Screen güncellemeleri
Screen'in işlevlerini geliştirmek için sürekli çalışıyoruz. Burada e-Charger'ımızın en son sürümünü ve yapılan son güncellemeleri bulabilirsiniz.
En son sürüm
2.20
Screen
2.20En son sürüm
- DüzeltmeFixed rfid bug in ocpp.
Önceki sürümler 65
- 2.19DüzeltmeFixed rfid card issue in stop transactions.
- 2.18DüzeltmeFixed OCPP error where transaction wasn't started when states passed from C to B to C.
- 2.17DüzeltmeCB Master: Improved robustness of rfid charge track so that if one connector is fully charged and a different car wants to charge in the other connector it can now charge.
- 2.16DüzeltmeCB Master: Fixed bug that wouldn't allow two connectors to charge with payment + RFID.
- 2.15YeniCB Master/CB N: Rfid cards can start a charge in payment mode if rfid is enabled.
- 2.14DüzeltmeCB Master: We check if measurer is flipped by connector instead of globally.
- 2.13DüzeltmeCB Master: We check if measurer is flipped while configuring meter values so that they are sent correctly.
-
- DüzeltmeCB N: Fixed cloud iot problem.
- DüzeltmeCB Master: Configuration file is restored correctly in the case it's lost. This provoked the page not found error.
- DüzeltmeCB Master: Fixed bug where a connector couldn't start a charge when there's a car on the other connector with state B.
- 2.11DüzeltmeCB Master: Meter power bug fix.
-
- YeniCB N: Car state management D and E.
- İyileştirmeCB N: General payment improvements.
- İyileştirmeCB N: In payment method, when you move from status c to b, it does not allow you to reload again until you start a new transaction.
- İyileştirmeCB N: Improved restart logic when any OCPP configuration is changed.
- İyileştirmeCB Master: General meter improvements.
- İyileştirmePole: Filter to reduce number of logs.
- DüzeltmeCB Master: Fixed payment bug that sent the upload permission to the wrong connector.
- DüzeltmeCB Master: Fixed bug that when two cars were connected and the B connector was in B status, when the card was swiped, the B was set to charge when the A should be set.
- DüzeltmeCB Master: Total energy bug arrangement from version using imported and exported energy.
-
- İyileştirmeCB Master: Meter restructuring.
- İyileştirmeOCPP: General improvements in Smart Charging and Tx Profile implemented.
- İyileştirmeOCPP: Changes due to restructuring of the meter.
- İyileştirmeOCPP: Restructuring of smart charging. Obtain composite timetable with several profiles.
-
- YeniCB Master: Integrated SACI meter and changes so that the serial configuration per connector is not linked.
- İyileştirmeCB Master: Increased RFID SPI communication speed and lowered RFID gain if noise is detected.
- İyileştirmeCB Master: Code refactoring
-
- YeniOCPP: Starting point for get composite schedule done.
- YeniOCPP: Relative profiles are handled but only for Smart Charge profiles where connector id is bigger than 0.
- YeniOCPP: Smart Charging Tx Profiles are now accepted.
- YeniOCPP: In websocket connection, added "compression=None" since without it it doesn't work on latest Steve version.
- İyileştirmeCB Master: Refactored serial and made some changes that improve flexibility. We can now have one connector with one type of measurer and the other connector with a different type of measurer.
- İyileştirmeOCPP: Added next time check mechanism for Smart Charging so we check the next time any limit changes instead of every 30 seconds.
- İyileştirmeOCPP: General Smart Charge improvements.
- DüzeltmeCB Master: Convert to positive the negative values read by Phoenix Contact measurer.
- DüzeltmeCB Master: Adjusted the precision of Phoenix Contact monophasic measurers.
- DüzeltmeCB N: Fixed bug provoked by changing local load balancing from v2c service.
- DüzeltmeOCPP: Change availability of Persistant Data handler is now async so that we can call it without blocking the execution of the ServerController.
- DüzeltmeOCPP: Fixed clear charging profiles.
- DüzeltmeOCPP: We handle decimal numbers on the Smart Charge profile's limit.
-
- YeniCB N: Changes due to Smart Charging
- YeniOCPP: Smart Charging starting point fininshed.
- YeniOCPP: Smart Charging configuration keys are handled.
- YeniOCPP: Smart Charging profiles can be added and will be validated and can also be deleted.
- DüzeltmeOCPP, CB N and CB Master: Fixed bug when locked was modified and ocpp was activated but chargepoint isn't connected to any central system.
- DüzeltmeCB Master: Fixed bug when OCPP charge is started where if connector 1 was charging, connector 0 couldn't start a charge.
- DüzeltmeCB Master: Prevent crash in the case that .versions folder doesn't exist.
- DüzeltmeCB Master: Register cards are now added to card cache.
-
- YeniPole: Screen now shows when user passes a non registered RFID card.
- İyileştirmeCB Master: Improvements in update process.
- İyileştirmeCB Master: Changes so that screen indicates when a non registered RFID card is passed.
- İyileştirmeCB N: Improvements in update process.
- İyileştirmeOCPP: GetConfigurationKeys now returns unknown keys and we handle SupportedFileTransferProtocols key.
- İyileştirmePole: Romanian identifier moved to position 6 to maintain order language with Trydan.
-
- İyileştirmeCB Master: We store RFID cards in cache.
- İyileştirmeCB N: RFID reader improvements. Case where two connectors are plugged in and a card is passed.
- İyileştirmeCB N: New communication method so that CB master can obtain RFID cards.
- KaldırıldıCB Master: We don't send wifi_info in report anymore and we have removed functions related to wifi_info.
- KaldırıldıCB N: We don't send wifi_info in report anymore.
-
- YeniCB N: Static IP configuration through access point.
- İyileştirmeCB Master: Improvement in connect/disconnect logic. Disconnection is less rigid and we increased network check from 5 seconds to 15 seconds.
- İyileştirmeCB Master: Increased RFID reader antenna gain.
- İyileştirmeCB N: When charger reconnects, it will only send report if a property has changed.
- İyileştirmeCB N: Properties are now only reported when they have changed from previous value.
- DüzeltmeCB Master: CWe fix error provoked by blocking/unblocking when charger has OCPP activated and isn't connected to central system.
- DüzeltmeCB N: We fix error provoked by blocking/unblocking when charger has OCPP activated and isn't connected to central system.
- DüzeltmeOCPP: We fix error provoked by blocking/unblocking when charger has OCPP activated and isn't connected to central system.
-
- İyileştirmeCB Master: Safeguard so that it doesn't fail when there's a missing network card and we try to obtain data usage.
- İyileştirmeOCPP: Removed range validation from measurer.
- GüncellendiCB Master: Removed range validation from measurer for Carlo Gavazzi and Phoenix Contact measurers.
- DüzeltmeCB Master: Fixed energy by hour bug.
-
- İyileştirmeCB N: We show in log if i2c reconnects.
-
- YeniCB Master: Chargebox Cache now stores state of connectivity with V2C service to show it on the screen.
- YeniCB N: Chargebox Cache now stores state of connectivity with V2C service.
- YeniPole: The screen now shows a cloud icon to indicate connectivity to our cloud.
- İyileştirmeCB Master: Adjustment in measurer so that it can handle int32 represented as uint.
- İyileştirmeCB N: Log improvements to not show get_has_internet_connection y and reduce error messages generated when i2c is not working.
- İyileştirmeCB N: Changes to reduce calls to has_internet_connection to consume less data.
- İyileştirmeOCPP: We log exception names since sometimes exception errors return empty string.
- İyileştirmeOCPP: We capture error if there's an error when sending heartbeat.
- İyileştirmeOCPP: We change client controller so that it's the same as CB N and CB Master.
- DüzeltmeCB N: Seconds of timeout now return 0 instead of None if not set.
-
- İyileştirmeCB Master: Master now sends the balanced intensity when it changes.
- İyileştirmeCB N: Changed order of what happens when configuration is changed. We first update the value, then we report the changes to Azure and finally we set the cache.
- İyileştirmeCB N: CB Master now sends balanced intensity instead of CB N probing for change.
- DüzeltmeCB Master: Fixed error where RFID stops charge while the other connector is enabled.
- DüzeltmeCB Master: Fixed error where RFID card is passed and both connectors have a car plugged in.
- DüzeltmeCB N: Fixed bug where changing local load balancing set both connector intensities to 16.
-
- İyileştirmeCB Master: Change in log system to not show repeated logs.
- İyileştirmeCB Master: Shared properties are now set in the other connector if they are different on startup.
- İyileştirmeCB Master: Completely decoupled OCPP from CB N and get_ocpp_config function fixed.
- İyileştirmeCB Master: Network state is now sent when changed instead of being probed every 30 seconds.
- İyileştirmeCB N: General improvements of communication between modules and cache.
- İyileştirmeCB N: Improved stability related with missing configuration.
- İyileştirmeCB N: Change in log system to not show repeated logs.
- İyileştirmeCB N: Fixed problem where Chargebox loop would destroy RFID state.
- İyileştirmeCB N: Fixed OCPP ConnectionTimeout.
- İyileştirmeCB N: Completely decoupled OCPP from CB N
- İyileştirmeCB N: Network state is now sent when changed instead of being probed every 30 seconds.
- İyileştirmeCB N: We only change repository hash if it's different than the current one.
- İyileştirmeCB N: Updating checks if charger is updated or not and only changes version after it has been updated.
- İyileştirmeCB N: General improvements of communication between modules.
- İyileştirmeOCPP: Improved Client Controller traceability.
-
- İyileştirmeCB Master: Created Cache to decrease the number of requests and communication between modules.
- İyileştirmeCB Master: Fixed network reset problem.
- İyileştirmeCB Master: Changes so that Pole can receive all the information it needs in one call.
- İyileştirmeCB Master: Changes dues to how the measures are now sent.
- İyileştirmeCB Master: General access point improvements.
- İyileştirmeCB Master: Improvements due to changes in module communication.
- İyileştirmeCB N: Created singletons are now thread safe.
- İyileştirmeCB N: Server Controller is now executed sooner due to being fundamental in correct functioning.
- İyileştirmeCB N: Changes to take into account CB Master's cache
- İyileştirmeCB N: Changed way we obtain measures to perform less requests with Client Controller.
- İyileştirmeCB N: Improvements due to changes in module communication.
- İyileştirmeOCPP: Created singletons are now thread safe.
- İyileştirmeOCPP: Completely decoupled from CB N and now only communicates with CB Master.
- İyileştirmeOCPP: Simplified communication between modules.
- İyileştirmeOCPP: Improvements due to changes in module communication.
- İyileştirmePole: Created singletons are now thread safe.
- İyileştirmePole: Completely decoupled CB N and we obtain all information needed in one call to CB Master.
- İyileştirmePole: Improvements due to changes in module communication.
-
- İyileştirmeCB Master: The charger now limits the number of messages that appear in the case that there's a range validation fail of a measure.
- İyileştirmeCB N: Client Controller won't stop sending messages and will show errors every 10 wrongly sent messages.
- İyileştirmeCB N: Restart Server Controller mechanism.
- İyileştirmeOCPP: Client Controller won't stop sending messages and will show errors every 10 wrongly sent messages.
- İyileştirmeOCPP: Restart async Server Controller mechanism.
- İyileştirmePole: Client Controller won't stop sending messages and will show errors every 10 wrongly sent messages.
- DüzeltmeOCPP: If there's an error handling a request, we won't add it to the offline queue.
- DüzeltmeOCPP: Include thread and sys libraries.
-
- İyileştirmeCB N: When rebooting, we check module communication server.
- İyileştirmeCB N: Decoupled concept of connector id and measurer address.
- İyileştirmeCB Master: When rebooting, we check module communication server.
- İyileştirmeCB Master: Decoupled concept of connector id and measurer address.
- İyileştirmeCB Master: Fixed error in Phoenix Contact measurer.
- İyileştirmePole: ZMQ integrated to improve communication.
-
- İyileştirmePole: Improvement to let the user know when to connect the vehicle.
- İyileştirmePole: Screen now reflects if charger has only one connector.
- İyileştirmeCB Master: Changed SSID format so that it's the same as Trydan's format.
-
- İyileştirmeOCPP: Added measurer range validation.
- İyileştirmeCB Master: Added measurer range validation.
- GüncellendiOCPP: AuthorizeRemoteTxRequests is now a read and write configuration key.
- DüzeltmeOCPP: Fixed problem with repeated logs.
- DüzeltmeCB Master: Fixed problem with repeated logs.
- DüzeltmeCB N: Fixed problem with repeated logs.
-
- İyileştirmeCB N: Handled special case of change intensity.
-
- YeniCB Master: Access point logic fininshed.
- YeniOCPP: Data validation when configuration is changed.
- YeniOCPP: Charger can now handle multiple transactions offline.
- İyileştirmeCB N: If OCPP is on, we disable payment mode.
-
- İyileştirmeOCPP: Reset function improved. Corresponding Status Notification is sent.
-
- İyileştirmeCB N: General stability improvements.
- İyileştirmeCB N: Changed payment method approach.
- İyileştirmeCB Master: Changed payment method approach.
- İyileştirmeCB Master: Improved robustness in the case the access point software is not installed.
- İyileştirmePole: Improvements due to payment method.
-
- YeniOCPP: Change availability validates connector.
- YeniCB Master: Finished Access point.
- İyileştirmeCB Master: Changed compressed file formats from gzip to gz
- İyileştirmeCB Master: Force backup when restarting.
-
- YeniCB N: Allow to change intensity, when i2c is failing.
- YeniCB Master: Implemented most of the access point server functionalities.
- DüzeltmeCB Master: Fixed OCPP measurer error that ocurred when all selected measures in Meter Values returned 0.
- 1.4.3YeniCB Master: Initial version of the access point server.
-
- İyileştirmeCB N: Changes to improve Pole software.
- İyileştirmePole: Changes to simplify view logic.
- DüzeltmeCB Master: If payment mode is active, charger won't allow to charge with RFID card.
- DüzeltmePole: Removed sourceMappingUrl to prevent 404 error when there's no internet.
- 1.4.1DüzeltmeCB N: Payment mode changed since payload format for server has changed.
- 1.4.0YeniPole: Changes in screen software that reflects payment mode, blocking connectors and OCPP.
-
- DüzeltmeOCPP: Charger won't send Authorize if passed RFID card is already used in a transaction.
- 1.3.23İyileştirmeOCPP: We store RFID cards in lower caps to improve robustness.
-
- İyileştirmeOCPP: Improved robustness of RFID cards stored in the Local Authorization list.
-
- İyileştirmeOCPP: Improved Local Authorization logic.
-
- DüzeltmeCB Master: Fixed wifilist sending format.
-
- YeniCB N: We report information regarding wifi_info. Direct method to ask for the SSIDs the raspberry pi detects.
- 1.3.18İyileştirmeOCPP: Improved authorization cache handler.
-
- İyileştirmeOCPP: Improved handling of measurer values.
-
- İyileştirmeOCPP: Improved handling of configuration keys.
-
- GüncellendiCB N: Payment mode with duration and timers.
-
- İyileştirmeOCPP: Improved MeterValues handler.
- 1.3.13YeniOCPP: Finished Local Authorization List profile.
- 1.3.12İyileştirmeOCPP: Log Improvements.
- 1.3.11DüzeltmeOCPP: Fixed bug that wouldn't send Authorize Request when passing the RFID card.
-
- YeniOCPP: Basic implementation of OCPP profiles: FirmwareManagement, LocalAuthListManagement, Reservation and SmartCharging.
- 1.3.9İyileştirmeCB Master: Fixed RFID card reading with Wiegand reader for cards that have a 0 on the left side. Example of cards that failed: 32:0a:2c:23, 41:00:32:12.
-
- GüncellendiOCPP: Availability isn't managed by OCPP anymore. It is handled exclusively by property locked.
- 1.3.7İyileştirmeCB N: If charger is blocked, led blinks won't be sent.
- 1.3.6YeniCB N: Payment Mode finished with start and stop.
- 1.3.5İyileştirmeOCPP: Clear Cache can only be performed when all connectors are in the OCPP state Available.
-
- İyileştirmeOCPP: Changes so that availability can be changed from CB N.
-
- İyileştirmeCB Master: OCPP module can now ask for Status Notification.
- GüncellendiOCPP: The charger the different possible OCPP states in the Status Notification.
- 1.3.2İyileştirmeOCPP: We can now set configuration parameters for safeguard.
- 1.3.1İyileştirmeOCPP: Change availability is now completely functional. It changes to inoperative during a charge and availability changes the locked value.
- 1.3.0DüzeltmeOCPP: Changed way we obtain measurer data for OCPP.
- 1.2.0DüzeltmeOCPP: Temporary fix for Place to plug since OCPP library can't handle unknown keys.
- 1.1.0DüzeltmeOCPP: Fixed _available_connectors error.
-
- YeniOCPP.
- YeniScreen.
- YeniPole.
- YeniCB Master.
- YeniCB N.
6 / 65