Pole Pro atnaujinimai
Nuolat dirbame, kad patobulintume Pole Pro funkcijas. Čia rasite naujausią mūsų e-Charger versiją ir paskutinius atliktus atnaujinimus.
Naujausia versija
6.1.3
Pole Pro
Turite ankstesnį Pole? Peržiūrėkite jo atnaujinimus.
6.1.3Naujausia versija
- PataisymasThe charger no longer hangs when rebooting while shutting down the 4G module or dynamic power control
Ankstesnės versijos 46
- 6.1.2PataisymasOCPP security event notifications are no longer sent when the connection uses no security profile (profile 0), since some central systems do not support them
-
- PataisymasCorrected default APN for Wireless Logic SIM cards in Belgium
-
- NaujienaAudible buzzer feedback
- NaujienaSupport for registering multiple RFID cards
- NaujienaReading of the installation meter over Modbus RS485 on DC chargers
- NaujienaDynamic power control for DC installations — master and slave units now share and honor the installation power limit
- NaujienaLive display of actual consumption versus offered current on the charger screen
- NaujienaOn-screen guidance walks the user through registering an RFID card
- NaujienaOCPP connection password can now be set from the Cloud and Bluetooth
- NaujienaOCPP now supports security profiles, encrypted TLS connections and Basic Authentication for the central system
- PatobulinimasLanguage codes standardized to the ISO 639-1 format
- PatobulinimasReduced volume of messages sent to the Cloud
- PatobulinimasTime synchronization with the CSMS no longer floods the system log
- PatobulinimasLog rotation no longer loses history when the disk is full
- PatobulinimasSafer firmware updates
- PatobulinimasMore reliable connectivity with automatic failover between Ethernet and 4G
- PatobulinimasCharges history now loads page by page instead of the whole history at once, for a faster tab
- PataisymasMeasurer error message now reads clearly
- PataisymasMore accurate meter-reading validation
- PataisymasCharge metrics are preserved if a charge is interrupted unexpectedly
- PataisymasScreen orientation set in configuration is now applied correctly
- PataisymasFree-charge mode could not be disabled from the installer panel
- PataisymasDynamic power limit was not applied at tariff/hour boundaries, briefly leaving an installation without a limit
- PataisymasResolved random service restarts (crashes) caused by network device discovery
-
- PatobulinimasMore reliable RFID card reading with optimized antenna configuration from first use
- PatobulinimasImproved stability and responsiveness of the charger's web interface
-
- NaujienaOCPP - Immediate "Preparing" status when receiving a remote start command via OCPP
- NaujienaWiFi disabled by default on devices without WiFi configured
- PatobulinimasMore reliable RFID card reading with periodic reader reinitialization
- PatobulinimasBetter cable connection detection and RFID timeout handling
- PatobulinimasCDP - More stable network device discovery, preventing unnecessary register/unregister cycles
- PatobulinimasImproved stability when applying configuration changes to the charger
- PatobulinimasAutomatic migration of legacy pending OCPP messages after update
- PatobulinimasImproved network handling when switching between manual and automatic IP configuration
- PataisymasPower factor value conversion for Carlo Gavazzi meters
- PataisymasImprovements in power measurement accuracy in single-phase or two-phase installations
- PataisymasOCPP - Smart Charging profiles with defined duration now applied correctly
- PataisymasOCPP - Local authentication cache overflow that could prevent charging sessions from startIing
- PataisymasOCPP - OCPP transactions stuck due to unreleased semaphores or null keys
-
- NaujienaEnhanced web server for accessing and editing charger properties
- NaujienaVisual improvements to the web server interface
- NaujienaPersistent price display on screen when the payment system is active
- NaujienaRefined error reporting to the cloud
- NaujienaPower loss detection
- NaujienaWi-Fi disable option from the installer panel
- NaujienaNew buzzer system implementation for white boards
- PatobulinimasEnhanced RFID calibration with on-screen indicator during the process
- PatobulinimasRFID reader no longer forcibly activates when OCPP or Payments are active; explicit configuration is respected
- PatobulinimasRefined cable connect/disconnect notification on each event when payments are active
- PatobulinimasOptimized RFID card readings
- PatobulinimasOCPP - Improvements to the offline transaction queue
- PatobulinimasInternal connection optimization and overall performance improvements
- PataisymasOCPP - Improved measurement value reporting
- PataisymasRefined out-of-range measurement error detection
-
- NaujienaSoftware-level leak detection enable/disable
- PatobulinimasAdjusted cooldown time between charges when a leak is detected
- PatobulinimasOCPP - Improvements to the offline transaction queue
-
- PatobulinimasWhen OCPP is active, we now show on screen when card passed is not registered in central system.
- PataisymasAfter update OCPP image and QR is now recovered.
-
- PataisymasFixed issue where it didn't allow a remote start if a car is connected but not in an active transaction.
- PataisymasFixed issue in setup interface.
- PataisymasFixed monophasic Carlo Gavazzi measurer.
- PataisymasFixed OCPP issue where it wouldn't charge in connector 2 if connector 1 is charging.
-
- PatobulinimasImproved network features mainly 4G connection.
-
- PatobulinimasImproved OCPP charge handling.
- PatobulinimasEnhanced reliability in the smart charging logic.
- PatobulinimasImproved features when stopping a charge with invalid identifiers.
- PatobulinimasImproved QR configuration for OCPP.
- PatobulinimasImproved error handling when sensors or communication components fail.
- PatobulinimasBetter log management to prevent the device’s storage from filling up.
- PatobulinimasImproved USB connection features.
- PatobulinimasImproved RFID calibration and detection display.
- PatobulinimasImproved features related to Bluetooth.
- PatobulinimasImproved dynamic power control allowing charge at minimum intensity if master is not detected.
-
- NaujienaManual timezone setting is now available – The user will be able to configure the timezone even if automatic detection is disabled
- NaujienaCreated a contingency page in case app is not running
- NaujienaAdded Italian option for screen
- NaujienaAdded default payment QR to pay without app
- NaujienaAdded new OCPP personalization options - The user can now set 2 QR codes on the screen
- PatobulinimasImproved updater
- PatobulinimasImproved network connections
- PatobulinimasImproved OCPP meter values
- PatobulinimasImproved discovering devices when dynamic control is active
- PatobulinimasImproved user interface when updates are in progress
- PatobulinimasLocal load balancing is now implemented as dynamic control based specific conditions
- PatobulinimasImproved Bluetooth connection
- PatobulinimasImproved 4g connections robustness
- PatobulinimasImproved STM32 lock timings
- PatobulinimasImproved OCPP now allows external intensity limits
- PatobulinimasImproved data consumption
- PataisymasWhen locking a connector while charging, it now sends end charge telemetry correctly
- PataisymasFixed dynamic control issues
- PataisymasFixed Carlo Gavazzi power meter
- PataisymasFixed OCPP LMS, diagnostics, and charging profile clearing
-
- NaujienaAdded shared library
- NaujienaTimezone can be set manually
- NaujienaTime is now synced with Central System if OCPP is active
- PatobulinimasImproved version/update manager
- PatobulinimasImproved megabyte conversion of Network Monitor
- PatobulinimasObtaining timezone now doesn't need to have correct time by using only http urls
- PatobulinimasMobile usb device name is now obtained dynamically since more usb ports might be used due to TPV
- PataisymasFixed power control issues
- PataisymasFixed that when locking connector during a charge it now ends correctly
- PataisymasRecalculate reboot time when changing time with ble
- PataisymasWe now show on screen when non registered RFID is passed while OCPP is active
- PataisymasFixed OCPP freemode rfid issues
- PataisymasDuplicate StatusNotifications are removed from offline queue
- PataisymasFixed "infinite" OCPP offline queue issue
-
- NaujienaAPN can now be set manually
- PatobulinimasWe now show on screen different wifi images depending on how strong signal is to let know the user how good the connection is
- PatobulinimasGeneral OCPP improvements: we check connection to CS instead of internet for local functioning, we notify a real value now when there's a stop transaction due to power loss, fixed edge cases where connectivity is lost, new ocpp key MaxEVCurrentOffered implemented which limits charge with key instead of smart charging handler, safety mechanisms for ocpp to be more robust
- PatobulinimasIn 4g, increased rssi range for "excellent" so that it indicates correctly when the reception is good
- PatobulinimasImproved data consumption
- PatobulinimasImproved robustness of update
- AtnaujintaAccess point time increased to 15 minutes
- PataisymasHandled issues when SSID has whitespace
-
- PataisymasAccess point improvements.
- PataisymasFixed QA issues.
-
- NaujienaNew direct method to obtain additional information for Smart Charging.
- NaujienaFixed random reboot time.
- PatobulinimasFixed unset RFID.
- PatobulinimasFixed Unknown measurer and made distinction between Unknown measurer and wrongly configured measurer.
- PatobulinimasOCPP Free mode can be toggled through OCPP keys.
- AtnaujintaFixed BLE connection with iphone and fixed bluetooth communication error that appeared on app.
- AtnaujintaNetwork improvements. No interface resets performed at boot which improves bootup time. Network changes now don't require reboot. When changing WIFI settings or ip ethernet settings, it connects after setting it instead of rebooting.
- PataisymasFixed issue where things on screen were missing in one connector chargers.
- PataisymasFixed time/timezone issue caused when the date is off by a few days.
- PataisymasNew property added to toggle if vehicle should be able to charge even though measurers aren't working ( Only works when OCPP, payments or dynamic control isn't enabled ).
-
- NaujienaReflect on screen when charge is paused.
- NaujienaMade reboot time random.
- PataisymasIncreased SAS token time to live of azure.
-
- NaujienaChanges made to reduce network usage that can be toggled on or off.
- NaujienaFixed case where config is corrupted or missing and would give trouble at startup.
- NaujienaWe now send dead letter if cpu gets too hot and cpu temperature is now logged.
- PatobulinimasFixed OCPP inverted measurer error.
- PatobulinimasAdded mechanism to disable or enable Wifi and bluetooth.
- PatobulinimasWe now report information regarding which type of connection to the internet the e-charger has.
- AtnaujintaChanged led colors. Switched State A (now white) and State B (now green) colors.
- PataisymasFixed set threshold values and neopixel leds of Stm32. We can now also obtain control pilot value from Stm32.
- PataisymasOCPP ConnectionTimeOut value can now be changed on the fly.
- PataisymasWe now report iccid of sim card is connected. If sim is connected but we can't obtain iccid, we send dead letter.
- PataisymasFixed log download of http interface.
-
- NaujienaLTE signal is now reflected correctly instead of always showing great signal.
- PatobulinimasFixed wathdog reboot after doing hard reset.
-
- NaujienaAdded dynamic photovoltaic.
- NaujienaAdded dead letters: measurer fails and kernel error.
- NaujienaProperty "wifi_info" is now reported.
- NaujienaProperty "wifi_static" can be set through ble.
- NaujienaWe can now obtain statistics through direct method.
- NaujienaAdded individual log level for each type of logger.
- NaujienaAdded neopixel led type for stm32.
- NaujienaWe can now set threshold values with stm32 and get control pilot value if debug log of "Stm32" is activated.
- PatobulinimasImprovements in dynamic control, fabrication, QA, Azure, OCPP, config handling, 4g, access point and stm32.
- PatobulinimasWe now obtain timezone through url.
- PatobulinimasRemoved raspbian logo and desktop during boot and added V2C logo.
- PatobulinimasChanged default language after fabrication from english to spanish.
- AtnaujintaGeneral bug fixes.
- PataisymasWhen downgrading we ensure that version we downgrade to is compatible.
-
- NaujienaFixed property "ocpp" change bug.
- PatobulinimasProperties "powerweekday", "powerweekend" and "phase_map" can be changed through bluetooth.
- PatobulinimasChanged configuration handling to differentiate internally and externally set variables so that externally set or obtained variables are handled accordingly following the property schemas.
- PataisymasWe now report wifi_static with static ip configuration.
- PataisymasStatistics are now saved locally.
-
- PatobulinimasMeasurer fails are now registered with modbusrtumeasurer.
- PatobulinimasScreen font bigger for small title.
- PataisymasValidate configuration with schemas during loading.
-
- NaujienaOCPP authorize can now function by connector.
- NaujienaOCPP WSS connection.
- NaujienaFixed OCPP parent id tag bug.
- NaujienaOCPP meter values now work for 3 phases.
- PatobulinimasFixed error 3 not appearing on screen.
- PatobulinimasFixed energy by hour bug.
- PatobulinimasChanged measurer reading approach for faster reads.
- PatobulinimasWith dynamic balancing we now show used and available power in frontend.
-
- PatobulinimasWe show dynamic balancing information on screen.
- PatobulinimasSimplified handling of configuration.
- PatobulinimasImproved dynamic balancing.
-
- PatobulinimasCharger won't reboot if car is in state B and OCPP or Payments is active.
- PatobulinimasWhen car changes from state C to B, charge information will persist on screen.
- PatobulinimasCurrent state charge now reports errors.
- PatobulinimasAdded configuration property validation.
- PataisymasDirect method to obtain dynamic balancing information.
- PataisymasGeneral dynamic balancing improvements.
- PataisymasOCPP improvements.
-
- PataisymasChanged remaining set_basic_unreported_config to set_basic_config.
-
- NaujienaFix dynamic control bug, powerbytram is not being updated.
- NaujienaFixed bug where whitelist of reported items wasn't being applied and properties weren't being stored in database.
- PatobulinimasRemoved non-repetitive logger.
- PatobulinimasChanged access point interface to change apn, with manual mode or mobile operator mode.
- AtnaujintaRefactored config charge box. Removed BASIC_UNREPORTED and created whitelist of properties to report.
- AtnaujintaPhase map is now not applied to installation meters.
- PataisymasFixed payment bug where a charge couldn't be started properly if charge was started with the hose unlocked.
- PataisymasFix bug with power being zero, dynamic control failing when there are no connectors.
- 3.1.8AtnaujintaForce WIFI and bluetooth GPIO pins for compute module 4 to work.
- 3.1.7AtnaujintaForce 4g GPIO pins for compute module 4 to work.
-
- PatobulinimasWhen we detect that measurers aren't working, we send an unblock command in case there's a charge and the charger has lost power.
- PatobulinimasCreate section BASIC_UNREPORTED for properties that are used but we don't want to report.
- PatobulinimasLocked value has persistance when measurers fail.
- PataisymasWhen we don't receive petitions from chromium we now press enter and Ctrl+F5 if there's anything we need to accept.
-
- PataisymasChanging WIFI configuration with bluetooth now reboots the charge point.
-
- PatobulinimasFixed configuration file so that software works with compute module 3 and 4.
- PatobulinimasChanged reboot logic. It will now reboot if there's a car connected but charge is not allowed.
- PataisymasChanged payments qr code.
- PataisymasWe can change log level with property.
-
- PataisymasMeter values fixed. We now send wh instead of kwh.
-
- NaujienaPause is now reset when it goes back to state A.
- NaujienaShow measurer error as "Error 3" on connector. Behaviour is that connector is locked until it's fixed.
- NaujienaSet wire connected again.
- PatobulinimasFixed general network errors. Improved access point and wifi connectivity.
- PataisymasFixed error where timezone wasn't set correctly so time appeared incorrectly.
- PataisymasFixed payment_max_mode timeout bug.
-
- NaujienaFixed power, it was shown in W and is now in Kw.
- PatobulinimasChange timezone automatically.
- PataisymasAdded triphasic phoenix contact measurer.
- PašalintaFixed removal of grey notification update.
-
- NaujienaWhenever there's an action that provokes rebooting, it will show on screen that it's going to reboot and the cause.
- NaujienaScreen orientation can now be set and depending on parameter.
- NaujienaAdded error message 1 and 2.
- NaujienaBluetooth patch so that bluetooth initialization takes less time.
- NaujienaCreated patch system. System level changes will be applied with this system.
- PatobulinimasMeasurer refactoring.
- PatobulinimasImei obtention improved.
- PatobulinimasInitial version of bluetooth finished: Obtain properties change basic properties, program charge, reboot, add rfid and change wifi.
- PatobulinimasBoot improvements. "Page not found" isn't shown anymore. Boot is faster. There's a gif indicating that system is starting.
- PatobulinimasObsolete properties are now deleted automatically so that they aren't reported.
- AtnaujintaRFID can now function with payments. If RFID is enabled with payments, registered cards will be able to start charges. If RFID is disabled with payments, no card will be able to start a charge.
- PataisymasLimited number of messages we can send to iothub.
- PataisymasIn OCPP, fixed sending of meter values. Now sending in wh and not in kwh.
- PataisymasBoot patch so that GPIO pin initialization takes less time.
- PataisymasMonophasic measurer Eastron SDM220 implemented.
- PataisymasImproved robustness on all direct methods.
- PataisymasFixed bug where it didn't reconnect properly to iothub when it disconnected.
- PataisymasCreated direct method to put a QR code on the OCPP screen.
- PašalintaRemoved wire_connected event telemetry.
- 3.0.9PataisymasFixed ocpp meter value Energy.Active.Import, when measurer is flipped.
-
- AtnaujintaFixed error where e-Charger couldn't obtain dns when connected with WIFI.
- PataisymasFixed local load balancing when one connector was charging. Now when one connector is charging, it will charge at the set intensity.
- 3.0.7PataisymasFixed ocpp Remote Start Transaction and Remote Stop Transaction.
- 3.0.6PataisymasFixed error that ocurred in ocpp where it didn't clear properly the idtag when finishing a transaction.
-
- AtnaujintaChanged access point ip from 192.168.44.1 to 192.168.4.1
- AtnaujintaWe now report the charger's state instead of the requested vehicle state.
- AtnaujintaChanged access point master password.
- PataisymasFixed websocket connection issue with nuitka compilation.
-
- PatobulinimasImproved update logs.
- 3.0.3NaujienaMoved Version from center to right side and added V. before the version number.
- 3.0.2PatobulinimasSTM will now detect SPI bus communication errors and will automatically reset.
-
- NaujienaScreen now shows when RFID card is registered.
- NaujienaTop bar now shows version and if access point is accessible.
- NaujienaAccess point interface now has, local load balancing, rfid card registering and log download.
- NaujienaCheck that compute module and board have been created properly.
- PatobulinimasScreen is now monitored so that it refreshes in the case that no requests have been made after 15 seconds.
- PatobulinimasQA diagnostic is obtained through access point.
- PatobulinimasReduced access point available time to 10 minutes.
- PataisymasFixed bug where connector stopped working properly when sending intensity 0.
-
- NaujienaInitial Version
6 iš 46