Uppdateringar för Pole Pro
Vi arbetar kontinuerligt med att förbättra funktionerna i Pole Pro. Här hittar du den senaste versionen av vår e-Charger och de senaste uppdateringarna som har genomförts.
Senaste versionen
6.1.3
Pole Pro
Har du den tidigare Pole? Se dess uppdateringar.
6.1.3Senaste versionen
- ÅtgärdadThe charger no longer hangs when rebooting while shutting down the 4G module or dynamic power control
Tidigare versioner 46
- 6.1.2ÅtgärdadOCPP security event notifications are no longer sent when the connection uses no security profile (profile 0), since some central systems do not support them
-
- ÅtgärdadCorrected default APN for Wireless Logic SIM cards in Belgium
-
- NyAudible buzzer feedback
- NySupport for registering multiple RFID cards
- NyReading of the installation meter over Modbus RS485 on DC chargers
- NyDynamic power control for DC installations — master and slave units now share and honor the installation power limit
- NyLive display of actual consumption versus offered current on the charger screen
- NyOn-screen guidance walks the user through registering an RFID card
- NyOCPP connection password can now be set from the Cloud and Bluetooth
- NyOCPP now supports security profiles, encrypted TLS connections and Basic Authentication for the central system
- FörbättradLanguage codes standardized to the ISO 639-1 format
- FörbättradReduced volume of messages sent to the Cloud
- FörbättradTime synchronization with the CSMS no longer floods the system log
- FörbättradLog rotation no longer loses history when the disk is full
- FörbättradSafer firmware updates
- FörbättradMore reliable connectivity with automatic failover between Ethernet and 4G
- FörbättradCharges history now loads page by page instead of the whole history at once, for a faster tab
- ÅtgärdadMeasurer error message now reads clearly
- ÅtgärdadMore accurate meter-reading validation
- ÅtgärdadCharge metrics are preserved if a charge is interrupted unexpectedly
- ÅtgärdadScreen orientation set in configuration is now applied correctly
- ÅtgärdadFree-charge mode could not be disabled from the installer panel
- ÅtgärdadDynamic power limit was not applied at tariff/hour boundaries, briefly leaving an installation without a limit
- ÅtgärdadResolved random service restarts (crashes) caused by network device discovery
-
- FörbättradMore reliable RFID card reading with optimized antenna configuration from first use
- FörbättradImproved stability and responsiveness of the charger's web interface
-
- NyOCPP - Immediate "Preparing" status when receiving a remote start command via OCPP
- NyWiFi disabled by default on devices without WiFi configured
- FörbättradMore reliable RFID card reading with periodic reader reinitialization
- FörbättradBetter cable connection detection and RFID timeout handling
- FörbättradCDP - More stable network device discovery, preventing unnecessary register/unregister cycles
- FörbättradImproved stability when applying configuration changes to the charger
- FörbättradAutomatic migration of legacy pending OCPP messages after update
- FörbättradImproved network handling when switching between manual and automatic IP configuration
- ÅtgärdadPower factor value conversion for Carlo Gavazzi meters
- ÅtgärdadImprovements in power measurement accuracy in single-phase or two-phase installations
- ÅtgärdadOCPP - Smart Charging profiles with defined duration now applied correctly
- ÅtgärdadOCPP - Local authentication cache overflow that could prevent charging sessions from startIing
- ÅtgärdadOCPP - OCPP transactions stuck due to unreleased semaphores or null keys
-
- NyEnhanced web server for accessing and editing charger properties
- NyVisual improvements to the web server interface
- NyPersistent price display on screen when the payment system is active
- NyRefined error reporting to the cloud
- NyPower loss detection
- NyWi-Fi disable option from the installer panel
- NyNew buzzer system implementation for white boards
- FörbättradEnhanced RFID calibration with on-screen indicator during the process
- FörbättradRFID reader no longer forcibly activates when OCPP or Payments are active; explicit configuration is respected
- FörbättradRefined cable connect/disconnect notification on each event when payments are active
- FörbättradOptimized RFID card readings
- FörbättradOCPP - Improvements to the offline transaction queue
- FörbättradInternal connection optimization and overall performance improvements
- ÅtgärdadOCPP - Improved measurement value reporting
- ÅtgärdadRefined out-of-range measurement error detection
-
- NySoftware-level leak detection enable/disable
- FörbättradAdjusted cooldown time between charges when a leak is detected
- FörbättradOCPP - Improvements to the offline transaction queue
-
- FörbättradWhen OCPP is active, we now show on screen when card passed is not registered in central system.
- ÅtgärdadAfter update OCPP image and QR is now recovered.
-
- ÅtgärdadFixed issue where it didn't allow a remote start if a car is connected but not in an active transaction.
- ÅtgärdadFixed issue in setup interface.
- ÅtgärdadFixed monophasic Carlo Gavazzi measurer.
- ÅtgärdadFixed OCPP issue where it wouldn't charge in connector 2 if connector 1 is charging.
-
- FörbättradImproved network features mainly 4G connection.
-
- FörbättradImproved OCPP charge handling.
- FörbättradEnhanced reliability in the smart charging logic.
- FörbättradImproved features when stopping a charge with invalid identifiers.
- FörbättradImproved QR configuration for OCPP.
- FörbättradImproved error handling when sensors or communication components fail.
- FörbättradBetter log management to prevent the device’s storage from filling up.
- FörbättradImproved USB connection features.
- FörbättradImproved RFID calibration and detection display.
- FörbättradImproved features related to Bluetooth.
- FörbättradImproved dynamic power control allowing charge at minimum intensity if master is not detected.
-
- NyManual timezone setting is now available – The user will be able to configure the timezone even if automatic detection is disabled
- NyCreated a contingency page in case app is not running
- NyAdded Italian option for screen
- NyAdded default payment QR to pay without app
- NyAdded new OCPP personalization options - The user can now set 2 QR codes on the screen
- FörbättradImproved updater
- FörbättradImproved network connections
- FörbättradImproved OCPP meter values
- FörbättradImproved discovering devices when dynamic control is active
- FörbättradImproved user interface when updates are in progress
- FörbättradLocal load balancing is now implemented as dynamic control based specific conditions
- FörbättradImproved Bluetooth connection
- FörbättradImproved 4g connections robustness
- FörbättradImproved STM32 lock timings
- FörbättradImproved OCPP now allows external intensity limits
- FörbättradImproved data consumption
- ÅtgärdadWhen locking a connector while charging, it now sends end charge telemetry correctly
- ÅtgärdadFixed dynamic control issues
- ÅtgärdadFixed Carlo Gavazzi power meter
- ÅtgärdadFixed OCPP LMS, diagnostics, and charging profile clearing
-
- NyAdded shared library
- NyTimezone can be set manually
- NyTime is now synced with Central System if OCPP is active
- FörbättradImproved version/update manager
- FörbättradImproved megabyte conversion of Network Monitor
- FörbättradObtaining timezone now doesn't need to have correct time by using only http urls
- FörbättradMobile usb device name is now obtained dynamically since more usb ports might be used due to TPV
- ÅtgärdadFixed power control issues
- ÅtgärdadFixed that when locking connector during a charge it now ends correctly
- ÅtgärdadRecalculate reboot time when changing time with ble
- ÅtgärdadWe now show on screen when non registered RFID is passed while OCPP is active
- ÅtgärdadFixed OCPP freemode rfid issues
- ÅtgärdadDuplicate StatusNotifications are removed from offline queue
- ÅtgärdadFixed "infinite" OCPP offline queue issue
-
- NyAPN can now be set manually
- FörbättradWe now show on screen different wifi images depending on how strong signal is to let know the user how good the connection is
- FörbättradGeneral OCPP improvements: we check connection to CS instead of internet for local functioning, we notify a real value now when there's a stop transaction due to power loss, fixed edge cases where connectivity is lost, new ocpp key MaxEVCurrentOffered implemented which limits charge with key instead of smart charging handler, safety mechanisms for ocpp to be more robust
- FörbättradIn 4g, increased rssi range for "excellent" so that it indicates correctly when the reception is good
- FörbättradImproved data consumption
- FörbättradImproved robustness of update
- UppdateradAccess point time increased to 15 minutes
- ÅtgärdadHandled issues when SSID has whitespace
-
- ÅtgärdadAccess point improvements.
- ÅtgärdadFixed QA issues.
-
- NyNew direct method to obtain additional information for Smart Charging.
- NyFixed random reboot time.
- FörbättradFixed unset RFID.
- FörbättradFixed Unknown measurer and made distinction between Unknown measurer and wrongly configured measurer.
- FörbättradOCPP Free mode can be toggled through OCPP keys.
- UppdateradFixed BLE connection with iphone and fixed bluetooth communication error that appeared on app.
- UppdateradNetwork improvements. No interface resets performed at boot which improves bootup time. Network changes now don't require reboot. When changing WIFI settings or ip ethernet settings, it connects after setting it instead of rebooting.
- ÅtgärdadFixed issue where things on screen were missing in one connector chargers.
- ÅtgärdadFixed time/timezone issue caused when the date is off by a few days.
- ÅtgärdadNew property added to toggle if vehicle should be able to charge even though measurers aren't working ( Only works when OCPP, payments or dynamic control isn't enabled ).
-
- NyReflect on screen when charge is paused.
- NyMade reboot time random.
- ÅtgärdadIncreased SAS token time to live of azure.
-
- NyChanges made to reduce network usage that can be toggled on or off.
- NyFixed case where config is corrupted or missing and would give trouble at startup.
- NyWe now send dead letter if cpu gets too hot and cpu temperature is now logged.
- FörbättradFixed OCPP inverted measurer error.
- FörbättradAdded mechanism to disable or enable Wifi and bluetooth.
- FörbättradWe now report information regarding which type of connection to the internet the e-charger has.
- UppdateradChanged led colors. Switched State A (now white) and State B (now green) colors.
- ÅtgärdadFixed set threshold values and neopixel leds of Stm32. We can now also obtain control pilot value from Stm32.
- ÅtgärdadOCPP ConnectionTimeOut value can now be changed on the fly.
- ÅtgärdadWe now report iccid of sim card is connected. If sim is connected but we can't obtain iccid, we send dead letter.
- ÅtgärdadFixed log download of http interface.
-
- NyLTE signal is now reflected correctly instead of always showing great signal.
- FörbättradFixed wathdog reboot after doing hard reset.
-
- NyAdded dynamic photovoltaic.
- NyAdded dead letters: measurer fails and kernel error.
- NyProperty "wifi_info" is now reported.
- NyProperty "wifi_static" can be set through ble.
- NyWe can now obtain statistics through direct method.
- NyAdded individual log level for each type of logger.
- NyAdded neopixel led type for stm32.
- NyWe can now set threshold values with stm32 and get control pilot value if debug log of "Stm32" is activated.
- FörbättradImprovements in dynamic control, fabrication, QA, Azure, OCPP, config handling, 4g, access point and stm32.
- FörbättradWe now obtain timezone through url.
- FörbättradRemoved raspbian logo and desktop during boot and added V2C logo.
- FörbättradChanged default language after fabrication from english to spanish.
- UppdateradGeneral bug fixes.
- ÅtgärdadWhen downgrading we ensure that version we downgrade to is compatible.
-
- NyFixed property "ocpp" change bug.
- FörbättradProperties "powerweekday", "powerweekend" and "phase_map" can be changed through bluetooth.
- FörbättradChanged configuration handling to differentiate internally and externally set variables so that externally set or obtained variables are handled accordingly following the property schemas.
- ÅtgärdadWe now report wifi_static with static ip configuration.
- ÅtgärdadStatistics are now saved locally.
-
- FörbättradMeasurer fails are now registered with modbusrtumeasurer.
- FörbättradScreen font bigger for small title.
- ÅtgärdadValidate configuration with schemas during loading.
-
- NyOCPP authorize can now function by connector.
- NyOCPP WSS connection.
- NyFixed OCPP parent id tag bug.
- NyOCPP meter values now work for 3 phases.
- FörbättradFixed error 3 not appearing on screen.
- FörbättradFixed energy by hour bug.
- FörbättradChanged measurer reading approach for faster reads.
- FörbättradWith dynamic balancing we now show used and available power in frontend.
-
- FörbättradWe show dynamic balancing information on screen.
- FörbättradSimplified handling of configuration.
- FörbättradImproved dynamic balancing.
-
- FörbättradCharger won't reboot if car is in state B and OCPP or Payments is active.
- FörbättradWhen car changes from state C to B, charge information will persist on screen.
- FörbättradCurrent state charge now reports errors.
- FörbättradAdded configuration property validation.
- ÅtgärdadDirect method to obtain dynamic balancing information.
- ÅtgärdadGeneral dynamic balancing improvements.
- ÅtgärdadOCPP improvements.
-
- ÅtgärdadChanged remaining set_basic_unreported_config to set_basic_config.
-
- NyFix dynamic control bug, powerbytram is not being updated.
- NyFixed bug where whitelist of reported items wasn't being applied and properties weren't being stored in database.
- FörbättradRemoved non-repetitive logger.
- FörbättradChanged access point interface to change apn, with manual mode or mobile operator mode.
- UppdateradRefactored config charge box. Removed BASIC_UNREPORTED and created whitelist of properties to report.
- UppdateradPhase map is now not applied to installation meters.
- ÅtgärdadFixed payment bug where a charge couldn't be started properly if charge was started with the hose unlocked.
- ÅtgärdadFix bug with power being zero, dynamic control failing when there are no connectors.
- 3.1.8UppdateradForce WIFI and bluetooth GPIO pins for compute module 4 to work.
- 3.1.7UppdateradForce 4g GPIO pins for compute module 4 to work.
-
- FörbättradWhen we detect that measurers aren't working, we send an unblock command in case there's a charge and the charger has lost power.
- FörbättradCreate section BASIC_UNREPORTED for properties that are used but we don't want to report.
- FörbättradLocked value has persistance when measurers fail.
- ÅtgärdadWhen we don't receive petitions from chromium we now press enter and Ctrl+F5 if there's anything we need to accept.
-
- ÅtgärdadChanging WIFI configuration with bluetooth now reboots the charge point.
-
- FörbättradFixed configuration file so that software works with compute module 3 and 4.
- FörbättradChanged reboot logic. It will now reboot if there's a car connected but charge is not allowed.
- ÅtgärdadChanged payments qr code.
- ÅtgärdadWe can change log level with property.
-
- ÅtgärdadMeter values fixed. We now send wh instead of kwh.
-
- NyPause is now reset when it goes back to state A.
- NyShow measurer error as "Error 3" on connector. Behaviour is that connector is locked until it's fixed.
- NySet wire connected again.
- FörbättradFixed general network errors. Improved access point and wifi connectivity.
- ÅtgärdadFixed error where timezone wasn't set correctly so time appeared incorrectly.
- ÅtgärdadFixed payment_max_mode timeout bug.
-
- NyFixed power, it was shown in W and is now in Kw.
- FörbättradChange timezone automatically.
- ÅtgärdadAdded triphasic phoenix contact measurer.
- BorttagenFixed removal of grey notification update.
-
- NyWhenever there's an action that provokes rebooting, it will show on screen that it's going to reboot and the cause.
- NyScreen orientation can now be set and depending on parameter.
- NyAdded error message 1 and 2.
- NyBluetooth patch so that bluetooth initialization takes less time.
- NyCreated patch system. System level changes will be applied with this system.
- FörbättradMeasurer refactoring.
- FörbättradImei obtention improved.
- FörbättradInitial version of bluetooth finished: Obtain properties change basic properties, program charge, reboot, add rfid and change wifi.
- FörbättradBoot improvements. "Page not found" isn't shown anymore. Boot is faster. There's a gif indicating that system is starting.
- FörbättradObsolete properties are now deleted automatically so that they aren't reported.
- UppdateradRFID can now function with payments. If RFID is enabled with payments, registered cards will be able to start charges. If RFID is disabled with payments, no card will be able to start a charge.
- ÅtgärdadLimited number of messages we can send to iothub.
- ÅtgärdadIn OCPP, fixed sending of meter values. Now sending in wh and not in kwh.
- ÅtgärdadBoot patch so that GPIO pin initialization takes less time.
- ÅtgärdadMonophasic measurer Eastron SDM220 implemented.
- ÅtgärdadImproved robustness on all direct methods.
- ÅtgärdadFixed bug where it didn't reconnect properly to iothub when it disconnected.
- ÅtgärdadCreated direct method to put a QR code on the OCPP screen.
- BorttagenRemoved wire_connected event telemetry.
- 3.0.9ÅtgärdadFixed ocpp meter value Energy.Active.Import, when measurer is flipped.
-
- UppdateradFixed error where e-Charger couldn't obtain dns when connected with WIFI.
- ÅtgärdadFixed local load balancing when one connector was charging. Now when one connector is charging, it will charge at the set intensity.
- 3.0.7ÅtgärdadFixed ocpp Remote Start Transaction and Remote Stop Transaction.
- 3.0.6ÅtgärdadFixed error that ocurred in ocpp where it didn't clear properly the idtag when finishing a transaction.
-
- UppdateradChanged access point ip from 192.168.44.1 to 192.168.4.1
- UppdateradWe now report the charger's state instead of the requested vehicle state.
- UppdateradChanged access point master password.
- ÅtgärdadFixed websocket connection issue with nuitka compilation.
-
- FörbättradImproved update logs.
- 3.0.3NyMoved Version from center to right side and added V. before the version number.
- 3.0.2FörbättradSTM will now detect SPI bus communication errors and will automatically reset.
-
- NyScreen now shows when RFID card is registered.
- NyTop bar now shows version and if access point is accessible.
- NyAccess point interface now has, local load balancing, rfid card registering and log download.
- NyCheck that compute module and board have been created properly.
- FörbättradScreen is now monitored so that it refreshes in the case that no requests have been made after 15 seconds.
- FörbättradQA diagnostic is obtained through access point.
- FörbättradReduced access point available time to 10 minutes.
- ÅtgärdadFixed bug where connector stopped working properly when sending intensity 0.
-
- NyInitial Version