تحديثات Pole Pro
نعمل باستمرار على تحسين ميزات Pole Pro. هنا ستجد أحدث إصدار من شاحننا الإلكتروني e-Charger وآخر التحديثات التي تم تنفيذها.
أحدث إصدار
6.1.3
Pole Pro
هل لديك Pole السابق؟ اطّلع على تحديثاته.
6.1.3أحدث إصدار
- إصلاحThe charger no longer hangs when rebooting while shutting down the 4G module or dynamic power control
الإصدارات السابقة 46
- 6.1.2إصلاحOCPP security event notifications are no longer sent when the connection uses no security profile (profile 0), since some central systems do not support them
-
- إصلاحCorrected default APN for Wireless Logic SIM cards in Belgium
-
- جديدAudible buzzer feedback
- جديدSupport for registering multiple RFID cards
- جديدReading of the installation meter over Modbus RS485 on DC chargers
- جديدDynamic power control for DC installations — master and slave units now share and honor the installation power limit
- جديدLive display of actual consumption versus offered current on the charger screen
- جديدOn-screen guidance walks the user through registering an RFID card
- جديدOCPP connection password can now be set from the Cloud and Bluetooth
- جديدOCPP now supports security profiles, encrypted TLS connections and Basic Authentication for the central system
- تحسينLanguage codes standardized to the ISO 639-1 format
- تحسينReduced volume of messages sent to the Cloud
- تحسينTime synchronization with the CSMS no longer floods the system log
- تحسينLog rotation no longer loses history when the disk is full
- تحسينSafer firmware updates
- تحسينMore reliable connectivity with automatic failover between Ethernet and 4G
- تحسينCharges history now loads page by page instead of the whole history at once, for a faster tab
- إصلاحMeasurer error message now reads clearly
- إصلاحMore accurate meter-reading validation
- إصلاحCharge metrics are preserved if a charge is interrupted unexpectedly
- إصلاحScreen orientation set in configuration is now applied correctly
- إصلاحFree-charge mode could not be disabled from the installer panel
- إصلاحDynamic power limit was not applied at tariff/hour boundaries, briefly leaving an installation without a limit
- إصلاحResolved random service restarts (crashes) caused by network device discovery
-
- تحسينMore reliable RFID card reading with optimized antenna configuration from first use
- تحسينImproved stability and responsiveness of the charger's web interface
-
- جديدOCPP - Immediate "Preparing" status when receiving a remote start command via OCPP
- جديدWiFi disabled by default on devices without WiFi configured
- تحسينMore reliable RFID card reading with periodic reader reinitialization
- تحسينBetter cable connection detection and RFID timeout handling
- تحسينCDP - More stable network device discovery, preventing unnecessary register/unregister cycles
- تحسينImproved stability when applying configuration changes to the charger
- تحسينAutomatic migration of legacy pending OCPP messages after update
- تحسينImproved network handling when switching between manual and automatic IP configuration
- إصلاحPower factor value conversion for Carlo Gavazzi meters
- إصلاحImprovements in power measurement accuracy in single-phase or two-phase installations
- إصلاحOCPP - Smart Charging profiles with defined duration now applied correctly
- إصلاحOCPP - Local authentication cache overflow that could prevent charging sessions from startIing
- إصلاحOCPP - OCPP transactions stuck due to unreleased semaphores or null keys
-
- جديدEnhanced web server for accessing and editing charger properties
- جديدVisual improvements to the web server interface
- جديدPersistent price display on screen when the payment system is active
- جديدRefined error reporting to the cloud
- جديدPower loss detection
- جديدWi-Fi disable option from the installer panel
- جديدNew buzzer system implementation for white boards
- تحسينEnhanced RFID calibration with on-screen indicator during the process
- تحسينRFID reader no longer forcibly activates when OCPP or Payments are active; explicit configuration is respected
- تحسينRefined cable connect/disconnect notification on each event when payments are active
- تحسينOptimized RFID card readings
- تحسينOCPP - Improvements to the offline transaction queue
- تحسينInternal connection optimization and overall performance improvements
- إصلاحOCPP - Improved measurement value reporting
- إصلاحRefined out-of-range measurement error detection
-
- جديدSoftware-level leak detection enable/disable
- تحسينAdjusted cooldown time between charges when a leak is detected
- تحسينOCPP - Improvements to the offline transaction queue
-
- تحسينWhen OCPP is active, we now show on screen when card passed is not registered in central system.
- إصلاحAfter update OCPP image and QR is now recovered.
-
- إصلاحFixed issue where it didn't allow a remote start if a car is connected but not in an active transaction.
- إصلاحFixed issue in setup interface.
- إصلاحFixed monophasic Carlo Gavazzi measurer.
- إصلاحFixed OCPP issue where it wouldn't charge in connector 2 if connector 1 is charging.
-
- تحسينImproved network features mainly 4G connection.
-
- تحسينImproved OCPP charge handling.
- تحسينEnhanced reliability in the smart charging logic.
- تحسينImproved features when stopping a charge with invalid identifiers.
- تحسينImproved QR configuration for OCPP.
- تحسينImproved error handling when sensors or communication components fail.
- تحسينBetter log management to prevent the device’s storage from filling up.
- تحسينImproved USB connection features.
- تحسينImproved RFID calibration and detection display.
- تحسينImproved features related to Bluetooth.
- تحسينImproved dynamic power control allowing charge at minimum intensity if master is not detected.
-
- جديدManual timezone setting is now available – The user will be able to configure the timezone even if automatic detection is disabled
- جديدCreated a contingency page in case app is not running
- جديدAdded Italian option for screen
- جديدAdded default payment QR to pay without app
- جديدAdded new OCPP personalization options - The user can now set 2 QR codes on the screen
- تحسينImproved updater
- تحسينImproved network connections
- تحسينImproved OCPP meter values
- تحسينImproved discovering devices when dynamic control is active
- تحسينImproved user interface when updates are in progress
- تحسينLocal load balancing is now implemented as dynamic control based specific conditions
- تحسينImproved Bluetooth connection
- تحسينImproved 4g connections robustness
- تحسينImproved STM32 lock timings
- تحسينImproved OCPP now allows external intensity limits
- تحسينImproved data consumption
- إصلاحWhen locking a connector while charging, it now sends end charge telemetry correctly
- إصلاحFixed dynamic control issues
- إصلاحFixed Carlo Gavazzi power meter
- إصلاحFixed OCPP LMS, diagnostics, and charging profile clearing
-
- جديدAdded shared library
- جديدTimezone can be set manually
- جديدTime is now synced with Central System if OCPP is active
- تحسينImproved version/update manager
- تحسينImproved megabyte conversion of Network Monitor
- تحسينObtaining timezone now doesn't need to have correct time by using only http urls
- تحسينMobile usb device name is now obtained dynamically since more usb ports might be used due to TPV
- إصلاحFixed power control issues
- إصلاحFixed that when locking connector during a charge it now ends correctly
- إصلاحRecalculate reboot time when changing time with ble
- إصلاحWe now show on screen when non registered RFID is passed while OCPP is active
- إصلاحFixed OCPP freemode rfid issues
- إصلاحDuplicate StatusNotifications are removed from offline queue
- إصلاحFixed "infinite" OCPP offline queue issue
-
- جديدAPN can now be set manually
- تحسينWe now show on screen different wifi images depending on how strong signal is to let know the user how good the connection is
- تحسينGeneral OCPP improvements: we check connection to CS instead of internet for local functioning, we notify a real value now when there's a stop transaction due to power loss, fixed edge cases where connectivity is lost, new ocpp key MaxEVCurrentOffered implemented which limits charge with key instead of smart charging handler, safety mechanisms for ocpp to be more robust
- تحسينIn 4g, increased rssi range for "excellent" so that it indicates correctly when the reception is good
- تحسينImproved data consumption
- تحسينImproved robustness of update
- تحديثAccess point time increased to 15 minutes
- إصلاحHandled issues when SSID has whitespace
-
- إصلاحAccess point improvements.
- إصلاحFixed QA issues.
-
- جديدNew direct method to obtain additional information for Smart Charging.
- جديدFixed random reboot time.
- تحسينFixed unset RFID.
- تحسينFixed Unknown measurer and made distinction between Unknown measurer and wrongly configured measurer.
- تحسينOCPP Free mode can be toggled through OCPP keys.
- تحديثFixed BLE connection with iphone and fixed bluetooth communication error that appeared on app.
- تحديثNetwork improvements. No interface resets performed at boot which improves bootup time. Network changes now don't require reboot. When changing WIFI settings or ip ethernet settings, it connects after setting it instead of rebooting.
- إصلاحFixed issue where things on screen were missing in one connector chargers.
- إصلاحFixed time/timezone issue caused when the date is off by a few days.
- إصلاحNew property added to toggle if vehicle should be able to charge even though measurers aren't working ( Only works when OCPP, payments or dynamic control isn't enabled ).
-
- جديدReflect on screen when charge is paused.
- جديدMade reboot time random.
- إصلاحIncreased SAS token time to live of azure.
-
- جديدChanges made to reduce network usage that can be toggled on or off.
- جديدFixed case where config is corrupted or missing and would give trouble at startup.
- جديدWe now send dead letter if cpu gets too hot and cpu temperature is now logged.
- تحسينFixed OCPP inverted measurer error.
- تحسينAdded mechanism to disable or enable Wifi and bluetooth.
- تحسينWe now report information regarding which type of connection to the internet the e-charger has.
- تحديثChanged led colors. Switched State A (now white) and State B (now green) colors.
- إصلاحFixed set threshold values and neopixel leds of Stm32. We can now also obtain control pilot value from Stm32.
- إصلاحOCPP ConnectionTimeOut value can now be changed on the fly.
- إصلاحWe now report iccid of sim card is connected. If sim is connected but we can't obtain iccid, we send dead letter.
- إصلاحFixed log download of http interface.
-
- جديدLTE signal is now reflected correctly instead of always showing great signal.
- تحسينFixed wathdog reboot after doing hard reset.
-
- جديدAdded dynamic photovoltaic.
- جديدAdded dead letters: measurer fails and kernel error.
- جديدProperty "wifi_info" is now reported.
- جديدProperty "wifi_static" can be set through ble.
- جديدWe can now obtain statistics through direct method.
- جديدAdded individual log level for each type of logger.
- جديدAdded neopixel led type for stm32.
- جديدWe can now set threshold values with stm32 and get control pilot value if debug log of "Stm32" is activated.
- تحسينImprovements in dynamic control, fabrication, QA, Azure, OCPP, config handling, 4g, access point and stm32.
- تحسينWe now obtain timezone through url.
- تحسينRemoved raspbian logo and desktop during boot and added V2C logo.
- تحسينChanged default language after fabrication from english to spanish.
- تحديثGeneral bug fixes.
- إصلاحWhen downgrading we ensure that version we downgrade to is compatible.
-
- جديدFixed property "ocpp" change bug.
- تحسينProperties "powerweekday", "powerweekend" and "phase_map" can be changed through bluetooth.
- تحسينChanged configuration handling to differentiate internally and externally set variables so that externally set or obtained variables are handled accordingly following the property schemas.
- إصلاحWe now report wifi_static with static ip configuration.
- إصلاحStatistics are now saved locally.
-
- تحسينMeasurer fails are now registered with modbusrtumeasurer.
- تحسينScreen font bigger for small title.
- إصلاحValidate configuration with schemas during loading.
-
- جديدOCPP authorize can now function by connector.
- جديدOCPP WSS connection.
- جديدFixed OCPP parent id tag bug.
- جديدOCPP meter values now work for 3 phases.
- تحسينFixed error 3 not appearing on screen.
- تحسينFixed energy by hour bug.
- تحسينChanged measurer reading approach for faster reads.
- تحسينWith dynamic balancing we now show used and available power in frontend.
-
- تحسينWe show dynamic balancing information on screen.
- تحسينSimplified handling of configuration.
- تحسينImproved dynamic balancing.
-
- تحسينCharger won't reboot if car is in state B and OCPP or Payments is active.
- تحسينWhen car changes from state C to B, charge information will persist on screen.
- تحسينCurrent state charge now reports errors.
- تحسينAdded configuration property validation.
- إصلاحDirect method to obtain dynamic balancing information.
- إصلاحGeneral dynamic balancing improvements.
- إصلاحOCPP improvements.
-
- إصلاحChanged remaining set_basic_unreported_config to set_basic_config.
-
- جديدFix dynamic control bug, powerbytram is not being updated.
- جديدFixed bug where whitelist of reported items wasn't being applied and properties weren't being stored in database.
- تحسينRemoved non-repetitive logger.
- تحسينChanged access point interface to change apn, with manual mode or mobile operator mode.
- تحديثRefactored config charge box. Removed BASIC_UNREPORTED and created whitelist of properties to report.
- تحديثPhase map is now not applied to installation meters.
- إصلاحFixed payment bug where a charge couldn't be started properly if charge was started with the hose unlocked.
- إصلاحFix bug with power being zero, dynamic control failing when there are no connectors.
- 3.1.8تحديثForce WIFI and bluetooth GPIO pins for compute module 4 to work.
- 3.1.7تحديثForce 4g GPIO pins for compute module 4 to work.
-
- تحسينWhen we detect that measurers aren't working, we send an unblock command in case there's a charge and the charger has lost power.
- تحسينCreate section BASIC_UNREPORTED for properties that are used but we don't want to report.
- تحسينLocked value has persistance when measurers fail.
- إصلاحWhen we don't receive petitions from chromium we now press enter and Ctrl+F5 if there's anything we need to accept.
-
- إصلاحChanging WIFI configuration with bluetooth now reboots the charge point.
-
- تحسينFixed configuration file so that software works with compute module 3 and 4.
- تحسينChanged reboot logic. It will now reboot if there's a car connected but charge is not allowed.
- إصلاحChanged payments qr code.
- إصلاحWe can change log level with property.
-
- إصلاحMeter values fixed. We now send wh instead of kwh.
-
- جديدPause is now reset when it goes back to state A.
- جديدShow measurer error as "Error 3" on connector. Behaviour is that connector is locked until it's fixed.
- جديدSet wire connected again.
- تحسينFixed general network errors. Improved access point and wifi connectivity.
- إصلاحFixed error where timezone wasn't set correctly so time appeared incorrectly.
- إصلاحFixed payment_max_mode timeout bug.
-
- جديدFixed power, it was shown in W and is now in Kw.
- تحسينChange timezone automatically.
- إصلاحAdded triphasic phoenix contact measurer.
- إزالةFixed removal of grey notification update.
-
- جديدWhenever there's an action that provokes rebooting, it will show on screen that it's going to reboot and the cause.
- جديدScreen orientation can now be set and depending on parameter.
- جديدAdded error message 1 and 2.
- جديدBluetooth patch so that bluetooth initialization takes less time.
- جديدCreated patch system. System level changes will be applied with this system.
- تحسينMeasurer refactoring.
- تحسينImei obtention improved.
- تحسينInitial version of bluetooth finished: Obtain properties change basic properties, program charge, reboot, add rfid and change wifi.
- تحسينBoot improvements. "Page not found" isn't shown anymore. Boot is faster. There's a gif indicating that system is starting.
- تحسينObsolete properties are now deleted automatically so that they aren't reported.
- تحديثRFID can now function with payments. If RFID is enabled with payments, registered cards will be able to start charges. If RFID is disabled with payments, no card will be able to start a charge.
- إصلاحLimited number of messages we can send to iothub.
- إصلاحIn OCPP, fixed sending of meter values. Now sending in wh and not in kwh.
- إصلاحBoot patch so that GPIO pin initialization takes less time.
- إصلاحMonophasic measurer Eastron SDM220 implemented.
- إصلاحImproved robustness on all direct methods.
- إصلاحFixed bug where it didn't reconnect properly to iothub when it disconnected.
- إصلاحCreated direct method to put a QR code on the OCPP screen.
- إزالةRemoved wire_connected event telemetry.
- 3.0.9إصلاحFixed ocpp meter value Energy.Active.Import, when measurer is flipped.
-
- تحديثFixed error where e-Charger couldn't obtain dns when connected with WIFI.
- إصلاحFixed local load balancing when one connector was charging. Now when one connector is charging, it will charge at the set intensity.
- 3.0.7إصلاحFixed ocpp Remote Start Transaction and Remote Stop Transaction.
- 3.0.6إصلاحFixed error that ocurred in ocpp where it didn't clear properly the idtag when finishing a transaction.
-
- تحديثChanged access point ip from 192.168.44.1 to 192.168.4.1
- تحديثWe now report the charger's state instead of the requested vehicle state.
- تحديثChanged access point master password.
- إصلاحFixed websocket connection issue with nuitka compilation.
-
- تحسينImproved update logs.
- 3.0.3جديدMoved Version from center to right side and added V. before the version number.
- 3.0.2تحسينSTM will now detect SPI bus communication errors and will automatically reset.
-
- جديدScreen now shows when RFID card is registered.
- جديدTop bar now shows version and if access point is accessible.
- جديدAccess point interface now has, local load balancing, rfid card registering and log download.
- جديدCheck that compute module and board have been created properly.
- تحسينScreen is now monitored so that it refreshes in the case that no requests have been made after 15 seconds.
- تحسينQA diagnostic is obtained through access point.
- تحسينReduced access point available time to 10 minutes.
- إصلاحFixed bug where connector stopped working properly when sending intensity 0.
-
- جديدInitial Version
6 من 46