are handled but only for Smart Charge profiles where connector id is bigger than 0.
- UusiOCPP: Smart Charging Tx Profiles are now accepted.
- UusiOCPP: In websocket connection, added "compression=None" since without it it doesn't work on latest Steve version.
- ParannusCB Master: Refactored serial and made some changes that improve flexibility. We can now have one connector with one type of measurer and the other connector with a different type of measurer.
- ParannusOCPP: Added next time check mechanism for Smart Charging so we check the next time any limit changes instead of every 30 seconds.
- ParannusOCPP: General Smart Charge improvements.
- KorjausCB Master: Convert to positive the negative values read by Phoenix Contact measurer.
- KorjausCB Master: Adjusted the precision of Phoenix Contact monophasic measurers.
- KorjausCB N: Fixed bug provoked by changing local load balancing from v2c service.
- KorjausOCPP: Change availability of Persistant Data handler is now async so that we can call it without blocking the execution of the ServerController.
- KorjausOCPP: Fixed clear charging profiles.
- KorjausOCPP: We handle decimal numbers on the Smart Charge profile's limit.
-
- UusiCB N: Changes due to Smart Charging
- UusiOCPP: Smart Charging starting point fininshed.
- UusiOCPP: Smart Charging configuration keys are handled.
- UusiOCPP: Smart Charging profiles can be added and will be validated and can also be deleted.
- KorjausOCPP, CB N and CB Master: Fixed bug when locked was modified and ocpp was activated but chargepoint isn't connected to any central system.
- KorjausCB Master: Fixed bug when OCPP charge is started where if connector 1 was charging, connector 0 couldn't start a charge.
- KorjausCB Master: Prevent crash in the case that .versions folder doesn't exist.
- KorjausCB Master: Register cards are now added to card cache.
-
- UusiPole: Screen now shows when user passes a non registered RFID card.
- ParannusCB Master: Improvements in update process.
- ParannusCB Master: Changes so that screen indicates when a non registered RFID card is passed.
- ParannusCB N: Improvements in update process.
- ParannusOCPP: GetConfigurationKeys now returns unknown keys and we handle SupportedFileTransferProtocols key.
- ParannusPole: Romanian identifier moved to position 6 to maintain order language with Trydan.
-
- ParannusCB Master: We store RFID cards in cache.
- ParannusCB N: RFID reader improvements. Case where two connectors are plugged in and a card is passed.
- ParannusCB N: New communication method so that CB master can obtain RFID cards.
- PoistettuCB Master: We don't send wifi_info in report anymore and we have removed functions related to wifi_info.
- PoistettuCB N: We don't send wifi_info in report anymore.
-
- UusiCB N: Static IP configuration through access point.
- ParannusCB Master: Improvement in connect/disconnect logic. Disconnection is less rigid and we increased network check from 5 seconds to 15 seconds.
- ParannusCB Master: Increased RFID reader antenna gain.
- ParannusCB N: When charger reconnects, it will only send report if a property has changed.
- ParannusCB N: Properties are now only reported when they have changed from previous value.
- KorjausCB Master: CWe fix error provoked by blocking/unblocking when charger has OCPP activated and isn't connected to central system.
- KorjausCB N: We fix error provoked by blocking/unblocking when charger has OCPP activated and isn't connected to central system.
- KorjausOCPP: We fix error provoked by blocking/unblocking when charger has OCPP activated and isn't connected to central system.
-
- ParannusCB Master: Safeguard so that it doesn't fail when there's a missing network card and we try to obtain data usage.
- ParannusOCPP: Removed range validation from measurer.
- PäivitettyCB Master: Removed range validation from measurer for Carlo Gavazzi and Phoenix Contact measurers.
- KorjausCB Master: Fixed energy by hour bug.
-
- ParannusCB N: We show in log if i2c reconnects.
-
- UusiCB Master: Chargebox Cache now stores state of connectivity with V2C service to show it on the screen.
- UusiCB N: Chargebox Cache now stores state of connectivity with V2C service.
- UusiPole: The screen now shows a cloud icon to indicate connectivity to our cloud.
- ParannusCB Master: Adjustment in measurer so that it can handle int32 represented as uint.
- ParannusCB N: Log improvements to not show get_has_internet_connection y and reduce error messages generated when i2c is not working.
- ParannusCB N: Changes to reduce calls to has_internet_connection to consume less data.
- ParannusOCPP: We log exception names since sometimes exception errors return empty string.
- ParannusOCPP: We capture error if there's an error when sending heartbeat.
- ParannusOCPP: We change client controller so that it's the same as CB N and CB Master.
- KorjausCB N: Seconds of timeout now return 0 instead of None if not set.
-
- ParannusCB Master: Master now sends the balanced intensity when it changes.
- ParannusCB N: Changed order of what happens when configuration is changed. We first update the value, then we report the changes to Azure and finally we set the cache.
- ParannusCB N: CB Master now sends balanced intensity instead of CB N probing for change.
- KorjausCB Master: Fixed error where RFID stops charge while the other connector is enabled.
- KorjausCB Master: Fixed error where RFID card is passed and both connectors have a car plugged in.
- KorjausCB N: Fixed bug where changing local load balancing set both connector intensities to 16.
-
- ParannusCB Master: Change in log system to not show repeated logs.
- ParannusCB Master: Shared properties are now set in the other connector if they are different on startup.
- ParannusCB Master: Completely decoupled OCPP from CB N and get_ocpp_config function fixed.
- ParannusCB Master: Network state is now sent when changed instead of being probed every 30 seconds.
- ParannusCB N: General improvements of communication between modules and cache.
- ParannusCB N: Improved stability related with missing configuration.
- ParannusCB N: Change in log system to not show repeated logs.
- ParannusCB N: Fixed problem where Chargebox loop would destroy RFID state.
- ParannusCB N: Fixed OCPP ConnectionTimeout.
- ParannusCB N: Completely decoupled OCPP from CB N
- ParannusCB N: Network state is now sent when changed instead of being probed every 30 seconds.
- ParannusCB N: We only change repository hash if it's different than the current one.
- ParannusCB N: Updating checks if charger is updated or not and only changes version after it has been updated.
- ParannusCB N: General improvements of communication between modules.
- ParannusOCPP: Improved Client Controller traceability.
-
- ParannusCB Master: Created Cache to decrease the number of requests and communication between modules.
- ParannusCB Master: Fixed network reset problem.
- ParannusCB Master: Changes so that Pole can receive all the information it needs in one call.
- ParannusCB Master: Changes dues to how the measures are now sent.
- ParannusCB Master: General access point improvements.
- ParannusCB Master: Improvements due to changes in module communication.
- ParannusCB N: Created singletons are now thread safe.
- ParannusCB N: Server Controller is now executed sooner due to being fundamental in correct functioning.
- ParannusCB N: Changes to take into account CB Master's cache
- ParannusCB N: Changed way we obtain measures to perform less requests with Client Controller.
- ParannusCB N: Improvements due to changes in module communication.
- ParannusOCPP: Created singletons are now thread safe.
- ParannusOCPP: Completely decoupled from CB N and now only communicates with CB Master.
- ParannusOCPP: Simplified communication between modules.
- ParannusOCPP: Improvements due to changes in module communication.
- ParannusPole: Created singletons are now thread safe.
- ParannusPole: Completely decoupled CB N and we obtain all information needed in one call to CB Master.
- ParannusPole: Improvements due to changes in module communication.
-
- ParannusCB Master: The charger now limits the number of messages that appear in the case that there's a range validation fail of a measure.
- ParannusCB N: Client Controller won't stop sending messages and will show errors every 10 wrongly sent messages.
- ParannusCB N: Restart Server Controller mechanism.
- ParannusOCPP: Client Controller won't stop sending messages and will show errors every 10 wrongly sent messages.
- ParannusOCPP: Restart async Server Controller mechanism.
- ParannusPole: Client Controller won't stop sending messages and will show errors every 10 wrongly sent messages.
- KorjausOCPP: If there's an error handling a request, we won't add it to the offline queue.
- KorjausOCPP: Include thread and sys libraries.
-
- ParannusCB N: When rebooting, we check module communication server.
- ParannusCB N: Decoupled concept of connector id and measurer address.
- ParannusCB Master: When rebooting, we check module communication server.
- ParannusCB Master: Decoupled concept of connector id and measurer address.
- ParannusCB Master: Fixed error in Phoenix Contact measurer.
- ParannusPole: ZMQ integrated to improve communication.
-
- ParannusPole: Improvement to let the user know when to connect the vehicle.
- ParannusPole: Screen now reflects if charger has only one connector.
- ParannusCB Master: Changed SSID format so that it's the same as Trydan's format.
-
- ParannusOCPP: Added measurer range validation.
- ParannusCB Master: Added measurer range validation.
- PäivitettyOCPP: AuthorizeRemoteTxRequests is now a read and write configuration key.
- KorjausOCPP: Fixed problem with repeated logs.
- KorjausCB Master: Fixed problem with repeated logs.
- KorjausCB N: Fixed problem with repeated logs.
-
- ParannusCB N: Handled special case of change intensity.
-
- UusiCB Master: Access point logic fininshed.
- UusiOCPP: Data validation when configuration is changed.
- UusiOCPP: Charger can now handle multiple transactions offline.
- ParannusCB N: If OCPP is on, we disable payment mode.
-
- ParannusOCPP: Reset function improved. Corresponding Status Notification is sent.
-
- ParannusCB N: General stability improvements.
- ParannusCB N: Changed payment method approach.
- ParannusCB Master: Changed payment method approach.
- ParannusCB Master: Improved robustness in the case the access point software is not installed.
- ParannusPole: Improvements due to payment method.
-
- UusiOCPP: Change availability validates connector.
- UusiCB Master: Finished Access point.
- ParannusCB Master: Changed compressed file formats from gzip to gz
- ParannusCB Master: Force backup when restarting.
-
- UusiCB N: Allow to change intensity, when i2c is failing.
- UusiCB Master: Implemented most of the access point server functionalities.
- KorjausCB Master: Fixed OCPP measurer error that ocurred when all selected measures in Meter Values returned 0.
- 1.4.3UusiCB Master: Initial version of the access point server.
-
- ParannusCB N: Changes to improve Pole software.
- ParannusPole: Changes to simplify view logic.
- KorjausCB Master: If payment mode is active, charger won't allow to charge with RFID card.
- KorjausPole: Removed sourceMappingUrl to prevent 404 error when there's no internet.
- 1.4.1KorjausCB N: Payment mode changed since payload format for server has changed.
- 1.4.0UusiPole: Changes in screen software that reflects payment mode, blocking connectors and OCPP.
-
- KorjausOCPP: Charger won't send Authorize if passed RFID card is already used in a transaction.
- 1.3.23ParannusOCPP: We store RFID cards in lower caps to improve robustness.
-
- ParannusOCPP: Improved robustness of RFID cards stored in the Local Authorization list.
-
- ParannusOCPP: Improved Local Authorization logic.
-
- KorjausCB Master: Fixed wifilist sending format.
-
- UusiCB N: We report information regarding wifi_info. Direct method to ask for the SSIDs the raspberry pi detects.
- 1.3.18ParannusOCPP: Improved authorization cache handler.
-
- ParannusOCPP: Improved handling of measurer values.
-
- ParannusOCPP: Improved handling of configuration keys.
-
- PäivitettyCB N: Payment mode with duration and timers.
-
- ParannusOCPP: Improved MeterValues handler.
- 1.3.13UusiOCPP: Finished Local Authorization List profile.
- 1.3.12ParannusOCPP: Log Improvements.
- 1.3.11KorjausOCPP: Fixed bug that wouldn't send Authorize Request when passing the RFID card.
-
- UusiOCPP: Basic implementation of OCPP profiles: FirmwareManagement, LocalAuthListManagement, Reservation and SmartCharging.
- 1.3.9ParannusCB Master: Fixed RFID card reading with Wiegand reader for cards that have a 0 on the left side. Example of cards that failed: 32:0a:2c:23, 41:00:32:12.
-
- PäivitettyOCPP: Availability isn't managed by OCPP anymore. It is handled exclusively by property locked.
- 1.3.7ParannusCB N: If charger is blocked, led blinks won't be sent.
- 1.3.6UusiCB N: Payment Mode finished with start and stop.
- 1.3.5ParannusOCPP: Clear Cache can only be performed when all connectors are in the OCPP state Available.
-
- ParannusOCPP: Changes so that availability can be changed from CB N.
-
- ParannusCB Master: OCPP module can now ask for Status Notification.
- PäivitettyOCPP: The charger the different possible OCPP states in the Status Notification.
- 1.3.2ParannusOCPP: We can now set configuration parameters for safeguard.
- 1.3.1ParannusOCPP: Change availability is now completely functional. It changes to inoperative during a charge and availability changes the locked value.
- 1.3.0KorjausOCPP: Changed way we obtain measurer data for OCPP.
- 1.2.0KorjausOCPP: Temporary fix for Place to plug since OCPP library can't handle unknown keys.
- 1.1.0KorjausOCPP: Fixed _available_connectors error.
-
- UusiOCPP.
- UusiScreen.
- UusiPole.
- UusiCB Master.
- UusiCB N.
V2C Cloud -sovellus
Nykyinen versio 3.3.2 · Versioita: 30, ensimmäinen: helmikuu 2023
- UusiUusi sovelluksen oma tumma teema: kaikki näkymät mukautuvat oikein puhelimen tummaan tilaan.
- UusiUusi Ulkoasu-näkymä (Asetukset > Käyttäjätiedot > Ulkoasu) valitsemiseen: Automaattinen tila (seuraa puhelinta), Vaalea tai Tumma.
- UusiUusi QR- ja viivakoodinlukija, nopeampi ja luotettavampi, e-Chargerin tunnistamiseen Paymentsissa ja laiteparin muodostamisen aikana.
- UusiVirheilmoitukset selkeämmiksi, kun kirjautuminen epäonnistuu.
- ParannusSovelluksen puhtaampi käynnistys, ilman alkuvaiheen valkoista välähdystä.
- ParannusKorjattu kaksinkertaiset marginaalit ja harmaat palkit Android 14:ssä ja sitä vanhemmissa versioissa, kun sovellus suljetaan ja avataan uudelleen.
- ParannusSovellus kevyempi: merkittävä koon pieneneminen kuvien ja koodin optimoinnin ansiosta Androidissa.
- YhteensopivuusSovellus vaatii nyt Android 8.0 -version tai uudemman.
- PäivitettyTila Ei syöttöä tai eristetty latausprofiileissa: vähimmäisteho on 300 W, koska akkujen alhaisempi purkausteho ei ole riittävä. Jos syötetään pienempi arvo, järjestelmä antaa varoituksen.
- KorjausKorjattu virhe, jonka vuoksi juuri luodut latausprofiilit saattoivat kadota, kun etusivun näkymä päivitettiin.
- KorjausKorjattu ajastetun latauksen ikkuna (Klassinen ja EcoCharging), joka mukautuu nyt niin, että kaikki sen sisältö näkyy ilman vierityspalkkia.
Aiemmat versiot 29
-
- UusiUusi V2C:n oma ilmoitusjärjestelmä, luotettavampi, sekä ilmoitusoikeuden pyytäminen Androidin uusimmissa versioissa.
- UusiUudet kielet saatavilla: puola, liettua, yksinkertaistettu kiina ja tšekki.
- UusiUusi suosikkilista e-Chargers-latauslaitteille Payments-sivulla: tallenna usein käyttämäsi e-Chargers-latauslaitteet haluamallasi nimellä ja aloita lataus yhdellä napsautuksella.
- UusiKartalla näkyvät V2C e-Chargerit voivat jo käynnistää latauksen suoraan V2C Payments -palvelun kautta.
- UusiVoit suodattaa V2C:n e-Chargers-laitteet kartalla.
- UusiUusia invertterejä, jotka tukevat dynaamista tehonohjausta: SolPlanet, Hoymiles ja Huawei, joissa on suora WiFi-yhteys (saatavilla Trydan-versiolle 2.5.2 tai uudemmalle).
- UusiKotitalouden akun hallinta laajennettu koskemaan useampia inverttereitä: Sigenergy (versiosta 2.5.1 alkaen) sekä GoodWe, SolarEdge ja SolPlanet (versiosta 2.5.2 alkaen).
- UusiUusi ilmoitus Pole Pro -laitteessa, kun letkun mittari ei vastaa (virhe 3), saatavilla versiosta 6.1.0 alkaen.
- UusiUusi selitys sekalatausmoodin toiminnasta Erikoisasetukset-kohdassa.
- UusiPäänäyttö näyttää nyt käytössä olevan latausprofiilin nimen.
- UusiTilastot näyttävät nyt oikein negatiiviset kustannukset.
- UusiVirtuaalisen avustajan painike voidaan tallentaa näytön sivulle ja palauttaa tarvittaessa.
- UusiUusi selittävä viesti, kun jaat e-Chargerin sähköpostiosoitteeseen, jolla ei ole V2C-tiliä.
- UusiParannuksia koko sovellukseen visuaalisesti: järjestelmäpalkit, yläreunan marginaalit ja sovitus eri matkapuhelinmalleihin.
- ParannusKäynnistyy nopeammin ja kuluttaa vähemmän resursseja.
- ParannusUusi päivämäärävalitsimen ulkoasu globaaleissa tilastoissa ja jokaisen e-Charger-laitteen tilastoissa.
- ParannusParempi Bluetooth-yhteyden vakaus: yhteyden muodostamisen, latausteho-asetusten tarkastelun ja e-Chargerin asetusvalikoihin siirtymisen yhteydessä ei tapahdu jumittumisia.
- ParannusParempi istunnon vakaus: estetään odottamattomat uloskirjautumiset, kun sovellus on ollut pitkään taustalla, sekä lukitukset kirjauduttaessa iPhonella.
- ParannusPole Pro -laitteen turvallisempi verkkoasetus: Wi-Fi-verkon ja staattisen IP-osoitteen validointi, APN ei hyväksy ääkkösiä ja 4G-SIM-kortin esitystapaa on parannettu.
- ParannusKorjattu tariffien nimet ja näyttö sekä uudet värit, joilla jaksot erottuvat paremmin, kun sähkötariffia muokataan.
- ParannusSisäinen optimointi sovelluksen koon pienentämiseksi.
- PäivitettyV2C Payments: nyt vain e-Chargerin ylläpitäjä voi ottaa sen käyttöön, ja käyttöönoton yhteydessä valitaan latauspisteen sijainti.
- PäivitettyV2C Payments: uusi ilmoitus ennen jatkamista, jos e-Chargeriin ei ole Internet-yhteyttä tai se ei salli latausta juuri sillä hetkellä.
- PäivitettyLatauksen etusijan määrittäminen auton ja akun välillä näkyy vain, kun asennuksessa on invertteri tai Huawei EMMA -mittari.
- PäivitettyYhteensopivuus e-Chargers-laitteiden uusimman laiteohjelmiston uuden kielimuodon kanssa.
- KorjausKorjattu tilastoluettelon näyttö iPhonessa, jossa se saattoi näkyä katkaistuna.
- KorjausKorjattu Denkan näytetty vähimmäisteho, kun se on alle 1 kW.
- KorjausKorjattiin virhe, jonka vuoksi internetyhteysvirhe-ilmoitus näkyi ilman syytä.
- KorjausKorjattu virhe, joka ilmeni valittaessa automalleja, joiden nimessä on #-merkki.
- PoistettuSovellus ei enää pyydä sijaintiluvan käyttöä taustalla, koska se ei ole tarpeen.
-
- UusiParannuksia V2C Assistant -sovellukseen: uusi infonäkymä, joka selventää assistentin toimintaa.
- UusiParannuksia dynaamiseen ohjaukseen: Shelly Pro -laitteet ovat myös yhteensopivia V3:n kanssa.
- UusiParannuksia akkuasetuksiin: parannettu sen vaihtoehdon käyttöliittymää, jolla estetään laturia purkamasta kotitalouden akkua. Toiminto on nyt selkeämpi.
- UusiUusi yhteensopivuus Sigenergyn kanssa: Sigenergy on lisätty yhteensopivana inverterinä, joka tukee akun ohjausta latausprofiileissa.
- UusiUusi Solarman-invertterien löytötoiminto: lisätty järjestelmä, joka tunnistaa automaattisesti käytettävissä olevat Solarman-laitteet Dynaamisen ohjauksen asetusten aikana.
- UusiSolarman-haku Bluetoothin ja Wi-Fi-yhteyden kautta: uusi järjestelmä mahdollistaa haun käyttämällä käytettävissä olevia yhteyksiä.
- UusiParannuksia Solarmanin asetuksiin: löydetyt laitteet näytetään yksitellen, jotta niiden valinta ja määritys on helpompaa.
- ParannusParannuksia ajastettuun lataukseen: optimoitu ajastettujen latausten aikanäytön toimintaa.
- ParannusUusi virheenkäsittely: parannettu sovelluksen tiettyjen kutsujen toimintaa, kun tilavirheitä ilmenee.
- ParannusParannuksia Oasysiin: tietojen tallennusta on optimoitu, jotta asetukset säilyvät oikein.
- ParannusParannuksia AutoCharge-hallintaan: AutoCharge-toiminnon nimi ja esitystapa on päivitetty.
- ParannusParannuksia jakamiseen: jakonäkymään lisätty lisätietoja, jotta sen toiminta on helpompi ymmärtää.
- ParannusVisuaalisia parannuksia Solarman-löytämiseen: tilat, animaatiot, viestit ja vahvistukset hakuprosessin aikana on parannettu.
- ParannusYleisparannuksia: sovellusta on optimoitu ja korjattu useita virheitä, jotta käyttökokemus on vakaampi.
- PäivitettyParannuksia latausprofiileihin: enimmäisteho, jonka voi määrittää, on nostettu 12 kW:iin yksivaiheisissa asennuksissa ja 36 kW:iin kolmivaiheisissa asennuksissa, jotta asetusten määrittäminen on helpompaa ranskalaisille käyttäjille.
- PäivitettyUusi tukialue: tukialueen käyttöoikeus on päivitetty.
- KorjausParannukset latauslaitteiden jakamisessa: korjattiin ongelma, joka saattoi aiheuttaa virheitä latauslaitteen jakamisen yhteydessä.
- KorjausParannuksia karttoihin: lisätty tunnus ja päivitetty karttojen käyttämää käyttöoikeutta, jotta ne toimivat oikein.
- KorjausParannuksia invertterien määrityksiin: korjattiin useita tapauksia, jotka liittyvät liitäntäparametrien määritykseen ja validointiin.
- KorjausVakauden parannukset: korjattu useita ongelmia, jotka havaittiin lopputarkastuksessa, esimerkiksi lataustyypin vaihto erikoisasetuksissa ei toiminut oikein Bluetoothin kautta.
-
- UusiUusi OCPP-salasana lisäasetuksissa turvallisemman määrityksen varmistamiseksi.
- UusiUusi ilmoitus, kun sijaintilupaa ei myönnetä, jotta laitteen määritys on helpompaa.
- UusiUusi muistutus chatbotissa, joka pyytää sallimaan liikkumisen tarvittaessa.
- UusiParannettu todennuksen vakautta: estetään samanaikaiset tokenpyynnöt ja parannetaan tokenien sisäistä hallintaa.
- UusiTokenin hakemiseen on lisätty turvallinen aikakatkaisu, jotta poikkeustilanteissa järjestelmä ei jää jumiin.
- UusiUusi Sigenergy-asetusopas Modbus TCP:n avulla, jotta invertterin käyttöönotto on helpompaa.
- UusiUusi linkki Sigenergy-asetusoppaaseen, kun tämä invertteri valitaan dynaamisessa tehonohjauksessa.
- UusiYhteensopivuus Sigenergyn kanssa dynaamisessa tehonohjauksessa, ja laite tunnistetaan oikein invertteriksi.
- UusiUudet yhteensopivat invertterimallit: Azzurro ja SofarSolar.
- UusiUusi ilmoitus Alva-laitteen käynnistämisestä uudelleen tarvittaessa, jotta asetukset saadaan määritettyä oikein.
- UusiBluetooth-virheilmoitukset tarkemmiksi, kun latausasemaan ei ole mahdollista muodostaa yhteyttä.
- UusiUudet Ingeteam-invertterimallit ja liitäntätietojen validointi, jotta niiden määrittäminen on helpompaa.
- UusiValinta käytettävissä olevasta lataustyypistä Erikoisasetukset-kohdassa (saatavilla Trydan-versiolla 2.5.0 tai uudemmalla).
- ParannusParannuksia Alvan Bluetooth-yhteyteen: nopeampi ja vakaampi tiedonsiirto.
- ParannusChatbot-palvelu tarjoaa nyt hyödyllisempia suosituksia ja kysymyksiä, jotka on suunnattu sinun kokoonpanoosi ja tilanteeseesi.
- ParannusParannuksia älypuhelinten määrityksiin ja pariliitäntään liittyvien tekstien käännöksiin.
- ParannusParannuksia hollanninkielisiin käännöksiin, jotta käyttökokemus olisi johdonmukaisempi.
- ParannusParempi hallinta tilastotietojen lähetyksessä Bluetoothin kautta, mikä estää ongelmat silloin, kun tiedot ovat vaurioituneet tai puutteellisia.
- ParannusSovelluksen sisäinen optimointi sen koon pienentämiseksi ja yhteensopivuuden parantamiseksi Androidin uusimpien suositusten kanssa.
- ParannusParannus latausprofiilien herkkyyteen, jotta osuutta ei muuteta napsauttaessa.
- ParannusParannus, jolla latausprofiilien tunnit voidaan muuttaa tarkasti tarpeen mukaan.
- ParannusParannus Alva-laitteen dynaamisen tehonohjauksen tietojen hallintaan, korjaten virheitä niiden kyselyn aikana.
- ParannusParannettu luotettavuus Trydanin Bluetooth-kellonajan synkronoinnissa.
- PäivitettyAkun latauksen prioriteettiviestiä latausprofiileissa on päivitetty selkeämmäksi.
- KorjausLisää säätimien tarkkuutta, ja painikkeiden napsauttaminen lähettää nyt tiedot oikein.
- KorjausKorjaus tyhjään kortiin erikoisvaihtoehdoissa.
-
- UusiNäytä kotiakun lataus etusijalla latausprofiileissa (versio 2.5.0 tai uudempi).
- UusiLisää yksityiskohtaisia tietoja akkujen prioriteetista latausprofiileissa.
- UusiLisätty EMMA yhteensopivaksi invertteriksi, joka estää akkujen purkautumisen.
- UusiLisätty maksuihin hinta käyttämättömyydestä.
- UusiLisätty COM-osoite EMMA-mittariin.
- UusiLiitäntätyypin lähetys ALVA-laitteeseen.
- KorjausKorjattu virhe, joka esti ponnahdusikkunoiden avaamisen.
-
- UusiLisätty integroitu tekoälychatbot.
- UusiLisätty latauksen päättymisen kirjaus Erikoisasetuksiin Trydan-laitteille (versio 2.5.0 tai uudempi).
- UusiLisätty uusi räätälöity jaksotaripaketti.
- UusiOasys-kaavioiden tiedot esitettynä samoin kuin verkkosivustolla.
- UusiUusi kenttä "Akun varaustaso" lisätty Oasys-kaavioon.
- UusiLisätty haku käyttäjille, joilla on paljon latureita (yli 10).
- UusiSivutus suurten RFID-korttien ja eKey-avainten määrien hakemiseen Bluetoothin kautta.
- UusiAlva-laitteiden latausliittimien enimmäisvirran rajoitusilmoitus on 640 A, koska niissä on kaksi latausliitäntää.
- UusiParannuksia RFID-suunnitteluun, sivutukseen, hakukoneeseen ja tyyppikohtaiseen erotteluun.
- UusiNäytä versionumero, johon laiteohjelmisto päivitetään.
- UusiBluetooth-käyttöoikeuden tarkistus ja käyttäjän ilmoittaminen.
- UusiVirheilmoitus näytössä: rajoitettu virta mallien 16 A kohdalla.
- UusiChint saatavilla Denka- ja Pole-malleihin.
- UusiUusi GIF lisätty kuvaamaan akun purkautumista ja aurinkosähköntuotantoa.
- ParannusUusi ja parannettu käyttökokemus latausprofiileille.
- ParannusParannus Energiatariffi-näytön käyttökokemukseen mukautetuille tariffeille.
- ParannusParannus ja optimointi Payments-tapahtuman aikana tehtyihin kutsuihin.
- ParannusYleiset Bluetooth-parannukset.
- ParannusParannukset käyttäjienhallinnan näkymän ulkoasuun ja mahdollisuuteen, että ylläpitäjä voi poistaa laturin tästä näkymästä.
- ParannusLatauksen enimmäisvirta liittimissä rajoitettu ja käyttökokemusta parannettu.
- KorjausEstä negatiiviset arvot Oasys-kaavioissa.
- KorjausKorjattu epäjohdonmukaiset värit Oasys-kaavioissa.
- KorjausParannus painikkeen käyttökokemukseen salasanan vaihdossa, jotta useat painallukset estetään.
- KorjausKäynnistyksen nopeuttaminen sovelluksessa ilman verkkoyhteyttä.
-
- UusiAkun purkamisen hallinnan ilmoitus Ingeteamin ulkoisessa sovelluksessa.- Ilmoitus akun purkauksen hallinnasta Ingeteamin ulkoisessa sovelluksessa.
- UusiJärjestelmänvalvoja voi nähdä, onko latauslaitetta hallinnoimassa asentaja. Muut käyttäjät voivat nähdä, kuka on järjestelmänvalvoja.
- UusiUusi tunniste kapasiteettitiedoissa.
- UusiAkut-kenttiin on lisätty yksityiskohtaiset selitykset.
- UusiPäivitys versioon 2.5.0, joka lisää tuen akun purkamiselle.
- UusiLisättiin varoitusilmoituksia, jotka muistuttavat käyttäjää olemaan varovainen painaessaan tiettyjä arkaluonteisia toimintoja.
- UusiLisättiin sähköverkon hallinta Oasys-asetuksiin.
- ParannusParannuksia kaikissa Oasys-näytöissä
- ParannusParannuksia sovellukseen (v2c): Energiatariffi on lisätty Oasysiin.
- PäivitettyTarkistus RFID-tunnisteiden ja eKeyjen pituudelle (vähintään 3 merkkiä).
- PäivitettyIngeteam ja EMMA on piilotettu luettelosta akun purkamista tukevista invertereistä.
- KorjausKorjattiin virhe, joka esti viestin "Evitar descarga de batería" näyttämisen oikein.
- KorjausKorjattiin virhe, joka ilmeni tallennettaessa asetuksia Goodwe-invertterin kanssa.
- KorjausKorjattiin virhe, jonka vuoksi pääfunktio suoritettiin silmukassa myös silloin, kun näkymästä oli poistuttu.
- KorjausKorjattiin Denkan tehorajoitus (piilotettu, mutta valmis).
- KorjausKaikki kuvaruudun maksunäytöt piilotettiin pysyvästi, eikä niissä enää näytetä virtaa.
- KorjausKorjattu mahdollinen tietoturvahaavoittuvuus.
-
- UusiLatauksen olevan käynnissä tilastoissa ilmoitetaan.
- UusiNyt tilastoissa näkyy RFID-korttien nimi.
- UusiAkkujen päänäkymät on viimeistelty ja niissä näkyy todellisia tietoja.
- UusiLisätty valintaruutu akkujen purkautumisen estämiseksi versiosta 2.4.7 alkaen joillakin invertterillä
- ParannusParannettu laiteohjelmiston päivityksen näkymän luotettavuutta (päivitysvaihtoehto näkyy vain, jos nykyinen versio on ehdottomasti pienempi kuin tuotannossa oleva uusin vakaa versio).
- PäivitettySallia toimittajien muokata energiatariffia.
- KorjausKorjattu virhe GIF-kuvassa ilman PV:tä.
-
- UusiInverttereiden erottaminen: Azurro ja Sofar Solar.
- UusiEstoppa liian pitkien koodien lisääminen RFID- tai eKey-tunnisteisiin ja käyttökokemuksen parantaminen.
- UusiUusi Azurro-invertteri.
- UusiParannettu sujuvuus kartan valikoissa.
- UusiLisätty ikkunoiden kokoa tietojen näkyvyyden parantamiseksi.
- UusiUusi parannettu tilastojen ulkoasu.
- UusiLisätty uusi Huawei EMMA -mittari.
- UusiInverttityypin nimenvaihto: Sunny SMA.
- UusiLisätty ajoneuvon rekisterinumero.
- UusiLisätty käytetyn aurinkosähköjärjestelmän tyyppi latausprofiileihisi jokaisella hetkellä GIF-kuvaan
- UusiSivutus valmis RFID-toiminnolle Denkassa ja Pole Prossa
- UusiUudet Fronius-tyypit rajoitettuna versioihin 2.4.2 ja uudemmat
- ParannusParannettu sähköauton tietojen näkyvyys.
- ParannusParannus italiankielisiin käännöksiin.
- ParannusKäännösten yleinen parantaminen.
- ParannusKäytettävyysparannuksia ja painikkeiden uudelleensijoittelua EcoChargingissa
- ParannusParannus Payments-datan näytteenottoon
- KorjausKorjattu autocharge-tilan tarkistus (sitä ei pitäisi suorittaa tässä tapauksessa).
- KorjausKorjattu sähköauton tietojen virhe.
- KorjausPäivitys tokenin päätepisteeseen koko sovelluksessa.
- KorjausKorjattu virhe Pole-laitteiden MAC-osoitteita sisältävässä asetusnäytössä.
- KorjausParannettu yhteensopivuus suurten näyttöjen laitteiden kanssa.
- KorjausIkkunan turva-alueiden säädöt iOS-laitteissa.
- KorjausKorjattu end-to-end-ongelma Android 15:ssä.
- KorjausPäivitetty päästä päähän vanhentuneet API-rajapinnat.
- KorjausLisätty safe-area-alueet, jotta estetään päällekkäisyydet järjestelmäpalkkien kanssa.
- KorjausKorjattu kriittinen tietoturvahaavoittuvuus Androidissa.
- KorjausPiilotettu latauksen tavoite, jos laitteessa ei ole sitä versiota, jota tarvitaan (2.4.3)
- KorjausKorjattu virhe, joka esti laiteohjelmiston päivittämisen paikallisen Wi-Fi-yhteyden kautta.
-
- UusiLisätty tietoa latauksen aikaisista kustannuksista käyttäjille, joilla on aurinkovoimala.
- UusiMuutos Mapbox-tunnuksessa karttahaun toimintoa varten.
- ParannusBluetooth-yhteyden nopeutus.
- ParannusParannus BLE-parikytkennän suunnitteluun.
- ParannusRefaktorointi
- ParannusBluetooth-yhteyden optimointi iOS-laitteilla.
- ParannusKäännösten parantaminen kontekstin mukaan kaikilla kielillä.
- PäivitettyMuutos V2C Business Panelin sijaintiin: se on nyt päätason asetuksissa.
- KorjausKorjattu virhe V2C Business Panelin määrityksessä.
- KorjausKorjattu virhe latauksen tavoitteen valintaruudussa.
- KorjausKorjattu RFID/eKeys-näytön virhe ALVA-laitteilla.
- KorjausKorjattu bugi, jossa karttavalikot menivät päällekkäin iPhonen notchin kanssa.
- PoistettuPäivitetyn orjalaitteen piilotettu päivitys
-
- UusiValmis widget, toimii Androidilla ja iOS:llä.
- UusiLisätty tekoälyllä toimiva chatbot usein kysytyille kysymyksille.
- UusiSelitys ja huomautus Linky-mittarille.
- UusiUudet protokollat Goodwe-invertterille.
- UusiUudet linkit uusiin ”informatiivisiin videoihin”.
- UusiUusi näyttö laitteiden pariliitokseen Bluetooth-yhteyden lähietäisyydellä.
- UusiUusi näyttö aikavyöhykkeen määrittämiseen.
- UusiLisätty Alva mallistoon
- UusiUusi vaihtoehto liittää e-Charger yritykseesi.
- UusiKaksi uutta alatyyppiä Fronius-invertterille.
- UusiUusi tariffi Ranskalle: Tempo edf
- ParannusParempi UX-suunnittelu perinteiselle ajastetulle lataukselle.
- ParannusParannettu tiedonsiirto ja dynaamisen ohjauksen ilmoitukset.
- ParannusRefaktorointi osasta koodia.
- ParannusJoidenkin virheellisten tunnisteiden parantaminen kaikilla kielillä.
- ParannusParannus hätäpainikkeen painamisen ilmoituksen näyttämiseen Denka-laitteissa.
- ParannusParannettu virheilmoitusten tarkkuutta, kun latausasema jaetaan.
- PäivitettyPäivitetty iOS-kirjastot.
- PäivitettyUusi asettelu sähköautosi tietojen lisäämiseen
- KorjausTilastot perustuvat aloituspäivämäärään, jolloin ne näkyvät valitulla aikavälillä.
- KorjausKorjattu virhe, joka ilmeni, kun SSID jätettiin tyhjäksi Pole-laitteissa iOS-laitteilla.
- KorjausSaksankieliset käännökset on korjattu.
- KorjausKorjattu iPhonen karttaan liittyvä virhe.
- KorjausKorjattu virhe kustannusten näytössä tilastoissa.
-
- UusiLisätty ilmoitus hätäpainikkeen aktivoitumisesta Denka-laitteessa.
- UusiAutocharge-toiminto: Denka-laturin valtuutettujen ajoneuvojen luettelo.
- UusiUusi virtaus aurinkosähköjärjestelmän kaaviossa.
- UusiLataaja jaettavissa suoraan sähköpostin kautta.
- UusiParannus manuaalisen tilastojen lähetyksen lokeihin.
- ParannusParannus latauksen skeleton-latausnäkymään etusivulla
- ParannusParhaa selitys vaihekohtaisesta virrasta
- ParannusKäännösten parantaminen italian kielellä
- ParannusPoistettiin suuntarajoitus, jotta laite toimii paremmin joidenkin tablettien kanssa.
- PäivitettyPäivitetty kirjastot
- PäivitettyPäivitetty Firebase-kirjasto paremman turvallisuuden takaamiseksi.
- PäivitettyStaattisen IP-osoitteen asetusten ominaisuuksien oikea järjestys.
- KorjausKorjattu virhe EcoChargingin päivittämisessä tiettyyn aikaan
-
- UusiLisätty G2-tyyppi Goodwe-invertteriin
- UusiLisätty latauksen rajoitus Denkoihin
- UusiDenkan auton akun kapasiteetin esittely.
- UusiLatauksen jäljellä oleva aika Denkassa
- ParannusLisää tilaa alavalikolle joillakin laitteilla
- ParannusParannus alatyylipalkin näkymään käyttäjille, joilla on erittäin suuri fonttikoko
- PäivitettyMuutokset Solis-invertterin tyypissä
- PäivitettyMuutos tilastojen otokseen: endCharge huomioidaan samalla tavalla kuin palvelimella
- PäivitettyMuutos palvelinkutsuihin, joista puuttuu lopussa oleva kauttaviiva
- PäivitettyPiilotettu herätystila
- PäivitettyPiilotettu tyyppi ”Yleiset rekisterit” DEYE-invertterissä
- PäivitettyGPS ei ole välttämätön vaatimus sovelluksen lataamiselle.
- PäivitettyEi enää tarvitse ilmoittaa käyttäjän aluetta sähköauton asetuksissa
- KorjausKorjattu virhe tietojen haussa Erikoisasetukset-kohdassa
- KorjausPienten virheiden korjaaminen
-
- UusiSalli SIM-kortin datan lataaminen ilman, että e-Charger on yhdistettynä
- UusiUudet varoitusviestit herkissä toiminnoissa
- ParannusYleinen vakauden parantaminen
- PäivitettyOminaisuuden nimi muutettu nimeen term_resistor
- KorjausAlavalikko ei enää peitä tietoja
-
- ParannusPortugalin kielen käännösten kokonaisvaltainen parantaminen
- ParannusKäännösten kokonaisvaltainen parantaminen ranskaksi
- ParannusKäännösten osittainen parantaminen saksaksi
- KorjausKorjattu virhe, joka ilmeni muutettaessa tehoa Denka-latureissa
- KorjausParempi virheenhallinta kartalla
-
- UusiVaihekartoitus Trydanille
- UusiSalli apulaitteiden muuttaa enimmäis- ja vähimmäisvirtaa
- UusiLatauprofiilien käyttörajoitus muille kuin pääladureille ja virtarajojen erottelu
- UusiMuutos ja ilmoitus DEYE-invertterityypeille
- UusiLisätty näkymä BUS-väylän päätevastuksesta dynaamisessa tehonohjauksessa
- UusiParannettu tiedonlatausta verkkonäytössä
- UusiPaikallinen kuormanjako Trydan: näytä BUS-päätevastuksen tila
- UusiSuurempi luotettavuus tilastojen lähettämisessä Bluetoothin kautta
- UusiUusi käynnistysnäyttö (splash screen) määritetty ja optimoitu
- UusiParannettu sovelluksen uudelleenkäynnistys ilman täydellistä sulkemista. Valmiit uudet ulkoasut, joiden taustanäyttöä voi mukauttaa.
- UusiUusi logiikka laitteen päänäytössä
- UusiUusi tietojen latausnäkymä päänäytöllä
- UusiValmis: suodatus toimittajittain
- UusiLisätty skeleton-lataustilat (moderni tietojen lataus) päänäytöissä
- UusiUusia palvelinkutsuja, tapahtumien ryhmittely ja sivutus
- UusiUudet palvelinkutsut, laskujen listaus ja lataus tyypin mukaan
- UusiTilastoihin lisätty kello kellonajan viereen, €-merkki vaihdettu yleiseksi valuuttasymboliksi ja yleisiin tilastoihin lisätty tilastoluettelo.
- UusiUusi tyyppi DEYE-laitteessa ja uusi Linky-mittari lisätty
- UusiSovellus käännetty baskiksi ja refaktoroitu uusien kielten lisäämisen helpottamiseksi
- UusiLisätty uusia energiatariffeja
- UusiLisätty uusi näyttö ilmaisten maksujen vahvistamiseen
- UusiLisätty toinen tyyppi Goodwe-invertterille
- UusiVaroitus e-Charger-laitteen uudelleenkäynnistysviestissä
- UusiUudet taksat laskevat hinnan oikein latauksen näytössä
- ParannusUlkoasun parannukset ja päivitykset kaikille Dynamic Island -tuella varustetuille iPhone-näytöille
- ParannusParannuksia tilastojen näkymään
- ParannusParannettu tilastojen näyttämistä pitkillä aikajaksoilla
- ParannusParannus skeleton-latauksiin
- ParannusInverttereiden ja mittareiden aakkosjärjestys
- ParannusHyvin ajoitettu EcoCharging-säästöhinta ja mahdollisuus jatkaa latausta missä tahansa tilassa
- ParannusParannuksia laitteen päänäyttöön
- ParannusParannuksia LetMeCharge-palveluun
- PäivitettyPäänäyttöjen uudelleenjärjestely
- PäivitettyAkkukapasiteetin lähettäminen numerona tekstimerkkijonon sijaan
- PäivitettyMuutettu palvelimen tapahtumakutsut uusiin.
- KorjausPiilota Tyyppi Muutos Portugali
- KorjausKorjattiin raja-arvot virrankululle päänäytössä ja uudistettiin sekä refaktoroitiin asetusnäyttö
- KorjausKorjattu numeerinen syötetyyppi joissakin kentissä, joihin pystyi syöttämään tekstiä.
- KorjausKorjattu virhe latauprofiilien valinnassa: lataus alkoi aina kohdasta "arkipäivät".
- KorjausKorjattu virhe aurinkosähkö-GIFissä
- KorjausKorjaus tunnuksen (token) päivityksessä
- KorjausKorjattu virheen firmware-version näyttämisessä
- KorjausKorjattu virhe välimuistia vaihdettaessa
- KorjausNo näytä lukitusta, jos laturi ei ole yhdistetty (Wi-Fi tai Bluetooth), ja korjattu virhe tehonsyötön tasoa näytettäessä
- KorjausEstäpä näytön lukittuminen internet-yhteyden vuoksi tilastoissa
- KorjausKorjattu tilastojen näyttämisen virhe
- KorjausKorjattu dynaamisen säädön virhe, IP-osoite määrittelemätön
- KorjausKorjattiin pieniä virheitä
- PoistettuKäyttämättömien näyttöjen poistaminen
- PoistettuPoistettu korttien reunus
- PoistettuPoistettu tarpeettomat elementit
- PoistettuPoistettu virtarajoitus vaihetta kohden, kun laturi on yksivaiheinen
-
- UusiUudet käyttöoikeudet ja rajoitukset e-Charger-mallin ja käyttäjärooliin mukaan
- UusiEnimmäis- ja vähimmäistehon rajoitus Denkassa
- UusiAnimaatio ilman latureita, mukautettu uuteen ulkoasuun
- UusiUusi dynaaminen ohjaus Trydan-laitteille, joissa on versio 2.3.0 tai uudempi
- UusiLisätty kartta (Saatavilla hyvin pian)
- UusiUusi muotoilu alavalikolla
- ParannusRefaktorointi ylläpidettävyyden parantamiseksi
- ParannusParannus pääruutujen välisessä yhteydenmuodostuksessa
-
- PäivitettyPäivitys iOS SDK:lle, jotta julkaisu voidaan tehdä.
- KorjausKorjattu virhe EcoCharging-suunnitelman luonnissa.
- KorjausKorjattu fonttikoko joillakin näytöillä.
- KorjausKorjattu virhe, joka ilmeni valittaessa staattinen ohjaus Pole Pro -laitteessa.
- KorjausKorjattu virhe, joka ilmeni sijainnin pyytämisessä Android 14 -laitteilla.
- PoistettuTäydellinen poisto sovelluksesta kuormituksen tasapainotus eri latauspisteiden välillä (nyt se sisältyy dynaamisen tehonhallinnan toimintaan).
-
- UusiSarjanumero lisätty Enphase-invertteriin.
- UusiLataustilastokaavio lisätty EcoCharging-sovellukseen.
- UusiSovelluksen uudelleenrakennus ja uusi tapa näyttää dynaaminen tehonhallinta latauslaitteen e-Charger -version ja mallin mukaan.
- UusiItalian-kielen lisääminen Pole Pro -laitteeseen
- UusiOmistajat voivat muokata luottokorttiaan.
- UusiÄlä salli latausprofiilien määrittämistä laitteelle, joka ei ole Maestro.
- ParannusParannetut Bluetooth-puhelut Pole Pro -laitteelle.
- ParannusVahvempi tuki Bluetooth-tilastojen hakemiseen.
- ParannusRefaktorointi palvelinkutsut.
- ParannusKäännösten parantaminen.
- ParannusParempi luotettavuus ajastetun latauksen muuttamisessa.
- ParannusSovelluksen käynnistyksen nopeutus.
- ParannusParannuksia yhteysasetusten näyttöön.
- KorjausKorjattu PDF-laskujen lataus.
- KorjausKorjattu valkoinen näyttö yhteysasetuksia määritettäessä.
- KorjausKorjattu virhe päivitettäessä paikallisen WiFi-verkon kautta.
- KorjausKorjattu epäjohdonmukaisuus OCPP-yhteydessä: asetus näkyi aktivoituna, vaikka sitä ei ollut otettu käyttöön Bluetoothin kautta.
- KorjausKorjattu virhe, joka koski kustannusten näyttämistä aurinkoenergian tilastojen kaavioissa.
- PoistettuPoistettu kuormituksen tasaus latausliitäntöjen välillä Pole-laitteissa; nyt kuorma tasataan automaattisesti dynaamisen ohjauksen kautta.
-
- UusiSalli e-Chargerin poistaminen, kun Cloud-dynaaminen ohjaus on käytössä ja käyttäjä ei ole ylläpitäjä
- ParannusVältä liian monta pyyntöä päänäytössä, kun käytössä on useita e-Chargereita
- ParannusVirheiden hallinta RFID-korttien tai Bluetooth-avainnippujen muokkauksessa
- PäivitettyPäivitä Denka-laturin vähimmäisteho 1 kW:iin
- PäivitettyPäivitetty kirjastot ja parannettu optimointi
- PäivitettySallitaan yli 100 kW:n tehot latausprofiileissa
- KorjausKorjattu virhe tilastojen lähetyksessä Bluetoothin kautta
- KorjausKorjattu virhe Shelly Pro -laitteen tietojen haussa dynaamisessa säädössä
- KorjausKorjattu virhe, joka ilmeni ensimmäistä latausprofiilia lisättäessä Bluetoothilla
- KorjausKorjattu virhe laskujen latauksessa millä tahansa matkapuhelimella
- KorjausKorjattu valkoisen ruudun virhe Pole-latauspisteen lisäämisen yhteydessä
-
- UusiUusi toiminto: lisätty "Herätystila".
- UusiPoista ilmoitukset käytöstä, kun kirjaudut ulos.
- ParannusParannettu optimointi, nopeampi suorituskyky.
- KorjausKorjattu virhe, joka esti tilastojen hakemisen Bluetoothin kautta aurinkosähkön (PV) erottelun yhteydessä.
- KorjausKorjattu virhe, joka esti raportin päivittymisen, kun ominaisuuteen tehtiin muutoksia.
-
- UusiTilastoissa näkyy kustannus, kun hyödynnetään aurinkosähköä, ja myös säästö näytetään.
- UusiMahdollisuus säätää LED-valon voimakkuutta
- UusiMahdollisuus asettaa DDSU666-H-mittarille toinen COM-osoite
- UusiLisätty Fronius-invertterin tyypit
- UusiUusi Denka e-Charger lisätty
- UusiUudet hinnastot lisätty (Indeksoitu ja OMIE)
- UusiUudet e-Charger Denka -ominaisuudet
- UusiUudet invertterit lisätty
- UusiIlmoitus EcoCharging-toiminnosta aktivoitu
- UusiLisätty EcoCharging-suunnitelman näkymä
- UusiDenka-toimintojen integrointi
- UusiNyt ilmoitukset erotellaan tyypin mukaan, ja käyttäjä voi valita ne haluamallaan tavalla.
- UusiKaikkien uusien näyttöjen käännökset.
- UusiJoitakin vaihtoehtoja on poistettu käytöstä, kun pilvipohjainen dynaaminen ohjaus on käytössä.
- UusiVaroitusviesti OCPP-asetusten muuttamisen yhteydessä.
- UusiLisättiin Deye-invertterityypit dynaamiseen tehonohjaukseen
- UusiLisätty päivämääräsuodatin tapahtumiin.
- UusiLisätty uusi Shelly pro -mittari dynaamiseen tehonhallintaan
- ParannusParannetut ranskankieliset käännökset.
- PäivitettyPäivitys versioon 2.2.7
- PäivitettySähköpostiosoitteen vahvistuslomakkeen lähetys päivitetty
- PäivitettyTekstimuutokset 4G- ja Ethernet-yhteyksille.
- KorjausVirhe korjattu näytettäessä akun latausta gifissä
- KorjausKorjattiin RFID-näytön virhe, jossa näyttö jäi jumiin ja latausta näytettiin loputtomasti.
- KorjausMuutettu kuukausittaisten laskujen tekstiä ja korjattu laskujen oletuskuukausi.
- KorjausKorjattu virhe, joka esiintyi, jos palvelin epäonnistui MAC-osoitteen pyynnössä, ja jos JSON epäonnistui reported-tiedon pyynnössä Bluetoothin kautta.
-
- ParannusParannuksia käännöksiin
- KorjausKorjattu: kellonajan vaihtoon liittyvä ongelma latausprofiilien tuntien muokkauksessa on ratkaistu.
-
- UusiLisätty tyypit Greenheiss-invertteriin ja SAJ-invertteriin
- UusiLisätty ion-range-liukusäädin latausprofiilien tehonvalintaan
- UusiUusia yhteystyyppejä Trydan Pro -laitteelle (4G ja Ethernet)
- UusiLatauslaitteen uudelleenkäynnistysilmoitus Wi-Fi-asetusten yhteydessä
- UusiVirkistetään tilastoja paremman luotettavuuden vuoksi
- UusiPidennys lisätty, jotta e-Key-avain voidaan lisätä luotettavuuden parantamiseksi
- ParannusKäännösten parantaminen
- ParannusParannuksia käyttäjälle näytettäviin viesteihin e-Keys-avaimissa
- PäivitettyVoit lisätä, muokata ja poistaa RFID-kortteja ja e-Keyjä ilman, että niitä tarvitsee aktivoida.
- KorjausKorjattu virhe, jonka vuoksi Pole Pro -laitteessa ei näkynyt ohjelmoitua aikaa.
- KorjausKorjattu aikavyöhykkeen virhe latausprofiileissa (esiintyi pääasiassa Portugalissa)
-
- UusiLuotu uusi ponnahdusikkuna opastusta varten, jota voidaan käyttää, kun käyttäjälle on tarpeen selittää jotakin yksityiskohtaisemmin.
- UusiLatauprofiilien virheenhallinta, joka ilmoittaa käyttäjälle, jos jotain ei ole tallennettu oikein.
- UusiAurinkosähkön yhdistäminen latausprofiileihin Pole Pro -laitteelle.
- UusiBluetooth-yhteyden paikannuksen parannus joissakin puhelimissa, ja näytämme virheilmoituksen, jos Bluetooth-yhteys epäonnistuu.
- UusiLisätty COM 1- ja COM 11 -tyypit Huawei Chint -mittarille dynaamisessa tehonhallinnassa.
- UusiPiilotettu aurinkosähkö-gif Pole Pro -latauspisteille.
- UusiMahdollisuus lisätä vapaa COM-osoite Huawei-invertterille.
- UusiLisätty mahdollisuus määrittää staattinen IP-osoite Pole Pro -laitteelle.
- UusiLisätty uusi viesti GIF-kuvaan, kun aurinkosähköntuotantoa ei ole.
- UusiLisättiin uusia käännöksiä.
- UusiLisätty käyttäjälle tietoa Pole Pro -laitteen staattisen IP-osoitteen asetuksista.
- UusiLisätty 'car topic' MQTT-asetusten määrittämiseen dynaamisessa tehonohjauksessa.
- ParannusSanakirjojen muotoilun parannus (sisäinen koodi).
- ParannusParannus latausprofiilien tallennukseen: latausprofiileja, joissa on yli 5 aikaväliä, ei ole enää mahdollista tallentaa Bluetoothin kautta.
- ParannusYleinen sovelluksen suorituskyvyn parantaminen ja koodin optimointi.
- PäivitettyUusi ilmoitusten hallinta laitekohtaisesti tilillisen sijaan sekä ilmoitusten tilaus pois käytöstä laitteen parin poistamisen yhteydessä.
- PäivitettyVaihdettu Bluetooth-tunnuksen tallennus localStoragesta sessionStorageen, jotta yhteys on vakaampi.
- PäivitettyNimenmuutos: ”Mittari V2C 2.0” korvataan nimellä ”V2C ControlBox”.
- KorjausKorjattu bugi, jossa MQTT-käyttäjätunnus ja salasana lähetettiin dynaamisessa tehonhallinnassa.
- KorjausKorjattu virhe, joka koski tilastojen näyttämistä, kun ne alkoivat kello 00:00.
- KorjausKorjattu virhe kielen vaihdossa: joskus tallennuspainiketta ei näkynyt.
- KorjausKorjattu bugi, jossa Shelly-tyyppi ei välittynyt dynaamisen ohjauksen asetuksiin.
-
- UusiJaa latauslaite Käyttäjien hallinta -valikossa.
- UusiV2C Payments -prosessi avautuu samassa sovelluksessa, mikä tekee maksamisesta käyttäjälle mukavampaa. (Ei toimi, jos käyttäjän matkapuhelimen oletusselaimena on MI-selain, mutta toimii Google Chromella ja Safarilla.)
- UusiLisätty käyttäjälle ilmoitus latauksen jatkamisesta, jos V2C Payments on otettu käyttöön.
- UusiUudet kielet saatavilla Trydanissa.
- UusiDynaamisen tehonohjauksen ja latausprofiilien hallinta Pole Pro -laitteessa.
- UusiLisätty Trydan-yhteensopivuus Enphase-invertterin kanssa.
- UusiLisätty Trydanin yhteensopivuus P1-mittarin kanssa.
- UusiLisätty Trydan-yhteensopivuus Modbus-feeder-mittarin kanssa.
- UusiLisätty uusia lisäasetuksia MQTT:lle.
- UusiErotelma inverttyyppien välillä Solis (akulla tai ilman akkua).
- UusiRomanian-kieli lisätty Trydan-laitteeseen.
- UusiLisätty vaihekartan asetus Pole Prossa kohtaan Erikoisasetukset.
- UusiToteutus DeadLetters-järjestelmään taustalla tapahtuvien käyttäjävirheiden kirjaamista varten.
- UusiPole Pro -tehotasot virran rajoituksella
- UusiLisätty mittarittomaksi vaihtoehto Pole Pron dynaamiseen ohjaukseen.
- UusiTärkeitä huomautuksia dynaamisen säädön muokkaamisesta käyttökokemuksen parantamiseksi.
- UusiUusi näyttö: käytettävissä olevien lisälaitteiden luettelo Pole Prolle, kun se toimii päälaitteena.
- ParannusLataus nopeammin asetuksista offline-tilassa.
- ParannusMerkittävä parannus Bluetooth-avainperien yhteyden vakauteen sekä WiFi- että Bluetooth-yhteyden kautta.
- ParannusParannus erikoisvarusteiden ulkoasuun.
- ParannusParannus Bluetooth-haun ja -yhteyden löytämiseen iOS-laitteilla.
- ParannusParannuksia joihinkin Bluetooth-menetelmiin.
- ParannusParannus käyttökokemukseen e-Chargerin nimeä muokattaessa.
- ParannusParanna Bluetooth-yhteyden vakautta Pole Prossa.
- PäivitettyMuutos kW:stä W:hen akkujen purkauksessa.
- PäivitettyVaihdettu ”Dynaamisen ohjauksen asetukset” muotoon ”Latausprofiilit”.
- PäivitettyNimenmuutos: Bluetooth-avaimenperät kutsutaan nyt nimellä e-Keys.
- PäivitettyBluetooth-skannausajan pidentäminen päänäytössä.
- KorjausKorjattu virhe, joka ilmeni, kun sivu päivitettiin ilman latureita.
- KorjausKorjattu virhe, joka ilmeni joillakin näytöillä, kun palasi takaisin matkapuhelimen takaisin-painikkeella.
- KorjausPäivitetään RFID-korttien tai avaimenperien luettelo niiden aktivoinnin yhteydessä.
- KorjausParannus laskujen näkymään englanniksi.
- KorjausEstä e-Chargerin poistaminen, jos käyttäjä on offline-tilassa.
- KorjausMahdollistaa latauksen käynnistämisen laitteen sisältä, kun automaattinen lukitus on aktivoitu.
- PoistettuPysäköintiviesti poistettu V2C Payments -palvelusta, kun pysäköinti on ilmainen, jotta sekaannuksilta vältytään.
-
- UusiLisätty vaihtoehtoinen mittari SolarEdgelle dynaamisessa ohjauksessa.
- UusiLisätty vahvistus ennen laiteohjelmiston päivittämistä.
- UusiEnemmän ja parempia käännöksiä.
- UusiOhjausvirheiden käsittely maksuissa
- UusiLisätty uusi Google Home -kuva.
- ParannusParannettu yhteyttä ja Wi-Fi-vastaanottoa aloitusnäytössä.
- ParannusNäyttö: asetukset offline-tilassa latautuvat nopeammin.
- PäivitettyYhdistää RFID-korttien aktivoinnin ja muokkauksen yhdeksi näkymäksi. (Sama koskee Bluetooth-avainnippuja.)
- PäivitettyHuawei-tyypin vaihto COM-osoitteeseen.
- PäivitettyLähetä aloitusnäyttöön e-Chargerin uudelleenkäynnistyksen jälkeen.
- PäivitettyMuutan, kun teemme maksutapahtuman ilmaiseksi Paymentsissa.
- PäivitettyÄlä salli maksujen muokkaamista, jos sinulla ei ole internetyhteyttä.
- KorjausKorjattu virhe, jossa Huawei-tyyppinen kysely ilmestyi mille tahansa mittarille tai invertterille.
- KorjausKorjattu virhe, joka esti latauskertojen tilastojen näyttämisen klo 22:00 ja 00:00 välillä tehdyistä latauksista.
- KorjausKorjattu virhe, joka ilmeni, kun tehon aikavälin nimi jätettiin tyhjäksi.
- KorjausKorjattu Payments-virhe ilmaisen tariffin kohdalla.
- KorjausKorjattu aikavyöhykkeeseen liittyvä virhe tilastoissa.
- KorjausKorjattu pieniä virheitä.
-
- UusiTeholuokissa on nyt uusi aurinkosähkötyyppi nimeltä ”Ei syöttöä verkkoon tai saarekekäyttö”.
- UusiTehoportaat tallennetaan palvelimelle ja välimuistiin, jotta ne toimivat oikein millä tahansa laitteella ja missä tahansa tilanteessa. (Internet-yhteydellä, ilman internet-yhteyttä, Bluetoothilla jne.)
- UusiLisätty avainnippuja Bluetooth-toiminnolla Trydan-laitteille.
- UusiLisätty käyttäjälle näytettäviä ohjeviestejä paremman käyttökokemuksen takaamiseksi.
- UusiTunnus pyydetään vain kerran minuutissa tai sovellukseen kirjauduttaessa, ja se tallennetaan välimuistiin nopeuden parantamiseksi (ennen tunnus pyydettiin jokaisella HTTP-kutsulla).
- UusiLisätty mahdollisuus käynnistää e-Charger uudelleen kohdassa "Erikoisasetukset".
- UusiGoogle Home on jo saatavilla, ja sovelluksessa on lisätty vastaavat tiedot.
- UusiLisää virheidenhallintaa joihinkin julkaisuihin, jotta käyttäjälle näkyy selkeämmin, mitä on tapahtunut.
- ParannusParannus Bluetooth-tilastojen hakemiseen ja lähettämiseen.
- ParannusParannus joidenkin Bluetooth-yhteyksien vakauteen
- ParannusParannettu Payments-näyttöjen ulkoasua.
- PäivitettyAurinkosähkön gifissä arvoa ei näytetä, jos tieto on 0 tai tyhjä.
- PäivitettyJos laitteen kieli on euskara, sovellus asetetaan oletuksena espanjaksi (aiemmin se asetettiin englanniksi).
- KorjausKorjattu GIF, joka jäi jumiin joissakin iOS-laitteissa aurinkosähkön sivulla.
- KorjausKorjattiin joitakin pieniä virheitä.
-
- UusiLisätty IP-osoite Wi-Fi-tietoihin.
- UusiOttaen huomioon pysäköintikustannukset latauksen jälkeen V2C Payments -palvelussa.
- UusiStaattisen IP-osoitteen määrittäminen Shelly-laitteelle
- UusiPäivitetään maksujen tila reaaliajassa päänäytöllä.
- UusiUudet invertterit lisätty.
- UusiMuutos Shelly-invertterin hinnoitteluun.
- ParannusParannettu Bluetooth-yhteyden uudelleenmuodostusta päänäytössä iOS-laitteilla.
- ParannusLatauslaitteen lukitsemisessa liu'uttamisen ja napsauttamisen vaihtoehdot on eroteltu toisistaan.
- ParannusParannettu Bluetooth-yhteyden vakautta tietyissä puheluissa, joissa yhteys aiemmin toisinaan katkesi.
- PäivitettyPainikkeen koko maksuissa ilman latureita suurempi.
- PäivitettyKorjattu uusi QR-muoto.
- PäivitettyMahdollisuus muokata OCPP-asetuksia Bluetoothin kautta Trydanissa.
- PäivitettyMuutos V2C Payments -näytön ulkoasussa
- KorjausKorjattu iOS-push-ilmoitukset.
- KorjausKorjattu Google-kirjautumisen ongelma iOS-laitteilla latauspisteen jakamisen yhteydessä.
- KorjausKorjattu virhe PVPC 2 -muodossa.
- KorjausKorjattu virhe tariffien muokkauksessa.
- KorjausKorjattiin virhe maksujen laskujen latauksessa.
-
- UusiUudet invertterit lisätty
- UusiUusi ilmoitus, jos tilastojen hakeminen Bluetoothin kautta onnistui
- UusiNyt sovellusta tarvitaan vain siihen, että Bluetooth on käytössä.
- UusiHuomioi akut fotovoltaiikka-gifissä
- ParannusParempi johdonmukaisuus tiedonsiirrossa Bluetoothin kautta
- ParannusEstä käyttäjää syöttämästä tyhjää RFID-nimeä ja uusia käännöksiä
- KorjausKorjattu Bluetooth-tilastojen haku
- KorjausKorjattu aurinkosähköön liittyvien GIF-kuvien virhe
- KorjausKorjaus ilmoituksiin
V2C Cloud -verkkoportaali
Nykyinen versio 4.1.1 · Versioita: 45, ensimmäinen: joulukuu 2020
- UusiActivate or deactivate the default rate for each e-Charger in Payments.
- UusiEcocharging plan available for Oasys batteries.
- ParannusUpload your own invoices in the Invoices section of Payments.
Aiemmat versiot 44
-
- UusiMandatory location for e-Chargers in Payments.
- UusiMake the charger public from Payments so that it is visible on other platforms.
- UusiAssign a different rate to each group in Payments.
- UusiMonthly fee rate within Collective Charging.
- ParannusNew design for the Payments platform.
- 4.0.4ParannusNew way to configure the Ingeteam inverter.
-
- UusiItalian tariffs.
- 4.0.2UusiRates by periods.
- 4.0.1UusiBattery prioritization in charging profiles.
-
- ParannusNew design of the portal v2c.cloud.
- ParannusSupport for viewing on mobile devices.
-
- UusiNew Sofar Solar inverter.
-
- UusiSelect time zone, manually or automatically.
- UusiNew Huawei Emma inverter.
- UusiNew Azzurro inverter.
- ParannusIncrease in code size on RFID cards.
-
- ParannusNew rates added.
-
- ParannusNew PDFs in Spanish and English in Payments.
- KorjausCharging power limit on Denka.
-
- UusiCharging stops upon reaching the selected percentage for Denka models.
- UusiTPV icon.
- UusiPossibility to see more chargers on the main page.
- UusiCalculator in Payments rates.
- ParannusSelection of the auto-lock time for Trydan with version 2.3.25 or higher.
-
- ParannusChange in design when adding/modifying rates in Payments.
-
- KorjausBug fixes in cloud installation.
-
- KorjausFixing errors in RFID cards.
-
- UusiCatalan language added.
- KorjausBug fixes in the cloud power control.
- 3.2.12KorjausFixing errors in power control profiles and in the meter list.
-
- PäivitettyImprovement in RFID cards to manually support 14 characters.
- 3.2.10KorjausError fixing
-
- UusiFiltering by status (online/offline) available for e-Chargers.
- ParannusVisualization of the e-Chargers version on the homepage.
- 3.2.8ParannusGrouping of types in Payments invoices.
-
- KorjausFix when filtering date range in Payments and dashboard.
-
- ParannusIncrease in the maximum number of power control profiles.
-
- UusiItalian language in Pole Pro.
- PäivitettyOptional OCPP customization properties in Pole Pro.
-
- ParannusCreation of more intuitive power profiles.
-
- ParannusImproved visual aspect when creating power profiles for cloud power control.
- PäivitettyGreater reduction in the cloud power control zoom and the option to reset zoom changed to center the installation.
-
- ParannusAbility to download statistics as a .xlsx file.
- KorjausFixed various minor bugs.
-
- ParannusAdded a waiting indicator when saving an installation in cloud power control.
- PäivitettyModified text and color according to the state of the e-Charger in cloud power control.
- KorjausImages of e-Chargers in installation view in cloud power control.
-
- UusiRight-click menu in cloud power control.
- UusiSelect, copy, paste, duplicate, and delete multiple elements in cloud power control.
- ParannusMove and zoom in on an installation with the mouse wheel in cloud power control.
- PäivitettyThe upper power limit in the charging profiles has been modified.
- KorjausFixed various minor bugs.
-
- UusiAdded Basque language
- ParannusPerformance improvement on the e-Chargers page and control panel
- PäivitettyNew way to display the details of the e-Chargers
- KorjausFixed various minor bugs.
-
- UusiRight-click to delete an active item during the creation or editing of an installation in cloud power control.
- UusiThe customer's email appears when downloading the transaction table from V2C Payments.
- ParannusImproved interaction between elements during the creation or editing of an installation in cloud power control to avoid impossibilities.
- PäivitettyV2C Payments transaction table sorted by date in descending order.
- KorjausFixed various minor bugs.
-
- PäivitettyNew validations when creating rates in V2C Payments.
- KorjausFixed errors in displaying the power control settings.
- 3.1.0UusiNew design of the portal v2c.cloud
-
- ParannusGreater speed also on the main screen, and in the charging of the user's e-Chargers.
- ParannusChange the configuration to parallel for faster data loading.
- PäivitettyAll the inverters and meters available in the App have been added.
- KorjausFixing various bugs, updating and improving translations and user experience.
-
- UusiAdded list of wifi networks
- UusiAdded hamburger menu for better visualization of the canvas in smart charging.
- UusiAdded shared user management
- UusiAdded translations
- UusiAdded user help for CSV download
- UusiRomanian language added
- UusiAdded the partner creation form
- ParannusCharging acceleration of the e-Chargers
- PäivitettyChange the navbar to black
- KorjausFixed issue with the smart charging zoom.
- 2.0.0UusiAdded Smart charging
-
- UusiAdded invitations to customers
- PäivitettyImage tags also translated
-
- UusiAdded to the main screen charger in payment mode or not with icon
- UusiNew translations added
- PäivitettyNew design of the main screen
- KorjausFixed bug with colors changing upon logout
- KorjausInvoice issue, the correct one was not downloading.
- KorjausTransactions are now resolved quickly, and there is a change in the format of the rates.
- KorjausResolved issue in payments with the tabs that were moving.
- KorjausFixed 'Update software' and bug with charger statuses.
-
- UusiAdded Payments option
- UusiInvoices added in the new tab and can be downloaded.
- UusiAdded flat rate or customized rate when adding a rate
- ParannusImprovement in device charging
- ParannusImprovement of designs to make them responsive on all devices
-
- UusiAdded plus charger
- PäivitettyAdd charger in the same way as in the app
- PäivitettyWe show fewer decimals in the tables.
- PäivitettyChange the design of the side menu and some labels.
- PäivitettyRemoved donuts and changed design on the screen up button.
- KorjausBug fixes and design improvements
- KorjausFix letter design and login and main screen
-
- UusiAdded software update in the configuration
- UusiCost calculation according to the rate
- KorjausChanging the rate is done correctly.
- KorjausControlled error changing WiFi without connection
- KorjausEnergy rate calculation is done correctly.
-
- UusiYou can now log in by pressing enter.
- ParannusCharging screen improves without connection
- PäivitettyChange of design if there is no connection
- KorjausDynamic power control is adjusted properly.
- KorjausGlobal statistics are now updating correctly.
- KorjausFixed main screen hours
- KorjausCSV data download in the correct format
-
- UusiNew, more specific errors indicated for the user and installers.
- KorjausBug fixes when linking devices.
-
- ParannusImprovements in website performance.
- KorjausFunctionality bugs fixed.
-
- UusiStyle improvements.
- UusiCreation of the V2C website.
- KorjausBug fixes.