Trydan and Trydan Pro updates
We are continuously working to improve the features of Trydan and Trydan Pro. Here you will find the latest version of our e-Charger and the most recent updates we have made.
Latest version
2.5.2
Trydan and Trydan Pro
2.5.2Latest version
New inverters (Solplanet/AISWEI, Hoymiles, Huawei without dongle), battery discharge control, unified statistics in mixed three-phase, and cybersecurity improvements in Bluetooth.
- NewDirect query of OCPP status
- NewNew Solplanet/AISWEI Inverter
- NewNew Hoymiles Inverter
- NewBattery discharge control: GoodWe, SolarEdge
- NewHuawei inverters direct connection without Dongle
- NewUnified statistics in mixed three-phase charging (the session is not divided when switching between three-phase and single-phase)
- NewNew "Unlimited" Wake-up 5 mode available from the LCD
- NewImprovements in Bluetooth cybersecurity
- ImprovedFixes in FV mode + Minimum power
- ImprovedOCPP: duplicate BootNotifications are avoided
- ImprovedSecurity menu lock during vehicle charging
- ImprovedImprovements for Linky-LORA
Earlier versions 46
-
- NewCompatibility with SigEnergy inverters
- NewNew model of Ingeteam three-phase inverter (ISS 3PLAY)
- NewWiFi connection for Deye inverters via Elfin
- NewExpansion to 105 RFID cards
- NewPAP/CHAP authentication for 4G connection
- NewMore stable OCPP connections
- ImprovedReading the P1 and Victron meters is more reliable in the event of communication failures.
- ImprovedStability of mixed three-phase charging
- ImprovedError reporting and diagnostic system
- ImprovedImprovement of home battery charging priority in PV charging modes
-
- NewManagement of home battery discharge in charging profiles
- NewUnlocking the Trydan by smartphone proximity
- NewNew models of SofarSolar and Azzurro inverters
- NewAdded current and voltage per phase in Home Assistant and Modbus API.
- NewWiFi connection in Deye inverters
- NewIncrease of up to 80 RFID cards
- NewBattery compatibility in SolarEdge inverters
- NewScroll text for long texts
- ImprovedOptimization of Ethernet network interface
- ImprovedImprovements in the Modbus TCP client
- ImprovedImprovements in mixed three-phase charging
- ImprovedImprovement of texts in German
- ImprovedIncrease the voltage range of the installation from the control panel.
-
- FixedOCPP password bug
- FixedProblems connecting to CSMS after restarts
-
- NewTarget charge kWh
- NewNew SMA Sunny Boy model
- NewNew Fronius model with battery
- NewSelect Modbus API address ID
- NewNew Deye models
- NewSofar Solar inverters
- NewAzzurro inverters
- NewSelect MID address
- NewEMMA Huawei
- NewSecurity Profile 2 OCPP (wss + auth + CA cert)
- NewPrivate 4G SIMs in OCPP
- NewOcppFreeMode
- NewOCPP internal queue messages
- ImprovedTime synchronization
- ImprovedPower plate measurements 1.0
- ImprovedWiFi improvements
- FixedExclusive mode bug with batteries
- FixedCoordinate "ContractedPower" and load profiles with HTTP API.
- FixedImprove RFID errors
- FixedMixed load bug
- FixedBug photovoltaic mode + minimum
- FixedBug statistics without FV via BLE
-
- NewMIFARE Ultralight RFID cards
- ImprovedMore robust OTA update
- FixedBug management autolock with payments mode
- FixedBug in payments mode with RFID
-
- ImprovedInstallation problem readings
- ImprovedImprovement in BYD mode
- FixedBug with Wibeee inverter
-
- NewObtain firmware version via Modbus
- NewGoodWe via Modbus TCP
- NewOCPP: FirmwareManagement
- NewAutolock
- NewNew MID models
- NewNew wake-up modes
- NewAllow changing the charging type in HA (single-phase, three-phase, or mixed)
- NewLinky meter for French meters
- NewModbus termination resistance
- NewReading individual properties HTTP API
- NewTurn off/Turn on logo and LCD from HTTP API
- UpdatedImprovements in dynamic control
- UpdatedImprovement in Sungrow inverter measurements
- UpdatedImprovements in the OTA update
- UpdatedImprovements in the button panel menu
- UpdatedNew Deye models
- UpdatedOCPP: improvement in MeterValues
- UpdatedOCPP: send StatusNotification "Faulted" with errors and warnings
- UpdatedOCPP: publish current version
- UpdatedOCPP: BootNotification timeout
- UpdatedNew NTP servers
- UpdatedImproved WI-FI scanning
- UpdatedImprovement in P1 meter
- UpdatedImprovement in remote logs
- UpdatedIoT call limitation per charger
- UpdatedImprove RAM memory
- UpdatedStability via Ethernet
- UpdatedCorrected translations
- FixedError "Waiting for Power"
- FixedBug with RFID cards with long names
- FixedBug when requesting the list of Wi-Fi SSIDs via Bluetooth.
- FixedImprove statistics via Bluetooth
- FixedLocal balancing improvements for up to 10 devices
- FixedBug when sending RFID code in the statistics
- FixedBug with Exclusive PV mode and batteries
-
- NewStatic power control is added (only with Trydan consumption).
- NewMixed charging adapts to European rates.
- NewPower control programming with phase limits is allowed.
- NewThe power control adapts to European countries with phase current limits.
- UpdatedThe power control algorithm has been modified step by step to apply PID modulation.
- UpdatedThe static power control between sockets or between e-Chargers is improved.
- FixedThe failure of remote records is avoided when a disconnection occurs.
-
- FixedBug DTSU666-G meters
-
- ImprovedImprovement in Wake Mode
- FixedFixed bug when changing the port in MQTT.
-
- NewEcoCharging to schedule charging automatically during the cheapest daylight hours.
- NewTurning on and off LEDs via Modbus TCP/RTU. Option to adjust and query the intensity of the LEDs and the LCD screen.
- NewCompatibility with the new Chint DTSU666-G meter model, allowing for broader integration in various installations.
- NewFirmware update of the V2C ControlBox meter (2.0) via the access point (AP) and the mobile app.
- NewImprovement in the reading of electrical signals: State F detection implemented, enhancing the system's ability to recognize and respond to different operating conditions.
- NewImprovement in the reading of electrical signals: The reading of the input PWM signal has been implemented using DMA (Direct Memory Access), enhancing efficiency and reducing processing load.
- NewOCPP: Detailed reasons for OCPP functions, providing more comprehensive information about the actions taken and facilitating the diagnosis and analysis of events.
- NewOCPP: The ability to operate in offline modes, allowing the charger to function correctly even without a connection to the server. Pending messages are stored and sent once the connection is restored, ensuring reliable and consistent communication.
- NewOCPP: New OCPP state machine. Now, the system connects to the OCPP Central Server (CS) and receives most commands, improving interoperability and remote control.
- ImprovedReading the power value of the batteries in Goodwe EH and ET inverters.
- ImprovedSystem optimization: reduction of RAM usage, improving overall system stability and performance.
- ImprovedImprovement in the reading of electrical signals: Enhanced verification for state E, in addition to omitting zero values from the DMA to avoid incorrect readings.
- ImprovedImprovement in reading electrical signals: Now the CP (Control Pilot) signal is read using a parallel task, which enhances the accuracy and response of the system when interacting with the electric vehicle.
- ImprovedImprovement in the reading of electrical signals: Enhanced stability during this calibration process through the app.
- ImprovedOCPP: Host name resolution. Optimization of libraries to improve DNS resolution and the reliability of secure connections via Secure WebSocket (WSS), increasing stability in communication with remote servers.
- ImprovedOCPP: Ensuring that all important information reaches the server once the connection is restored through a persistent message queue.
- ImprovedOCPP: Status notifications. Improving communication with the central server for sending status notifications.
- FixedOCPP: Fixed a false card detection alert that appeared when starting the system, avoiding confusion and improving the user experience.
-
- NewVoltage reading and writing manual for installation for Modbus TCP and HTTP integrations.
- NewSAJ hybrid inverters
- NewShelly Pro meters
- NewInformation on the response /RealtimeData from http at the request of the developer of the official HA integration.
- NewDirect methods to activate the access point (WiFi AP) and ping a specific IP.
- NewTopic trydan_v2c_voltage to write the installation voltage via MQTT.
- ImprovedLeak detection
- ImprovedMemory management to avoid unexpected restarts with OCPP and the deletion of scheduled power profiles.
- ImprovedModbus TCP connections of Trydan and Trydan Pro with Huawei, Fronius, Victron, Ingeteam, SolarEdge, Kostal Plenticore, SMA, and SAJ Hybrid in error 252.
- ImprovedVisualization of the RFID card authentication process in OCPP
- ImprovedThe memory used in JSON and OCPP goes to the SPI RAM.
- FixedInformation about RFID cards to the OCPP platform standard for compatibility with platforms like E-flux, Monta…
- FixedCollision between the SPI elements (RFID, Ethernet, and GPIO extender) of Trydan Pro
-
- NewAdaptation of OCPP to new central systems
- NewNew Deye models
- ImprovedImprovements in the direction detection of the V2C 2.0 control box
- FixedLEDs blink when there is no connection.
- FixedBug in Greenheiss hybrid
-
- NewDeye / Turbo Energy three-phase
- NewShelly Pro EM and Shelly Pro 3EM (Beta)
- ImprovedShow text on bidirectional meters
- ImprovedReadings with Fronius and DTSU666
- ImprovedReaction times in the leak detector
- ImprovedShow Waiting for Charge in Stop mode
- FixedBug with French language
- FixedRaise the HTTP server via Ethernet
- FixedBug in payments
- FixedRead-only in the OCPP properties
- FixedSave power segments via Bluetooth on some devices.
- FixedShelly Portugal measurements
-
- NewLive Remote Logs
- ImprovedShow stop due to dynamic control
- ImprovedRestarts due to reconnection attempts
- ImprovedQA Protocol
- ImprovedVoltage and Temperature Reading Power PCB
- FixedNaN measurement on some meters
- FixedError in Home Wizard readings
-
- ImprovedPerformance improvement and future compatibility between Trydan and Trydan Pro.
- ImprovedImprovements in OCPP protocol
- ImprovedImprovements in the QA process
- ImprovedImprovement in memory usage
- ImprovedMore robust statistics
-
- NewNetworks with WPA3 security
- NewNew BLE (NimBLE)
- Newe-keys via BLE connection
- NewNew language: Romanian
- NewEnphase version 7.x.x, Solis with batteries
- NewAdaptation of the i2c power board
- ImprovedAzure library update
- ImprovedUpdate of ESP-IDF and Arduino-ESP32 libraries
- ImprovedInvestor communication via WiFi connection without Internet
- ImprovedImprovement in V2C 2.0 meter refresh rate
- ImprovedImprovement in OCPP, adaptation to support disconnections
- ImprovedImprovement in key fob detection
- ImprovedImproved refresh rate
- ImprovedImprovement of values in Huawei, improvement of Chint in Huawei, and end of charge review.
- FixedModification of Deye/Turbo Energy batteries
- FixedCustomizable MQTT topics and username/password
- FixedDisconnection statistics report
- FixedBLE compatibility of iPhone
- FixedOperation of V2C 2.0 meter at night
- FixedAutomatic date and time
- FixedInteraction with Megane
-
- NewBug in photovoltaic three-phase mode
- ImprovedWiFi recovery routine
-
- NewMixed three-phase charging available through the physical menu.
- NewAdded three-phase MID Meter
- NewInclusion of server ID 2 in SolarEdge inverters
- NewAdded Modbus registers with the meter measurement.
- NewHTTP commands added for integration with HA.
- NewEnphase Envoy Inverter (beta) (versions 5.x.x)
- NewV2C 2.0 error detection of clamp not connected
- NewMQTT Slave with user/password authentication and customizable topics (beta)
- ImprovedImprovement of the WatchDog to prevent system freezing
- ImprovedImprovement of nearby WiFi scanning
- ImprovedBluetoothLE service reconnection protocol
- ImprovedWiFi optimization IRAM and affinity with the Azure task
- ImprovedReconnection protocol in the absence of WiFi
- ImprovedFactory reset
- ImprovedThe error code and LED interface
- ImprovedImproved the Isolated Installation mode and zero feed-in.
- ImprovedReduction in cut-off time through dynamic control to 1 min
- ImprovedAutomatic detection of time and time zone
- ImprovedThe optimization and refactoring of the measurement slaves
- ImprovedUnlocking with BLE Tag
- FixedOccasional LCD freezes
- FixedFalse positives from the leak detector
- FixedProblems with the MID Meter
- FixedLED error during update
- FixedDefault value for JSON type variables
- FixedMeasurement at 0 in Deye/TurboEnergy Inverter
- FixedVisual errors and local balancing address assignment
-
- NewSolar Discount on Shortcuts
- NewDeye/TurboEnergy Inverter Beta
- NewPhoenix Contact meter
- NewCarlo Gavazzi meter
- ImprovedOCPP improvements and tested in MONTA
- ImprovedProblems in dynamic control
- ImprovedReconnections and WiFi Stability
- FixedFrozen LCD
-
- NewIsolated Mode in Photovoltaic Modes
- NewDutch, Danish, and Valencian
- NewLeak sensor modes (installer menu)
- NewMID meter (installer menu)
- NewNew Ingeteam protocol (Battery Management)
- NewThree-phase meters DTSU666
- NewSDM three-phase meters
- ImprovedLocal Balancing Protocol and priorities
- ImprovedDetection of ports and hosts in OCPP
- ImprovedStable version of SMA Sunny Boy
- ImprovedPortuguese version of Wibeee
- ImprovedFronius measuring home consumption
- FixedUnexpected locks and unlocks
- FixedWhite blinking in locked mode removed
- FixedError selecting the slaves in beta
- FixedError of SolarEdge three-phase inverters
-
- NewChanges and improvements in calibration
-
- ImprovedCalibration adapted to the new hardware
- FixedData analysis in Kostal Piko fixed
-
- NewLocal balancing between Trydans available via WiFi or wired connection.
- NewSDM-220/320/120 (Tested with the Eastron brand)
- NewDDSU-666 Meter (Common in Huawei installations)
- NewSelf-calibrating without the need for a car
- NewManual hour available
- NewHTTP requests to manage the logs
- NewNew Modbus Registers
- NewGreenheiss inverters
- NewSAJ inverters
- NewWired Solis inverters
- NewResponse time in configurable dynamic control
- ImprovedConfigurable installation voltage
- ImprovedNew manufacturing process
- ImprovedIncluded Shelly three-phase but without FV measurement.
- ImprovedCar consumption via MQTT fixed
- ImprovedImproved and more intuitive physical menu
- CompatibilityBeta models of Goodwe: the battery measurement is canceled.
- FixedBug in Max and Min Intensity via Modbus fixed.
- FixedFalse positives in the leak detector fixed
-
- NewPrevention of conflicts between slaves and the cloud
- FixedGoodWe conflicts and Azure initialization
- FixedFix in Shelly with only three-phase.
-
- ImprovedPending statistics will be sent only once.
- ImprovedShelly 3EM three-phase and modification for Portugal
- FixedModbus Multiple Readings Hotfix
-
- NewNew Modbus registers
- NewRFID reader in alpha version
- NewSolaX X3 híbrido compatible
- NewAvailable calibration and shortcuts via WiFi
- ImprovedOCPP Improvements
- ImprovedImprovement in WiFi scanning
- ImprovedImprovement in reconnection routines
- FixedBluetooth timezone failure
- FixedError in Trydan synchronization - APP
- FixedStatic IP configuration in Trydan via WiFi
- FixedError saving Modbus parameters
-
- NewNew method for calibrating communication with the car
- NewBeta version of the GoodWe ET/EH/BT/BH
- ImprovedImprovement in the communication analysis with the car
-
- NewAuto lock after 60 seconds without a car (shortcut)
- NewModification for Three-Phase Installations in Portugal for V2C 2.0
- NewKostal Piko is added.
- ImprovedReformulation of the Dynamic Control Algorithm
- ImprovedImprovement in the refresh rate of Huawei inverters
- ImprovedSolarEdge stable (Meter measuring export)
- ImprovedStable version of GoodWe
- ImprovedDetection of state D and E according to protocol
- ImprovedImproved QA process
- FixedStored in memory after writings via Modbus TCP and RTU
- FixedBug in the FV measurements and peaks resolved for V2C 2.0
-
- NewGoodWe in beta version
- NewCheck the charging status to avoid short charges (Car at 100% or on scheduled charging)
- ImprovedMQTT in stable version
- ImprovedVictron in stable version
- ImprovedImproved connection with Azure
-
- NewMQTT slave beta version
- ImprovedDetection of power direction in Wibeee
- FixedThe Victron and SolarEdge inverters were bringing down the system.
-
- NewSolarEdge inverter added (Beta)
- NewVictron inverter added (Beta)
- NewAutolock enabled in shortcut (60 s)
- NewAutomatic time zone detection
- NewAlternative meter for car consumption (RS485)
- NewFV Exclusive with configurable variation
- NewNew Languages (French, Italian, and German)
- FixedFixed error in minimum power mode.
-
- ImprovedImprovements in Dynamic Control with batteries
- ImprovedImprovements in Dynamic Control in Three-Phase Installations (Exclusive Mode and Minimum Power)
- FixedResolved the IP configuration issues for Trydan with WiFi and BLE.
- FixedResolved the issues with the IP configuration of Shelly BLE.
-
- NewInclusion of the Wibeee meter
- NewSlave 2.0 compatible with Type 1 and Type 2 installation
- NewChange in the established connection blinking
- NewDetection and measurement of bifacial load
- NewImprovement in the collection and transmission of charging data
- NewAlternative Meter Phoenix Contact (ModbusRTU)
- NewModbusRTU in Trydan (simultaneous slave and master)
- NewStatic IP configuration in Trydan
- NewPossibility to select the IP in Shelly
- ImprovedInclusion of maximum intensity in OCPP (as a property)
- ImprovedImprovement in the reading of Solax inverters
- ImprovedInclusion of batteries in Huawei, Ingeteam, and Fronius inverters.
- ImprovedModbusRTU and Modbus TCP server in Trydan
- UpdatedFirst stable version of Ingeteam
- UpdatedImprovement in the speed of the leak detector
-
- FixedError solution in manufacturing when saving WiFi
-
- NewEliminate false communication errors from the slaves.
- NewSave the first Shelly that Trydan connects to.
- UpdatedWith dynamic control disabled, maintain intensity after finishProgramedSaveMode.
-
- ImprovedImprovement in telemetry recovery in OCPP
- ImprovedImprovement in scanning nearby WiFi networks
-
- NewInternal Azure ping every 15 seconds to detect disconnections.
- NewSeparate reconnections to avoid crashing the server.
- NewOCPP adaptation to work with Home Assistant
- ImprovedMigration of the I2C for the clock and LCD to native idf
-
- ImprovedIncrease maximum binary size in local webServer
- FixedRecovery of OCPP transactions to prevent telemetry failures
-
- NewThe configuration of different IDs for Huawei inverters is added.
- ImprovedCorrection of the power reading of the house
- FixedCorrection of the lock due to Payment Mode and OCPP after deactivation of these.
-
- NewPayment Method (V2C Payments)
- NewOCPP Protocol
- ImprovedImprovement of WiFi and Bluetooth stability and reconnection
- FixedReconnection improvement in the inverters and fix after the update of the Huawei SUN2000.
-
- FixedCorrection of the maximum file size for updates on Local Server
-
- NewList of available WiFi networks from Trydan (for viewing from iPhone and Android)
- ImprovedReconnection with V2C Cloud after communication loss
- FixedCorrected Shelly and Solax routines
-
- NewShortcuts on the buttons: Lock and Charging Schedule
- NewLocal Web page for configuring the Trydan accessible via AP or STA WiFi
- NewAP mode when the configured WiFi is not available
- ImprovedImprovement in LED error codes
- ImprovedAdaptation for compatibility with Huawei inverters
-
- NewWe added connectivity with Fronius inverters.
- ImprovedImprovements in screen writing and removal of strange characters
- ImprovedImprovement in the transmission of statistics via both WiFi and BLE.
-
- NewError correction x and y
6 of 46