تحديثات Trydan و Trydan Pro
نعمل باستمرار على تحسين ميزات Trydan و Trydan Pro. هنا ستجد أحدث إصدار من شاحننا الإلكتروني e-Charger وآخر التحديثات التي تم تنفيذها.
أحدث إصدار
2.5.2
Trydan و Trydan Pro
2.5.2أحدث إصدار
New inverters (Solplanet/AISWEI, Hoymiles, Huawei without dongle), battery discharge control, unified statistics in mixed three-phase, and cybersecurity improvements in Bluetooth.
- جديدDirect query of OCPP status
- جديدNew Solplanet/AISWEI Inverter
- جديدNew Hoymiles Inverter
- جديدBattery discharge control: GoodWe, SolarEdge
- جديدHuawei inverters direct connection without Dongle
- جديدUnified statistics in mixed three-phase charging (the session is not divided when switching between three-phase and single-phase)
- جديدNew "Unlimited" Wake-up 5 mode available from the LCD
- جديدImprovements in Bluetooth cybersecurity
- تحسينFixes in FV mode + Minimum power
- تحسينOCPP: duplicate BootNotifications are avoided
- تحسينSecurity menu lock during vehicle charging
- تحسينImprovements for Linky-LORA
الإصدارات السابقة 46
-
- جديدCompatibility with SigEnergy inverters
- جديدNew model of Ingeteam three-phase inverter (ISS 3PLAY)
- جديدWiFi connection for Deye inverters via Elfin
- جديدExpansion to 105 RFID cards
- جديدPAP/CHAP authentication for 4G connection
- جديدMore stable OCPP connections
- تحسينReading the P1 and Victron meters is more reliable in the event of communication failures.
- تحسينStability of mixed three-phase charging
- تحسينError reporting and diagnostic system
- تحسينImprovement of home battery charging priority in PV charging modes
-
- جديدManagement of home battery discharge in charging profiles
- جديدUnlocking the Trydan by smartphone proximity
- جديدNew models of SofarSolar and Azzurro inverters
- جديدAdded current and voltage per phase in Home Assistant and Modbus API.
- جديدWiFi connection in Deye inverters
- جديدIncrease of up to 80 RFID cards
- جديدBattery compatibility in SolarEdge inverters
- جديدScroll text for long texts
- تحسينOptimization of Ethernet network interface
- تحسينImprovements in the Modbus TCP client
- تحسينImprovements in mixed three-phase charging
- تحسينImprovement of texts in German
- تحسينIncrease the voltage range of the installation from the control panel.
-
- إصلاحOCPP password bug
- إصلاحProblems connecting to CSMS after restarts
-
- جديدTarget charge kWh
- جديدNew SMA Sunny Boy model
- جديدNew Fronius model with battery
- جديدSelect Modbus API address ID
- جديدNew Deye models
- جديدSofar Solar inverters
- جديدAzzurro inverters
- جديدSelect MID address
- جديدEMMA Huawei
- جديدSecurity Profile 2 OCPP (wss + auth + CA cert)
- جديدPrivate 4G SIMs in OCPP
- جديدOcppFreeMode
- جديدOCPP internal queue messages
- تحسينTime synchronization
- تحسينPower plate measurements 1.0
- تحسينWiFi improvements
- إصلاحExclusive mode bug with batteries
- إصلاحCoordinate "ContractedPower" and load profiles with HTTP API.
- إصلاحImprove RFID errors
- إصلاحMixed load bug
- إصلاحBug photovoltaic mode + minimum
- إصلاحBug statistics without FV via BLE
-
- جديدMIFARE Ultralight RFID cards
- تحسينMore robust OTA update
- إصلاحBug management autolock with payments mode
- إصلاحBug in payments mode with RFID
-
- تحسينInstallation problem readings
- تحسينImprovement in BYD mode
- إصلاحBug with Wibeee inverter
-
- جديدObtain firmware version via Modbus
- جديدGoodWe via Modbus TCP
- جديدOCPP: FirmwareManagement
- جديدAutolock
- جديدNew MID models
- جديدNew wake-up modes
- جديدAllow changing the charging type in HA (single-phase, three-phase, or mixed)
- جديدLinky meter for French meters
- جديدModbus termination resistance
- جديدReading individual properties HTTP API
- جديدTurn off/Turn on logo and LCD from HTTP API
- تحديثImprovements in dynamic control
- تحديثImprovement in Sungrow inverter measurements
- تحديثImprovements in the OTA update
- تحديثImprovements in the button panel menu
- تحديثNew Deye models
- تحديثOCPP: improvement in MeterValues
- تحديثOCPP: send StatusNotification "Faulted" with errors and warnings
- تحديثOCPP: publish current version
- تحديثOCPP: BootNotification timeout
- تحديثNew NTP servers
- تحديثImproved WI-FI scanning
- تحديثImprovement in P1 meter
- تحديثImprovement in remote logs
- تحديثIoT call limitation per charger
- تحديثImprove RAM memory
- تحديثStability via Ethernet
- تحديثCorrected translations
- إصلاحError "Waiting for Power"
- إصلاحBug with RFID cards with long names
- إصلاحBug when requesting the list of Wi-Fi SSIDs via Bluetooth.
- إصلاحImprove statistics via Bluetooth
- إصلاحLocal balancing improvements for up to 10 devices
- إصلاحBug when sending RFID code in the statistics
- إصلاحBug with Exclusive PV mode and batteries
-
- جديدStatic power control is added (only with Trydan consumption).
- جديدMixed charging adapts to European rates.
- جديدPower control programming with phase limits is allowed.
- جديدThe power control adapts to European countries with phase current limits.
- تحديثThe power control algorithm has been modified step by step to apply PID modulation.
- تحديثThe static power control between sockets or between e-Chargers is improved.
- إصلاحThe failure of remote records is avoided when a disconnection occurs.
-
- إصلاحBug DTSU666-G meters
-
- تحسينImprovement in Wake Mode
- إصلاحFixed bug when changing the port in MQTT.
-
- جديدEcoCharging to schedule charging automatically during the cheapest daylight hours.
- جديدTurning on and off LEDs via Modbus TCP/RTU. Option to adjust and query the intensity of the LEDs and the LCD screen.
- جديدCompatibility with the new Chint DTSU666-G meter model, allowing for broader integration in various installations.
- جديدFirmware update of the V2C ControlBox meter (2.0) via the access point (AP) and the mobile app.
- جديدImprovement in the reading of electrical signals: State F detection implemented, enhancing the system's ability to recognize and respond to different operating conditions.
- جديدImprovement in the reading of electrical signals: The reading of the input PWM signal has been implemented using DMA (Direct Memory Access), enhancing efficiency and reducing processing load.
- جديدOCPP: Detailed reasons for OCPP functions, providing more comprehensive information about the actions taken and facilitating the diagnosis and analysis of events.
- جديدOCPP: The ability to operate in offline modes, allowing the charger to function correctly even without a connection to the server. Pending messages are stored and sent once the connection is restored, ensuring reliable and consistent communication.
- جديدOCPP: New OCPP state machine. Now, the system connects to the OCPP Central Server (CS) and receives most commands, improving interoperability and remote control.
- تحسينReading the power value of the batteries in Goodwe EH and ET inverters.
- تحسينSystem optimization: reduction of RAM usage, improving overall system stability and performance.
- تحسينImprovement in the reading of electrical signals: Enhanced verification for state E, in addition to omitting zero values from the DMA to avoid incorrect readings.
- تحسينImprovement in reading electrical signals: Now the CP (Control Pilot) signal is read using a parallel task, which enhances the accuracy and response of the system when interacting with the electric vehicle.
- تحسينImprovement in the reading of electrical signals: Enhanced stability during this calibration process through the app.
- تحسينOCPP: Host name resolution. Optimization of libraries to improve DNS resolution and the reliability of secure connections via Secure WebSocket (WSS), increasing stability in communication with remote servers.
- تحسينOCPP: Ensuring that all important information reaches the server once the connection is restored through a persistent message queue.
- تحسينOCPP: Status notifications. Improving communication with the central server for sending status notifications.
- إصلاحOCPP: Fixed a false card detection alert that appeared when starting the system, avoiding confusion and improving the user experience.
-
- جديدVoltage reading and writing manual for installation for Modbus TCP and HTTP integrations.
- جديدSAJ hybrid inverters
- جديدShelly Pro meters
- جديدInformation on the response /RealtimeData from http at the request of the developer of the official HA integration.
- جديدDirect methods to activate the access point (WiFi AP) and ping a specific IP.
- جديدTopic trydan_v2c_voltage to write the installation voltage via MQTT.
- تحسينLeak detection
- تحسينMemory management to avoid unexpected restarts with OCPP and the deletion of scheduled power profiles.
- تحسينModbus TCP connections of Trydan and Trydan Pro with Huawei, Fronius, Victron, Ingeteam, SolarEdge, Kostal Plenticore, SMA, and SAJ Hybrid in error 252.
- تحسينVisualization of the RFID card authentication process in OCPP
- تحسينThe memory used in JSON and OCPP goes to the SPI RAM.
- إصلاحInformation about RFID cards to the OCPP platform standard for compatibility with platforms like E-flux, Monta…
- إصلاحCollision between the SPI elements (RFID, Ethernet, and GPIO extender) of Trydan Pro
-
- جديدAdaptation of OCPP to new central systems
- جديدNew Deye models
- تحسينImprovements in the direction detection of the V2C 2.0 control box
- إصلاحLEDs blink when there is no connection.
- إصلاحBug in Greenheiss hybrid
-
- جديدDeye / Turbo Energy three-phase
- جديدShelly Pro EM and Shelly Pro 3EM (Beta)
- تحسينShow text on bidirectional meters
- تحسينReadings with Fronius and DTSU666
- تحسينReaction times in the leak detector
- تحسينShow Waiting for Charge in Stop mode
- إصلاحBug with French language
- إصلاحRaise the HTTP server via Ethernet
- إصلاحBug in payments
- إصلاحRead-only in the OCPP properties
- إصلاحSave power segments via Bluetooth on some devices.
- إصلاحShelly Portugal measurements
-
- جديدLive Remote Logs
- تحسينShow stop due to dynamic control
- تحسينRestarts due to reconnection attempts
- تحسينQA Protocol
- تحسينVoltage and Temperature Reading Power PCB
- إصلاحNaN measurement on some meters
- إصلاحError in Home Wizard readings
-
- تحسينPerformance improvement and future compatibility between Trydan and Trydan Pro.
- تحسينImprovements in OCPP protocol
- تحسينImprovements in the QA process
- تحسينImprovement in memory usage
- تحسينMore robust statistics
-
- جديدNetworks with WPA3 security
- جديدNew BLE (NimBLE)
- جديدe-keys via BLE connection
- جديدNew language: Romanian
- جديدEnphase version 7.x.x, Solis with batteries
- جديدAdaptation of the i2c power board
- تحسينAzure library update
- تحسينUpdate of ESP-IDF and Arduino-ESP32 libraries
- تحسينInvestor communication via WiFi connection without Internet
- تحسينImprovement in V2C 2.0 meter refresh rate
- تحسينImprovement in OCPP, adaptation to support disconnections
- تحسينImprovement in key fob detection
- تحسينImproved refresh rate
- تحسينImprovement of values in Huawei, improvement of Chint in Huawei, and end of charge review.
- إصلاحModification of Deye/Turbo Energy batteries
- إصلاحCustomizable MQTT topics and username/password
- إصلاحDisconnection statistics report
- إصلاحBLE compatibility of iPhone
- إصلاحOperation of V2C 2.0 meter at night
- إصلاحAutomatic date and time
- إصلاحInteraction with Megane
-
- جديدBug in photovoltaic three-phase mode
- تحسينWiFi recovery routine
-
- جديدMixed three-phase charging available through the physical menu.
- جديدAdded three-phase MID Meter
- جديدInclusion of server ID 2 in SolarEdge inverters
- جديدAdded Modbus registers with the meter measurement.
- جديدHTTP commands added for integration with HA.
- جديدEnphase Envoy Inverter (beta) (versions 5.x.x)
- جديدV2C 2.0 error detection of clamp not connected
- جديدMQTT Slave with user/password authentication and customizable topics (beta)
- تحسينImprovement of the WatchDog to prevent system freezing
- تحسينImprovement of nearby WiFi scanning
- تحسينBluetoothLE service reconnection protocol
- تحسينWiFi optimization IRAM and affinity with the Azure task
- تحسينReconnection protocol in the absence of WiFi
- تحسينFactory reset
- تحسينThe error code and LED interface
- تحسينImproved the Isolated Installation mode and zero feed-in.
- تحسينReduction in cut-off time through dynamic control to 1 min
- تحسينAutomatic detection of time and time zone
- تحسينThe optimization and refactoring of the measurement slaves
- تحسينUnlocking with BLE Tag
- إصلاحOccasional LCD freezes
- إصلاحFalse positives from the leak detector
- إصلاحProblems with the MID Meter
- إصلاحLED error during update
- إصلاحDefault value for JSON type variables
- إصلاحMeasurement at 0 in Deye/TurboEnergy Inverter
- إصلاحVisual errors and local balancing address assignment
-
- جديدSolar Discount on Shortcuts
- جديدDeye/TurboEnergy Inverter Beta
- جديدPhoenix Contact meter
- جديدCarlo Gavazzi meter
- تحسينOCPP improvements and tested in MONTA
- تحسينProblems in dynamic control
- تحسينReconnections and WiFi Stability
- إصلاحFrozen LCD
-
- جديدIsolated Mode in Photovoltaic Modes
- جديدDutch, Danish, and Valencian
- جديدLeak sensor modes (installer menu)
- جديدMID meter (installer menu)
- جديدNew Ingeteam protocol (Battery Management)
- جديدThree-phase meters DTSU666
- جديدSDM three-phase meters
- تحسينLocal Balancing Protocol and priorities
- تحسينDetection of ports and hosts in OCPP
- تحسينStable version of SMA Sunny Boy
- تحسينPortuguese version of Wibeee
- تحسينFronius measuring home consumption
- إصلاحUnexpected locks and unlocks
- إصلاحWhite blinking in locked mode removed
- إصلاحError selecting the slaves in beta
- إصلاحError of SolarEdge three-phase inverters
-
- جديدChanges and improvements in calibration
-
- تحسينCalibration adapted to the new hardware
- إصلاحData analysis in Kostal Piko fixed
-
- جديدLocal balancing between Trydans available via WiFi or wired connection.
- جديدSDM-220/320/120 (Tested with the Eastron brand)
- جديدDDSU-666 Meter (Common in Huawei installations)
- جديدSelf-calibrating without the need for a car
- جديدManual hour available
- جديدHTTP requests to manage the logs
- جديدNew Modbus Registers
- جديدGreenheiss inverters
- جديدSAJ inverters
- جديدWired Solis inverters
- جديدResponse time in configurable dynamic control
- تحسينConfigurable installation voltage
- تحسينNew manufacturing process
- تحسينIncluded Shelly three-phase but without FV measurement.
- تحسينCar consumption via MQTT fixed
- تحسينImproved and more intuitive physical menu
- التوافقBeta models of Goodwe: the battery measurement is canceled.
- إصلاحBug in Max and Min Intensity via Modbus fixed.
- إصلاحFalse positives in the leak detector fixed
-
- جديدPrevention of conflicts between slaves and the cloud
- إصلاحGoodWe conflicts and Azure initialization
- إصلاحFix in Shelly with only three-phase.
-
- تحسينPending statistics will be sent only once.
- تحسينShelly 3EM three-phase and modification for Portugal
- إصلاحModbus Multiple Readings Hotfix
-
- جديدNew Modbus registers
- جديدRFID reader in alpha version
- جديدSolaX X3 híbrido compatible
- جديدAvailable calibration and shortcuts via WiFi
- تحسينOCPP Improvements
- تحسينImprovement in WiFi scanning
- تحسينImprovement in reconnection routines
- إصلاحBluetooth timezone failure
- إصلاحError in Trydan synchronization - APP
- إصلاحStatic IP configuration in Trydan via WiFi
- إصلاحError saving Modbus parameters
-
- جديدNew method for calibrating communication with the car
- جديدBeta version of the GoodWe ET/EH/BT/BH
- تحسينImprovement in the communication analysis with the car
-
- جديدAuto lock after 60 seconds without a car (shortcut)
- جديدModification for Three-Phase Installations in Portugal for V2C 2.0
- جديدKostal Piko is added.
- تحسينReformulation of the Dynamic Control Algorithm
- تحسينImprovement in the refresh rate of Huawei inverters
- تحسينSolarEdge stable (Meter measuring export)
- تحسينStable version of GoodWe
- تحسينDetection of state D and E according to protocol
- تحسينImproved QA process
- إصلاحStored in memory after writings via Modbus TCP and RTU
- إصلاحBug in the FV measurements and peaks resolved for V2C 2.0
-
- جديدGoodWe in beta version
- جديدCheck the charging status to avoid short charges (Car at 100% or on scheduled charging)
- تحسينMQTT in stable version
- تحسينVictron in stable version
- تحسينImproved connection with Azure
-
- جديدMQTT slave beta version
- تحسينDetection of power direction in Wibeee
- إصلاحThe Victron and SolarEdge inverters were bringing down the system.
-
- جديدSolarEdge inverter added (Beta)
- جديدVictron inverter added (Beta)
- جديدAutolock enabled in shortcut (60 s)
- جديدAutomatic time zone detection
- جديدAlternative meter for car consumption (RS485)
- جديدFV Exclusive with configurable variation
- جديدNew Languages (French, Italian, and German)
- إصلاحFixed error in minimum power mode.
-
- تحسينImprovements in Dynamic Control with batteries
- تحسينImprovements in Dynamic Control in Three-Phase Installations (Exclusive Mode and Minimum Power)
- إصلاحResolved the IP configuration issues for Trydan with WiFi and BLE.
- إصلاحResolved the issues with the IP configuration of Shelly BLE.
-
- جديدInclusion of the Wibeee meter
- جديدSlave 2.0 compatible with Type 1 and Type 2 installation
- جديدChange in the established connection blinking
- جديدDetection and measurement of bifacial load
- جديدImprovement in the collection and transmission of charging data
- جديدAlternative Meter Phoenix Contact (ModbusRTU)
- جديدModbusRTU in Trydan (simultaneous slave and master)
- جديدStatic IP configuration in Trydan
- جديدPossibility to select the IP in Shelly
- تحسينInclusion of maximum intensity in OCPP (as a property)
- تحسينImprovement in the reading of Solax inverters
- تحسينInclusion of batteries in Huawei, Ingeteam, and Fronius inverters.
- تحسينModbusRTU and Modbus TCP server in Trydan
- تحديثFirst stable version of Ingeteam
- تحديثImprovement in the speed of the leak detector
-
- إصلاحError solution in manufacturing when saving WiFi
-
- جديدEliminate false communication errors from the slaves.
- جديدSave the first Shelly that Trydan connects to.
- تحديثWith dynamic control disabled, maintain intensity after finishProgramedSaveMode.
-
- تحسينImprovement in telemetry recovery in OCPP
- تحسينImprovement in scanning nearby WiFi networks
-
- جديدInternal Azure ping every 15 seconds to detect disconnections.
- جديدSeparate reconnections to avoid crashing the server.
- جديدOCPP adaptation to work with Home Assistant
- تحسينMigration of the I2C for the clock and LCD to native idf
-
- تحسينIncrease maximum binary size in local webServer
- إصلاحRecovery of OCPP transactions to prevent telemetry failures
-
- جديدThe configuration of different IDs for Huawei inverters is added.
- تحسينCorrection of the power reading of the house
- إصلاحCorrection of the lock due to Payment Mode and OCPP after deactivation of these.
-
- جديدPayment Method (V2C Payments)
- جديدOCPP Protocol
- تحسينImprovement of WiFi and Bluetooth stability and reconnection
- إصلاحReconnection improvement in the inverters and fix after the update of the Huawei SUN2000.
-
- إصلاحCorrection of the maximum file size for updates on Local Server
-
- جديدList of available WiFi networks from Trydan (for viewing from iPhone and Android)
- تحسينReconnection with V2C Cloud after communication loss
- إصلاحCorrected Shelly and Solax routines
-
- جديدShortcuts on the buttons: Lock and Charging Schedule
- جديدLocal Web page for configuring the Trydan accessible via AP or STA WiFi
- جديدAP mode when the configured WiFi is not available
- تحسينImprovement in LED error codes
- تحسينAdaptation for compatibility with Huawei inverters
-
- جديدWe added connectivity with Fronius inverters.
- تحسينImprovements in screen writing and removal of strange characters
- تحسينImprovement in the transmission of statistics via both WiFi and BLE.
-
- جديدError correction x and y
6 من 46