Pole Pro exploded view

The exploded view shows the internal and external elements that compose the Pole Pro. Refer to the necessary information for performing maintenance or repair tasks on the e-Charger Pole Pro, both in its floor and wall-mounted versions

Floor version

Wall version

Internal components

1. Socket
2. Label
3. LED lighting
4. Lock

External components

5. Display
6. RFID
7. LTE antenna
8. 12V power sources
9. Meters
10. Automatic differential/combined 16A
11. 230V o 400V General 80A
12. Control board
13. Contactors
14. 230V or 400V automatic/differential combined 40A
15. Earth terminal block

Control board components

16. 12V power supply connection
17. Contactor control
18. Buzzer
19. Input and output terminals
20. USB (x2)
21. HDMI
22. SIM card
23. Compute module + heat sink
24. RS485 Modbus
25. Ethernet

Control board connection

CN14
LEFT_CON_1 1.
 LEFT_CON_2 2.

CN15
LEAK_CON 1.

J1
LEFT_CP 1.
LEFT_PP 2.
LEFT_LOCKOUT_1 3.
LEFT_LOCKOUT_2 4.
LOCK_SENSOR 5.
RS485_A 6.
PROTECTION_TRIGGER 7.
GND 8.
+12V 9.
R_LED_LEFT_CON 10.
G_LED_LEFT_CON 11.
B_LED_LEFT_CON 12.
GND 13.
RS485_B 14.
WELDING_DETECTION 15.
GND 16.

CN1. Ground

CN16
2. RIGHT_CON_2
1.  RIGHT_CON_1

CN17
1.
LEAK_CON

J2
1.
RIGHT_CP
2. RIGHT_PP
3. RIGHT_LOCKOUT_1
4. RIGHT_LOCKOUT_2
5. LOCK_SENSOR
6. RIGHT_LOCKOUT_2
7. PROTECTION_TRIGGER
8. GND
9.
+12V
10. R_LED_RIGHT_CON
11.
G_LED_RIGHT_CON
12.
B_LED_RIGHT_CON
13.
GND
14.
POWER_FAILURE
15.
WELDING_DETECTION
16.
GND

CN14
1. LEFT_CON_1
2. LEFT_CON_1

CN15
1.
LEAK_CON

J1
1.
LEFT_CP
2. LEFT_PP
3. LEFT_LOCKOUT_1
4. LEFT_LOCKOUT_2
5. LOCK_SENSOR
6. RS485_A
7. PROTECTION_TRIGGER
8. GND
9. +12V
10. R_LED_LEFT_CON
11. G_LED_LEFT_CON
12. B_LED_LEFT_CON
13. GND
14. RS485_B
15. WELDING_DETECTION
16. GND

CN1. Ground

CN16
2. RIGHT_CON_2
1. RIGHT_CON_1

CN17
1.
LEAK_CON

J2
1. RIGHT_CP
2. RIGHT_PP
3. RIGHT_LOCKOUT_1
4. RIGHT_LOCKOUT_2
5. LOCK_SENSOR
6. GND
7. PROTECTION_TRIGGER
8. GND
9.
+12V
10. R_LED_RIGHT_CON
11.
G_LED_RIGHT_CON
12.
B_LED_RIGHT_CON
13. GND
14. POWER_FAILURE
15. WELDING_DETECTION
16.
GND

Contactors CN14 and CN16 are connected to paragraph 13 of the section ‘Internal components’.