Posodobitve za Trydan in Trydan Pro
Nenehno delamo na izboljšanju funkcionalnosti polnilnikov Trydan in Trydan Pro. Tukaj boste našli najnovejšo različico našega e-Chargerja in najnovejše izvedene posodobitve.
Najnovejša različica
2.5.2
Trydan in Trydan Pro
2.5.2Najnovejša različica
New inverters (Solplanet/AISWEI, Hoymiles, Huawei without dongle), battery discharge control, unified statistics in mixed three-phase, and cybersecurity improvements in Bluetooth.
- NovoDirect query of OCPP status
- NovoNew Solplanet/AISWEI Inverter
- NovoNew Hoymiles Inverter
- NovoBattery discharge control: GoodWe, SolarEdge
- NovoHuawei inverters direct connection without Dongle
- NovoUnified statistics in mixed three-phase charging (the session is not divided when switching between three-phase and single-phase)
- NovoNew "Unlimited" Wake-up 5 mode available from the LCD
- NovoImprovements in Bluetooth cybersecurity
- IzboljšavaFixes in FV mode + Minimum power
- IzboljšavaOCPP: duplicate BootNotifications are avoided
- IzboljšavaSecurity menu lock during vehicle charging
- IzboljšavaImprovements for Linky-LORA
Prejšnje različice 46
-
- NovoCompatibility with SigEnergy inverters
- NovoNew model of Ingeteam three-phase inverter (ISS 3PLAY)
- NovoWiFi connection for Deye inverters via Elfin
- NovoExpansion to 105 RFID cards
- NovoPAP/CHAP authentication for 4G connection
- NovoMore stable OCPP connections
- IzboljšavaReading the P1 and Victron meters is more reliable in the event of communication failures.
- IzboljšavaStability of mixed three-phase charging
- IzboljšavaError reporting and diagnostic system
- IzboljšavaImprovement of home battery charging priority in PV charging modes
-
- NovoManagement of home battery discharge in charging profiles
- NovoUnlocking the Trydan by smartphone proximity
- NovoNew models of SofarSolar and Azzurro inverters
- NovoAdded current and voltage per phase in Home Assistant and Modbus API.
- NovoWiFi connection in Deye inverters
- NovoIncrease of up to 80 RFID cards
- NovoBattery compatibility in SolarEdge inverters
- NovoScroll text for long texts
- IzboljšavaOptimization of Ethernet network interface
- IzboljšavaImprovements in the Modbus TCP client
- IzboljšavaImprovements in mixed three-phase charging
- IzboljšavaImprovement of texts in German
- IzboljšavaIncrease the voltage range of the installation from the control panel.
-
- PopravekOCPP password bug
- PopravekProblems connecting to CSMS after restarts
-
- NovoTarget charge kWh
- NovoNew SMA Sunny Boy model
- NovoNew Fronius model with battery
- NovoSelect Modbus API address ID
- NovoNew Deye models
- NovoSofar Solar inverters
- NovoAzzurro inverters
- NovoSelect MID address
- NovoEMMA Huawei
- NovoSecurity Profile 2 OCPP (wss + auth + CA cert)
- NovoPrivate 4G SIMs in OCPP
- NovoOcppFreeMode
- NovoOCPP internal queue messages
- IzboljšavaTime synchronization
- IzboljšavaPower plate measurements 1.0
- IzboljšavaWiFi improvements
- PopravekExclusive mode bug with batteries
- PopravekCoordinate "ContractedPower" and load profiles with HTTP API.
- PopravekImprove RFID errors
- PopravekMixed load bug
- PopravekBug photovoltaic mode + minimum
- PopravekBug statistics without FV via BLE
-
- NovoMIFARE Ultralight RFID cards
- IzboljšavaMore robust OTA update
- PopravekBug management autolock with payments mode
- PopravekBug in payments mode with RFID
-
- IzboljšavaInstallation problem readings
- IzboljšavaImprovement in BYD mode
- PopravekBug with Wibeee inverter
-
- NovoObtain firmware version via Modbus
- NovoGoodWe via Modbus TCP
- NovoOCPP: FirmwareManagement
- NovoAutolock
- NovoNew MID models
- NovoNew wake-up modes
- NovoAllow changing the charging type in HA (single-phase, three-phase, or mixed)
- NovoLinky meter for French meters
- NovoModbus termination resistance
- NovoReading individual properties HTTP API
- NovoTurn off/Turn on logo and LCD from HTTP API
- PosodobljenoImprovements in dynamic control
- PosodobljenoImprovement in Sungrow inverter measurements
- PosodobljenoImprovements in the OTA update
- PosodobljenoImprovements in the button panel menu
- PosodobljenoNew Deye models
- PosodobljenoOCPP: improvement in MeterValues
- PosodobljenoOCPP: send StatusNotification "Faulted" with errors and warnings
- PosodobljenoOCPP: publish current version
- PosodobljenoOCPP: BootNotification timeout
- PosodobljenoNew NTP servers
- PosodobljenoImproved WI-FI scanning
- PosodobljenoImprovement in P1 meter
- PosodobljenoImprovement in remote logs
- PosodobljenoIoT call limitation per charger
- PosodobljenoImprove RAM memory
- PosodobljenoStability via Ethernet
- PosodobljenoCorrected translations
- PopravekError "Waiting for Power"
- PopravekBug with RFID cards with long names
- PopravekBug when requesting the list of Wi-Fi SSIDs via Bluetooth.
- PopravekImprove statistics via Bluetooth
- PopravekLocal balancing improvements for up to 10 devices
- PopravekBug when sending RFID code in the statistics
- PopravekBug with Exclusive PV mode and batteries
-
- NovoStatic power control is added (only with Trydan consumption).
- NovoMixed charging adapts to European rates.
- NovoPower control programming with phase limits is allowed.
- NovoThe power control adapts to European countries with phase current limits.
- PosodobljenoThe power control algorithm has been modified step by step to apply PID modulation.
- PosodobljenoThe static power control between sockets or between e-Chargers is improved.
- PopravekThe failure of remote records is avoided when a disconnection occurs.
-
- PopravekBug DTSU666-G meters
-
- IzboljšavaImprovement in Wake Mode
- PopravekFixed bug when changing the port in MQTT.
-
- NovoEcoCharging to schedule charging automatically during the cheapest daylight hours.
- NovoTurning on and off LEDs via Modbus TCP/RTU. Option to adjust and query the intensity of the LEDs and the LCD screen.
- NovoCompatibility with the new Chint DTSU666-G meter model, allowing for broader integration in various installations.
- NovoFirmware update of the V2C ControlBox meter (2.0) via the access point (AP) and the mobile app.
- NovoImprovement in the reading of electrical signals: State F detection implemented, enhancing the system's ability to recognize and respond to different operating conditions.
- NovoImprovement in the reading of electrical signals: The reading of the input PWM signal has been implemented using DMA (Direct Memory Access), enhancing efficiency and reducing processing load.
- NovoOCPP: Detailed reasons for OCPP functions, providing more comprehensive information about the actions taken and facilitating the diagnosis and analysis of events.
- NovoOCPP: The ability to operate in offline modes, allowing the charger to function correctly even without a connection to the server. Pending messages are stored and sent once the connection is restored, ensuring reliable and consistent communication.
- NovoOCPP: New OCPP state machine. Now, the system connects to the OCPP Central Server (CS) and receives most commands, improving interoperability and remote control.
- IzboljšavaReading the power value of the batteries in Goodwe EH and ET inverters.
- IzboljšavaSystem optimization: reduction of RAM usage, improving overall system stability and performance.
- IzboljšavaImprovement in the reading of electrical signals: Enhanced verification for state E, in addition to omitting zero values from the DMA to avoid incorrect readings.
- IzboljšavaImprovement in reading electrical signals: Now the CP (Control Pilot) signal is read using a parallel task, which enhances the accuracy and response of the system when interacting with the electric vehicle.
- IzboljšavaImprovement in the reading of electrical signals: Enhanced stability during this calibration process through the app.
- IzboljšavaOCPP: Host name resolution. Optimization of libraries to improve DNS resolution and the reliability of secure connections via Secure WebSocket (WSS), increasing stability in communication with remote servers.
- IzboljšavaOCPP: Ensuring that all important information reaches the server once the connection is restored through a persistent message queue.
- IzboljšavaOCPP: Status notifications. Improving communication with the central server for sending status notifications.
- PopravekOCPP: Fixed a false card detection alert that appeared when starting the system, avoiding confusion and improving the user experience.
-
- NovoVoltage reading and writing manual for installation for Modbus TCP and HTTP integrations.
- NovoSAJ hybrid inverters
- NovoShelly Pro meters
- NovoInformation on the response /RealtimeData from http at the request of the developer of the official HA integration.
- NovoDirect methods to activate the access point (WiFi AP) and ping a specific IP.
- NovoTopic trydan_v2c_voltage to write the installation voltage via MQTT.
- IzboljšavaLeak detection
- IzboljšavaMemory management to avoid unexpected restarts with OCPP and the deletion of scheduled power profiles.
- IzboljšavaModbus TCP connections of Trydan and Trydan Pro with Huawei, Fronius, Victron, Ingeteam, SolarEdge, Kostal Plenticore, SMA, and SAJ Hybrid in error 252.
- IzboljšavaVisualization of the RFID card authentication process in OCPP
- IzboljšavaThe memory used in JSON and OCPP goes to the SPI RAM.
- PopravekInformation about RFID cards to the OCPP platform standard for compatibility with platforms like E-flux, Monta…
- PopravekCollision between the SPI elements (RFID, Ethernet, and GPIO extender) of Trydan Pro
-
- NovoAdaptation of OCPP to new central systems
- NovoNew Deye models
- IzboljšavaImprovements in the direction detection of the V2C 2.0 control box
- PopravekLEDs blink when there is no connection.
- PopravekBug in Greenheiss hybrid
-
- NovoDeye / Turbo Energy three-phase
- NovoShelly Pro EM and Shelly Pro 3EM (Beta)
- IzboljšavaShow text on bidirectional meters
- IzboljšavaReadings with Fronius and DTSU666
- IzboljšavaReaction times in the leak detector
- IzboljšavaShow Waiting for Charge in Stop mode
- PopravekBug with French language
- PopravekRaise the HTTP server via Ethernet
- PopravekBug in payments
- PopravekRead-only in the OCPP properties
- PopravekSave power segments via Bluetooth on some devices.
- PopravekShelly Portugal measurements
-
- NovoLive Remote Logs
- IzboljšavaShow stop due to dynamic control
- IzboljšavaRestarts due to reconnection attempts
- IzboljšavaQA Protocol
- IzboljšavaVoltage and Temperature Reading Power PCB
- PopravekNaN measurement on some meters
- PopravekError in Home Wizard readings
-
- IzboljšavaPerformance improvement and future compatibility between Trydan and Trydan Pro.
- IzboljšavaImprovements in OCPP protocol
- IzboljšavaImprovements in the QA process
- IzboljšavaImprovement in memory usage
- IzboljšavaMore robust statistics
-
- NovoNetworks with WPA3 security
- NovoNew BLE (NimBLE)
- Novoe-keys via BLE connection
- NovoNew language: Romanian
- NovoEnphase version 7.x.x, Solis with batteries
- NovoAdaptation of the i2c power board
- IzboljšavaAzure library update
- IzboljšavaUpdate of ESP-IDF and Arduino-ESP32 libraries
- IzboljšavaInvestor communication via WiFi connection without Internet
- IzboljšavaImprovement in V2C 2.0 meter refresh rate
- IzboljšavaImprovement in OCPP, adaptation to support disconnections
- IzboljšavaImprovement in key fob detection
- IzboljšavaImproved refresh rate
- IzboljšavaImprovement of values in Huawei, improvement of Chint in Huawei, and end of charge review.
- PopravekModification of Deye/Turbo Energy batteries
- PopravekCustomizable MQTT topics and username/password
- PopravekDisconnection statistics report
- PopravekBLE compatibility of iPhone
- PopravekOperation of V2C 2.0 meter at night
- PopravekAutomatic date and time
- PopravekInteraction with Megane
-
- NovoBug in photovoltaic three-phase mode
- IzboljšavaWiFi recovery routine
-
- NovoMixed three-phase charging available through the physical menu.
- NovoAdded three-phase MID Meter
- NovoInclusion of server ID 2 in SolarEdge inverters
- NovoAdded Modbus registers with the meter measurement.
- NovoHTTP commands added for integration with HA.
- NovoEnphase Envoy Inverter (beta) (versions 5.x.x)
- NovoV2C 2.0 error detection of clamp not connected
- NovoMQTT Slave with user/password authentication and customizable topics (beta)
- IzboljšavaImprovement of the WatchDog to prevent system freezing
- IzboljšavaImprovement of nearby WiFi scanning
- IzboljšavaBluetoothLE service reconnection protocol
- IzboljšavaWiFi optimization IRAM and affinity with the Azure task
- IzboljšavaReconnection protocol in the absence of WiFi
- IzboljšavaFactory reset
- IzboljšavaThe error code and LED interface
- IzboljšavaImproved the Isolated Installation mode and zero feed-in.
- IzboljšavaReduction in cut-off time through dynamic control to 1 min
- IzboljšavaAutomatic detection of time and time zone
- IzboljšavaThe optimization and refactoring of the measurement slaves
- IzboljšavaUnlocking with BLE Tag
- PopravekOccasional LCD freezes
- PopravekFalse positives from the leak detector
- PopravekProblems with the MID Meter
- PopravekLED error during update
- PopravekDefault value for JSON type variables
- PopravekMeasurement at 0 in Deye/TurboEnergy Inverter
- PopravekVisual errors and local balancing address assignment
-
- NovoSolar Discount on Shortcuts
- NovoDeye/TurboEnergy Inverter Beta
- NovoPhoenix Contact meter
- NovoCarlo Gavazzi meter
- IzboljšavaOCPP improvements and tested in MONTA
- IzboljšavaProblems in dynamic control
- IzboljšavaReconnections and WiFi Stability
- PopravekFrozen LCD
-
- NovoIsolated Mode in Photovoltaic Modes
- NovoDutch, Danish, and Valencian
- NovoLeak sensor modes (installer menu)
- NovoMID meter (installer menu)
- NovoNew Ingeteam protocol (Battery Management)
- NovoThree-phase meters DTSU666
- NovoSDM three-phase meters
- IzboljšavaLocal Balancing Protocol and priorities
- IzboljšavaDetection of ports and hosts in OCPP
- IzboljšavaStable version of SMA Sunny Boy
- IzboljšavaPortuguese version of Wibeee
- IzboljšavaFronius measuring home consumption
- PopravekUnexpected locks and unlocks
- PopravekWhite blinking in locked mode removed
- PopravekError selecting the slaves in beta
- PopravekError of SolarEdge three-phase inverters
-
- NovoChanges and improvements in calibration
-
- IzboljšavaCalibration adapted to the new hardware
- PopravekData analysis in Kostal Piko fixed
-
- NovoLocal balancing between Trydans available via WiFi or wired connection.
- NovoSDM-220/320/120 (Tested with the Eastron brand)
- NovoDDSU-666 Meter (Common in Huawei installations)
- NovoSelf-calibrating without the need for a car
- NovoManual hour available
- NovoHTTP requests to manage the logs
- NovoNew Modbus Registers
- NovoGreenheiss inverters
- NovoSAJ inverters
- NovoWired Solis inverters
- NovoResponse time in configurable dynamic control
- IzboljšavaConfigurable installation voltage
- IzboljšavaNew manufacturing process
- IzboljšavaIncluded Shelly three-phase but without FV measurement.
- IzboljšavaCar consumption via MQTT fixed
- IzboljšavaImproved and more intuitive physical menu
- ZdružljivostBeta models of Goodwe: the battery measurement is canceled.
- PopravekBug in Max and Min Intensity via Modbus fixed.
- PopravekFalse positives in the leak detector fixed
-
- NovoPrevention of conflicts between slaves and the cloud
- PopravekGoodWe conflicts and Azure initialization
- PopravekFix in Shelly with only three-phase.
-
- IzboljšavaPending statistics will be sent only once.
- IzboljšavaShelly 3EM three-phase and modification for Portugal
- PopravekModbus Multiple Readings Hotfix
-
- NovoNew Modbus registers
- NovoRFID reader in alpha version
- NovoSolaX X3 híbrido compatible
- NovoAvailable calibration and shortcuts via WiFi
- IzboljšavaOCPP Improvements
- IzboljšavaImprovement in WiFi scanning
- IzboljšavaImprovement in reconnection routines
- PopravekBluetooth timezone failure
- PopravekError in Trydan synchronization - APP
- PopravekStatic IP configuration in Trydan via WiFi
- PopravekError saving Modbus parameters
-
- NovoNew method for calibrating communication with the car
- NovoBeta version of the GoodWe ET/EH/BT/BH
- IzboljšavaImprovement in the communication analysis with the car
-
- NovoAuto lock after 60 seconds without a car (shortcut)
- NovoModification for Three-Phase Installations in Portugal for V2C 2.0
- NovoKostal Piko is added.
- IzboljšavaReformulation of the Dynamic Control Algorithm
- IzboljšavaImprovement in the refresh rate of Huawei inverters
- IzboljšavaSolarEdge stable (Meter measuring export)
- IzboljšavaStable version of GoodWe
- IzboljšavaDetection of state D and E according to protocol
- IzboljšavaImproved QA process
- PopravekStored in memory after writings via Modbus TCP and RTU
- PopravekBug in the FV measurements and peaks resolved for V2C 2.0
-
- NovoGoodWe in beta version
- NovoCheck the charging status to avoid short charges (Car at 100% or on scheduled charging)
- IzboljšavaMQTT in stable version
- IzboljšavaVictron in stable version
- IzboljšavaImproved connection with Azure
-
- NovoMQTT slave beta version
- IzboljšavaDetection of power direction in Wibeee
- PopravekThe Victron and SolarEdge inverters were bringing down the system.
-
- NovoSolarEdge inverter added (Beta)
- NovoVictron inverter added (Beta)
- NovoAutolock enabled in shortcut (60 s)
- NovoAutomatic time zone detection
- NovoAlternative meter for car consumption (RS485)
- NovoFV Exclusive with configurable variation
- NovoNew Languages (French, Italian, and German)
- PopravekFixed error in minimum power mode.
-
- IzboljšavaImprovements in Dynamic Control with batteries
- IzboljšavaImprovements in Dynamic Control in Three-Phase Installations (Exclusive Mode and Minimum Power)
- PopravekResolved the IP configuration issues for Trydan with WiFi and BLE.
- PopravekResolved the issues with the IP configuration of Shelly BLE.
-
- NovoInclusion of the Wibeee meter
- NovoSlave 2.0 compatible with Type 1 and Type 2 installation
- NovoChange in the established connection blinking
- NovoDetection and measurement of bifacial load
- NovoImprovement in the collection and transmission of charging data
- NovoAlternative Meter Phoenix Contact (ModbusRTU)
- NovoModbusRTU in Trydan (simultaneous slave and master)
- NovoStatic IP configuration in Trydan
- NovoPossibility to select the IP in Shelly
- IzboljšavaInclusion of maximum intensity in OCPP (as a property)
- IzboljšavaImprovement in the reading of Solax inverters
- IzboljšavaInclusion of batteries in Huawei, Ingeteam, and Fronius inverters.
- IzboljšavaModbusRTU and Modbus TCP server in Trydan
- PosodobljenoFirst stable version of Ingeteam
- PosodobljenoImprovement in the speed of the leak detector
-
- PopravekError solution in manufacturing when saving WiFi
-
- NovoEliminate false communication errors from the slaves.
- NovoSave the first Shelly that Trydan connects to.
- PosodobljenoWith dynamic control disabled, maintain intensity after finishProgramedSaveMode.
-
- IzboljšavaImprovement in telemetry recovery in OCPP
- IzboljšavaImprovement in scanning nearby WiFi networks
-
- NovoInternal Azure ping every 15 seconds to detect disconnections.
- NovoSeparate reconnections to avoid crashing the server.
- NovoOCPP adaptation to work with Home Assistant
- IzboljšavaMigration of the I2C for the clock and LCD to native idf
-
- IzboljšavaIncrease maximum binary size in local webServer
- PopravekRecovery of OCPP transactions to prevent telemetry failures
-
- NovoThe configuration of different IDs for Huawei inverters is added.
- IzboljšavaCorrection of the power reading of the house
- PopravekCorrection of the lock due to Payment Mode and OCPP after deactivation of these.
-
- NovoPayment Method (V2C Payments)
- NovoOCPP Protocol
- IzboljšavaImprovement of WiFi and Bluetooth stability and reconnection
- PopravekReconnection improvement in the inverters and fix after the update of the Huawei SUN2000.
-
- PopravekCorrection of the maximum file size for updates on Local Server
-
- NovoList of available WiFi networks from Trydan (for viewing from iPhone and Android)
- IzboljšavaReconnection with V2C Cloud after communication loss
- PopravekCorrected Shelly and Solax routines
-
- NovoShortcuts on the buttons: Lock and Charging Schedule
- NovoLocal Web page for configuring the Trydan accessible via AP or STA WiFi
- NovoAP mode when the configured WiFi is not available
- IzboljšavaImprovement in LED error codes
- IzboljšavaAdaptation for compatibility with Huawei inverters
-
- NovoWe added connectivity with Fronius inverters.
- IzboljšavaImprovements in screen writing and removal of strange characters
- IzboljšavaImprovement in the transmission of statistics via both WiFi and BLE.
-
- NovoError correction x and y
6 od 46