Pole Pro atjauninājumi
Mēs nepārtraukti strādājam, lai uzlabotu Pole Pro funkcionalitāti. Šeit atradīsi jaunāko mūsu e-Charger versiju un pēdējos veiktos atjauninājumus.
Jaunākā versija
6.1.3
Pole Pro
Jums ir iepriekšējais Pole? Skatiet tā atjauninājumus.
6.1.3Jaunākā versija
- LabojumsThe charger no longer hangs when rebooting while shutting down the 4G module or dynamic power control
Iepriekšējās versijas 46
- 6.1.2LabojumsOCPP security event notifications are no longer sent when the connection uses no security profile (profile 0), since some central systems do not support them
-
- LabojumsCorrected default APN for Wireless Logic SIM cards in Belgium
-
- JaunumsAudible buzzer feedback
- JaunumsSupport for registering multiple RFID cards
- JaunumsReading of the installation meter over Modbus RS485 on DC chargers
- JaunumsDynamic power control for DC installations — master and slave units now share and honor the installation power limit
- JaunumsLive display of actual consumption versus offered current on the charger screen
- JaunumsOn-screen guidance walks the user through registering an RFID card
- JaunumsOCPP connection password can now be set from the Cloud and Bluetooth
- JaunumsOCPP now supports security profiles, encrypted TLS connections and Basic Authentication for the central system
- UzlabojumsLanguage codes standardized to the ISO 639-1 format
- UzlabojumsReduced volume of messages sent to the Cloud
- UzlabojumsTime synchronization with the CSMS no longer floods the system log
- UzlabojumsLog rotation no longer loses history when the disk is full
- UzlabojumsSafer firmware updates
- UzlabojumsMore reliable connectivity with automatic failover between Ethernet and 4G
- UzlabojumsCharges history now loads page by page instead of the whole history at once, for a faster tab
- LabojumsMeasurer error message now reads clearly
- LabojumsMore accurate meter-reading validation
- LabojumsCharge metrics are preserved if a charge is interrupted unexpectedly
- LabojumsScreen orientation set in configuration is now applied correctly
- LabojumsFree-charge mode could not be disabled from the installer panel
- LabojumsDynamic power limit was not applied at tariff/hour boundaries, briefly leaving an installation without a limit
- LabojumsResolved random service restarts (crashes) caused by network device discovery
-
- UzlabojumsMore reliable RFID card reading with optimized antenna configuration from first use
- UzlabojumsImproved stability and responsiveness of the charger's web interface
-
- JaunumsOCPP - Immediate "Preparing" status when receiving a remote start command via OCPP
- JaunumsWiFi disabled by default on devices without WiFi configured
- UzlabojumsMore reliable RFID card reading with periodic reader reinitialization
- UzlabojumsBetter cable connection detection and RFID timeout handling
- UzlabojumsCDP - More stable network device discovery, preventing unnecessary register/unregister cycles
- UzlabojumsImproved stability when applying configuration changes to the charger
- UzlabojumsAutomatic migration of legacy pending OCPP messages after update
- UzlabojumsImproved network handling when switching between manual and automatic IP configuration
- LabojumsPower factor value conversion for Carlo Gavazzi meters
- LabojumsImprovements in power measurement accuracy in single-phase or two-phase installations
- LabojumsOCPP - Smart Charging profiles with defined duration now applied correctly
- LabojumsOCPP - Local authentication cache overflow that could prevent charging sessions from startIing
- LabojumsOCPP - OCPP transactions stuck due to unreleased semaphores or null keys
-
- JaunumsEnhanced web server for accessing and editing charger properties
- JaunumsVisual improvements to the web server interface
- JaunumsPersistent price display on screen when the payment system is active
- JaunumsRefined error reporting to the cloud
- JaunumsPower loss detection
- JaunumsWi-Fi disable option from the installer panel
- JaunumsNew buzzer system implementation for white boards
- UzlabojumsEnhanced RFID calibration with on-screen indicator during the process
- UzlabojumsRFID reader no longer forcibly activates when OCPP or Payments are active; explicit configuration is respected
- UzlabojumsRefined cable connect/disconnect notification on each event when payments are active
- UzlabojumsOptimized RFID card readings
- UzlabojumsOCPP - Improvements to the offline transaction queue
- UzlabojumsInternal connection optimization and overall performance improvements
- LabojumsOCPP - Improved measurement value reporting
- LabojumsRefined out-of-range measurement error detection
-
- JaunumsSoftware-level leak detection enable/disable
- UzlabojumsAdjusted cooldown time between charges when a leak is detected
- UzlabojumsOCPP - Improvements to the offline transaction queue
-
- UzlabojumsWhen OCPP is active, we now show on screen when card passed is not registered in central system.
- LabojumsAfter update OCPP image and QR is now recovered.
-
- LabojumsFixed issue where it didn't allow a remote start if a car is connected but not in an active transaction.
- LabojumsFixed issue in setup interface.
- LabojumsFixed monophasic Carlo Gavazzi measurer.
- LabojumsFixed OCPP issue where it wouldn't charge in connector 2 if connector 1 is charging.
-
- UzlabojumsImproved network features mainly 4G connection.
-
- UzlabojumsImproved OCPP charge handling.
- UzlabojumsEnhanced reliability in the smart charging logic.
- UzlabojumsImproved features when stopping a charge with invalid identifiers.
- UzlabojumsImproved QR configuration for OCPP.
- UzlabojumsImproved error handling when sensors or communication components fail.
- UzlabojumsBetter log management to prevent the device’s storage from filling up.
- UzlabojumsImproved USB connection features.
- UzlabojumsImproved RFID calibration and detection display.
- UzlabojumsImproved features related to Bluetooth.
- UzlabojumsImproved dynamic power control allowing charge at minimum intensity if master is not detected.
-
- JaunumsManual timezone setting is now available – The user will be able to configure the timezone even if automatic detection is disabled
- JaunumsCreated a contingency page in case app is not running
- JaunumsAdded Italian option for screen
- JaunumsAdded default payment QR to pay without app
- JaunumsAdded new OCPP personalization options - The user can now set 2 QR codes on the screen
- UzlabojumsImproved updater
- UzlabojumsImproved network connections
- UzlabojumsImproved OCPP meter values
- UzlabojumsImproved discovering devices when dynamic control is active
- UzlabojumsImproved user interface when updates are in progress
- UzlabojumsLocal load balancing is now implemented as dynamic control based specific conditions
- UzlabojumsImproved Bluetooth connection
- UzlabojumsImproved 4g connections robustness
- UzlabojumsImproved STM32 lock timings
- UzlabojumsImproved OCPP now allows external intensity limits
- UzlabojumsImproved data consumption
- LabojumsWhen locking a connector while charging, it now sends end charge telemetry correctly
- LabojumsFixed dynamic control issues
- LabojumsFixed Carlo Gavazzi power meter
- LabojumsFixed OCPP LMS, diagnostics, and charging profile clearing
-
- JaunumsAdded shared library
- JaunumsTimezone can be set manually
- JaunumsTime is now synced with Central System if OCPP is active
- UzlabojumsImproved version/update manager
- UzlabojumsImproved megabyte conversion of Network Monitor
- UzlabojumsObtaining timezone now doesn't need to have correct time by using only http urls
- UzlabojumsMobile usb device name is now obtained dynamically since more usb ports might be used due to TPV
- LabojumsFixed power control issues
- LabojumsFixed that when locking connector during a charge it now ends correctly
- LabojumsRecalculate reboot time when changing time with ble
- LabojumsWe now show on screen when non registered RFID is passed while OCPP is active
- LabojumsFixed OCPP freemode rfid issues
- LabojumsDuplicate StatusNotifications are removed from offline queue
- LabojumsFixed "infinite" OCPP offline queue issue
-
- JaunumsAPN can now be set manually
- UzlabojumsWe now show on screen different wifi images depending on how strong signal is to let know the user how good the connection is
- UzlabojumsGeneral OCPP improvements: we check connection to CS instead of internet for local functioning, we notify a real value now when there's a stop transaction due to power loss, fixed edge cases where connectivity is lost, new ocpp key MaxEVCurrentOffered implemented which limits charge with key instead of smart charging handler, safety mechanisms for ocpp to be more robust
- UzlabojumsIn 4g, increased rssi range for "excellent" so that it indicates correctly when the reception is good
- UzlabojumsImproved data consumption
- UzlabojumsImproved robustness of update
- AtjauninātsAccess point time increased to 15 minutes
- LabojumsHandled issues when SSID has whitespace
-
- LabojumsAccess point improvements.
- LabojumsFixed QA issues.
-
- JaunumsNew direct method to obtain additional information for Smart Charging.
- JaunumsFixed random reboot time.
- UzlabojumsFixed unset RFID.
- UzlabojumsFixed Unknown measurer and made distinction between Unknown measurer and wrongly configured measurer.
- UzlabojumsOCPP Free mode can be toggled through OCPP keys.
- AtjauninātsFixed BLE connection with iphone and fixed bluetooth communication error that appeared on app.
- AtjauninātsNetwork improvements. No interface resets performed at boot which improves bootup time. Network changes now don't require reboot. When changing WIFI settings or ip ethernet settings, it connects after setting it instead of rebooting.
- LabojumsFixed issue where things on screen were missing in one connector chargers.
- LabojumsFixed time/timezone issue caused when the date is off by a few days.
- LabojumsNew property added to toggle if vehicle should be able to charge even though measurers aren't working ( Only works when OCPP, payments or dynamic control isn't enabled ).
-
- JaunumsReflect on screen when charge is paused.
- JaunumsMade reboot time random.
- LabojumsIncreased SAS token time to live of azure.
-
- JaunumsChanges made to reduce network usage that can be toggled on or off.
- JaunumsFixed case where config is corrupted or missing and would give trouble at startup.
- JaunumsWe now send dead letter if cpu gets too hot and cpu temperature is now logged.
- UzlabojumsFixed OCPP inverted measurer error.
- UzlabojumsAdded mechanism to disable or enable Wifi and bluetooth.
- UzlabojumsWe now report information regarding which type of connection to the internet the e-charger has.
- AtjauninātsChanged led colors. Switched State A (now white) and State B (now green) colors.
- LabojumsFixed set threshold values and neopixel leds of Stm32. We can now also obtain control pilot value from Stm32.
- LabojumsOCPP ConnectionTimeOut value can now be changed on the fly.
- LabojumsWe now report iccid of sim card is connected. If sim is connected but we can't obtain iccid, we send dead letter.
- LabojumsFixed log download of http interface.
-
- JaunumsLTE signal is now reflected correctly instead of always showing great signal.
- UzlabojumsFixed wathdog reboot after doing hard reset.
-
- JaunumsAdded dynamic photovoltaic.
- JaunumsAdded dead letters: measurer fails and kernel error.
- JaunumsProperty "wifi_info" is now reported.
- JaunumsProperty "wifi_static" can be set through ble.
- JaunumsWe can now obtain statistics through direct method.
- JaunumsAdded individual log level for each type of logger.
- JaunumsAdded neopixel led type for stm32.
- JaunumsWe can now set threshold values with stm32 and get control pilot value if debug log of "Stm32" is activated.
- UzlabojumsImprovements in dynamic control, fabrication, QA, Azure, OCPP, config handling, 4g, access point and stm32.
- UzlabojumsWe now obtain timezone through url.
- UzlabojumsRemoved raspbian logo and desktop during boot and added V2C logo.
- UzlabojumsChanged default language after fabrication from english to spanish.
- AtjauninātsGeneral bug fixes.
- LabojumsWhen downgrading we ensure that version we downgrade to is compatible.
-
- JaunumsFixed property "ocpp" change bug.
- UzlabojumsProperties "powerweekday", "powerweekend" and "phase_map" can be changed through bluetooth.
- UzlabojumsChanged configuration handling to differentiate internally and externally set variables so that externally set or obtained variables are handled accordingly following the property schemas.
- LabojumsWe now report wifi_static with static ip configuration.
- LabojumsStatistics are now saved locally.
-
- UzlabojumsMeasurer fails are now registered with modbusrtumeasurer.
- UzlabojumsScreen font bigger for small title.
- LabojumsValidate configuration with schemas during loading.
-
- JaunumsOCPP authorize can now function by connector.
- JaunumsOCPP WSS connection.
- JaunumsFixed OCPP parent id tag bug.
- JaunumsOCPP meter values now work for 3 phases.
- UzlabojumsFixed error 3 not appearing on screen.
- UzlabojumsFixed energy by hour bug.
- UzlabojumsChanged measurer reading approach for faster reads.
- UzlabojumsWith dynamic balancing we now show used and available power in frontend.
-
- UzlabojumsWe show dynamic balancing information on screen.
- UzlabojumsSimplified handling of configuration.
- UzlabojumsImproved dynamic balancing.
-
- UzlabojumsCharger won't reboot if car is in state B and OCPP or Payments is active.
- UzlabojumsWhen car changes from state C to B, charge information will persist on screen.
- UzlabojumsCurrent state charge now reports errors.
- UzlabojumsAdded configuration property validation.
- LabojumsDirect method to obtain dynamic balancing information.
- LabojumsGeneral dynamic balancing improvements.
- LabojumsOCPP improvements.
-
- LabojumsChanged remaining set_basic_unreported_config to set_basic_config.
-
- JaunumsFix dynamic control bug, powerbytram is not being updated.
- JaunumsFixed bug where whitelist of reported items wasn't being applied and properties weren't being stored in database.
- UzlabojumsRemoved non-repetitive logger.
- UzlabojumsChanged access point interface to change apn, with manual mode or mobile operator mode.
- AtjauninātsRefactored config charge box. Removed BASIC_UNREPORTED and created whitelist of properties to report.
- AtjauninātsPhase map is now not applied to installation meters.
- LabojumsFixed payment bug where a charge couldn't be started properly if charge was started with the hose unlocked.
- LabojumsFix bug with power being zero, dynamic control failing when there are no connectors.
- 3.1.8AtjauninātsForce WIFI and bluetooth GPIO pins for compute module 4 to work.
- 3.1.7AtjauninātsForce 4g GPIO pins for compute module 4 to work.
-
- UzlabojumsWhen we detect that measurers aren't working, we send an unblock command in case there's a charge and the charger has lost power.
- UzlabojumsCreate section BASIC_UNREPORTED for properties that are used but we don't want to report.
- UzlabojumsLocked value has persistance when measurers fail.
- LabojumsWhen we don't receive petitions from chromium we now press enter and Ctrl+F5 if there's anything we need to accept.
-
- LabojumsChanging WIFI configuration with bluetooth now reboots the charge point.
-
- UzlabojumsFixed configuration file so that software works with compute module 3 and 4.
- UzlabojumsChanged reboot logic. It will now reboot if there's a car connected but charge is not allowed.
- LabojumsChanged payments qr code.
- LabojumsWe can change log level with property.
-
- LabojumsMeter values fixed. We now send wh instead of kwh.
-
- JaunumsPause is now reset when it goes back to state A.
- JaunumsShow measurer error as "Error 3" on connector. Behaviour is that connector is locked until it's fixed.
- JaunumsSet wire connected again.
- UzlabojumsFixed general network errors. Improved access point and wifi connectivity.
- LabojumsFixed error where timezone wasn't set correctly so time appeared incorrectly.
- LabojumsFixed payment_max_mode timeout bug.
-
- JaunumsFixed power, it was shown in W and is now in Kw.
- UzlabojumsChange timezone automatically.
- LabojumsAdded triphasic phoenix contact measurer.
- NoņemtsFixed removal of grey notification update.
-
- JaunumsWhenever there's an action that provokes rebooting, it will show on screen that it's going to reboot and the cause.
- JaunumsScreen orientation can now be set and depending on parameter.
- JaunumsAdded error message 1 and 2.
- JaunumsBluetooth patch so that bluetooth initialization takes less time.
- JaunumsCreated patch system. System level changes will be applied with this system.
- UzlabojumsMeasurer refactoring.
- UzlabojumsImei obtention improved.
- UzlabojumsInitial version of bluetooth finished: Obtain properties change basic properties, program charge, reboot, add rfid and change wifi.
- UzlabojumsBoot improvements. "Page not found" isn't shown anymore. Boot is faster. There's a gif indicating that system is starting.
- UzlabojumsObsolete properties are now deleted automatically so that they aren't reported.
- AtjauninātsRFID can now function with payments. If RFID is enabled with payments, registered cards will be able to start charges. If RFID is disabled with payments, no card will be able to start a charge.
- LabojumsLimited number of messages we can send to iothub.
- LabojumsIn OCPP, fixed sending of meter values. Now sending in wh and not in kwh.
- LabojumsBoot patch so that GPIO pin initialization takes less time.
- LabojumsMonophasic measurer Eastron SDM220 implemented.
- LabojumsImproved robustness on all direct methods.
- LabojumsFixed bug where it didn't reconnect properly to iothub when it disconnected.
- LabojumsCreated direct method to put a QR code on the OCPP screen.
- NoņemtsRemoved wire_connected event telemetry.
- 3.0.9LabojumsFixed ocpp meter value Energy.Active.Import, when measurer is flipped.
-
- AtjauninātsFixed error where e-Charger couldn't obtain dns when connected with WIFI.
- LabojumsFixed local load balancing when one connector was charging. Now when one connector is charging, it will charge at the set intensity.
- 3.0.7LabojumsFixed ocpp Remote Start Transaction and Remote Stop Transaction.
- 3.0.6LabojumsFixed error that ocurred in ocpp where it didn't clear properly the idtag when finishing a transaction.
-
- AtjauninātsChanged access point ip from 192.168.44.1 to 192.168.4.1
- AtjauninātsWe now report the charger's state instead of the requested vehicle state.
- AtjauninātsChanged access point master password.
- LabojumsFixed websocket connection issue with nuitka compilation.
-
- UzlabojumsImproved update logs.
- 3.0.3JaunumsMoved Version from center to right side and added V. before the version number.
- 3.0.2UzlabojumsSTM will now detect SPI bus communication errors and will automatically reset.
-
- JaunumsScreen now shows when RFID card is registered.
- JaunumsTop bar now shows version and if access point is accessible.
- JaunumsAccess point interface now has, local load balancing, rfid card registering and log download.
- JaunumsCheck that compute module and board have been created properly.
- UzlabojumsScreen is now monitored so that it refreshes in the case that no requests have been made after 15 seconds.
- UzlabojumsQA diagnostic is obtained through access point.
- UzlabojumsReduced access point available time to 10 minutes.
- LabojumsFixed bug where connector stopped working properly when sending intensity 0.
-
- JaunumsInitial Version
6 no 46