Integración del inversor Solis con Trydan
The Trydan charging point is compatible with the entire range of Solis inverters. The installation of Solis inverters is carried out via RS485 Modbus communication. This connection must be made using a cable directly to the inverter; wireless (WiFi) connections are not supported. This approach ensures a more stable configuration.
Steps for cable connection to the Solis inverter
To enable RS485 Modbus communication, a special connector provided by the manufacturer/distributor and a UTP cable are required. These will be connected according to the diagram in Step 2, with the cable linked to the Trydan e-Charger terminating in a correctly crimped RJ-45 connector as shown in Step 4.
RJ-45 connector Trydan
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
A | B |
Special connector
Solis inverter configuration in the V2C Cloud App
Access the V2C Cloud application, choose the charging point, and access the configuration section.
Go to dynamic power control and choose inverter in the ‘device type’ tab. Select Solis in the ‘inverter type’ section and the appropriate installation in each situation.
It is essential to save the configuration to ensure the correct operation of the dynamic power control.
Once properly configured, you can customise it according to the specific requirements of each situation.