Updates für Trydan und Trydan Pro
Wir arbeiten kontinuierlich daran, die Funktionen von Trydan und Trydan Pro zu verbessern. Hier finden sich die neueste Version unserer Wallbox und die zuletzt veröffentlichten Updates.
Neueste Version
2.5.2
Trydan und Trydan Pro
2.5.2Neueste Version
New inverters (Solplanet/AISWEI, Hoymiles, Huawei without dongle), battery discharge control, unified statistics in mixed three-phase, and cybersecurity improvements in Bluetooth.
- NeuDirect query of OCPP status
- NeuNew Solplanet/AISWEI Inverter
- NeuNew Hoymiles Inverter
- NeuBattery discharge control: GoodWe, SolarEdge
- NeuHuawei inverters direct connection without Dongle
- NeuUnified statistics in mixed three-phase charging (the session is not divided when switching between three-phase and single-phase)
- NeuNew "Unlimited" Wake-up 5 mode available from the LCD
- NeuImprovements in Bluetooth cybersecurity
- VerbessertFixes in FV mode + Minimum power
- VerbessertOCPP: duplicate BootNotifications are avoided
- VerbessertSecurity menu lock during vehicle charging
- VerbessertImprovements for Linky-LORA
Frühere Versionen 46
-
- NeuCompatibility with SigEnergy inverters
- NeuNew model of Ingeteam three-phase inverter (ISS 3PLAY)
- NeuWiFi connection for Deye inverters via Elfin
- NeuExpansion to 105 RFID cards
- NeuPAP/CHAP authentication for 4G connection
- NeuMore stable OCPP connections
- VerbessertReading the P1 and Victron meters is more reliable in the event of communication failures.
- VerbessertStability of mixed three-phase charging
- VerbessertError reporting and diagnostic system
- VerbessertImprovement of home battery charging priority in PV charging modes
-
- NeuManagement of home battery discharge in charging profiles
- NeuUnlocking the Trydan by smartphone proximity
- NeuNew models of SofarSolar and Azzurro inverters
- NeuAdded current and voltage per phase in Home Assistant and Modbus API.
- NeuWiFi connection in Deye inverters
- NeuIncrease of up to 80 RFID cards
- NeuBattery compatibility in SolarEdge inverters
- NeuScroll text for long texts
- VerbessertOptimization of Ethernet network interface
- VerbessertImprovements in the Modbus TCP client
- VerbessertImprovements in mixed three-phase charging
- VerbessertImprovement of texts in German
- VerbessertIncrease the voltage range of the installation from the control panel.
-
- BehobenOCPP password bug
- BehobenProblems connecting to CSMS after restarts
-
- NeuTarget charge kWh
- NeuNew SMA Sunny Boy model
- NeuNew Fronius model with battery
- NeuSelect Modbus API address ID
- NeuNew Deye models
- NeuSofar Solar inverters
- NeuAzzurro inverters
- NeuSelect MID address
- NeuEMMA Huawei
- NeuSecurity Profile 2 OCPP (wss + auth + CA cert)
- NeuPrivate 4G SIMs in OCPP
- NeuOcppFreeMode
- NeuOCPP internal queue messages
- VerbessertTime synchronization
- VerbessertPower plate measurements 1.0
- VerbessertWiFi improvements
- BehobenExclusive mode bug with batteries
- BehobenCoordinate "ContractedPower" and load profiles with HTTP API.
- BehobenImprove RFID errors
- BehobenMixed load bug
- BehobenBug photovoltaic mode + minimum
- BehobenBug statistics without FV via BLE
-
- NeuMIFARE Ultralight RFID cards
- VerbessertMore robust OTA update
- BehobenBug management autolock with payments mode
- BehobenBug in payments mode with RFID
-
- VerbessertInstallation problem readings
- VerbessertImprovement in BYD mode
- BehobenBug with Wibeee inverter
-
- NeuObtain firmware version via Modbus
- NeuGoodWe via Modbus TCP
- NeuOCPP: FirmwareManagement
- NeuAutolock
- NeuNew MID models
- NeuNew wake-up modes
- NeuAllow changing the charging type in HA (single-phase, three-phase, or mixed)
- NeuLinky meter for French meters
- NeuModbus termination resistance
- NeuReading individual properties HTTP API
- NeuTurn off/Turn on logo and LCD from HTTP API
- AktualisiertImprovements in dynamic control
- AktualisiertImprovement in Sungrow inverter measurements
- AktualisiertImprovements in the OTA update
- AktualisiertImprovements in the button panel menu
- AktualisiertNew Deye models
- AktualisiertOCPP: improvement in MeterValues
- AktualisiertOCPP: send StatusNotification "Faulted" with errors and warnings
- AktualisiertOCPP: publish current version
- AktualisiertOCPP: BootNotification timeout
- AktualisiertNew NTP servers
- AktualisiertImproved WI-FI scanning
- AktualisiertImprovement in P1 meter
- AktualisiertImprovement in remote logs
- AktualisiertIoT call limitation per charger
- AktualisiertImprove RAM memory
- AktualisiertStability via Ethernet
- AktualisiertCorrected translations
- BehobenError "Waiting for Power"
- BehobenBug with RFID cards with long names
- BehobenBug when requesting the list of Wi-Fi SSIDs via Bluetooth.
- BehobenImprove statistics via Bluetooth
- BehobenLocal balancing improvements for up to 10 devices
- BehobenBug when sending RFID code in the statistics
- BehobenBug with Exclusive PV mode and batteries
-
- NeuStatic power control is added (only with Trydan consumption).
- NeuMixed charging adapts to European rates.
- NeuPower control programming with phase limits is allowed.
- NeuThe power control adapts to European countries with phase current limits.
- AktualisiertThe power control algorithm has been modified step by step to apply PID modulation.
- AktualisiertThe static power control between sockets or between e-Chargers is improved.
- BehobenThe failure of remote records is avoided when a disconnection occurs.
-
- BehobenBug DTSU666-G meters
-
- VerbessertImprovement in Wake Mode
- BehobenFixed bug when changing the port in MQTT.
-
- NeuEcoCharging to schedule charging automatically during the cheapest daylight hours.
- NeuTurning on and off LEDs via Modbus TCP/RTU. Option to adjust and query the intensity of the LEDs and the LCD screen.
- NeuCompatibility with the new Chint DTSU666-G meter model, allowing for broader integration in various installations.
- NeuFirmware update of the V2C ControlBox meter (2.0) via the access point (AP) and the mobile app.
- NeuImprovement in the reading of electrical signals: State F detection implemented, enhancing the system's ability to recognize and respond to different operating conditions.
- NeuImprovement in the reading of electrical signals: The reading of the input PWM signal has been implemented using DMA (Direct Memory Access), enhancing efficiency and reducing processing load.
- NeuOCPP: Detailed reasons for OCPP functions, providing more comprehensive information about the actions taken and facilitating the diagnosis and analysis of events.
- NeuOCPP: The ability to operate in offline modes, allowing the charger to function correctly even without a connection to the server. Pending messages are stored and sent once the connection is restored, ensuring reliable and consistent communication.
- NeuOCPP: New OCPP state machine. Now, the system connects to the OCPP Central Server (CS) and receives most commands, improving interoperability and remote control.
- VerbessertReading the power value of the batteries in Goodwe EH and ET inverters.
- VerbessertSystem optimization: reduction of RAM usage, improving overall system stability and performance.
- VerbessertImprovement in the reading of electrical signals: Enhanced verification for state E, in addition to omitting zero values from the DMA to avoid incorrect readings.
- VerbessertImprovement in reading electrical signals: Now the CP (Control Pilot) signal is read using a parallel task, which enhances the accuracy and response of the system when interacting with the electric vehicle.
- VerbessertImprovement in the reading of electrical signals: Enhanced stability during this calibration process through the app.
- VerbessertOCPP: Host name resolution. Optimization of libraries to improve DNS resolution and the reliability of secure connections via Secure WebSocket (WSS), increasing stability in communication with remote servers.
- VerbessertOCPP: Ensuring that all important information reaches the server once the connection is restored through a persistent message queue.
- VerbessertOCPP: Status notifications. Improving communication with the central server for sending status notifications.
- BehobenOCPP: Fixed a false card detection alert that appeared when starting the system, avoiding confusion and improving the user experience.
-
- NeuVoltage reading and writing manual for installation for Modbus TCP and HTTP integrations.
- NeuSAJ hybrid inverters
- NeuShelly Pro meters
- NeuInformation on the response /RealtimeData from http at the request of the developer of the official HA integration.
- NeuDirect methods to activate the access point (WiFi AP) and ping a specific IP.
- NeuTopic trydan_v2c_voltage to write the installation voltage via MQTT.
- VerbessertLeak detection
- VerbessertMemory management to avoid unexpected restarts with OCPP and the deletion of scheduled power profiles.
- VerbessertModbus TCP connections of Trydan and Trydan Pro with Huawei, Fronius, Victron, Ingeteam, SolarEdge, Kostal Plenticore, SMA, and SAJ Hybrid in error 252.
- VerbessertVisualization of the RFID card authentication process in OCPP
- VerbessertThe memory used in JSON and OCPP goes to the SPI RAM.
- BehobenInformation about RFID cards to the OCPP platform standard for compatibility with platforms like E-flux, Monta…
- BehobenCollision between the SPI elements (RFID, Ethernet, and GPIO extender) of Trydan Pro
-
- NeuAdaptation of OCPP to new central systems
- NeuNew Deye models
- VerbessertImprovements in the direction detection of the V2C 2.0 control box
- BehobenLEDs blink when there is no connection.
- BehobenBug in Greenheiss hybrid
-
- NeuDeye / Turbo Energy three-phase
- NeuShelly Pro EM and Shelly Pro 3EM (Beta)
- VerbessertShow text on bidirectional meters
- VerbessertReadings with Fronius and DTSU666
- VerbessertReaction times in the leak detector
- VerbessertShow Waiting for Charge in Stop mode
- BehobenBug with French language
- BehobenRaise the HTTP server via Ethernet
- BehobenBug in payments
- BehobenRead-only in the OCPP properties
- BehobenSave power segments via Bluetooth on some devices.
- BehobenShelly Portugal measurements
-
- NeuLive Remote Logs
- VerbessertShow stop due to dynamic control
- VerbessertRestarts due to reconnection attempts
- VerbessertQA Protocol
- VerbessertVoltage and Temperature Reading Power PCB
- BehobenNaN measurement on some meters
- BehobenError in Home Wizard readings
-
- VerbessertPerformance improvement and future compatibility between Trydan and Trydan Pro.
- VerbessertImprovements in OCPP protocol
- VerbessertImprovements in the QA process
- VerbessertImprovement in memory usage
- VerbessertMore robust statistics
-
- NeuNetworks with WPA3 security
- NeuNew BLE (NimBLE)
- Neue-keys via BLE connection
- NeuNew language: Romanian
- NeuEnphase version 7.x.x, Solis with batteries
- NeuAdaptation of the i2c power board
- VerbessertAzure library update
- VerbessertUpdate of ESP-IDF and Arduino-ESP32 libraries
- VerbessertInvestor communication via WiFi connection without Internet
- VerbessertImprovement in V2C 2.0 meter refresh rate
- VerbessertImprovement in OCPP, adaptation to support disconnections
- VerbessertImprovement in key fob detection
- VerbessertImproved refresh rate
- VerbessertImprovement of values in Huawei, improvement of Chint in Huawei, and end of charge review.
- BehobenModification of Deye/Turbo Energy batteries
- BehobenCustomizable MQTT topics and username/password
- BehobenDisconnection statistics report
- BehobenBLE compatibility of iPhone
- BehobenOperation of V2C 2.0 meter at night
- BehobenAutomatic date and time
- BehobenInteraction with Megane
-
- NeuBug in photovoltaic three-phase mode
- VerbessertWiFi recovery routine
-
- NeuMixed three-phase charging available through the physical menu.
- NeuAdded three-phase MID Meter
- NeuInclusion of server ID 2 in SolarEdge inverters
- NeuAdded Modbus registers with the meter measurement.
- NeuHTTP commands added for integration with HA.
- NeuEnphase Envoy Inverter (beta) (versions 5.x.x)
- NeuV2C 2.0 error detection of clamp not connected
- NeuMQTT Slave with user/password authentication and customizable topics (beta)
- VerbessertImprovement of the WatchDog to prevent system freezing
- VerbessertImprovement of nearby WiFi scanning
- VerbessertBluetoothLE service reconnection protocol
- VerbessertWiFi optimization IRAM and affinity with the Azure task
- VerbessertReconnection protocol in the absence of WiFi
- VerbessertFactory reset
- VerbessertThe error code and LED interface
- VerbessertImproved the Isolated Installation mode and zero feed-in.
- VerbessertReduction in cut-off time through dynamic control to 1 min
- VerbessertAutomatic detection of time and time zone
- VerbessertThe optimization and refactoring of the measurement slaves
- VerbessertUnlocking with BLE Tag
- BehobenOccasional LCD freezes
- BehobenFalse positives from the leak detector
- BehobenProblems with the MID Meter
- BehobenLED error during update
- BehobenDefault value for JSON type variables
- BehobenMeasurement at 0 in Deye/TurboEnergy Inverter
- BehobenVisual errors and local balancing address assignment
-
- NeuSolar Discount on Shortcuts
- NeuDeye/TurboEnergy Inverter Beta
- NeuPhoenix Contact meter
- NeuCarlo Gavazzi meter
- VerbessertOCPP improvements and tested in MONTA
- VerbessertProblems in dynamic control
- VerbessertReconnections and WiFi Stability
- BehobenFrozen LCD
-
- NeuIsolated Mode in Photovoltaic Modes
- NeuDutch, Danish, and Valencian
- NeuLeak sensor modes (installer menu)
- NeuMID meter (installer menu)
- NeuNew Ingeteam protocol (Battery Management)
- NeuThree-phase meters DTSU666
- NeuSDM three-phase meters
- VerbessertLocal Balancing Protocol and priorities
- VerbessertDetection of ports and hosts in OCPP
- VerbessertStable version of SMA Sunny Boy
- VerbessertPortuguese version of Wibeee
- VerbessertFronius measuring home consumption
- BehobenUnexpected locks and unlocks
- BehobenWhite blinking in locked mode removed
- BehobenError selecting the slaves in beta
- BehobenError of SolarEdge three-phase inverters
-
- NeuChanges and improvements in calibration
-
- VerbessertCalibration adapted to the new hardware
- BehobenData analysis in Kostal Piko fixed
-
- NeuLocal balancing between Trydans available via WiFi or wired connection.
- NeuSDM-220/320/120 (Tested with the Eastron brand)
- NeuDDSU-666 Meter (Common in Huawei installations)
- NeuSelf-calibrating without the need for a car
- NeuManual hour available
- NeuHTTP requests to manage the logs
- NeuNew Modbus Registers
- NeuGreenheiss inverters
- NeuSAJ inverters
- NeuWired Solis inverters
- NeuResponse time in configurable dynamic control
- VerbessertConfigurable installation voltage
- VerbessertNew manufacturing process
- VerbessertIncluded Shelly three-phase but without FV measurement.
- VerbessertCar consumption via MQTT fixed
- VerbessertImproved and more intuitive physical menu
- KompatibilitätBeta models of Goodwe: the battery measurement is canceled.
- BehobenBug in Max and Min Intensity via Modbus fixed.
- BehobenFalse positives in the leak detector fixed
-
- NeuPrevention of conflicts between slaves and the cloud
- BehobenGoodWe conflicts and Azure initialization
- BehobenFix in Shelly with only three-phase.
-
- VerbessertPending statistics will be sent only once.
- VerbessertShelly 3EM three-phase and modification for Portugal
- BehobenModbus Multiple Readings Hotfix
-
- NeuNew Modbus registers
- NeuRFID reader in alpha version
- NeuSolaX X3 híbrido compatible
- NeuAvailable calibration and shortcuts via WiFi
- VerbessertOCPP Improvements
- VerbessertImprovement in WiFi scanning
- VerbessertImprovement in reconnection routines
- BehobenBluetooth timezone failure
- BehobenError in Trydan synchronization - APP
- BehobenStatic IP configuration in Trydan via WiFi
- BehobenError saving Modbus parameters
-
- NeuNew method for calibrating communication with the car
- NeuBeta version of the GoodWe ET/EH/BT/BH
- VerbessertImprovement in the communication analysis with the car
-
- NeuAuto lock after 60 seconds without a car (shortcut)
- NeuModification for Three-Phase Installations in Portugal for V2C 2.0
- NeuKostal Piko is added.
- VerbessertReformulation of the Dynamic Control Algorithm
- VerbessertImprovement in the refresh rate of Huawei inverters
- VerbessertSolarEdge stable (Meter measuring export)
- VerbessertStable version of GoodWe
- VerbessertDetection of state D and E according to protocol
- VerbessertImproved QA process
- BehobenStored in memory after writings via Modbus TCP and RTU
- BehobenBug in the FV measurements and peaks resolved for V2C 2.0
-
- NeuGoodWe in beta version
- NeuCheck the charging status to avoid short charges (Car at 100% or on scheduled charging)
- VerbessertMQTT in stable version
- VerbessertVictron in stable version
- VerbessertImproved connection with Azure
-
- NeuMQTT slave beta version
- VerbessertDetection of power direction in Wibeee
- BehobenThe Victron and SolarEdge inverters were bringing down the system.
-
- NeuSolarEdge inverter added (Beta)
- NeuVictron inverter added (Beta)
- NeuAutolock enabled in shortcut (60 s)
- NeuAutomatic time zone detection
- NeuAlternative meter for car consumption (RS485)
- NeuFV Exclusive with configurable variation
- NeuNew Languages (French, Italian, and German)
- BehobenFixed error in minimum power mode.
-
- VerbessertImprovements in Dynamic Control with batteries
- VerbessertImprovements in Dynamic Control in Three-Phase Installations (Exclusive Mode and Minimum Power)
- BehobenResolved the IP configuration issues for Trydan with WiFi and BLE.
- BehobenResolved the issues with the IP configuration of Shelly BLE.
-
- NeuInclusion of the Wibeee meter
- NeuSlave 2.0 compatible with Type 1 and Type 2 installation
- NeuChange in the established connection blinking
- NeuDetection and measurement of bifacial load
- NeuImprovement in the collection and transmission of charging data
- NeuAlternative Meter Phoenix Contact (ModbusRTU)
- NeuModbusRTU in Trydan (simultaneous slave and master)
- NeuStatic IP configuration in Trydan
- NeuPossibility to select the IP in Shelly
- VerbessertInclusion of maximum intensity in OCPP (as a property)
- VerbessertImprovement in the reading of Solax inverters
- VerbessertInclusion of batteries in Huawei, Ingeteam, and Fronius inverters.
- VerbessertModbusRTU and Modbus TCP server in Trydan
- AktualisiertFirst stable version of Ingeteam
- AktualisiertImprovement in the speed of the leak detector
-
- BehobenError solution in manufacturing when saving WiFi
-
- NeuEliminate false communication errors from the slaves.
- NeuSave the first Shelly that Trydan connects to.
- AktualisiertWith dynamic control disabled, maintain intensity after finishProgramedSaveMode.
-
- VerbessertImprovement in telemetry recovery in OCPP
- VerbessertImprovement in scanning nearby WiFi networks
-
- NeuInternal Azure ping every 15 seconds to detect disconnections.
- NeuSeparate reconnections to avoid crashing the server.
- NeuOCPP adaptation to work with Home Assistant
- VerbessertMigration of the I2C for the clock and LCD to native idf
-
- VerbessertIncrease maximum binary size in local webServer
- BehobenRecovery of OCPP transactions to prevent telemetry failures
-
- NeuThe configuration of different IDs for Huawei inverters is added.
- VerbessertCorrection of the power reading of the house
- BehobenCorrection of the lock due to Payment Mode and OCPP after deactivation of these.
-
- NeuPayment Method (V2C Payments)
- NeuOCPP Protocol
- VerbessertImprovement of WiFi and Bluetooth stability and reconnection
- BehobenReconnection improvement in the inverters and fix after the update of the Huawei SUN2000.
-
- BehobenCorrection of the maximum file size for updates on Local Server
-
- NeuList of available WiFi networks from Trydan (for viewing from iPhone and Android)
- VerbessertReconnection with V2C Cloud after communication loss
- BehobenCorrected Shelly and Solax routines
-
- NeuShortcuts on the buttons: Lock and Charging Schedule
- NeuLocal Web page for configuring the Trydan accessible via AP or STA WiFi
- NeuAP mode when the configured WiFi is not available
- VerbessertImprovement in LED error codes
- VerbessertAdaptation for compatibility with Huawei inverters
-
- NeuWe added connectivity with Fronius inverters.
- VerbessertImprovements in screen writing and removal of strange characters
- VerbessertImprovement in the transmission of statistics via both WiFi and BLE.
-
- NeuError correction x and y
6 von 46