Optimise your electric charging experience with Modbus Feeder, an innovative option that allows us to send to the Trydan charging point all the necessary values to perform dynamic charge control. This system allows the e-Charger to perform efficient load balancing, adjusting to the predefined parameters for more efficient charging.
Steps for activating and configuring dynamic load control via Modbus Feeder
To be able to execute this functionality correctly, do not forget to activate and save the configuration.
The values are written to the following registers;
WRITE_ADDRESS_GRID_POWER | 6022 | 1786 | Int | Modbus Feeder config in Dynamic Power Control DPC (send information of grid consumption) Positive or Negative values |
WRITE_ADDRESS_SUN_POWER | 6023 | 1787 | Int | Modbus Feeder config in Dynamic Power Control DPC (send information of solar Energy) Positive Values |
WRITE_ADDRESS_BATTERY_POWER | 6024 | 1788 | Int | Modbus Feeder config in Dynamic Power Control DPC (send information of power of Battery) Positive or Negative values |