Actualitzacions per a Trydan i Trydan Pro
Treballem de manera contínua per millorar les funcionalitats de Trydan i Trydan Pro. Aquí trobaràs la versió més recent del nostre e-Charger i les últimes actualitzacions que s'han dut a terme.
Última versió
2.5.2
Trydan i Trydan Pro
2.5.2Última versió
New inverters (Solplanet/AISWEI, Hoymiles, Huawei without dongle), battery discharge control, unified statistics in mixed three-phase, and cybersecurity improvements in Bluetooth.
- NouDirect query of OCPP status
- NouNew Solplanet/AISWEI Inverter
- NouNew Hoymiles Inverter
- NouBattery discharge control: GoodWe, SolarEdge
- NouHuawei inverters direct connection without Dongle
- NouUnified statistics in mixed three-phase charging (the session is not divided when switching between three-phase and single-phase)
- NouNew "Unlimited" Wake-up 5 mode available from the LCD
- NouImprovements in Bluetooth cybersecurity
- MilloraFixes in FV mode + Minimum power
- MilloraOCPP: duplicate BootNotifications are avoided
- MilloraSecurity menu lock during vehicle charging
- MilloraImprovements for Linky-LORA
Versions anteriors 46
-
- NouCompatibility with SigEnergy inverters
- NouNew model of Ingeteam three-phase inverter (ISS 3PLAY)
- NouWiFi connection for Deye inverters via Elfin
- NouExpansion to 105 RFID cards
- NouPAP/CHAP authentication for 4G connection
- NouMore stable OCPP connections
- MilloraReading the P1 and Victron meters is more reliable in the event of communication failures.
- MilloraStability of mixed three-phase charging
- MilloraError reporting and diagnostic system
- MilloraImprovement of home battery charging priority in PV charging modes
-
- NouManagement of home battery discharge in charging profiles
- NouUnlocking the Trydan by smartphone proximity
- NouNew models of SofarSolar and Azzurro inverters
- NouAdded current and voltage per phase in Home Assistant and Modbus API.
- NouWiFi connection in Deye inverters
- NouIncrease of up to 80 RFID cards
- NouBattery compatibility in SolarEdge inverters
- NouScroll text for long texts
- MilloraOptimization of Ethernet network interface
- MilloraImprovements in the Modbus TCP client
- MilloraImprovements in mixed three-phase charging
- MilloraImprovement of texts in German
- MilloraIncrease the voltage range of the installation from the control panel.
-
- CorreccióOCPP password bug
- CorreccióProblems connecting to CSMS after restarts
-
- NouTarget charge kWh
- NouNew SMA Sunny Boy model
- NouNew Fronius model with battery
- NouSelect Modbus API address ID
- NouNew Deye models
- NouSofar Solar inverters
- NouAzzurro inverters
- NouSelect MID address
- NouEMMA Huawei
- NouSecurity Profile 2 OCPP (wss + auth + CA cert)
- NouPrivate 4G SIMs in OCPP
- NouOcppFreeMode
- NouOCPP internal queue messages
- MilloraTime synchronization
- MilloraPower plate measurements 1.0
- MilloraWiFi improvements
- CorreccióExclusive mode bug with batteries
- CorreccióCoordinate "ContractedPower" and load profiles with HTTP API.
- CorreccióImprove RFID errors
- CorreccióMixed load bug
- CorreccióBug photovoltaic mode + minimum
- CorreccióBug statistics without FV via BLE
-
- NouMIFARE Ultralight RFID cards
- MilloraMore robust OTA update
- CorreccióBug management autolock with payments mode
- CorreccióBug in payments mode with RFID
-
- MilloraInstallation problem readings
- MilloraImprovement in BYD mode
- CorreccióBug with Wibeee inverter
-
- NouObtain firmware version via Modbus
- NouGoodWe via Modbus TCP
- NouOCPP: FirmwareManagement
- NouAutolock
- NouNew MID models
- NouNew wake-up modes
- NouAllow changing the charging type in HA (single-phase, three-phase, or mixed)
- NouLinky meter for French meters
- NouModbus termination resistance
- NouReading individual properties HTTP API
- NouTurn off/Turn on logo and LCD from HTTP API
- ActualitzatImprovements in dynamic control
- ActualitzatImprovement in Sungrow inverter measurements
- ActualitzatImprovements in the OTA update
- ActualitzatImprovements in the button panel menu
- ActualitzatNew Deye models
- ActualitzatOCPP: improvement in MeterValues
- ActualitzatOCPP: send StatusNotification "Faulted" with errors and warnings
- ActualitzatOCPP: publish current version
- ActualitzatOCPP: BootNotification timeout
- ActualitzatNew NTP servers
- ActualitzatImproved WI-FI scanning
- ActualitzatImprovement in P1 meter
- ActualitzatImprovement in remote logs
- ActualitzatIoT call limitation per charger
- ActualitzatImprove RAM memory
- ActualitzatStability via Ethernet
- ActualitzatCorrected translations
- CorreccióError "Waiting for Power"
- CorreccióBug with RFID cards with long names
- CorreccióBug when requesting the list of Wi-Fi SSIDs via Bluetooth.
- CorreccióImprove statistics via Bluetooth
- CorreccióLocal balancing improvements for up to 10 devices
- CorreccióBug when sending RFID code in the statistics
- CorreccióBug with Exclusive PV mode and batteries
-
- NouStatic power control is added (only with Trydan consumption).
- NouMixed charging adapts to European rates.
- NouPower control programming with phase limits is allowed.
- NouThe power control adapts to European countries with phase current limits.
- ActualitzatThe power control algorithm has been modified step by step to apply PID modulation.
- ActualitzatThe static power control between sockets or between e-Chargers is improved.
- CorreccióThe failure of remote records is avoided when a disconnection occurs.
-
- CorreccióBug DTSU666-G meters
-
- MilloraImprovement in Wake Mode
- CorreccióFixed bug when changing the port in MQTT.
-
- NouEcoCharging to schedule charging automatically during the cheapest daylight hours.
- NouTurning on and off LEDs via Modbus TCP/RTU. Option to adjust and query the intensity of the LEDs and the LCD screen.
- NouCompatibility with the new Chint DTSU666-G meter model, allowing for broader integration in various installations.
- NouFirmware update of the V2C ControlBox meter (2.0) via the access point (AP) and the mobile app.
- NouImprovement in the reading of electrical signals: State F detection implemented, enhancing the system's ability to recognize and respond to different operating conditions.
- NouImprovement in the reading of electrical signals: The reading of the input PWM signal has been implemented using DMA (Direct Memory Access), enhancing efficiency and reducing processing load.
- NouOCPP: Detailed reasons for OCPP functions, providing more comprehensive information about the actions taken and facilitating the diagnosis and analysis of events.
- NouOCPP: The ability to operate in offline modes, allowing the charger to function correctly even without a connection to the server. Pending messages are stored and sent once the connection is restored, ensuring reliable and consistent communication.
- NouOCPP: New OCPP state machine. Now, the system connects to the OCPP Central Server (CS) and receives most commands, improving interoperability and remote control.
- MilloraReading the power value of the batteries in Goodwe EH and ET inverters.
- MilloraSystem optimization: reduction of RAM usage, improving overall system stability and performance.
- MilloraImprovement in the reading of electrical signals: Enhanced verification for state E, in addition to omitting zero values from the DMA to avoid incorrect readings.
- MilloraImprovement in reading electrical signals: Now the CP (Control Pilot) signal is read using a parallel task, which enhances the accuracy and response of the system when interacting with the electric vehicle.
- MilloraImprovement in the reading of electrical signals: Enhanced stability during this calibration process through the app.
- MilloraOCPP: Host name resolution. Optimization of libraries to improve DNS resolution and the reliability of secure connections via Secure WebSocket (WSS), increasing stability in communication with remote servers.
- MilloraOCPP: Ensuring that all important information reaches the server once the connection is restored through a persistent message queue.
- MilloraOCPP: Status notifications. Improving communication with the central server for sending status notifications.
- CorreccióOCPP: Fixed a false card detection alert that appeared when starting the system, avoiding confusion and improving the user experience.
-
- NouVoltage reading and writing manual for installation for Modbus TCP and HTTP integrations.
- NouSAJ hybrid inverters
- NouShelly Pro meters
- NouInformation on the response /RealtimeData from http at the request of the developer of the official HA integration.
- NouDirect methods to activate the access point (WiFi AP) and ping a specific IP.
- NouTopic trydan_v2c_voltage to write the installation voltage via MQTT.
- MilloraLeak detection
- MilloraMemory management to avoid unexpected restarts with OCPP and the deletion of scheduled power profiles.
- MilloraModbus TCP connections of Trydan and Trydan Pro with Huawei, Fronius, Victron, Ingeteam, SolarEdge, Kostal Plenticore, SMA, and SAJ Hybrid in error 252.
- MilloraVisualization of the RFID card authentication process in OCPP
- MilloraThe memory used in JSON and OCPP goes to the SPI RAM.
- CorreccióInformation about RFID cards to the OCPP platform standard for compatibility with platforms like E-flux, Monta…
- CorreccióCollision between the SPI elements (RFID, Ethernet, and GPIO extender) of Trydan Pro
-
- NouAdaptation of OCPP to new central systems
- NouNew Deye models
- MilloraImprovements in the direction detection of the V2C 2.0 control box
- CorreccióLEDs blink when there is no connection.
- CorreccióBug in Greenheiss hybrid
-
- NouDeye / Turbo Energy three-phase
- NouShelly Pro EM and Shelly Pro 3EM (Beta)
- MilloraShow text on bidirectional meters
- MilloraReadings with Fronius and DTSU666
- MilloraReaction times in the leak detector
- MilloraShow Waiting for Charge in Stop mode
- CorreccióBug with French language
- CorreccióRaise the HTTP server via Ethernet
- CorreccióBug in payments
- CorreccióRead-only in the OCPP properties
- CorreccióSave power segments via Bluetooth on some devices.
- CorreccióShelly Portugal measurements
-
- NouLive Remote Logs
- MilloraShow stop due to dynamic control
- MilloraRestarts due to reconnection attempts
- MilloraQA Protocol
- MilloraVoltage and Temperature Reading Power PCB
- CorreccióNaN measurement on some meters
- CorreccióError in Home Wizard readings
-
- MilloraPerformance improvement and future compatibility between Trydan and Trydan Pro.
- MilloraImprovements in OCPP protocol
- MilloraImprovements in the QA process
- MilloraImprovement in memory usage
- MilloraMore robust statistics
-
- NouNetworks with WPA3 security
- NouNew BLE (NimBLE)
- Noue-keys via BLE connection
- NouNew language: Romanian
- NouEnphase version 7.x.x, Solis with batteries
- NouAdaptation of the i2c power board
- MilloraAzure library update
- MilloraUpdate of ESP-IDF and Arduino-ESP32 libraries
- MilloraInvestor communication via WiFi connection without Internet
- MilloraImprovement in V2C 2.0 meter refresh rate
- MilloraImprovement in OCPP, adaptation to support disconnections
- MilloraImprovement in key fob detection
- MilloraImproved refresh rate
- MilloraImprovement of values in Huawei, improvement of Chint in Huawei, and end of charge review.
- CorreccióModification of Deye/Turbo Energy batteries
- CorreccióCustomizable MQTT topics and username/password
- CorreccióDisconnection statistics report
- CorreccióBLE compatibility of iPhone
- CorreccióOperation of V2C 2.0 meter at night
- CorreccióAutomatic date and time
- CorreccióInteraction with Megane
-
- NouBug in photovoltaic three-phase mode
- MilloraWiFi recovery routine
-
- NouMixed three-phase charging available through the physical menu.
- NouAdded three-phase MID Meter
- NouInclusion of server ID 2 in SolarEdge inverters
- NouAdded Modbus registers with the meter measurement.
- NouHTTP commands added for integration with HA.
- NouEnphase Envoy Inverter (beta) (versions 5.x.x)
- NouV2C 2.0 error detection of clamp not connected
- NouMQTT Slave with user/password authentication and customizable topics (beta)
- MilloraImprovement of the WatchDog to prevent system freezing
- MilloraImprovement of nearby WiFi scanning
- MilloraBluetoothLE service reconnection protocol
- MilloraWiFi optimization IRAM and affinity with the Azure task
- MilloraReconnection protocol in the absence of WiFi
- MilloraFactory reset
- MilloraThe error code and LED interface
- MilloraImproved the Isolated Installation mode and zero feed-in.
- MilloraReduction in cut-off time through dynamic control to 1 min
- MilloraAutomatic detection of time and time zone
- MilloraThe optimization and refactoring of the measurement slaves
- MilloraUnlocking with BLE Tag
- CorreccióOccasional LCD freezes
- CorreccióFalse positives from the leak detector
- CorreccióProblems with the MID Meter
- CorreccióLED error during update
- CorreccióDefault value for JSON type variables
- CorreccióMeasurement at 0 in Deye/TurboEnergy Inverter
- CorreccióVisual errors and local balancing address assignment
-
- NouSolar Discount on Shortcuts
- NouDeye/TurboEnergy Inverter Beta
- NouPhoenix Contact meter
- NouCarlo Gavazzi meter
- MilloraOCPP improvements and tested in MONTA
- MilloraProblems in dynamic control
- MilloraReconnections and WiFi Stability
- CorreccióFrozen LCD
-
- NouIsolated Mode in Photovoltaic Modes
- NouDutch, Danish, and Valencian
- NouLeak sensor modes (installer menu)
- NouMID meter (installer menu)
- NouNew Ingeteam protocol (Battery Management)
- NouThree-phase meters DTSU666
- NouSDM three-phase meters
- MilloraLocal Balancing Protocol and priorities
- MilloraDetection of ports and hosts in OCPP
- MilloraStable version of SMA Sunny Boy
- MilloraPortuguese version of Wibeee
- MilloraFronius measuring home consumption
- CorreccióUnexpected locks and unlocks
- CorreccióWhite blinking in locked mode removed
- CorreccióError selecting the slaves in beta
- CorreccióError of SolarEdge three-phase inverters
-
- NouChanges and improvements in calibration
-
- MilloraCalibration adapted to the new hardware
- CorreccióData analysis in Kostal Piko fixed
-
- NouLocal balancing between Trydans available via WiFi or wired connection.
- NouSDM-220/320/120 (Tested with the Eastron brand)
- NouDDSU-666 Meter (Common in Huawei installations)
- NouSelf-calibrating without the need for a car
- NouManual hour available
- NouHTTP requests to manage the logs
- NouNew Modbus Registers
- NouGreenheiss inverters
- NouSAJ inverters
- NouWired Solis inverters
- NouResponse time in configurable dynamic control
- MilloraConfigurable installation voltage
- MilloraNew manufacturing process
- MilloraIncluded Shelly three-phase but without FV measurement.
- MilloraCar consumption via MQTT fixed
- MilloraImproved and more intuitive physical menu
- CompatibilitatBeta models of Goodwe: the battery measurement is canceled.
- CorreccióBug in Max and Min Intensity via Modbus fixed.
- CorreccióFalse positives in the leak detector fixed
-
- NouPrevention of conflicts between slaves and the cloud
- CorreccióGoodWe conflicts and Azure initialization
- CorreccióFix in Shelly with only three-phase.
-
- MilloraPending statistics will be sent only once.
- MilloraShelly 3EM three-phase and modification for Portugal
- CorreccióModbus Multiple Readings Hotfix
-
- NouNew Modbus registers
- NouRFID reader in alpha version
- NouSolaX X3 híbrido compatible
- NouAvailable calibration and shortcuts via WiFi
- MilloraOCPP Improvements
- MilloraImprovement in WiFi scanning
- MilloraImprovement in reconnection routines
- CorreccióBluetooth timezone failure
- CorreccióError in Trydan synchronization - APP
- CorreccióStatic IP configuration in Trydan via WiFi
- CorreccióError saving Modbus parameters
-
- NouNew method for calibrating communication with the car
- NouBeta version of the GoodWe ET/EH/BT/BH
- MilloraImprovement in the communication analysis with the car
-
- NouAuto lock after 60 seconds without a car (shortcut)
- NouModification for Three-Phase Installations in Portugal for V2C 2.0
- NouKostal Piko is added.
- MilloraReformulation of the Dynamic Control Algorithm
- MilloraImprovement in the refresh rate of Huawei inverters
- MilloraSolarEdge stable (Meter measuring export)
- MilloraStable version of GoodWe
- MilloraDetection of state D and E according to protocol
- MilloraImproved QA process
- CorreccióStored in memory after writings via Modbus TCP and RTU
- CorreccióBug in the FV measurements and peaks resolved for V2C 2.0
-
- NouGoodWe in beta version
- NouCheck the charging status to avoid short charges (Car at 100% or on scheduled charging)
- MilloraMQTT in stable version
- MilloraVictron in stable version
- MilloraImproved connection with Azure
-
- NouMQTT slave beta version
- MilloraDetection of power direction in Wibeee
- CorreccióThe Victron and SolarEdge inverters were bringing down the system.
-
- NouSolarEdge inverter added (Beta)
- NouVictron inverter added (Beta)
- NouAutolock enabled in shortcut (60 s)
- NouAutomatic time zone detection
- NouAlternative meter for car consumption (RS485)
- NouFV Exclusive with configurable variation
- NouNew Languages (French, Italian, and German)
- CorreccióFixed error in minimum power mode.
-
- MilloraImprovements in Dynamic Control with batteries
- MilloraImprovements in Dynamic Control in Three-Phase Installations (Exclusive Mode and Minimum Power)
- CorreccióResolved the IP configuration issues for Trydan with WiFi and BLE.
- CorreccióResolved the issues with the IP configuration of Shelly BLE.
-
- NouInclusion of the Wibeee meter
- NouSlave 2.0 compatible with Type 1 and Type 2 installation
- NouChange in the established connection blinking
- NouDetection and measurement of bifacial load
- NouImprovement in the collection and transmission of charging data
- NouAlternative Meter Phoenix Contact (ModbusRTU)
- NouModbusRTU in Trydan (simultaneous slave and master)
- NouStatic IP configuration in Trydan
- NouPossibility to select the IP in Shelly
- MilloraInclusion of maximum intensity in OCPP (as a property)
- MilloraImprovement in the reading of Solax inverters
- MilloraInclusion of batteries in Huawei, Ingeteam, and Fronius inverters.
- MilloraModbusRTU and Modbus TCP server in Trydan
- ActualitzatFirst stable version of Ingeteam
- ActualitzatImprovement in the speed of the leak detector
-
- CorreccióError solution in manufacturing when saving WiFi
-
- NouEliminate false communication errors from the slaves.
- NouSave the first Shelly that Trydan connects to.
- ActualitzatWith dynamic control disabled, maintain intensity after finishProgramedSaveMode.
-
- MilloraImprovement in telemetry recovery in OCPP
- MilloraImprovement in scanning nearby WiFi networks
-
- NouInternal Azure ping every 15 seconds to detect disconnections.
- NouSeparate reconnections to avoid crashing the server.
- NouOCPP adaptation to work with Home Assistant
- MilloraMigration of the I2C for the clock and LCD to native idf
-
- MilloraIncrease maximum binary size in local webServer
- CorreccióRecovery of OCPP transactions to prevent telemetry failures
-
- NouThe configuration of different IDs for Huawei inverters is added.
- MilloraCorrection of the power reading of the house
- CorreccióCorrection of the lock due to Payment Mode and OCPP after deactivation of these.
-
- NouPayment Method (V2C Payments)
- NouOCPP Protocol
- MilloraImprovement of WiFi and Bluetooth stability and reconnection
- CorreccióReconnection improvement in the inverters and fix after the update of the Huawei SUN2000.
-
- CorreccióCorrection of the maximum file size for updates on Local Server
-
- NouList of available WiFi networks from Trydan (for viewing from iPhone and Android)
- MilloraReconnection with V2C Cloud after communication loss
- CorreccióCorrected Shelly and Solax routines
-
- NouShortcuts on the buttons: Lock and Charging Schedule
- NouLocal Web page for configuring the Trydan accessible via AP or STA WiFi
- NouAP mode when the configured WiFi is not available
- MilloraImprovement in LED error codes
- MilloraAdaptation for compatibility with Huawei inverters
-
- NouWe added connectivity with Fronius inverters.
- MilloraImprovements in screen writing and removal of strange characters
- MilloraImprovement in the transmission of statistics via both WiFi and BLE.
-
- NouError correction x and y
6 de 46